Search NASA⌕ Search

SEARCH · Search NASA

Results for “Battery sizing optimization”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 55 records · Page 3

An Optimization Model for Plug-In Hybrid Electric Vehicles

The necessity for environmentally conscious vehicle designs in conjunction with increasing concerns regarding U.S. dependency on foreign oil and climate change have induced significant investment towards enhancing the propulsion portfolio with new technologies. More recently, plug-in hybrid electric vehicles (PHEVs) have held great intuitive appeal and have attracted considerable attention. PHEVs have the potential to reduce petroleum consumption and greenhouse gas (GHG) emissions in the commercial transportation sector. They are especially appealing in situations where daily commuting is within a small amount of miles with excessive stop-and-go driving. The research effort outlined in this paper aims to investigate the implications of motor/generator and battery size on fuel economy and GHG emissions in a medium-duty PHEV. An optimization framework is developed and applied to two different parallel powertrain configurations, e.g., pre-transmission and post-transmission, to derive the optimal design with respect to motor/generator and battery size. A comparison between the conventional and PHEV configurations with equivalent size and performance under the same driving conditions is conducted, thus allowing an assessment of the fuel economy and GHG emissions potential improvement. The post-transmission parallel configuration yields higher fuel economy and less GHG emissions compared to pre-transmission configuration partly attributable to the enhanced regenerative braking efficiency.

02 PETROLEUM↗

An economic assessment of behind-the-meter photovoltaics paired with batteries on the Hawaiian Islands.

Due to natural variability and uncertainty, the ever-increasing penetration of solar generation in Hawaii presents challenges to power grid operators to maintain reliable system operation. Demand response (DR) has the potential to be a cost-effective tool for Hawaii to reach its aggressive renewable energy goals while maintaining the reliability of power grids. The Hawaii Public Utilities Commission has approved the Hawaiian Electric Company's revised portfolio of DR programs. The companies have released a grid services purchase agreement and subscribed an initial tranche of load into their DR programs. This paper presents innovative analytical methods and comprehensive economic assessment for distributed photovoltaics (PV) paired with battery energy storage systems (BESSs) for two new DR programs, including fast frequency response and capacity grid service. Optimal dispatch and sizing methods are proposed for the paired system considering different tariff schedules and PV compensation programs across five islands. It was found that while the best resource configuration and potential economic benefits vary with tariff structure, a BESS paired with PV can be optimally dispatched to generate multiple value streams simultaneously. Compensation from DR programs is an important value stream to help increase the cost-effectiveness of the integrated system.

Battery energy storage system↗

Electrified Automotive Powertrain Architecture Using Composite DC–DC Converters

In a hybrid or electric vehicle powertrain, a boost dc-dc converter enables reduction of the size of the electric machine and optimization of the battery system. Design of the powertrain boost converter is challenging because the converter must be rated at high peak power, while efficiency at medium-to-light load is critical for the vehicle system performance. By addressing only some of the loss mechanisms, previously proposed efficiency improvement approaches offer limited improvements in size, cost, and efficiency tradeoffs. This article shows how all dominant loss mechanisms in automotive powertrain applications can be mitigated using a new boost composite converter approach. In the composite dc-dc architecture, the loss mechanisms associated with indirect power conversion are addressed explicitly, resulting in fundamental efficiency improvements over wide ranges of operating conditions. Several composite converter topologies are presented and compared to state-of-the-art boost converter technologies. It is found that the selected boost composite converter results in a decrease in the total loss by a factor of 2-4 for typical drive cycles. Furthermore, the total system capacitor power rating and energy rating are substantially reduced, which implies potentials for significant reductions in system size and cost.

25 ENERGY STORAGE↗

Economic Analysis of On-Route Fast Charging for Battery Electric Buses: Case Study in Utah

Battery electric buses (BEBs) are increasingly being embraced by transit agencies as an energy-efficient and emission-free alternative to bus fleets. However, because of the limitations of battery technology, BEBs suffer from limited driving range, great battery cost, and time-consuming charging processes. On-route fast charging technology is gaining popularity as a remedy, reducing battery cost, extending driving range, and reducing charging time. With on-route fast charging, BEBs are as capable as their diesel counterparts in relation to range and operating time. However, transit agencies may have the following concerns about on-route fast charging: 1) on-route fast charging stations require massive capital costs; 2) on-route fast charging may lead to high electricity power demand charges; and 3) charging during peak hours may increase electricity energy charges. This study conducts a quantitative economic analysis of on-route fast charging for BEBs, thereby providing some guidelines for transit agencies. An integrated optimization model is first proposed to determine battery size, charger type, and recharging schedule for a general BEB route. Based on the model, an economic analysis of on-route fast charging is then performed on 10 real-world bus routes and a simplified general bus route with different parameters. The results demonstrate that given the current prices of on-route fast charging stations and batteries, it is always beneficial to install on-route fast charging stations for BEBs. A sensitivity analysis is also conducted to show the impact of potential price reductions of batteries.

