Search NASA⌕ Search

SEARCH · Search NASA

Results for “BEAM MONITORING”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 55 records · Page 3

Integration Development and Testing of Rear Transition Monitor for Beam Current Monitoring System

Addressing baseline effects in accelerator environments is crucial for accurate data acquisition and analysis, since baseline effects can obscure signal clarity and impact the reliability of beam current monitoring systems. There are many potential contributors to baseline noise, such as variations in beam dynamics, electromagnetic interference from nearby equipment, or RF interference. Previous applications of noise reduction systems don t sufficiently filter sources of asynchronous noise, so a new algorithm was implemented. A simulation dataset was created to replicate beam conditions and a Red Pitaya FPGA was used to collect data through the streaming application. A Python script was developed to implement noise reduction algorithms and efforts were made to integrate real-time data streaming with the Redis platform and Acnet Front End infrastructure.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

NuMI Beam Monitoring Simulation and Data Analysis †

Following the decommissioning of the Main Injector Neutrino Oscillation Search (MINOS) experiment, muon and hadron monitors have emerged as vital diagnostic tools for the NuMI Off-axis Appearance (NOvA) experiment at Fermilab. These tools are crucial for overseeing the Neutrinos at the Main Injector (NuMI) beam. This study endeavors to ensure the monitor signal quality and to correlate them with the Neutrino beam profile. Leveraging muon monitor simulations, we systematically explore the monitor responses to variations in proton-beam and lattice parameters. Through the amalgamation of individual pixel data from muon monitors, pattern-recognition algorithms, simulations, and measured data, we devise machine-learning-based models to predict muon monitor responses and Neutrino flux.

43 PARTICLE ACCELERATORS↗

Calibration Trigger and Beam Monitoring for the Mu2e Experiment by Means of Decay-in-Orbit $\mu$

Over the last few decades, more evidence has come out to suggest that lepton flavor may not be conserved, making the study of charged lepton flavor violation all the more important. A promising way to observe this phenomenon is through muon conversion to electron (in the case without neutrinos produced) on Al, as will occur in the Mu2e experiment, which will run over the course of three years, beginning in 2023. A major part of the apparatus is the aluminum muon stopping target, which a beam of muons hits before releasing the products of muon interactions into the tracker and calorimeter. A muon stopped in the stopping target can undergo three different processes: nuclear capture, decay in orbit and electron conversion, the last of which makes up the E=105 MeV signal we are aiming to observe. Many muons, however, are scattered into a proton absorber around this target. Muons scattered in this way eventually get stopped in the absorber and then undergo decay-in-orbit , with ele ctron products that peak in their momentum distribution at about 50 MeV/c, giving a reference peak that can be used to calibrate the tracker momentum response. A track trigger was then developed to select events with these tracks. The muon beam used in the Mu2e experiment, however, due to the magnetic field on the beam line, is tilted slightly downward, such that more particles interact with the lower part of the tracker. For calibration purposes it is preferable to have a homogeneous distribution of electrons in the tracker volume, requiring a pre-scale factor that is dependent upon the azimuthal angle of the trajectory of closest approach of the helix to the solenoidal axis (“phi”). The factor in question was then found by running Monte Carlo simulations of the electrons produced in the muon decay in the proton absorber, overlaid with background particles. In addition to being used as means to calibrate momentum distribution, these electron tracks can be used to monitor the muon beam profile for changes over time.Here, these processes are explained in greater detail, and the result of the expected trigger performance is presented.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Picoampere charged particle beam monitor.

Description of a transmission ion chamber for charged particles designed to give continuous indication of beam symmetry and magnitude. The chamber consists of four separate ion chambers. Signals from opposing chambers are compared to determine beam symmetry and summed to obtain a beam intensity signal. The system is simple and offers good linearity at low cost for proton beam currents in the range of 1 to 100 pA.

Smathers, J. B.↗

Diamond Beam Monitor for Medical Dosimetry (Final Report)

In this technical report we will discuss the efforts to develop diamond radiation detectors as dosimeters for therapeutic proton beam diagnostics, measuring the proton fluence as well as the beam profiles in high energy proton beams. The detector performance was recorded as the ion beam induced current (IBIC) from the 800MeV proton beam using different beam conditions. The lifetime of the detectors was also measured by monitoring the real-time detector response changes during the extensive proton irradiation. All irradiated diamond detectors were then characterized using synchrotron X-rays, by measuring the detector performance including I-V curves, response maps, flux scan and timing. The device performance decay was further studied with several simulation packages (SRIM\TRIM and FLUKA), and radiation damage mechanism was investigated by using experimental data and simulation models. Several impact factors (fluence rate, total dose, contact materials and cooling time) were discussed and the radiation effect on carrier transport was studied.

36 MATERIALS SCIENCE↗

PIP-II Beam Current Monitor Fault Case & Beam Position Monitor Linearity Studies in CST Studio

The use of non-invasive sensors & systems to measure particle beam characteristics is a crucial part of modern accelerator control systems. As such, simulations predicting the behavior of these sensors are essential for guiding beamline control system design. This poster details the results returned by two beam sensor models created using CST Studio software: the signal linearity of an elliptical beam position monitor (BPM), and the fault cases of an AC current transformer (ACCT) beam current monitor (BCM).

Rouzky, Adam↗

Pressurized Gas Beam Monitor for Extremely High Intensities

The performance of a gas-filled RF resonator will be numerically simulated to evaluate the sensitivity of permittivity measurements and the effectiveness of calibration strategies. An entire resonator-hodoscope system will be designed and a demonstration test prepared.

43 PARTICLE ACCELERATORS↗

Nondestructive synchronous beam current monitor

A fast current transformer is mounted after the deflectors of the Berkeley 88-Inch Cyclotron. The measured signal is amplified and connected to the input of a lock-in amplifier. The lock-in amplifier performs a synchronous detection of the signal at the cyclotron second harmonic frequency. The magnitude of the signal detected is calibrated against a Faraday cup and corresponds to the beam intensity. It has exceptional resolution, long term stability, and can measure the beam current leaving the cyclotron as low as 1 nA.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