Search NASA⌕ Search

SEARCH · Search NASA

Results for “Backup”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 55 records · Page 3

Backup power or bill savings? How electricity tariffs impact residential solar-plus-storage usage in the United States

Adoption of paired solar-plus-storage systems has accelerated in recent years, driven by both the demand for backup power and a desire to manage utility bills. Tradeoffs between those two uses can arise through the reserve setting on the battery storage system, which serves to maintain a minimum state of charge in case of a power interruption. Our paper applies an economic framework to evaluate this tradeoff in terms of changes in bill savings and customer reliability value across reserve levels, considering how those tradeoffs depend on the underlying electricity rate structure and levels. The analysis is based on a representative set of load profiles, solar profiles, tariff designs, and stochastic power interruption events across ten different regions in the United States. We find that the opportunity cost of holding storage capacity in reserve, in terms of foregone bill reductions, outweighs any gains in reliability value from mitigated power interruptions in the majority of customer situations. Higher storage reserve levels increase total customer value only in specific circumstances, such as for customers with inferior reliability (10x average interruptions), with a very high value of lost load ($50/kWh), and with tariff or interconnection rules that disallow grid charging. However, even this result is dampened when considering tariff designs with higher price differentials that increase the opportunity cost of holding storage in reserve (e.g. import/export or time-of-use rates). Allowing grid charging in tariffs essentially eliminates the necessity to hold any storage in reserve in all sensitivity cases explored.

Electric resilience↗

Optimized Heat Pipe Backup Cooling System Tested with a Stirling Convertor

Advanced Stirling Radioisotope Generator (ASRG) is an attractive energy system for select space missions, and with the addition of a VCHP, it becomes even more versatile. The ASRG is powered through thermal energy from decaying radioisotopes acting as General Purpose Heat Sources (GPHS). A Stirling engine converts the thermal energy to electrical energy and cools the GPHS [2]. The Stirling convertor must operate continuously to maintain acceptable temperatures of the GPHS and protect their cladding. The addition of alkali metal VCHP allows the Stirling to cycle on and off during a mission and can be used as a backup cooling system. The benefits of being able to turn the Stirling off are: allowing for a restart of the Stirling and reducing vibrations for sensitive measurements. The VCHP addition should also increase the efficiency of the Stirling by providing a uniform temperature distribution at the heat transfer interface into the heater head.

Stirling Radioisotope Generator↗

Technoeconomic analysis of hydrogen storage using 1,4-butanediol (BDO)/γ-butyrolactone (GBL) as a stationary backup power system

Liquid organic hydrogen carriers (LOHCs) are compounds that store and release hydrogen in stable forms at high density. While one-way carriers such as methanol and ammonia have gained attention, their economic advantages are often realized from their use as an export product and direct use as a fuel. Liquid carrier materials that can instead be cycled for energy storage have promise for stationary power applications. In particular, the reversible LOHC system 1,4-butanediol (BDO, H 2 -rich) and gamma-butyrolactone (GBL, H 2 -lean) has a lower enthalpy of dehydrogenation compared to conventional cyclic hydrocarbons and can utilize non-precious metal copper-based catalysts. Here, in this study, BDO/GBL system capital and operating expenses are characterized for vapor phase versus liquid phase hydrogenation and dehydrogenation in a 10 MW backup power application corresponding to sizing of Tier 2 datacenters as well as other critical infrastructure such as hospitals. Costs are benchmarked against two incumbent technologies: a well-established methylcyclohexane/toluene carrier system and compressed gas storage. BDO/GBL storage costs are found to differ substantially between operating modes, with liquid phase hydrogenation coupled with liquid phase dehydrogenation leading to the lowest LCOS of $\$$4.58/kg H 2 in the absence of byproduct formation. In this bounding case, LCOS for the BDO/GBL system is lower than for MCH/TOL ($\$$6.97/kg H 2 ) and compressed gas ($\$$8.48/kg H 2 at 170 bara and $\$$12.05/kg H 2 at 350 bara). However, escalating costs of carrier replacement due to byproduct formation (ranging from an added $\$$6–11/kg H 2 ) illustrate the need for highly selective catalysts to ensure BDO/GBL carrier viability.

BDO/GBL↗

Bill Savings vs. Backup Power: Evaluating operational tradeoffs for home solar+storage systems [Slides]

