Bending Tests on Box Beams Having Solid- and Open-construction Webs
Explore the source record for details and available documents.
SEARCH · Search NASA
Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.
Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.
Explore the source record for details and available documents.
Explore the source record for details and available documents.
It was originally proposed to investigate the effect of microalloying on the ductility of monocrystalline NiAl. The idea was to deposit selected elements on oriented crystals of NiAl using magnetron sputtering, followed by annealing at high temperatures to produce the doped specimens. The project was terminated before that stage of the research was reached, but useful results needed for that study were obtained during the lifetime of the program. Those results are described in this report.
It was originally proposed to investigate the effect of microalloying on the ductility of monocrystalline NiAl. The idea was to deposit selected elements on oriented crystals of NiAl using magnetron sputtering, followed by annealing at high temperatures to produce the doped specimens. The project was terminated before that stage of the research was reached, but useful results needed for that study were obtained during the lifetime of the program. Those results are described in this resort.
Space Shuttle Discovery's last mission, STS-133, was scheduled to launch on November 5, 2010. Just hours before liftoff, a hydrogen leak at an umbilical connection scrubbed the launch attempt. After the scrub, further inspection revealed a large crack in the foam insulation covering the External Tank, ET-137. Video replay of the launch attempt confirmed the crack first appeared as cryogenic propellants were being loaded into the ET. When the cracked foam was removed, technicians found the underlying stringer had two 9-inch-long cracks. Further inspection revealed a total of 5 of the 108 ET stringers had cracked. NASA and Lockheed Martin immediately launched an aggressive campaign to understand the cracks and repair the stringers in ET-137, targeting February 2011 as the new launch date for STS-133. Responsibilities for the various aspects of the investigation were widely distributed among NASA centers and organizations. This paper will focus on lab testing at Marshall Space Flight Center (MSFC) in Huntsville, Alabama that was intended to replicate the stringer failure and gauge the effect of proposed countermeasures.
Explore the source record for details and available documents.
Recent modeling of filament-wound composite structures drove the need for a new element type within the finite element code DYNA3D/Paradyn. This new layered solid element was implemented and designed to capture the kinematics and constitutive be havior of various lamina layers defined with arbitrary orientations and volume fractions within the element to accurately model a laminated composite material. The new el ement uses a single integration point in each of the lamina layers defined to capture the constitutive behavior, and a novel physical stabilization routine is used to prevent hourglassing while mitigating shear and volumetric locking. This report documents the verification testing and the regression tests added to the DYNA3D/Paradyn software quality assurance test suite to assess the proper implementation of the new layered solid element. There were a total of 27 tests added the DYNA3D test suite, which consist of problems using the layered solid element with a single layer or multiple layers for isotropic and orthotropic material models. These tests are a combination of simple kinematically driven patch tests, beam bending tests, plate bending tests, and more complicated problems. Ultimately, the testing done verifies that the element behaves as expected and is implemented correctly.
Here, fully-reversed cyclic bending tests were conducted on uncoated and Cr-coated 316 stainless steel specimens. At high stresses, the uncoated specimens outperformed the Cr-coated ones, while the trend reversed at low stresses. For Cr-coated specimens subjected to high stress amplitude loading, experimental observations showed crack initiation at the Cr/substrate interface due to shear steps formed from dislocation activities in the substrate—a conclusion supported by accompanying finite element analysis. Interfacial crack initiation was not observed under low stress amplitudes. This difference in fatigue crack initiation mechanisms induced an opposite trend in fatigue life between high and low stress amplitudes.
The Mixed Mode Bending (MMB) test uses a lever to simultaneously apply mode I and mode II loading to a split beam specimen. An iterative analysis that accounts for the geometric nonlinearity of the MMB test was developed. The analysis accurately predicted the measured load displacement response and the strain energy release rate, G, of an MMB test specimen made of APC2 (AS4/PEEK). The errors in G when calculated using linear theory were found to be as large as thirty percent in some cases. Because it would be inconvenient to use a nonlinear analysis to analyze MMB data, the MMB apparatus was redesigned to minimize the nonlinearity. The nonlinear analysis was used as a guide in redesigning the MMB apparatus. With the redesigned apparatus, loads were applied through a roller attached to the level and loaded just above the midplane of the test specimen. The redesigned apparatuus has geometric nonlinearity errors of less than three percent, even for materials substantially tougher than APC2. This apparatus was demonstrated by measuring the mixed mode delamination fracture toughness of APC2.
Gears in vertical lift applications will typically experience greater than 107bending fatigue cycles over their design lifetime. Currently, fatigue life prediction of gears exceeding 107cycles are based on empirical correlations, since collection of fatigue data beyond 107 cycles is impractical with traditional fatigue testing methods. Ultrasonic fatigue testing enables fatigue testing in excess of 109cycles in as few as 14 hours. In this paper, a novel specimen design for ultrasonic fatigue testing to accurately represent the geometry, stress profile, and residual stress of gear teeth in reversible bending fatigue is presented. The specimen design is discussed in detail, testing is performed to validate operating principles, and an initial fatigue data set of 8 specimens is presented.