Engineering↗

Optimization of Energy Storage System Economics and Controls by Incorporating Battery Degradation Costs in REopt

The use of stationary electrochemical energy storage systems utilizing lithium-ion batteries has increased rapidly as the production scale and price for lithium-ion batteries has decreased. These energy storage systems are crucial for maintaining grid resiliency, especially for grids operating with high penetration of renewable energy generation assets or for with a variety of distributed energy generation and storage systems. One challenging factor for the development of battery energy storage systems is estimating the proper sizing, in terms of both power and energy, that minimizes total costs over the lifetime of the systems; this calculation is difficult in simple cases, where a battery is costed independently, but is extremely challenging when building loads and electrical generation by photovoltaic resources are also considered. REopt is a techoeconomic optimization tool developed by NREL to address these challenges. Previously, battery degradation has been priced by simply assuming a 10-year replacement schedule for battery systems. However, this does not account for varying degradation trends observed across real-world batteries, or allow for batteries to be operated in a degradation-aware manner that optimizes battery dispatch based on operating costs. This work incorporates a battery life model into REopt. This battery life model is simple, so that it may be solvable within the constrains of a mixed-integer linear optimization problem, but is fit to accelerated aging data recorded in the lab. To achieve the best possible accuracy for lifetime estimates given these constraints, parameters for the battery life model in REopt are estimated by fitting 20-year simulations of battery life after identifying state-space battery degradation model from accelerated aging data. Comparisons of battery life predicted in REopt and from the state-space battery degradation model to ensure validity of lifetime estimates made by REopt. Battery life and cost is optimized by controlling three decision to minimize system life cost: battery sizing, daily state-of-charge, and daily energy-throughput. The cost of battery degradation as a function of these control variables is then estimated assuming two possible maintenance strategies: replacement, where the entire battery system is replaced if cell reach an end-of-life capacity threshold; and augmentation, which establishes a fund to pay for continual purchase of new batteries to maintain the initial energy capacity of the system. These two strategies offer conservative (for replacement) and optimistic (for augmentation) bounds for total system cost. The degradation cost incurred by these strategies is then used to control battery dispatch decisions, operating the battery in a degradation-aware manner that maximizes battery lifetime while also providing energy when favorable. Because the mixed-integer linear program has perfect foresight of future energy needs, batteries with degradation costs are always operated using 'just-in-time' charging, which is unrealistic, as no energy is left in the storage system to perform other energy services or to serve as emergency back-up power. To combat this, an inequality constraint on the average annual state-of-charge is imposed, and the sensitivity of system cost to average stored energy, e.g., the cost of system resiliency, can be quantified. Analysis of results has several conclusions, for instance, oversizing of battery storage systems is not a cost burden when battery storage is an optimal solution, as any additional battery capacity can simply be utilized to avoid costs of purchasing energy from a utility.

battery↗

Cylindrical battery design app

Software that delivers optimal design parameters and performance predictions for cylindrical cells, which can range in size from microbatteries to EV batteries, is developed. The software utilizes machine learning and includes a graphical user interface to enable rapid prototyping and to accelerate energy storage research, development, and manufacturing. The Cylindrical battery design V1.0 comprises of three types of cylindrical batteries, Microbattery (Primary), Microbattery (Secondary) and 18650/21700/xxxxx Cylindrical battery. The software was developed in MATLAB. The software has the capability to output the cell design with the capacity ranges from several mAh to several million Ah.

