Search NASA⌕ Search

SEARCH · Search NASA

Results for “Beamline”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 55 records · Page 3

IOTA Proton Injector Beamline Installation

The IOTA Proton Injector (IPI), currently under installation at the Fermilab Accelerator Science and Technology facility, is a beamline capable of delivering 20-mA pulses of protons at 2.5 MeV to the Integrable Optics Test Accelerator (IOTA) ring. First beam in the IPI beamline is anticipated in 2023, when it will operate alongside the existing electron injector beamline to facilitate further fundamental physics research and continued development of novel accelerator technologies in the IOTA ring. This report details the expected operational profile, known challenges, and the current state of installation.

43 PARTICLE ACCELERATORS↗

TRTR NRAD NRS Beamline Abstract

The Neutron Radiography (NRAD) Reactor is a 250kW TRIGA housed under the largest hot cell in the United States, making it the foremost location to perform neutron imaging of irradiated nuclear fuels and materials, including those intended for use with advanced reactors. Currently, NRAD has two radial beamlines that are used for neutron radiography and tomography. Upgrades to the North neutron beamline include the replacement of the in-tank beam chamber, through-the-wall collimator, and neutron shutter. These beamline upgrades will not only improve image quality for current capabilities but will also condition the beam to be more suitable for advanced methods such as neutron powder diffraction. These upgrades will increase the excess reactivity of the core, reduce unnecessary activation and exposure to workers, and significantly reduce the amount of shielding required around the beam. This presentation will describe how these upgrades improve beam quality, increase utilization of the reactor, and reduce radiation exposure to personnel.

21 - SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLAN↗

Advances in understanding vacuum break dynamics in liquid helium-cooled tubes for accelerator beamline applications

Understanding air propagation and condensation following a catastrophic vacuum break in particle accelerator beamlines cooled by liquid helium is essential for ensuring operational safety. This review summarizes experimental and theoretical work conducted in our cryogenics lab to address this issue. Systematic measurements were performed to study nitrogen gas propagation in uniform copper tubes cooled by both normal liquid helium (He I) and superfluid helium (He II). These experiments revealed a nearly exponential deceleration of the gas front, with stronger deceleration observed in He II-cooled tubes. To interpret these results, a one-dimensional (1D) theoretical model was developed, incorporating gas dynamics, heat transfer, and condensation mechanisms. The model successfully reproduced key experimental observations in the uniform tube system. However, recent experiments involving a bulky copper cavity designed to mimic the geometry of a superconducting radiofrequency (SRF) cavity revealed strong anisotropic flow patterns of nitrogen gas within the cavity, highlighting limitations in extrapolating results from simplified tube geometries to real accelerator beamlines. To address these complexities, we outline plans for systematic studies using tubes with multiple bulky cavities and the development of a two-dimensional (2D) model to simulate gas dynamics in these more intricate configurations. As a result, these efforts aim to provide a comprehensive understanding of vacuum breaks in particle accelerators and improve predictive capabilities for their operational safety.

Beamline tube↗

Status and new features of the topography beamline 1-BM after the Advanced Photon Source upgrade

The beamline 1-BM of the Advanced Photon Source (APS), a bending-magnet beamline with an effective X-ray beam size of ~100×4 mm2, has relatively comprehensive synchrotron topography and rocking curve imaging capabilities for characterization of crystals (particularly wide-bandgap semiconductors SiC, AlN, GaN, Ga2O3 etc). It is equipped with a white-beam topography stage for imaging large wafers up to 8 inches. It also has a double-crystal setup, of which the second stage can be used for monochromatic-beam topography. The first stage has different beam conditioners in the grazing-incidence geometry that can expand the vertical beam size from 4 to ~100 mm for double-crystal rocking curve imaging when it is combined with the second stage. Recently APS has been upgraded to a modern 4th-generation light source, and 1-BM has been recommissioned to its normal operation for general users with better performance. The upgraded APS leads to new features at 1-BM. The much smaller source size and higher X-ray coherence significantly improve the image resolution and contrast. The higher flux and brightness of the new source reduce exposure time, which mitigates the mechanical drifting and vibration issues. Here the main capabilities and status of 1-BM together with these new features are introduced.