Gears in vertical lift applications will typically experience greater than 107bending fatigue cycles over their design lifetime. Currently, fatigue life prediction of gears exceeding 107cycles are based on empirical correlations, since collection of fatigue data beyond 107 cycles is impractical with traditional fatigue testing methods. Ultrasonic fatigue testing enables fatigue testing in excess of 109cycles in as few as 14 hours. In this paper, a novel specimen design for ultrasonic fatigue testing to accurately represent the geometry, stress profile, and residual stress of gear teeth in reversible bending fatigue is presented. The specimen design is discussed in detail, testing is performed to validate operating principles, and an initial fatigue data set of 8 specimens is presented.
Low Earth orbit space environment conditions, including ultraviolet radiation, thermal cycling, and atomic oxygen exposure, can cause degradation of exterior spacecraft materials over time. Radiation and thermal exposure often results in bond- breaking and embrittlement of polymers, reducing mechanical strength and structural integrity. An experiment called the Flexural Stress Effects Experiment (FSEE) was flown with the objective of determining the role of space environmental exposure on the degradation of polymers under flexural stress. The FSEE samples were flown in the wake orientation on the exterior of International Space Station for 1.5 years. Twenty-four samples were flown: 12 bent over a 0.375 in. mandrel and 12 were over a 0.25 in. mandrel. This was designed to simulate flight configurations of insulation blankets on spacecraft. The samples consisted of assorted polyimide and fluorinated polymers with various coatings. Half the samples were designated for bend testing and the other half will be tensile tested. A non-standard bend-test procedure was designed to determine the surface strain at which embrittled polymers crack. All ten samples designated for bend testing have been tested. None of the control samples' polymers cracked, even under surface strains up to 19.7%, although one coating cracked. Of the ten flight samples tested, seven show increased embrittlement through bend-test induced cracking at surface strains from 0.70%to 11.73%. These results show that most of the tested polymers are embrittled due to space exposure, when compared to their control samples. Determination of the extent of space induced embrittlement of polymers is important for designing durable spacecraft.
This report is the fifth of a series presenting the results of strength tests of thin-walled cylinders and truncated cones of circular and elliptic section; it includes the results obtained from torsion tests on 30 cylinders, pure bending tests on 30 cylinders, and combined transverse shear and bending tests on 60 cylinders. All the cylinders tested were elliptic section with the ends clamped to rigid bulkheads. In the pure bending and combined transverse shear and bending tests the loads were applied in the plane of the major axis. The results of the tests on elliptic cylinders are correlated with the results of corresponding tests on circular cylinders and are presented in charts suitable for use in design.
The results of a series of tests of graphite-polyimide honeycomb sandwich panels are presented. The panels were 1.22 m long, 0.508 m wide, and approximately 13.3 m thick. The face sheets were a T-300/PMR-15 fabric in a quasi-isotropic layup and were 0.279 mm thick. The core was Hexcel HRH 327-3/16 - 4.0 glass reinforced polyimide honeycomb, 12.7 mm thick. Three panels were used in the test: one was cut into smaller pieces for testing as beam, compression, and shear specimens; a second panel was used for plate bending tests; the third panel was used for in-plane stability tests. Presented are the experimental results of four point bending tests, short block compression tests, core transverse shear modulus, three point bending tests, vibration tests, plate bending tests, and panel stability tests. The results of the first three tests are used to predict the results of some of the other tests. The predictions and experimental results are compared, and the agreement is quite good.
The shear stress fringe value of orthotropic birefringent model materials is presently used in an asymmetric four-point bend test that employs a notched specimen and is a modification of the Iosipescu test (1967). While in the case of a unidirectionally reinforced glass-polyester model material, shear stress fringe values obtained from 90- and 120-deg (sharp and radiused) notches are reasonably close to the values obtained for an off-axis tensile specimen, no conclusions can be drawn on the influence of the notch parameters, due to the peculiarities of the photoelastic response of the inhomogeneous orthotropic model material. The failure modes nevertheless indicate that a notch radius, and the 120-deg notch angle, reduce the stress concentration. Comparisons are made with finite element results.
Reversed bending fatigue tests on stainless steel fibermetal with porous structure to investigate effects of density, thickness, wire diameter, screen stiffening, etc
Data Processing Package for Cyclic Integrated Reversible Bending Fatigue Testing
The mixed-mode bending (MMB) test uses a lever to apply simultaneously mode I and mode II loading to a split-beam specimen. An iterative analysis that accounts for the geometric nonlinearity of the MMB test was developed. The analysis accurately predicted the measured load-displacement response and the strain energy release rate, G, of an MMB test specimen made of AS4/PEEK. The errors in G when calculated using linear theory were found to be as large as 30 percent in some cases. Because it would be inconvenient to use a nonlinear analysis to analyze MMB data, the MMB apparatus was redesigned to minimize the nonlinearity. With the improved apparatus, loads are applied just above the midplane of the test specimen through a roller attached to the lever. This apparatus was demonstrated by measuring the mixed-mode delamination fracture toughhess of the test specimen. The nonlinearity errors associated with testing this tough composite material were less than +/- 3 percent. The data from the improved MMB apparatus analyzed with a linear analysis were similar to those found with the original apparatus and the nonlinear analysis.