Search NASA⌕ Search

SEARCH · Search NASA

Results for “BEAM FOCUSING MAGNETS”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 55 records · Page 3

Electron dynamics and energy conversion in O-type linear-beam devices.

A general nonlinear interaction theory is used to investigate the effects of transverse fields (i.e., radial circuit fields and radial space-charge fields) in traveling-wave amplifiers for a variety of beam-focusing conditions. Magnetic focusing fields which are periodic or tapered (increased) with distance along the device are considered in addition to uniform magnetic fields. Results are presented for Brillouin flow and near-Brillouin flow, and the minimum magnetic field strength required to effectively constrain the electron beam is determined as a function of the operating parameters for the various focusing systems. Confined flow is also examined for the uniform-field case in order to have a basis of comparison from which the effects of radial motion of the beam electrons can be determined. The results indicate the importance of transverse effects and further yield information on the stability of strongly modulated cylindrical electron beams.-

Detweiler, H. K.↗

LANSCE CCL Performance Limits

This report summarizes the performance limits of the LANSCE Coupled-Cavity Linac (CCL). These results are captured or summarized directly from the references cited. This report was written in support of the LANSCE Modernization Project (LAMP). Many factors contribute to the performance limits of the CCL accelerator system. One performance limit is set by the CCL mechanical structure and available cooling. Heating of the structure is ultimately linked to the operating RF duty factor of the CCL. Another performance limit is set by the maximum RF and beam duty factors that can be supported by the 805-MHz klystrons and associated HVDC power supplies. The RF and HVDC systems also set limits for the maximum peak beam current that can be accelerated in the CCL. And finally, a maximum beam current limit is set by the beam dynamics determined by the details of the CCL physics design (number of cells per CCL tank, accelerating gradients, magnetic focusing lattice, beam losses, etc.). This limit can be informed by both simulation results and beam measurement data, if available. A detailed explanation of each performance limit is given in the sections below. The results are summarized in the table below. In all cases, it is assumed that the CCL and the RF system are operating in their nominal beam production configuration – nominal magnet set points and nominal cavity fields, unless otherwise specified.

43 PARTICLE ACCELERATORS↗

Three-Dimensional Electron Optics Model Developed for Traveling-Wave Tubes

A three-dimensional traveling-wave tube (TWT) electron beam optics model including periodic permanent magnet (PPM) focusing has been developed at the NASA Glenn Research Center at Lewis Field. This accurate model allows a TWT designer to develop a focusing structure while reducing the expensive and time-consuming task of building the TWT and hot-testing it (with the electron beam). In addition, the model allows, for the first time, an investigation of the effect on TWT operation of the important azimuthally asymmetric features of the focusing stack. The TWT is a vacuum device that amplifies signals by transferring energy from an electron beam to a radiofrequency (RF) signal. A critically important component is the focusing structure, which keeps the electron beam from diverging and intercepting the RF slow wave circuit. Such an interception can result in excessive circuit heating and decreased efficiency, whereas excessive growth in the beam diameter can lead to backward wave oscillations and premature saturation, indicating a serious reduction in tube performance. The most commonly used focusing structure is the PPM stack, which consists of a sequence of cylindrical iron pole pieces and opposite-polarity magnets. Typically, two-dimensional electron optics codes are used in the design of magnetic focusing devices. In general, these codes track the beam from the gun downstream by solving equations of motion for the electron beam in static-electric and magnetic fields in an azimuthally symmetric structure. Because these two-dimensional codes cannot adequately simulate a number of important effects, the simulation code MAFIA (solution of Maxwell's equations by the Finite-Integration-Algorithm) was used at Glenn to develop a three-dimensional electron optics model. First, a PPM stack was modeled in three dimensions. Then, the fields obtained using the magnetostatic solver were loaded into a particle-in-cell solver where the fully three-dimensional behavior of the beam was simulated in the magnetic focusing field. For the first time, the effects of azimuthally asymmetric designs and critical azimuthally asymmetric characteristics of the focusing stack (such as shunts, C-magnets, or magnet misalignment) on electron beam behavior have been investigated. A cutaway portion of a simulated electron beam focused by a PPM stack is illustrated.