X-ray topography↗

Radiation shielding analysis of the concrete hutch of a long beamline of the Advanced Photon Source Upgrade project

The radiation shielding analysis of the external concrete enclosure of a feature long beamline of the Advanced Photon Source Upgrade project is described in this work. The beamline has 2 undulators that can operate in two different configurations and the source terms are estimated for the worst configuration using the SRW code in the OASYS package as well as the STAC8 code. The shielding analysis is carried out using the STAC8 code, and for the case of pink beam, with the FLUKA code also. Effective dose rates on contact with the outside surface of the concrete walls for pink, reflected full spectrum and monochromatic beams are calculated. For the monochromatic beams, 2 sets of discrete bandwidths (BW) from the Double Crystal Monochromator (DCM) and the full reflectance of the Double Multilayer Monochromator (DMM) are used. Further, due to the size of the direct beam and the energy domain of interest in the direct and scattered fields, the importance of the equivalent dose to the lens of the eye is discussed with respect to the shielding calculations of such facilities. The dose rates outside the concrete hutch in the lateral directions calculated using STAC8 is about 50% higher than the FLUKA results for the case of pink beam but may be considered as a reasonable agreement due to the differences in the calculational methodologies. Those dose rates in the lateral and forward directions are higher for the pink beam to allow full occupancy from the radiation protection point of view. For the full spectrum after 3 reflections, the effective dose rates are less than 0.5 Sv/h in the lateral direction but is higher in the forward region below about 22° with respect to the beam direction. For the DCM beams, except for the scenario with one mirror and 0.1%BW, all dose rates are less than 0.5 Sv/h outside the concrete hutch in the lateral directions. Here, the higher harmonics are what contributes to the dose outside the shield and the bandwidths assumed to derive the photon flux thus becomes important. The dose rates with the DMM are generally lower compared to the 0.1% BW DCM beam but are higher than the results obtained with XOP calculated bandwidths.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Characterization of the new Ultracold Neutron beamline at the LANL UCN facility

The neutron electric dipole moment (nEDM) experiment that is currently being developed at Los Alamos National Laboratory (LANL) will use ultracold neutrons (UCN) and Ramsey’s method of separated oscillatory fields to search for a nEDM. Here, in this paper, we present measurements of UCN storage and UCN transport performed during the commissioning of a new beamline at the LANL UCN source and demonstrate a sufficient number of stored polarized UCN to achieve a statistical uncertainty of δd n = 2 x 10 -27 e cm in 5 calendar years of running. We also present an analytical model describing data that provides a simple parameterization of the input UCN energy spectrum on the new beamline.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Optical Design of $\mathrm{DEI/ABI}$ System at the $\mathrm{HEX}$ Beamline at the $\mathrm{NSLS-II}$

Diffraction Enhanced Imaging (DEI) or Analyzer Based Imaging (ABI) uses a perfect crystal monochromator and matching analyzer to achieve sensitivity to x-ray refraction and ultra small-angle scattering on the order of 0.01 micro-radians. As such, a thermal bump caused by heat-load in the order of 1 W is detrimental. The heat load at the HEX (High Energy Engineering X-ray) super-conducting wiggler (SCW) beamline, under construction at the NSLS-II, is on the order of 1 kW. How to reconcile the three orders of magnitude difference between the HEX source power and the DEI/ABI requirements? The solution involves using a double-crystal bent-Laue monochromator as pre-monochromator to prepare a beam with a large divergence and bandwidth that is matched to a flat crystal post-monochromator. We show through phase-space (x-ray energy vs. angle as viewed by a flat crystal) analysis and Dumond diagrams that there is indeed a unique bending radius that matches the double-crystal bent-Laue monochromator in phase space to the flat Bragg crystal. The matched system has a desirable feature that the phase space of the bent crystal’s output beam is much larger than that of the flat crystal, making the combined system stable. Based on these considerations, here we present our optical design for performing DEI/ABI at the HEX beamline

