Search NASASearch

SEARCH · Search NASA

Results for “Battery Testing”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 55 records · Page 3

The use of a tracking test battery in the quantitative evaluation of neurological function

A number of tracking tasks that have proven useful to control engineers and psychologists measuring skilled performance have been evaluated for clinical use. Normal subjects as well as patients with previous diagnoses of Parkinson's disease, multiple sclerosis, and cerebral palsy were used in the evaluation. The tests that were studied included step tracking, random tracking, and critical tracking. The results of the present experiments encourage the continued use of tracking tasks as assessment precedures in a clinical environment. They have proven to be reliable, valid, and sensitive measures of neurological function.

Repa, B. S.

Multimission modular spacecraft parallel battery tests

An engineering evaluation of the Multimission Modular Spacecraft power supply is presented. The spacecraft has one charger with eight commandable voltage versus temperature levels. Graphs are presented which represent: (1) cell voltage limits vs. temperature; (2) charge ratio vs. temperature; (3) effect of 0.0 percent impedance unbalance at 10 C; (4) shorted cell at 10 C; and (5) discharge voltage profile at 10 C.

Palandati, C.

Multimission modular spacecraft parallel battery tests

Acceptance test data included: voltage profiles; pressure increase or decrease; and response of the third electrode cell. A softening of the voltage profile was revealed, as well as a lowering of the discharge profile and a 10 percent loss of capacity over a 0 to 20 C temperature range.

Tasevoli, M.

Galileo battery testing and the impact of test automation

Test complexity, changes of test specifications, and the demand for tight control of tests led to the development of automated testing used for Galileo and other projects. The use of standardized interfacing, i.e., IEEE-488, with desktop computers and test instruments, resulted in greater reliability, repeatability, and accuracy of both control and data reporting. Increased flexibility of test programming has reduced costs by permitting a wide spectrum of test requirements at one station rather than many stations.

Pertuch, W. T.

Hubble space telescope six-battery test bed

A test bed for a large space power system breadboard for the Hubble Space Telescope (HST) was designed and built to test the system under simulated orbital conditions. A discussion of the data acquisition and control subsystems designed to provide for continuous 24 hr per day operation and a general overview of the test bed is presented. The data acquisition and control subsystems provided the necessary monitoring and protection to assure safe shutdown with protection of test articles in case of loss of power or equipment failure over the life of the test (up to 5 years).

Pajak, J. A.

Development of a standardized battery of performance tests for the assessment of noise stress effects

A set of 36 relatively independent categories of human performance were identified. These categories encompass human performance in the cognitive, perceptual, and psychomotor areas, and include diagnostic measures and sensitive performance metrics. Then a prototype standardized test battery was constructed, and research was conducted to obtain information on the sensitivity of the tests to stress, the sensitivity of selected categories of performance degradation, the time course of stress effects on each of the selected tests, and the learning curves associated with each test. A research project utilizing a three factor partially repeated analysis of covariance design was conducted in which 60 male subjects were exposed to variations in noise level and quality during performance testing. Effects of randomly intermittent noise on performance of the reaction time tests were observed, but most of the other performance tests showed consistent stability. The results of 14 analyses of covariance of the data taken from the performance of the 60 subjects on the prototype standardized test battery provided information which will enable the final development and test of a standardized test battery and the associated development of differential sensitivity metrics and diagnostic classificatory system.

Theologus, G. C.

The use of a battery of tracking tests in the quantitative evaluation of neurological function

A tracking test battery has been applied in a drug trail designed to compare the efficacy of L-DOPA and amantadine to that of L-DOPA and placebo in the treatment of 28 patients with Parkinson's disease. The drug trial provided an ideal opportunity for objectively evaluating the usefulness of tracking tests in assessing changes in neurologic function. Evaluating changes in patient performance resulting from disease progression and controlled clinical trials is of great importance in establishing effective treatment programs.

Repa, B. S.

Laboratory discharge studies of a 6 V alkaline lantern-type battery Eveready Energizer no. 528, under various ambient temperatures (-15 deg C and + 22 deg C) and loads (30 omega and 60 omega)

The voltages of two Eveready No. 528 batteries, one the test battery, the other the control battery, were simultaneously recorded as they were discharged across 30 omega loads using a dual chart recorder. The test battery was initially put in a freezer at -15 + or - 3 C. After its voltage had fallen to .6 V, it was brought back out into the room at 22 + or - 3 C. A second run was made with 60 omega loads. Assuming a 3.0 V cut-off, the total energy output of the test battery at -15 C was 26 WHr 30 omega and 35 WHr 60 omega, and the corresponding numbers for the control battery at 22 C were 91 WHr and 100 WHr. When the test battery was subsequently allowed to warm up, the voltage rose above 4 V and the total energy output rose to 80 WHr 30 omega and 82 WHR 60 omega.