Kory, Carol L.↗

SU-D-304-02: Magnetically Focused Proton Irradiation of Small Field Targets

Purpose: To investigate the use of magnetic focusing for small field proton irradiations. It is hypothesized that magnetic focusing will provide significant dose distribution benefits over standard collimated beams for fields less than 10 mm diameter. Methods: Magnets consisting of 24 segments of radiation hard samarium-cobalt adhered into hollow cylinders were designed and manufactured. Two focusing magnets were placed on a positioning track on our Gantry 1 treatment table. Proton beams with energies of 127 and 157 MeV, 15 and 30 mm modulation, and 8 mm initial diameters were delivered to a water tank using single-stage scattering. Depth dose distributions were measured using a PTW PR60020 diode detector and transverse profiles were measured with Gafchromic EBT3 film. Monte Carlo simulations were also performed - both for comparison with experimental data and to further explore the potential of magnetic focusing in silica. For example, beam spot areas (based on the 90% dose contour) were matched at Bragg depth between simulated 100 MeV collimated beams and simulated beams focused by two 400 T/m gradient magnets. Results: Preliminary experimental results show 23% higher peak to entrance dose ratios and flatter spread out Bragg peak plateaus for 8 mm focused beams compared with uncollimated beams. Monte Carlo simulations showed 21% larger peak to entrance ratios and a ∼9 fold more efficient dose to target delivery compared to spot-sized matched collimated beams. Our latest results will be presented. Conclusion: Our results suggest that rare earth focusing magnet assemblies could reduce skin dose and beam number while delivering dose to nominally spherical radiosurgery targets over a much shorter time compared to unfocused beams. Immediate clinical applications include those associated with proton radiosurgery and functional radiosurgery of the brain and spine, however expanded treatment sites can be also envisaged.

60 APPLIED LIFE SCIENCES↗

Super-strong magnetic field-dominated ion beam dynamics in focusing plasma devices

High energy density physics is the field of physics dedicated to the study of matter and plasmas in extreme conditions of temperature, densities and pressures. It encompasses multiple disciplines such as material science, planetary science, laboratory and astrophysical plasma science. For the latter, high energy density states can be accompanied by extreme radiation environments and super-strong magnetic fields. The creation of high energy density states in the laboratory consists in concentrating/depositing large amounts of energy in a reduced mass, typically solid material sample or dense plasma, over a time shorter than the typical timescales of heat conduction and hydrodynamic expansion. Laser-generated, high current–density ion beams constitute an important tool for the creation of high energy density states in the laboratory. Focusing plasma devices, such as cone-targets are necessary in order to focus and direct these intense beams towards the heating sample or dense plasma, while protecting the proton generation foil from the harsh environments typical of an integrated high-power laser experiment. A full understanding of the ion beam dynamics in focusing devices is therefore necessary in order to properly design and interpret the numerous experiments in the field. In this work, we report a detailed investigation of large-scale, kilojoule-class laser-generated ion beam dynamics in focusing devices and we demonstrate that high-brilliance ion beams compress magnetic fields to amplitudes exceeding tens of kilo-Tesla, which in turn play a dominant role in the focusing process, resulting either in a worsening or enhancement of focusing capabilities depending on the target geometry.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Study on Conduction Cooling of Superconducting Magnets for the ILC Main Linac

In the main linac of the International Linear Collider (ILC), superconducting magnets for beam focusing and steering will be located periodically in superconducting RF (SRF) cavity string for beam acceleration in common cryomodules. A concept of conduction cooling of the combined-functioned, splittable superconducting magnets has been proposed and investigated to adapt much different features and to meet different requirements for the superconducting magnet and SRF cavity in fabrication, assembly, and operation. It is required to integrate the superconducting magnet after the SRF cavity string assembly which completed under an ultra-clean environment. The magnet must be conductively cooled down through thermal links to a liquid helium supply pipe. According to this concept, a model magnet development was carried out in cooperation with Fermilab and KEK, and has been demonstrated in KEK superconducting RF test facility (STF). In addition, an important issue has been recently identified. High gradient SRF cavities naturally emit field emission electron flux from the inner surface, so-called dark current. It may pass through the subsequent SRF cavity string and penetrate into the superconducting magnets placed downstream. It may heat up the superconducting coils, and may cause a quench. Therefore, further study on reliable conduction cooling and to secure the superconducting magnet operation with a keeping sufficient safety margin is quite essential. In this paper, we report the installation, the improvement achieved in STF, and the R&D progress in the study on the conduction cooling of the superconducting magnet for the ILC main linac.

