A High-Temperature Circular-Aperture Blackbody Radiation Source
High temperature circular aperture black body radiation source for field calibration of missile and airborne radiometers
SEARCH · Search NASA
Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.
Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.
High temperature circular aperture black body radiation source for field calibration of missile and airborne radiometers
Cosmic ray electron spectrum indicates universal 3 degrees K black body radiation confinement to galactic disk
High energy primary electrons and universal body radiation
Conflict between cosmic X ray and gamma ray background and black body interpretation of microwave background
Diffuse cosmic X rays produced by Compton scattering of far IR radiation on cosmic ray electrons
If relict gravitational waves deriving from a chaotic initial singularity contain a nonisotropic component, then this radiation can produce a frame dragging; effect which will induce a dipole anisotropy in the observed temperature distribution of the 3 K electromagnetic radiation background. The measured dipole and quadrupole distributions of the electromagnetic background can thus be used to bound the effective wave parameters of the nonisotropic part of the gravitational background. Using available data, the dimensionless amplitude of this nonisotropic part is found to be less than 0.0005 for wavelengths less than the Hubble radius. The effective energy density of this nonisotropic component of the gravitational radiation background is less than 2 x 10 to the -8th times the critical density.
Operating temperatures range from ambient down to minus 100 degrees C. V-grooved front face of source body blackened and recessed in black sleeve. Semiairtight chamber that houses source purged with dry nitrogen gas to prevent formation of dew or frost at low operating temperature.
Consideration of equilibrium radiation of plasma-like media shows that the spectral distribution of such radiation differs from that of Planckian equilibrium radiation (blackbody radiation). The physical reason for this difference consists in the impossibility of propagation of photons with the dispersion law {omega} = ck in systems of charged particles. The thermodynamics of equilibrium electromagnetic radiation in plasma is also considered. It is shown that the difference of the thermodynamic properties of such radiation from those of Planckian radiation is characterized by the parameter a = h{Omega}{sub p}/T. This difference is especially pronounced in plasma media in which a {>=} 1. Applications of the results obtained to plasmas of metals (first of all, liquid metals in which charged particles have no distant order) and to the plasma model of the early Universe are discussed.
The goal of this program was to incorporate two new and innovative design concepts into the design and production of CPV cells that have near zero added cost, yet significantly increase the operational efficiency of CPV modules. The program focused developing luminescent coupling effects and radiative cooling layers to increase efficiency and suppress CPV module power losses due to spectral variations and heating. The major results of the program were: 1) The optics of three commercial refractive (Fresnel) concentrators were characterized and prevent application of radiative cooling concepts due to strong mid-IR absorption (4-12µm) required to effectively radiate blackbody radiation from the cells and provide cooling. Investigation of alternative materials for the concentrator lenses produced only undesirable options—materials with reasonable mid-IR transmission for cooling only had about 30-40 visible transmission, thus reducing incident sunlight by >50%. While our investigation was somewhat limited, our work suggests that the only viable concentrator system that can incorporate radiative cooling utilizes reflective optics. 2) With limited ability to test high concentration CPV cells (requires outdoor testing), we acquired both semi-crystalline and crystalline Si cells and tested them in our outdoor facility and demonstrated 4°C cooling using a simple silica layer coating on the cells. 3) Characterizing Si cells in the IR associated with radiative cooling, we observed very significant near-IR absorption that increases the cell operating temperature by a similar amount, 4-5°C. By appropriate surface layer design, one can produce a layer that is highly reflective in the near-IR (1.5-4µm) and highly emissive in the mid-IR (5-15µm), thus reducing cell operational temperature by 10°C and increasing efficiency by ~1% absolute. The radiative cooling effect in c-Si solar cells might be further improved by providing a higher thermal conductive elastomer for securing the cover glass on top of the AR-coating. Since it was never imagined that the front surface would provide any cooling for solar cells, thermal conductivity of this elastomer was never a design consideration, but, improving the conductivity could decrease cell temperature by another 3-4°C. The combined effect could be an ~1.5% absolute increase in cell and module efficiency, a very significant improvement. 4) Developed a numerical model to explore dependence of luminescent coupling efficiency over a broad range of operating conditions. We developed a novel method and facility to experimentally measure the luminescent coupling that can be used to confirm the dependence of luminescent coupling on multi-junction cell design parameters.