Xiao, Jie↗

Behind the Meter Storage for Electric Vehicle Charging, Electrochemical and Thermal Energy Storage, and Solar Photovoltaic

In response to the potentially large and irregular demand from EVs, along with changing load profiles from buildings with on-site generation, utilities are evaluating multiple options for managing dynamic loads, including time-of-use pricing, demand charges, battery storage, and curtailment of variable generation. Buildings, as well as commercial, public, and workplace EV charging operations, can use a combination of electrochemical battery storage and thermal energy storage coupled with on-site generation to manage energy costs as well as provide resiliency and reliability for EV charging and building energy loads. We are completing a behind the meter storage analysis that focuses on determining the optimal system designs and energy flows for thermal and electrochemical behind the meter storage with on-site solar photovoltaic (PV) generation enabling electric vehicle charging in various climates, building types, and utility rate structures. In completing this analysis, we have developed a tool that combines existing battery models via the System Advisor Model (SAM) and building modeling software via EnergyPlus into a single interface. This tool allows us to simulate a building with a detailed battery model to properly size the battery, thermal energy storage, and solar PV systems to maximize profit for the system owner. This also allows us to assess how the battery degrades under various supervisory control dispatch algorithms to control charging/discharging; we can also see how thermal energy storage is created and used to complement the battery to reduce thermal loads in the building. With this project, we can analyze new batteries that are designed specifically for energy storage, rather than designed to be extremely energy dense for electric vehicle applications, using battery lifetime models from other national labs and the existing SAM battery model, which has detailed lifetime and degradation parameters. We can also assess novel thermal storage technologies by integrating them into the whole building energy simulation program EnergyPlus. Because the model calls both SAM and EnergyPlus, required inputs need to be compatible for both models. These inputs include, on a high-level, the following: weather files, building and electric vehicle load profiles, electricity rate tariff information, and system cost information for the stationary battery, solar PV, and thermal storage system. The various buildings we are studying for this analysis are retail big-box grocery store, commercial office building, fleet vehicle depot and operations facility, multi-family residential, and electric vehicle charging station. For these different applications, the battery and thermal storage will be dispatched differently, and the various technologies are sized differently to optimize cost.

30 DIRECT ENERGY CONVERSION↗

Machine Learning Software for Cylindrical Battery Design and Performance Prediction

A software that delivers optimal design parameters and performance predictions for cylindrical cells, which can range in size from micro batteries to EV batteries, is developed. The Cylindrical battery design V1.0 is comprised of three types of cylindrical batteries, Micro battery (Primary), Micro battery (Secondary) and 18650/21700/xxxxx cylindrical battery. The software was developed in MATLAB. The software has the capability to output the cell design with the capacity ranges from several mAh to several million Ah. The software utilizes machine learning and includes a graphical user interface to enable rapid prototyping to accelerate energy storage research, development, and manufacturing.

25 ENERGY STORAGE↗

REopt: Enabling Renewable Energy, Storage, and Combined Heat and Power

Deployment of distributed energy resources including combined heat and power (CHP), photovoltaics (PV), and battery storage is growing as building and campus owners seek to reduce energy costs and increase resilience to grid outages. While deployment of a single technology is widespread, integrated systems of multiple technologies are also becoming more common to provide maximum economic and resilience benefits. To accelerate deployment, decision makers require tools to evaluate the technical and economic feasibility of these integrated systems. This paper presents a framework for optimizing the size and dispatch strategy of CHP with PV and battery storage to minimize life-cycle cost of energy. The modeling methodology is presented, with a particular focus on the linearization of cost and performance metrics required for implementation in a mixed integer linear program. A case study is used to examine the technical and economic viability of integrated CHP, PV, and battery systems, compared to CHP-only or PV+battery storage systems. In the case study we show how the integrated systems can provide increased economic and resilience benefits compared to single technologies on their own. The case study presented shows the combined CHP, PV, and battery system resulted in a 7% lower life cycle cost than CHP only, and a 22% lower life cycle cost than PV+battery storage. The life cycle emissions for CHP, PV, and battery storage resulted in a 24% reduction than CHP only and a 17% increase than PV+battery storage.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Control and Optimization of Energy Storage System in Power Distribution System

The widespread adoption of electric vehicles (EVs) and transportation electrification is encumbered by two chief barriers: i) the limited driving range of EVs in the market today and ii) inadequate fast-charging infrastructure for long-distance trips. Extreme fast charging (XFC) technology can recharge EVs in less than 10 minutes for 200 miles range. Firstly, a novel robust optimization-based mixed integer linear programming model is proposed to size a battery energy storage system (BESS) and PV system in an XFCS. In this part, it is assumed that the sizing and location of the XFCS are known. Secondly, the aforesaid assumption is relaxed, and a strategic multi-period coordinated planning model is proposed to optimally site and size BESS-assisted charging stations in a highway transportation network and PV systems in a power distribution network by considering the coupling between both networks. Optimal operation and control of BESS-assisted EV charging stations are vital to alleviate the adverse impact of extreme fast charging of EVs on the host power network. A joint solution is proposed to mitigate the steady state and transient impact of extremefast charging of EVs and ensure grid-friendly integration of XFCSs with the host grid. Lastly, to make the operation of the XFCS cost-effective, a multi-layered energy management framework is proposed for the XFCS by considering forecast uncertainties, monthly demand charges reduction, and BESS degradation.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Optimization of mesoporous carbon structures for lithium–sulfur battery applications