This study explores tradeoffs between the use of home solar+storage systems for backup power versus day-to-day utility bill savings. The study focuses specifically on the “reserve setting” available with most home battery storage systems, which allow the customer to maintain some minimum level of storage in reserve in case of an unforeseen power interruption. The more capacity that is held in reserve, the greater the customer’s ability to ride-through possible power interruptions, but less capacity is then available to manage utility bills on a day-to-day basis. This study evaluates this operational tradeoff across a diverse set of locations and residential electricity tariff structures, relying on Berkeley Lab’s PRESTO model to stochastically simulate power interruption events, and exploring a range of sensitivities, including variations in customer value of lost load (VoLL), interruption frequency, and other key drivers. The results show that, in most circumstances, the opportunity cost of holding storage capacity in reserve, in terms of foregone bill saving, tends to outweigh any gains in reliability value associated with mitigated power interruptions. This finding is robust across tariff structures and across most of the sensitivities considered, including those related to rate level, customer load level, and storage sizing. There are a limited set of circumstances where raising the reserve setting improves the overall customer value (comprised of bill savings plus reliability value). Specifically, that exception occurs when all of the following conditions apply: (a) the customer resides in a location with exceptionally poor reliability, (b) the customer has exceptionally high VoLL; (c) the customer is on a net billing rate or on a TOU rate that allows grid discharging but not grid charging; and (d), depending on the location, the price arbitrage differential on that rate is relatively small. In all other circumstances analyzed, total customer value declines with reserve level.

14 SOLAR ENERGY↗

The Backup Program of the Dark Energy Spectroscopic Instrument’s Milky Way Survey

The Milky Way Backup Program (MWBP), a survey currently underway with the Dark Energy Spectroscopic Instrument (DESI) on the Nicholas U. Mayall 4 m Telescope, works at the margins of the DESI Main surveys to obtain spectra of millions of additional stars from the Gaia catalog. Efficiently utilizing times between ∼12° and 18° twilight and poor weather conditions, the MWBP extends the range of stellar sources studied to both brighter magnitudes and lower Galactic latitude and declination than the stars studied in DESI’s Main Milky Way Survey. While the MWBP prioritizes candidate giant stars selected from the Gaia catalog (using color and parallax criteria), it also includes an unbiased sample of bright stars (i.e., 11.2 ≲ G < 16 mag) as well as fainter sources (to G ≲ 19 mag). As of 2025 March 1, the survey had obtained spectra of ∼7 million stars, approximately 1.2 million of which are included in the DESI Data Release 1. The DESI spectra cover the wavelength range from 3600 to 9800 Å at a resolution λ/Δλ varying from 2000 to 5000. The full survey, when completed, will cover an area of more than 21,000 deg 2 and include approximately 10 million Gaia sources, roughly equal to the number of stellar spectra obtained through the DESI Main Survey, while only utilizing ≈9% of all DESI observing time. This paper provides an overview of the MWBP, describing the target selection, observing strategy, and an introduction to the resulting data.

79 ASTRONOMY AND ASTROPHYSICS↗

Assessment of Energy Technology Options for the Island of Molokai, Hawaii: Analysis of Floating Solar, Pumped Storage Hydropower, and Backup Energy Systems [Slides]

This presentation summarizes analysis done by researchers at the National Laboratory of the Rockies and Pacific Northwest National Laboratory to evaluate the potential for and explore project concepts of electricity generation and storage additions on the island of Molokai, Hawaii, as identified in the Community Energy Resilience Action Plan (CERAP) by the Molokai Clean Energy Hui (MCEH), Sustainable Molokai, and the Hawaii Natural Energy Institute (HNEI). These electricity generation and storage additions include distributed photovoltaics (PV), battery energy storage, and generators for critical facilities on the island that can provide backup energy to the facilities during grid disruptions and outages, a floating PV (FPV) system on Kualapuu Reservoir, and pumped storage hydropower (PSH) systems scaled to act as a significant or primary source of energy storage on the Molokai grid. This presentation accompanies the full technical report published under the same title.

14 SOLAR ENERGY↗

Assessment of Energy Technology Options for the Island of Molokai, Hawaii: Analysis of Floating Solar, Pumped Storage Hydropower, and Backup Energy Systems

This report documents analysis done by researchers at the National Laboratory of the Rockies and Pacific Northwest National Laboratory to evaluate the potential for and explore project concepts of electricity generation and storage additions on the island of Molokai, Hawaii, as identified in the Community Energy Resilience Action Plan (CERAP) by the Molokai Clean Energy Hui (MCEH), Sustainable Molokai, and the Hawaii Natural Energy Institute (HNEI). These electricity generation and storage additions include distributed photovoltaics (PV), battery energy storage, and generators for critical facilities on the island that can provide backup energy to the facilities during grid disruptions and outages, a floating PV (FPV) system on Kualapuu Reservoir, and pumped storage hydropower (PSH) systems scaled to act as a significant or primary source of energy storage on the Molokai grid.

13 HYDRO ENERGY↗

Vacuum-type backup bar speeds weld repairs

A backup bar designed to use both vacuum and air pressure provides a method of sealing the weld root of a faulty section of seam weld. With slight redesign, the bar can be made sufficiently flexible to fit any large cylindrical surface.

Carmody, R. J.↗

Quick-acting backup tool for welding ducts

Alignment and backup tool facilitates butt welding of large-diameter ducts. It consists of a circular three-place segmented hoop, a pneumatic piston, and two shoes.

Johnson, L. L.↗

Magnetic gear backup

Backup clutch for magnetic gear operates only in case of slippage. Contacting a pin arrangement in the driven gear, the clutch provides extra force for continuing output. It does not interfere with normal, noncontact action.

Shefke, R. A.↗