There are insufficient super-soft ({approx}0.1 keV) X-ray sources in either spiral or elliptical galaxies to account for the rate of explosion of Type Ia supernovae (SNe Ia) in either the single-degenerate or the double-degenerate scenarios. We quantify the amount of circumstellar matter that would be required to suppress the soft X-ray flux by yielding a column density in excess of 10{sup 23} cm{sup -2}. We summarize evidence that appropriate quantities of matter are extant in SNe Ia and in recurrent novae that may be supernova precursors. The obscuring matter is likely to have a large, but not complete, covering factor and to be substantially non-spherically symmetric. Assuming that much of the absorbed X-ray flux is re-radiated as blackbody radiation in the UV, we estimate that {approx}<100 sources might be detectable in the Galaxy Evolution Explorer All-sky Survey.
Spectral irradiance is a fundamental radiometric unit. Its application to measurement results requires qualified traceability to basic units of the international system of units (Systeme international d'unites, SI). The Physikalisch-Technische Bundesanstalt (PTB) is amongst other national metrological institutes (NMIs) responsible for the realization, maintenance and dissemination of various radiometric and photometric units based on and traceable to national standards. The unit of spectral irradiance is realized and represented by a blackbody-radiator as the national primary standard of the PTB. Based on Planck's radiation law, the irradiance is calculated and realized for any wavelength taking into account the exact knowledge of the radiation temperature and the geometrical parameters. Using a double-monochromator-based spectroradiometer system, secondary standard lamps can be calibrated by direct comparison to the blackbody-radiator (substitution method). These secondary standard lamps are then used at the PTB to calibrate standard lamps of customers. The customers themselves use these so-called transfer standards to calibrate their working standard lamps. These working standards are then used to calibrate own spectroradiometers or sources. This rather complex calibration chain is a common procedural method that for the customers generally leads to satisfying measurement results on site. Nevertheless, the standard lamps in use have to fulfill highest requirements concerning stability and reproducibility. Only this allows achieving comparably low transfer measurement uncertainties, which occur at each calibration step. Thus, the PTB is constantly investigating the improvement and further development of transfer standards and measurement methods for various spectral regions. The realization and dissemination of the spectral irradiance using the blackbody-radiator at the PTB is accomplished with worldwide approved minimized measurement uncertainties confirmed by international intercomparisons among NMIs. Ultimately, the spectral irradiance can be realized with expanded measurement uncertainties of far less than 1 % over a wide spectral range. Thus, for customers with high demands on low measurement uncertainties, it is possible to calibrate their working standards directly against the blackbody-radiator, taking into account the higher necessary effort. In special cases it is possible to calibrate the customer's spectroradiometric facilities directly in front of the blackbody-radiator. In the context of the European Metrology Research Project Traceability for surface spectral solar ultraviolet radiation, the traceability chain will be improved and adapted.
The Conical Scanning Submillimeter-wave Imaging Radiometer (CoSSIR) has been developed to study the application of submillimeter-wave radiometry for remote sensing of cirrus clouds and humidity sounding. Measurements of the global distribution of ice cloud mass and particle size are important for understanding the Earth s energy budget and for evaluating global climate models. The spatial variability and the wide variety of cloud particle shapes and sizes make ice clouds particularly difficult to measure. Ice clouds are essentially undetectable at microwave frequencies due to the low dielectric of ice and small size of the particles relative to wavelength. However, submillimeter wavelengths demonstrate significant response to the presence of ice clouds thus this frequency regime is applicable to measuring ice clouds. Another potentially viable application for submillimeter-wave radiometry is humidity and temperature sounding. The principle of sounding at submillimeter wavelengths is similar to that at microwavelengths. Submillimeter-wave radiometry has the advantage of achieving finer spatial resolution using a smaller antenna aperture which is an important consideration for spaceborne observatories. Submillimeter-wave radiometry also offers the potential of sounding over land and as a surrogate measurement for precipitation. CoSSIR is a new instrument to explore these applications. The CoSSIR is designed to fly aboard the ER-2 aircraft and its modest size (approximately 100 kg) permits it to be configured for other aircraft. A dual-axes gimbals mechanism provides conical, across-track, and along-track scanning capability. In its present configuration CoSSIR has fifteen channels between 183 GHz and 640 GHz. Three channels are centered about the 183 GHz water vapor absorption line, four channels are centered about the 380 GHz water vapor absorption line, and three dual-polarized channels are centered about the 487 GHz oxygen absorption line. Two channels are located in atmospheric windows at 220 GHz and 640 GHz. All channels are single-linear polarized with the exception of those near 487 GHz. Calibration is achieved by periodically observing two blackbody radiators; one blackbody is heated to approximately 325 K and the other is approximately 250 K during flight. Details of the instrument design as well as measurements from the Cirrus Regional Study of Tropical Anvils and Cirrus Layers - Florida Area Cirrus Experiment will be presented.