Mesoporous carbon (MC) with tunable pore sizes (22nm, 12nm, 7nm, and 3nm) and pore volumes (from 1.3 to 4.8 cc/g) containing sulfur inside the pores were systematically studied as mesoporous carbon-sulfur (MCS) composite electrodes for Li-S batteries. Investigation on these MCS composites reveals that the pore structure has no influence on the battery performance at full sulfur loading conditions (the pore volume is fully filled by sulfur) but the maximum sulfur loading capability is higher for MC with larger pore volume. MC with large pore volumes, partial sulfur filling (part of the pore volume left unfilled), and surface modification, can have reasonably high sulfur loading, improved electrical and ionic contacts of sulfur with MC and with electrolytes, which subsequently promotes the battery performance. An initial capacity of ~1250 mAh/g (based on sulfur) and 650 mAh/g capacity retention over 100 cycles were obtained with 50 wt% sulfur loading in the MC with 22nm pore size (4.8 cc/g). When the surface of MCS was coated with Clevios P to reduce the dissolve of polysulfide anions in electrolytes, it exhibits a high initial discharge capacity of ~1390 mAh/g and improved cycling stability with capacity retention of ~840 mAh/g over 100 cycles. The reported correlation among the structure, sulfur filling, surface modification and the electrochemical performance of the MCS composite cathodes provides guidance in designing new electrodes for lithium-sulfur batteries

25 ENERGY STORAGE↗

Data-Driven Energy Resilience Assessment and Enhancement in Urban Communities: A Case Study in Detroit

This paper presents a data-driven framework for assessing and enhancing energy resilience in urban communities. The resilience assessment is based on two datasets: 1) annual aggregated power outage data and 2) 15-minute interval outage data. High-impact, low-probability (HILP) events are identified within these datasets to evaluate community resilience under extreme conditions. To enhance resilience, an optimization framework utilizing mixed integer linear programming is developed to determine the optimal sizing and placement of solar photovoltaic (PV) systems and battery energy storage systems (BESS). This method offers a cost-effective and practical solution for improving energy resilience in vulnerable communities. Furthermore, a case study of the City of Detroit in Michigan demonstrates the effectiveness of the framework through simulation and validation.

Energy resilience assessment↗

Maintaining Adequate CO2 Washout for an Advanced EMU via a New Rapid Cycle Amine Technology

Over the past several years, NASA has realized tremendous progress in Extravehicular Activity (EVA) technology development. This has been evidenced by the progressive development of a new Rapic Cycle Amine (RCA) system for the Advanced Extravehicular Mobility Unit (AEMU) Portable Life Support Subsystem (PLSS). The PLSS is responsible for the life support of the crew member in the spacesuit. The RCA technology is responsible for carbon dioxide (CO2) and humidity control. Another aspect of the RCA is that it is on-back vacuum-regenerable, efficient, and reliable. The RCA also simplifies the PLSS schematic by eliminating the need for a condensing heat exchanger for humidity control in the current EMU. As development progresses on the RCA, it is important that the sizing be optimized so that the demand on the PLSS battery is minimized. As well, maintaining the CO2 washout at adequate levels during an EVA is an absolute requirement of the RCA and associated ventilation system. Testing has been underway in-house at NASA Johnson Space Center and analysis has been initiated to evaluate whether the technology provides exemplary performance in ensuring that the CO2 is removed sufficiently enough and the ventilation flow is adequate enough to maintain CO2 1 Project Engineer, Space Suit and Crew Survival Systems Branch, Crew and Thermal Systems Division, 2101 NASA Parkway, Houston, TX 77058/EC5. washout in the AEMU spacesuit helmet of the crew member during an EVA. This paper will review the recent developments of the RCA unit, the testing results performed in-house with a spacesuit simulator, and the associated analytical work along with insights from the medical aspect on the testing.