43 PARTICLE ACCELERATORS↗

A 24 keV liquid-metal-jet x-ray source for biomedical applications

We present a high-brightness 24-keV electron-impact microfocus x-ray source based on continuous operation of a heated liquid-indium/gallium-jet anode. The 30-70 W electron beam is magnetically focused onto the jet, producing a circular 7-13 {mu}m full width half maximum x-ray spot. The measured spectral brightness at the 24.2 keV In K{sub {alpha}} line is 3 x 10{sup 9} photons/(s x mm{sup 2}x mrad{sup 2}x 0.1% BW) at 30 W electron-beam power. The high photon energy compared to existing liquid-metal-jet sources increases the penetration depth and allows imaging of thicker samples. The applicability of the source in the biomedical field is demonstrated by high-resolution imaging of a mammography phantom and a phase-contrast angiography phantom.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Accelerated Electron-Beam Formation with a High Capture Coefficient in a Parallel Coupled Accelerating Structure

An electron beam with a high (close to 100%) coefficient of electron capture into the regime of acceleration has been obtained in a linear electron accelerator based on a parallel coupled slow-wave structure, electron gun with microwave-controlled injection current, and permanent-magnet beam-focusing system. The high capture coefficient was due to the properties of the accelerating structure, beam-focusing system, and electron-injection system. Main characteristics of the proposed systems are presented.

43 PARTICLE ACCELERATORS↗

Intense combined source of neutrons and photons for interrogation based on compact deuteron RF accelerator

Interrogation of special nuclear materials can benefit from mobile sources providing significant fluxes of neutrons (10 8 /s at 2.5 MeV, 10 10 /s at 14.1 MeV) and of photons (>10 12 /s at 1-3 MeV). We propose a source that satisfies these requirements simultaneously plus also provides, via the reaction 11 B(d,n) 12 C(γ 15.1 ), a significant flux of 15-MeV photons, which are highly penetrating and optimal for inducing photo-fission in actinides. The source is based on a compact (< 5 m) deuteron RF accelerator that delivers an average current of a few mA of deuterons at 3-4 MeV to a boron target. The accelerator consists of a short RFQ followed by efficient inter-digital H-mode structures with permanent-magnet-quadrupole beam focusing [Kurennoy et al. (2012)], which suit perfectly for deuteron acceleration at low energies. Our estimates, based on recent measurements, indicate that the required fluxes of both neutrons and photons can be achieved at ~1 mA of 4-MeV deuterons. The goal of the proposed study is to confirm feasibility of the approach and develop requirements for future full system implementation.

43 PARTICLE ACCELERATORS↗

Wakefields of a Beam near a Single Plate in a Flat Dechirper

At linac-based, X-ray free electron lasers (FELs), there is interest in streaking the beam by inducing the transverse wakes in a flat dechirper, by passing the beam near to one of its two jaws. For LCLS-II - as has already been done for LCLS-I - this way of using the dechirper will e.g. facilitate two-color and fresh slice schemes of running the FEL. With the beam a distance from the near wall of say b ~ 0.25 mm and from the far wall by ≳ 5 mm, the second wall will no longer affect the results. The physics will be quite different from the two plate case: with two plates the impedance has a resonance spike whose frequency depends on the plate separation 2a; in the single plate case this parameter no longer exists. Formulas for the longitudinal, dipole, and quadrupole wakes for a beam off-axis between two dechirper plates, valid for the range of bunch lengths of interest in an X-ray FEL, are given in reference 3. By taking the proper limit, we can obtain the corresponding wakes for a beam close to one dechirper plate and far from the other. This is the task we perform in this note.

43 PARTICLE ACCELERATORS↗

Photoinjector Generation of High-Charge Magnetized Beams for Electron-Cooling Applications

The recently announced Electron-Ion Collider (EIC), to be built at Brookhaven National Laboratory, will collide high-energy ion-beams and electron beams to pursue nuclear physics research on quark-gluon plasma's. The facility performances (luminosity) would be improved if the ion-beam emittance degradation is mitigated via a phase-space-cooling technique. One potential cooling method uses a bright electron beam to cool the ion beams. The cooling rate for this electron-cooling method depends on the transverse emittance of the cooling electron beam and could benefit from using a beam with significant canonical angular momentum dubbed as a magnetized beam. This research focuses on simulation and experimental generation and characterization of high charge magnetized electron beams with parameters comparable to those required for electron cooling at an electron-ion collider. The experiment uses the 50-MeV photo-injector available at the Fermilab Accelerator Science and Technology (FAST) Facility. The measurements are benchmarked against simulations.

