Search NASA⌕ Search

SEARCH · Search NASA

Results for “Blackbody”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 55 records · Page 3

Enhanced power density in zero-vacuum-gap thermophotovoltaic devices

Thermophotovoltaic (TPV) devices, which convert infrared thermal radiation from a hot emitter into electricity, hold great promise for applications in energy storage and waste heat recovery. While recent advancements have developed TPV devices with high efficiency, much less attention has been focused on improving the power density. Current TPV methods face challenges in significantly boosting the power density using emitters at very high temperatures (>2000 °C) or using complex, costly architectures such as near-field TPV. Here, we present the first experimental demonstration of a novel far-field TPV concept called “zero-vacuum-gap TPV” that eliminates the vacuum or gas-filled gap in conventional designs. By incorporating a high-index, infrared-transparent, and thermally insulating fused quartz spacer, we achieved a two-fold increase in power density compared to the far-field counterpart under identical conditions. Notably, in our experiment, the zero-vacuum-gap far-field design transforms a less-optimized, low-power-density far-field device into one with one of the highest power densities reported at moderate temperatures (700–1100 °C). Moreover, our measurements using a graphite emitter surpass the blackbody limit for gap-integrated far-field devices and match the performance of near-field TPV devices with an ultrathin 200-nm gap. Our findings suggest that zero-vacuum-gap TPV offers potential for cost-effective, scalable manufacturing using current technologies. Additionally, our modelling predicts that further power enhancements over one order of magnitude are possible with other spacer materials.

14 SOLAR ENERGY↗

Planck intermediate results

In this work, we describe an extension of the most recent version of the Planck Catalogue of Compact Sources (PCCS2), produced using a new multi-band Bayesian Extraction and Estimation Package (BeeP). BeeP assumes that the compact sources present in PCCS2 at 857 GHz have a dust-like spectral energy distribution (SED), which leads to emission at both lower and higher frequencies, and adjusts the parameters of the source and its SED to fit the emission observed in Planck’s three highest frequency channels at 353, 545, and 857 GHz, as well as the IRIS map at 3000 GHz. In order to reduce confusion regarding diffuse cirrus emission, BeeP’s data model includes a description of the background emission surrounding each source, and it adjusts the confidence in the source parameter extraction based on the statistical properties of the spatial distribution of the background emission. BeeP produces the following three new sets of parameters for each source: (a) fits to a modified blackbody (MBB) thermal emission model of the source; (b) SED-independent source flux densities at each frequency considered; and (c) fits to an MBB model of the background in which the source is embedded. BeeP also calculates, for each source, a reliability parameter, which takes into account confusion due to the surrounding cirrus. This parameter can be used to extract sub-samples of high-frequency sources with statistically well-understood properties. We define a high-reliability subset (BeeP/base), containing 26 083 sources (54.1% of the total PCCS2 catalogue), the majority of which have no information on reliability in the PCCS2. We describe the characteristics of this specific high-quality subset of PCCS2 and its validation against other data sets, specifically for: the sub-sample of PCCS2 located in low-cirrus areas; the Planck Catalogue of Galactic Cold Clumps; the Herschel GAMA15-field catalogue; and the temperature- and spectral-index-reconstructed dust maps obtained with Planck’s Generalized Needlet Internal Linear Combination method. The results of the BeeP extension of PCCS2, which are made publicly available via the Planck Legacy Archive, will enable the study of the thermal properties of well-defined samples of compact Galactic and extragalactic dusty sources.

79 ASTRONOMY AND ASTROPHYSICS↗

XMM-Newton and TESS observations of the highly variable polar V496 UMa

We studied the temporal and spectral behavior of V496 UMa from the optical to the X-ray regimes. Methods. We used archival XMM-Newton and TESS observations obtained in 2017 and 2019, respectively, to perform a spectral and timing analysis of the highly variable magnetic CV. Results. The light curves of the TESS and XMM-Newton satellites reveal a double-humped pattern modulated with the periodicity of 91.058467 ± 0.00001 min. V496 UMa displays a two-pole accretion geometry in the high accretion state. X-ray spectra from these regions are composed of thermal plasma radiation and soft blackbody components with almost identical temperatures and a total accretion rate of $\dot{M}$ = 1.4(8) × 10 -11 M ⊙ yr -1 . The X-ray centers of the humps show longitudinal shifts of -18° and 4°, and shifts around photometric phase zero of -172° and -186°, for the main hump and second hump, respectively. The long-term ZTF light curves reveal high and low accretions states. Low-state ZTF and SDSS photometric data are consistent with an 0.8 M ⊙ white dwarf at 10 000 K and a main-sequence donor star with a spectral type of M5.0 at a Gaia determined distance of 758 pc. Conclusions. V496 UMa is a very bright polar in X-rays when it is in the high state. Due to its unusual geometric structure, mass accretion onto the second accretion pole is interrupted occasionally. This discontinuous behavior does not follow a certain pattern in time and has been observed so far only in the high state. The X-ray light curves display clear evidence of an accretion stream at the photometric phase of φ = 0.81, which does not show up in optical light curves. An accurate period was derived using the combined TESS and XMM-Newton data, which differs by 3.8 σ from published results.