Chullen, Cinda↗

Maintaining Adequate CO2 Washout for an Advanced EMU via a New Rapid Cycle Amine Technology

Over the past several years, NASA has realized tremendous progress in Extravehicular Activity (EVA) technology development. This has been evidenced by the progressive development of a new Rapid Cycle Amine (RCA) system for the Advanced Extravehicular Mobility Unit (AEMU) Portable Life Support Subsystem (PLSS). The PLSS is responsible for the life support of the crew member in the spacesuit. The RCA technology is responsible for carbon dioxide (CO2) and humidity control. Another aspect of the RCA is that it is on-back vacuum-regenerable, efficient, and reliable. The RCA also simplifies the PLSS schematic by eliminating the need for a condensing heat exchanger for humidity control in the current EMU. As development progresses on the RCA, it is important that the sizing be optimized so that the demand on the PLSS battery is minimized. As well, maintaining the CO2 washout at adequate levels during an EVA is an absolute requirement of the RCA and associated ventilation system. Testing has been underway in-house at NASA Johnson Space Center and analysis has been initiated to evaluate whether the technology provides exemplary performance in ensuring that the CO2 is removed sufficiently and the ventilation flow is adequate for maintaining CO2 washout in the AEMU spacesuit helmet of the crew member during an EVA. This paper will review the recent developments of the RCA unit, testing planned in-house with a spacesuit simulator, and the associated analytical work along with insights from the medical aspect on the testing. 1

Chullen, Cinda↗

Optimized System for On-Route Fast Charging of Battery-Electric Shuttle Buses

Electrifying cars, buses, and trucks is an attractive means of reducing energy use and emissions because it involves more efficient drivetrain components and minimal restructuring of the transportation network. Transit buses, driving fixed routes, help minimize driver range anxiety by properly sizing energy storage systems. A major challenge to fully electrifying transit buses is providing the amount of energy they consume in a day of driving. To enable a full day of operation without charging, batteries need to be large, which could be expensive and heavy. This work utilizes real-world transit bus data used in a battery-electric drivetrain model to co-optimize charger locations, charger power levels, and vehicle battery sizes.

ADVANCED PROPULSION SYSTEMS↗

Optimal Sizing of Resilience Solutions for the U.S. Army Reserve

Power or water outages in buildings threaten the ability of the military to support surrounding communities during natural disasters. Outages can last for days, weeks or months. Typical solutions include very expensive batteries and onsite generation that are sized based on historical power needs. The U.S. Army Reserve (USAR) has teamed up with the Pacific Northwest National Laboratory (PNNL) to develop a simulation framework that optimizes future power needs to reduce the cost of resilience solutions. The approach starts with the building. Power needs during an emergency event are simulated at the building end-use level, then loads are reduced through the selection of life cycle cost-effective building-level technology improvements. These new optimized loads are then fed into a microgrid sizing tool that dynamically constructs many different combinations of solar photovoltaic, battery storage, and generator resources to meet the load for hundreds of statistically generated outage scenarios. Six site assessments completed by USAR and PNNL in 2019 have resulted in a 1-14% reduction in overall investment when optimizing the buildings first before determining the generation requirements. This approach helps the Army secure critical missions and provide a 14 day-minimum supply of necessary energy and water in the most efficient manner.

buidlings, efficiency, resilience, FEDS, MCOR↗

Savings in Action: Lessons from Observed and Modeled Residential Solar Plus Storage Systems

The electric grid is rapidly evolving as small-scale, demand-side resources play increasingly important roles in grid operations and decarbonization. Maximizing the potential of demand-side resources involves incentivizing electricity customers to use those resources in ways that benefit the broader electrical grid. These incentives depend largely on the electricity cost savings that customers can realize from demand-side resource adoption. Determining these potential cost savings is a complex task. Cost savings depend on numerous factors, including the characteristics of different technologies, the algorithms that control these devices, system performance, customer behavior, electricity rate structures, and climatic factors. Another challenge is that estimated cost savings are frequently based on modeled rather than observed system performance, particularly in the academic literature. In this study, we begin to fill the gap in empirical research of demand-side resources using data from a new construction residential community equipped with rooftop solar and storage (S+S) in Arizona. We use these data to analyze the factors that determine customer electricity cost savings and emissions impacts of S+S in the real world. We then compare these data to modeled system performance to understand how models deviate from real-world outcomes. Based on these findings, we explore ways to improve such models and, conversely, use modeled results to suggest improvements to actual S+S deployment. The results of these analyses can be summarized in four key findings: 1) rate structures play a central role in the grid and customer value of demand-side resources; 2) certain customers can benefit more from demand-side resource adoption than others; 3) modeled battery dispatch and sizing reveals opportunities for additional cost savings; and 4) optimal dispatches can reduce grid emissions while maximizing bill savings.

14 SOLAR ENERGY↗