43 PARTICLE ACCELERATORS↗

Focusing of intense and divergent ion beams in a magnetic mass analyzer

A magnetic mass analyzer is used to determine the beam composition of a vacuum arc ion source. In the analyzer, we used the concentric multi-ring electrodes to focus the intense and divergent ion beams. We describe the principle, design, and the test results of the focusing device. The diameter of the beam profile is less than 20 mm when the accelerating voltage is 30 kV and the focusing voltage is about 2.0 kV. The focusing device has been successfully used in the magnetic mass analyzer to separate Ti{sup +}, Ti{sup 2+}, and Ti{sup 3+}.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Electron-Beam Corkscrew Motion in an Advanced Linear Induction Accelerator

Scorpius is a multipulse linear induction accelerator (LIA) under development for flash radiography. Because it has substantially more cells than present LIAs, higher magnetic focusing fields are needed to suppress beam breakup (BBU). Therefore, it is more susceptible to corkscrew motion of the beam, which also depends on beam energy spread and focusing magnet misalignments. For energy spread and alignment tolerances expected for Scorpius, a magnetic tune designed to suppress BBU is shown to produce corkscrew motion within the range that can be controlled through the use of steering dipoles on existing LIAs. Finally, a gap-voltage modulation scheme is shown to almost completely eliminate chromatic effects such as corkscrew.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Modeling of an Electron-Optical System with Converging Sheet Beam for a Traveling Wave Tube of Terahertz Frequency Range

A converging sheet electron beam with a cross section of 0.05 × 2 mm and current density of 200 A/cm{sup 2}, which is formed by an electron gun, is modeled using the synthesis and analysis methods at the condition of magnetic shielding of the cathode. The deformation in the cross section of the beam in the focusing magnetic field is analyzed based on a computer three-dimensional model of an electron optical system with a sheet electron beam. The current-voltage characteristic of an electron gun is studied experimentally in the pulse mode. A collector current of 200 mA is obtained with the beam thickness being 70 μm.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

WE-D-17A-04: Magnetically Focused Proton Irradiation of Small Volume Targets

Purpose: To explore the advantages of magnetic focusing for small volume proton irradiations and the potential clinical benefits for radiosurgery targets. The primary goal is to create narrow elongated proton beams of elliptical cross section with superior dose delivery characteristics compared to current delivery modalities (eg, collimated beams). In addition, more general beam shapes are also under investigation. Methods: Two prototype magnets consisting of 24 segments of samarium-cobalt (Sm2Co17) permanent magnetic material adhered into hollow cylinders were manufactured for testing. A single focusing magnet was placed on a positioning track on our Gantry 1 treatment table and 15 mm diameter proton beams with energies and modulation relevant to clinical radiosurgery applications (127 to 186 MeV, and 0 to 30 mm modulation) were delivered to a terminal water tank. Beam dose distributions were measured using a PTW diode detector and Gafchromic EBT2 film. Longitudinal and transverse dose profiles were analyzed and compared to data from Monte Carlo simulations analogous to the experimental setup. Results: The narrow elongated focused beam spots showed high elliptical symmetry indicating high magnet quality. In addition, when compared to unfocused beams, peak-to-entrance depth dose ratios were 11 to 14% larger (depending on presence or extent of modulation), and minor axis penumbras were 11 to 20% smaller (again depending on modulation) for focused beams. These results suggest that the use of rare earth magnet assemblies is practical and could improve dose-sparing of normal tissue and organs at risk while delivering enhanced dose to small proton radiosurgery targets. Conclusion: Quadrapole rare earth magnetic assemblies are a promising and inexpensive method to counteract particle out scatter that tends to degrade the peak to entrance performance of small field proton beams. Knowledge gained from current experiments will inform the design of a prototype treatment nozzle that incorporates similar focusing magnets. This project was sponsored in part by funding from the Department of Defense (DOD# W81XWH-BAA-10-1)

60 APPLIED LIFE SCIENCES↗

Influence of the electrode gap separation on the pseudospark-sourced electron beam generation

Pseudospark-sourced electron beam is a self-focused intense electron beam which can propagate without any external focusing magnetic field. This electron beam can drive a beam-wave interaction directly or after being post-accelerated. It is especially suitable for terahertz radiation generation due to the ability of a pseudospark discharge to produce small size in the micron range and very high current density and bright electron beams. In this paper, a single-gap pseudospark discharge chamber has been built and tested with several electrode gap separations to explore the dependence of the pseudospark-sourced electron beam current on the discharge voltage and the electrode gap separation. Experimental results show that the beam pulses have similar pulse width and delay time from the distinct drop of the applied voltage for smaller electrode gap separations but longer delay time for the largest gap separation used in the experiment. It has been found that the electron beam only starts to occur when the charging voltage is above a certain value, which is defined as the starting voltage of the electron beam. The starting voltage is different for different electrode gap separations and decreases with increasing electrode gap separation in our pseudospark discharge configuration. The electron beam current increases with the increasing discharge voltage following two tendencies. Under the same discharge voltage, the configuration with the larger electrode gap separation will generate higher electron beam current. When the discharge voltage is higher than 10 kV, the beam current generated at the electrode gap separation of 17.0 mm, is much higher than that generated at smaller gap separations. The ionization of the neutral gas in the main gap is inferred to contribute more to the current increase with increasing electrode gap separation.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