36 MATERIALS SCIENCE↗

Metalloproteins in an Era of Modern Crystallography and Why the Beamline Matters

The Structural Molecular Biology (SMB) macromolecular crystallography (MC) group at the Stanford Synchrotron Radiation Lightsource (SSRL) have developed state-of-the-art capabilities tailored for metalloenzyme structural analysis. Metalloproteins sit at the center of biology’s most audacious chemistry. From multi-electron redox catalysis to radical rearrangements and light-driven transformations, metal sites give proteins access to reaction landscapes that would otherwise be inaccessible under ambient conditions. Yet their study presents a fundamental paradox for MC studies: the very X-rays we use to reveal atomic structure can alter the electronic states we seek to understand. As the field moves beyond static snapshots toward mechanistic insight, success increasingly depends on our ability to maintain metal centers in their native state throughout the experiment. The SSRL SMB-MC beamlines integrate a suite of capabilities specifically designed to address these challenges. By combining in situ spectroscopic verification, intelligent dose management, controlled reaction initiation, optimized anomalous diffraction, and real-time crystallographic diffraction analysis, these tools enable researchers to interrogate metalloproteins with unprecedented rigor. This article explores how these complementary approaches are reshaping our ability to capture metalloprotein chemistry, and what this means for mechanistic studies at synchrotron beamlines.

Maggiolo, Ailiena O. [SLAC National Accelerator La↗

Beamline K11 DIAD: a new instrument for dual imaging and diffraction at Diamond Light Source

The Dual Imaging and Diffraction (DIAD) beamline at Diamond Light Source is a new dual-beam instrument for full-field imaging/tomography and powder diffraction. This instrument provides the user community with the capability to dynamically image 2D and 3D complex structures and perform phase identification and/or strain mapping using micro-diffraction. The aim is to enable in situ and in operando experiments that require spatially correlated results from both techniques, by providing measurements from the same specimen location quasi-simultaneously. Using an unusual optical layout, DIAD has two independent beams originating from one source that operate in the medium energy range (7–38 keV) and are combined at one sample position. Here, either radiography or tomography can be performed using monochromatic or pink beam, with a 1.4 mm × 1.2 mm field of view and a feature resolution of 1.2 µm. Micro-diffraction is possible with a variable beam size between 13 µm × 4 µm and 50 µm × 50 µm. One key functionality of the beamline is image-guided diffraction, a setup in which the micro-diffraction beam can be scanned over the complete area of the imaging field-of-view. This moving beam setup enables the collection of location-specific information about the phase composition and/or strains at any given position within the image/tomography field of view. The dual beam design allows fast switching between imaging and diffraction mode without the need of complicated and time-consuming mode switches. Real-time selection of areas of interest for diffraction measurements as well as the simultaneous collection of both imaging and diffraction data of (irreversible) in situ and in operando experiments are possible.

36 MATERIALS SCIENCE↗

Strong-field QED experiments using the BELLA PW laser dual beamlines

The petawatt (PW) laser facility of the Berkeley Lab Laser Accelerator (BELLA) Center has recently commissioned its second laser pulse transport line. This new beamline can be operated in parallel with the first beamline and enables strong-field quantum electrodynamics (SF-QED) experiments at BELLA. In this paper, we present an overview of the upgraded BELLA PW facility with a SF-QED experimental layout in which intense laser pulses collide with GeV-class laser-wakefield-accelerated electron beams. We present simulation results showing that experiments will allow the study of laser-particle interactions from the classical to the SF-QED regime with a nonlinear quantum parameter of up to χ ~2. Additionally, we show that experiments will enable the study and production of GeV-class, mrad-divergence positron beams via the Breit–Wheeler process. Graphical abstract: [Figure not available: see fulltext.].

