Search NASA⌕ Search

SEARCH · Search NASA

Results for “BESSY II”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

42 records · Page 3

Autocollimators for Deflectometry: Current Status and Future Progress

The proliferation of autocollimator-based surface profilometers at synchrotron metrology laboratories worldwide necessitates a detailed understanding of the parameters influencing their angular response. A comprehensive overview of the current status of autocollimator characterization and calibration at the Physikalisch-Technische Bundesanstalt (PTB) and its implications for their optimal application are provided, as well as information on future challenges and expected progress. Autocollimator-based deflectometric profilometers are in operation at the PTB, the Advanced Light Source (ALS), Lawrence Berkeley National Laboratory, USA, the BESSY II, Helmholtz-Zentrum Berlin fuer Materialien und Energie GmbH, Germany, and the Diamond Light Source Ltd (DLS), UK. A continuous topic of research at the PTB is to investigate the factors influencing the angular response of autocollimators and to provide the most accurate calibration of the instruments to aid users in their application and manufacturers in their improvements [1-3]. At the PTB, the calibration of autocollimators is realized by a direct comparison of the devices with the primary angle reference standard [1]. With highly stable autocollimators, calibrations with standard measurement uncertainties of u = 0.003 arcsec (15 nrad) have been achieved [2,3]. The influence of a number of parameters on the angle measurement with autocollimators have been investigated in detail, such as the reflectivity of the surface under test (SUT), the diameter and shape of the aperture stop, its position both along the autocollimator's optical axis and perpendicular to it [2], as well as the optical path length of the autocollimator beam [3]. Extensive information on these errors and their minimization will be presented.

47 OTHER INSTRUMENTATION↗

Development of a new generation of optical slope measuring profiler

A collaboration, including all DOE synchrotron labs, industrial vendors of x-ray optics, and with active participation of the HBZ-BESSY-II optics group has been established to work together on a new slope measuring profiler -- the optical slope measuring system (OSMS). The slope measurement accuracy of the instrument is expected to be<50 nrad for the current and future metrology of x-ray optics for the next generation of light sources. The goals were to solidify a design that meets the needs of mirror specifications and also be affordable; and to create a common specification for fabrication of a multi-functional translation/scanning (MFTS) system for the OSMS. This was accomplished by two collaborative meetings at the ALS (March 26, 2010) and at the APS (May 6, 2010).

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Spin Texture Control and Magnetic Gap Engineering in a Ferromagnetic Insulator–Topological Insulator Sandwiched Heterostructure

Quantum materials that combine magnetism with topological order are emerging as key platforms for next-generation spintronics and low-energy electronics. They enable the realization of emergent quantum phenomena, such as the quantum anomalous Hall effect and axion insulator states. The ferromagnetic insulator (FMI)/topological insulator (TI)/FMI sandwich structure of a single-septuple layer (1SL) MnBi 2 Te 4 /four-quintuple layer (4QL) Bi 2 Te 3 /1SL MnBi 2 Te 4 holds great potential to achieve such desirable quantum phenomena at an elevated temperature, owing to its large Dirac point band gap and high Curie temperature. Here, for this work, spin- and angle-resolved photoemission spectroscopy (spin-ARPES) is employed to directly verify that the band gap arises from broken time-reversal symmetry via proximity-driven magnetization. This study demonstrates direct control of the spin state via external magnetic fields and unambiguously confirms the exchange interaction as the gap-opening mechanism. The robust magnetic gap and controllable spin texture make this heterostructure a suitable candidate for spintronic applications and magnetic topological quantum phases.

exchange gap↗

Single-frame far-field diffractive imaging with randomized illumination

Contains two transmission ptychography datasets, one collected from a Siemens star, and the second from an Fe/Gd multilayer. Both samples are under illumination from the same randomized zone plate. Each dataset has a single diffraction pattern removed, and these patterns are reported in a separate cxi file. Either ptychography dataset can be used for calibration of the probe function, and the remaining diffraction patterns can be reconstructed via randomized probe imaging.

BESSY II↗

Sub-microradian Surface Slope Metrology with the ALS Developmental Long Trace Profiler

Development of X-ray optics for 3rd and 4th generation X-ray light sources with a level of surface slope precision of 0.1-0.2 {micro}rad requires the development of adequate fabrication technologies and dedicated metrology instrumentation and methods. Currently, the best performance of surface slope measurement has been achieved with the NOM (Nanometer Optical Component Measuring Machine) slope profiler at BESSY (Germany) [1] and the ESAD (Extended Shear Angle Difference) profiler at the PTB (Germany) [2]. Both instruments are based on electronic autocollimators (AC) precisely calibrated for the specific application [3] with small apertures of 2.5-5 mm in diameter. In the present work, we describe the design, initial alignment and calibration procedures, the instrumental control and data acquisition system, as well as the measurement performance of the Developmental Long Trace Profiler (DLTP) slope measuring instrument recently brought into operation at the Advanced Light Source (ALS) Optical Metrology Laboratory (OML). Similar to the NOM and ESAD, the DLTP is based on a precisely calibrated autocollimator. However, this is a reasonably low budget instrument used at the ALS OML for the development and testing of new measuring techniques and methods. Some of the developed methods have been implemented into the ALS LTP-II (slope measuring long trace profiler [4]) which was recently upgraded and has demonstrated a capability for 0.25 {micro}rad surface metrology [5]. Performance of the DLTP was verified via a number of measurements with high quality reference mirrors. A comparison with the corresponding results obtained with the world's best slope measuring instrument, the BESSY NOM, proves the accuracy of the DLTP measurements on the level of 0.1-0.2 {micro}rad depending on the curvature of a surface under test. The directions of future work to develop a surface slope measuring profiler with nano-radian performance are also discussed.

47 OTHER INSTRUMENTATION↗

NSLS-II Storage Ring Injection Using a Nonlinear Injection Kicker

The NSLS-II has been operating successfully with top off injection since September 2015. Measurements of the stored beam show a transient of 200 μm in the long straight sections during top off injections. This transient is not desirable for some users, particularly those who specialized in imaging or are otherwise sensitive to beam motion. Users are provided with a signal with which they can gate their detectors, but it is desirable to reduce or eliminate this motion all together. Studies have been performed to reduce the transients, and it is clear that the power supplies require more tunability in the pulse shape in order to reduce the transient across the entire bunch train. Other light sources have explored the possibility of using pulsed quadrupoles and sextupoles as the injection magnet. The stored beam receives no kick as the on-axis fields in these magnets is zero, but the injected beam would see a kick as it is off-center. One drawback of the pulsed quadrupole is that the stored beam experiences a size oscillation. Another issue with a nonlinear kicker is the gradient seen by the injected beam. The transport line needs to be tuned for this gradient, and depending on the strength of the nonlinearity, this gradient may change greatly with injected beam position. Therefore, other facilities have explored other magnet configurations that are nonlinear but have a gradient with less positional dependence. The prospect of using a sextupole kicker was investigated during the design phase of the NSLS-II. It was decided that the idea would not be pursued for several reasons. In particular, the design that was studied the most in depth was not compatible with the standard four bump injection design and the tolerances required were deemed too tight at the time. Other ideas were discussed as well and ultimately none were accepted into the design. In this report we discuss the possibility of placing a nonlinear kicker in the first straight section after the injection straight instead of using the injection bumps. The design of the kicker is based on a design that has been used successfully at BESSY and MAX IV. Our conceptual kicker design is compatible with the existing ring optics and power supply requirements. We show that the transport line is capable of being matched to the required optics. The design does not have restrictive tolerances and is a viable option for a facility upgrade.

36 MATERIALS SCIENCE↗