Ahrens, S. T.

Mariner Mars 1971 battery design, test, and flight performance

The design, integration, fabrication, test results, and flight performance of the battery system for the Mariner Mars spacecraft launched in May 1971 are presented. The battery consists of 26 20-Ah hermetically sealed nickel-cadmium cells housed in a machined magnesium chassis. The battery package weighs 29.5 kg and is unique in that the chassis also serves as part of the spacecraft structure. Active thermal control is accomplished by louvers mounted to the battery baseplate. Battery charge is accomplished by C/10 and C/30 constant current chargers. The switch from the high-rate to low-rate charge is automatic, based on terminal voltage. Additional control is possible by ground command or onboard computer. The performance data from the flight battery is compared to the data from various battery tests in the laboratory. Flight battery data was predictable based on ground test data.

Bogner, R. S.

Ground Handling of Batteries at Test and Launch-site Facilities

Ground handling of flight as well as engineering batteries at test facilities and launch-site facilities is a safety critical process. Test equipment interfacing with the batteries should have the required controls to prevent a hazardous failure of the batteries. Test equipment failures should not induce catastrophic failures on the batteries. Transportation requirements for batteries should also be taken into consideration for safe transportation. This viewgraph presentation includes information on the safe handling of batteries for ground processing at test facilities as well as launch-site facilities.

Jeevarajan, Judith A.

Low-Earth-Orbit and Geosynchronous-Earth-Orbit Testing of 80 Ah Batteries under Real-Time Profiles

To date the LEO battery has completed 5000 nominal cycles.The EODV is trending down by 50mV per 1000 cycles. To date the GEO battery has completed 2 nominal shadow periods and currently in sunlight period. Batteries testing after one year looks encouraging for aerospace application. There are no discrepancies between the current data and extensive testing conducted at Saft over the past 5 years.

Staniewicz, Robert J.

Reserve Li/SOC12 Battery Safety Testing

A reserve Lithium/Thionyl Chloride Battery concept is developed and undergoing feasibility testing in terms of performance, safety and abusive conditions. The feasibility of employing a battery of this type to replace thermal batteries in certain applications is demonstrated. Excellent performance of a Li/SOCl2 reserve battery is obtained across the temperature range from 0 C to +44 C. Performance improvement over the thermal battery usage is greater by a factor of 3 when discharge time and energy density are compared. Performance over an expanded temperature range is also possible. Safety and abusive testing is accomplished successfully on a series of five units. Further performance improvements can be achieved with regard to battery weight and volume reductions.

Dils, C. T.

Evaluation of tests for vestibular function

Vestibular testing methodologies are examined in terms of their clinical value and applicability to the assessment of astronaut candidates and human responses to microgravity. Classical and novel testing approaches are examined in terms of nine functions such as otolith organs, vestibular neural processing, and ocular motor systems. The tests reviewed include the basic vestibular-function test battery, postural stability testing, visual-vestibular interaction, reactions to off-axis rotation, and vestibular evoked responses. The basic test battery is shown to be essential for astronaut and inertial-environment baseline-data evaluations, whereas the newer and research tests are only recommended in special cases. Stimulus rearrangement and motion-sickness tests are indicated for testing adaptation to inertial environments. Postural stability and visual-vestibular interaction are recommended for evaluating one's suitability for being an astronaut.

Source record

Life test of a nickel cadmium battery with a protection/reconditioning circuit

Results are discussed for a Ni-Cd battery test over a period of 8 years, 2 months and 44,213 simulated low Earth orbits. The battery cells were protected against overdischarge and reversal at discharge rates up to 25 amperes (1.25C) by a battery protection and reconditioning circuit. The circuit performed flawlessly during the test, and proved its value, both as a battery reconditioner and a cell protection device. Battery cell failures are also discussed. The test demonstrated the viability of using Ni-Cd batteries at depth-of-discharge up to 25 percent for over 5 years in a low Earth orbit.

Lanier, J. R., Jr.

Battery life test using reconditioning

A discussion is presented on nickel cadmium battery life tests using reconditioning and some comparative tests not using reconditioning. The discussion is aimed at the program application part of the testing. The goals of the program were to get an increased utilization out of the battery system in geosynchronous orbit. An attempt was made to push the depth of discharge operation up around 80 to 85 percent and the intent with the reconditioning program was to extend this type of utilization out towards a 10-year life and attune the voltage regulation.

Sparks, R. H.