43 PARTICLE ACCELERATORS↗

SINGLE BUNCH TRACKING ON THE TEN-PASS ER@CEBAF ENERGY RECOVERY BEAMLINE

The proposed ten-pass energy recovery linac (ERL) demonstration (five accelerating, five decelerating) at the CEBAF accelerator, ER@CEBAF, involves a multi-GeV en- ergy range of a continuous electron beam. New CEBAF transverse optics were designed for this ERL demonstration. This redesign incorporates additional components in Arc A, including a path length chicane and new quadrupoles to ensure proper dispersion localization. The new five energy recovery passes with a shared arc transport scheme chal- lenge the overall beamline optics design, including large beta functions in the CEBAF spreaders and recombiners. Here we discuss results of bunch tracking performed using the elegant tracking code for the full ER@CEBAF beamline

Neththikumara, I.↗

SRF Resonators for a bi-directional Energy Ramping Upgrade of the Isotope Production Facility Beamline at LANL

The LANL Isotope Production Facility (IPF) is one of the two high-current proton linear accelerators operated under the auspices of the DOE Office of Nuclear Physics Isotope Development and Production for Research Applications Program. The IPF beamline operates with a fixed 100-MeV energy proton beam, diverted from the LANSCE accelerator and guided towards the isotope production target station. The fixed beam energy limits the number of isotopes that can be produced at IPF, and adversely affects the purity of isotopes produced at non-optimal energies. In particular, the IPF program is receiving increasing numbers of requests for high purity isotopes such as Np-236 (national security applications) and Re-186 (medical therapy). These are typically produced via (p,n) and (p,2n) nuclear reactions, requiring very tight control of the incident energies on the production targets to ensure an end product with a high radionuclidic purity. It is well known that this level of energy control cannot be achieved when a 100 MeV beam of mono-energetic protons is degraded to the required energies, typically below 30 MeV, as too much energy spread is acquired. Operating the IPF beamline at lower, mono-energetic beam energies such as at 40 MeV will allow the required tight energy control in target assemblies to ensure a high purity product. In addition, NP has requested a LANL/BNL/ORNL collaboration focus on establishing a national large-scale production capability for the therapy isotope Ac-225. Recent nuclear cross section measurements done at LANL show that due to a steep rise in production cross section towards higher proton energies (See Figure 2), proton beams at energies substantially greater than 100 MeV will be highly beneficial for Ac-225 production [AC255]. Such higher-energy beams cannot be delivered to IPF at present. Lower-energy beams (70 MeV and 40 MeV) can be delivered but only in sole-use mode; all other LANSCE users must be offline during 70 MeV or 40 MeV operation.

07 ISOTOPE AND RADIATION SOURCES↗

Expanded Capabilities and Opportunities for Virtual Beamline Code

In the 25 years since LLNL broke ground on the National Ignition Facility (NIF) - a cornerstone of the National Nuclear Security Administration’s Stockpile Stewardship Program - the NIF and Photon Science (NIF&PS) Directorate has steadily pushed the boundaries of laser physics, nonlinear optics, and photonics in service of inertial confinement fusion experiments, and advanced photon sources development. Beyond the 192 beamlines of the primary laser facility with its world-record energy and fusion yields, NIF&PS capabilities have expanded to include chirped-pulse amplification, kilojoule petawatt-class short-pulse systems to generate hard x-ray radiographic probes, high-average power lasers as secondary sources for generation or wake field particle acceleration along directed energy applications, and other scientific pursuits. The Computing Directorate partners with NIF&PS on numerous projects and technologies from diagnostic measurements and high performance control systems to data analysis, information technology infrastructure, and scientific simulation code development. “This strong collaboration enables cutting-edge science, particularly with regard to physics-based modeling and simulation,” says physicist Jean-Michel Di Nicola. One crucial capability for NIF&PS is the Virtual Beamline (VBL) laser simulation code. It can model all the major laser physics and technology involved in the design optimization, commissioning, and operations of advanced laser architectures from tabletop to NIF-scale. VBL provides researchers with high-fidelity models and high-resolution calculations of laser performance predictions—including for the entire NIF laser system, the Advanced Radiographic Capability, parts of the High Repetition-Rate Advanced Petawatt Laser System laser delivered to the Czech Republic, and the Optical Science Laser. After more than two decades of experimentally verified physics and computing enhancements, this unique workhorse code is wrapping up another major milestone: migration from Java to C++ with a flurry of user interface and optimization features, as well as laser physics and high-resolution enhancements thanks to parallel execution on Livermore Computing platforms.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