A thermal model for nanosecond pulsed laser ablation of Cu in one dimension and in ambient gas, He at 1 atm, is proposed in which equations concerning heat conduction in the target and gas dynamics in the plume are solved. These equations are coupled to each other through the energy and mass balances at interface between the target and the vapor and also Knudsen layer conditions. By assumption of local thermal equilibrium, Saha-Eggert equations are used to investigate plasma formation. The shielding effect of the plasma, due to photoionization and inverse bremsstrahlung processes, is considered. Bremsstrahlung and blackbody radiation and spectral emissions of the plasma are also investigated. Spatial and temporal distribution of the target temperature, number densities of Cu and He, pressure and temperature of the plume, bremsstrahlung and blackbody radiation, and also spectral emissions of Cu at three wavelengths (510, 516, and 521 nm) are obtained. Results show that the spectral power of Cu lines has the same pattern as CuI relative intensities from National Institute of Standard and Technology. Investigation of spatially integrated bremsstrahlung and blackbody radiation, and also Cu spectral emissions indicates that although in early times the bremsstrahlung radiation dominates the two other radiations, the Copper spectral emission is the dominant radiation in later times. It should be mentioned that the blackbody radiation has the least values in both time intervals. The results can be used for prediction of the optimum time and position of the spectral line emission, which is applicable in some time resolved spectroscopic techniques such as laser induced breakdown spectroscopy. Furthermore, the results suggest that for distinguishing between the spectral emission and the bremsstrahlung radiation, a spatially resolved spectroscopy can be used instead of the time resolved one.
This viewgraph presentation reviews the 1901 work in Planck's constant and blackbody radiation law and the 1916 Einstein rederivation of the blackbody radiation law. It also reviews Wien's law. It also presents equations that demonstrate the thermal balance between radiation and matter.
An approach to the optimization of the spectral power distribution of solid-state light sources with the tunable non-image forming photobiological effect on the human circadian rhythm is proposed. For tetrachromatic clusters of model narrow-band (direct-emission) light-emitting diodes (LEDs), the limiting tunability of the circadian action factor (CAF), which is the ratio of the circadian efficacy to luminous efficacy of radiation, was established as a function of constraining color fidelity and luminous efficacy of radiation. For constant correlated color temperatures (CCTs), the CAF of the LED clusters can be tuned above and below that of the corresponding blackbody radiators, whereas for variable CCT, the clusters can have circadian tunability covering that of a temperature-tunable blackbody radiator.
An apparatus denoted a laser image contrast enhancement system (LICES) increases the contrast with which one can view a target glowing with blackbody radiation (a white-hot object) against a background of blackbody radiation in a furnace at a temperature as high as approximately 1,500 C. The apparatus utilizes a combination of narrowband illumination, along with band-pass filtering and polarization filtering to pass illumination reflected by the target while suppressing blackbody light from both the object and its background.
In an effort to demonstrate the feasibility of a solar pumped laser concept, gain has been measured in a CO2-He laser medium optically pumped by blackbody radiation. Various gas mixtures of CO2 and He have been pumped by blackbody radiation emitted from an electrically heated oven. Using a CO2 laser as a probe, an optical gain coefficient of 1.8 x 10 to the -3rd/cm has been measured at 10.6 microns for a 9:1 CO2-He mixture at an oven temperature of about 1500 K, a gas temperature of about 400 K and a pressure of about 1 torr. This corresponds to a small signal gain coefficient when allowance is made for saturation effects due to the probe beam, in reasonable agreement with a theoretical value.
We propose a protection scheme of a superconducting microwave resonator to realize a hybrid quantum system, where cold neutral atoms are coupled with a single microwave photon through magnetic dipole interaction at an interface inductor. The evanescent field atom trap, such as a waveguide/nanofiber atom trap, brings both surface-scattered photons and absorption-induced broadband blackbody radiation which result in quasiparticles and a low quality factor at the resonator. A proposed multiband protection layer consists of pairs of two dielectric layers and a thin nanogrid conductive dielectric layer above the interface inductor. We show numerical simulations of quality factors and reflection/absorption spectra, indicating that the proposed multilayer structure can protect a lumped-element microwave resonator from optical photons and blackbody radiation while maintaining a reasonably high quality factor.