MTA Secondary Beamline Production and Optics Optimization

A new secondary beamline was recently installed in the MeV Test Area (MTA) with the objective of enhancing mu+/mu- production by factors of 3/8 by using a tungsten target versus the conventional graphite production target using the 400 MeV Fermilab proton Linac beam. Ultra-low energy muon beams can support world-class physics experiments for fundamental muon measurements, sensitive searches for symmetry violation, and precision tests of theory. Extensive production studies have confirmed higher muon yield from heavy targets (tungsten vs carbon), but also, surprisingly, showed significant differences in production fluence and energy spectrum between modern hadronic models (GENIEhad) and between GEANT and MCNP. Studies are also underway towards a high-efficiency source of muonium by stopping the mu+ beam in superfluid helium. Muon fluxes can be measured at MTA including using higher-Z and novel target geometries to test hadronic and production models which are critical to understanding ongoing experiments (Mu2e) and will significantly impact the planning of future HEP experiments and planning PIP II facilities. The MTA beamline will additionally support a broad user muon test beam for future experiments and R&D.

Ahmed, Shiza↗

Modeling of the Jupiter Lase Facility Using Virtual Beamline ++ (Vbl++) Code

The Jupiter Laser Facility (JLF) at Lawrence Livermore National Laboratory (LLNL) is a mid-scale laser facility, with three different laser platforms: Janus (Target Area 1), Titan, and COMET. To help the facility and its users better understand the laser performance, a model of Janus and Titan has been developed using the Virtual Beamline ++ code (VBL++), which was initially developed by LLNL to model the National Ignition Facility beamlines and predict their performance.

43 PARTICLE ACCELERATORS↗

On Possibilities of Using Edge Radiation for X-ray and Electron Beam Diagnostics at Bending Magnet Beamlines of NSLS-II

Spectral flux density distributions of long-wavelength Edge Radiation, i.e. radiation generated by relativistic electrons at edges of bending magnets in a storage ring are described, both analytically and numerically. Possibilities of using this radiation for the alignment of optical components of bending magnet beamlines at NSLS-II and for non-destructive X-ray and electron beam diagnostics at these beamlines are discussed.

43 PARTICLE ACCELERATORS↗

Antiproton background of the Mu2e experiment and the vertical misalignment of the Mu2e beamline

Mu2e experiment will search for the neutrinoless µ − → e − conversion in the field of an aluminum nucleus. The total expected background in Mu2e Run I is 0.11 ± 0.03 events, and the antiproton background, 0.01 ± 0.003(stat) ± 0.010(syst), is about 10% of the total. The report discusses the antiproton background of the Mu2e experiment. As it will be explained, the antiproton background is sensitive to the vertical misalignment of the Mu2e beamline. Therefore, it is important to measure the misalignment in situ. The report introduces a data-driven technique of measuring the beamline misalignment. The material is organized as follows. Section 2 describes the Mu2e experiment. Section 3 presents the antiproton background. Section 4 explains the alignment in the apparatus. Section 5 presents the vertical misalignment and a method to measure it from the data. Section 6 presents the initial simulations made and the discussion of the results.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Dose Measurement and Monte Carlo FLUKA simulations for the FE and FOE of the 27-ID HEX Beamline

The 27-ID High Energy Engineering X-ray Scattering (HEX) beamline, commissioned in 2024, operates within the Hard X-ray Scattering and Spectroscopy program at Brookhaven Lab’s National Synchrotron Light Source II (NSLS-II). The high energy spectrum at the HEX beamline extends up to several hundred keV, making it well suited for applications such as imaging large engineering samples, including fully assembled batteries, fuel cells, etc.

43 PARTICLE ACCELERATORS↗