79 ASTRONOMY AND ASTROPHYSICS↗

BEYONDPLANCK XIV. Polarized foreground emission between 30 and 70 GHz

We constrain polarized foreground emission between 30 and 70 GHz with the Planck Low Frequency Instrument (LFI) and WMAP data within the global Bayesian BeyondPlanck framework. We combine for the first time full-resolution Planck LFI time-ordered data with low-resolution WMAP sky maps at 33, 40 and 61 GHz. Spectral parameters are fit with a likelihood defined at the native resolution of each frequency channel. This analysis represents the first implementation of true multi-resolution component separation applied to CMB observations for both amplitude and spectral energy distribution (SED) parameters. For synchrotron emission, we approximate the SED as a power-law in frequency and find that the low signal-to-noise ratio of the current data strongly limits the number of free parameters that may be robustly constrained. We partition the sky into four large disjoint regions (High Latitude; Galactic Spur; Galactic Plane; and Galactic Center), each associated with its own power-law index. We find that the High Latitude region is prior-dominated, while the Galactic Center region is contaminated by residual instrumental systematics. The two remaining regions appear to be signal-dominated, and for these we derive spectral indices of $β$ S Spur = -3.17 ± 0.06 and $β$ S Plane = -3.03 ± 0.07, in good agreement with previous results. For thermal dust emission we assume a modified blackbody model and we fit a single power-law index across the full sky. We find $β$ d = 1.64 ± 0.03, which is slightly steeper than reported from Planck HFI data, but still statistically consistent at the 2σ confidence level.

79 ASTRONOMY AND ASTROPHYSICS↗

Streaked optical pyrometer for proton-driven isochoric heating experiments of solid and foam targets

We have designed, built, and calibrated an ultrafast streaked optical pyrometer (SOP) with ~5 ps resolution for measuring the time-resolved surface blackbody temperature of an isochorically heated plasma. The pyrometer is calibrated to measure temperatures from 0.5 eV to 25 eV, with the option of adding calibrated neutral density filters to observe hotter plasmas. We demonstrated the use of this pyrometer on isochoric heating experiments using laser-accelerated proton beams as an energy source at the $f$ /40 beamline of the Texas Petawatt Laser. We used the large focal spot size (~80 μm radius) of the $f$ /40 pulses to accelerate high numbers of ~MeV protons off 5 μm thick solid gold targets. During our experimental campaign, we heated 10 μm thick aluminum foil targets to 1–10 eV over a duration of 50 ps and also observed heating to ~2 eV in 100 μm thick 60 mg/cm 3 carbon foams using the SOP to measure both the temperature and heating timescale.

Equations of state↗

Method for conducting in situ high-temperature digital image correlation with simultaneous synchrotron measurements under thermomechanical conditions

This work presents a novel method of obtaining in situ strain measurements at high temperature by simultaneous digital image correlation (DIC), which provides the total strain on the specimen surface, and synchrotron x-ray diffraction (XRD), which provides lattice strains of crystalline materials. DIC at high temperature requires specialized techniques to overcome the effects of increased blackbody radiation that would otherwise overexpose the images. The technique presented herein is unique in that it can be used with a sample enclosed in an infrared heater, remotely and simultaneously with synchrotron XRD measurements. The heater included a window for camera access, and the light of the heater lamps is used as illumination. High-temperature paint is used to apply a random speckle pattern to the sample to allow the tracking of displacements and the calculation of the DIC strains. An inexpensive blue theatrical gel filter is used to block interfering visible and infrared light at high temperatures. This technique successfully produces properly exposed images at 870 °C and is expected to perform similarly at higher temperatures. The average strains measured by DIC were validated by an analytical calculation of the theoretical strain. Simultaneous DIC and XRD strain measurements of Inconel 718 (IN718) tensile test specimens were performed under thermal and mechanical loads and evaluated. Finally, this approach uses the fact that with DIC, the total strain is measured, including plastic strain, while with XRD, only elastic strain is captured. The observed differences were discussed with respect to the effective deformation mechanisms.

47 OTHER INSTRUMENTATION↗

Soft x-ray spectrum unfold of K-edge filtered x-ray diode arrays using cubic splines

Cubic spline interpolation is able to recover temporally and spectrally resolved soft x-ray flux from an array of K-edge filtered x-ray diodes without the need for a priori assumptions about the spectrum or the geometry of the emitting volume. The mathematics of the cubic spline interpolation is discussed in detail. The analytic nature of the cubic spline solution allows for analytical error propagation, and the method of calculating the error for radiation temperature, spectral power, and confidence intervals of the unfolded spectrally resolved flux is explained. An unfold of a blackbody model demonstrates the accuracy of the cubic spline unfold. Tests of cubic spline performance using spectrally convolved detailed atomic model simulation results have been performed to measure the method's ability to conserve spectral power to within a factor of 2 or better in line-dominated regimes. The unfold is also demonstrated to work when information from the x-ray diode array is limited due to high signal-to-noise ratios or lack of signal due to over-attenuation or over-filtration of the x-ray diode signal. Here, the robustness of the unfold with respect to background subtraction and raw signal processing, signal alignment between diode traces, limited signal information, and initial conditions is discussed. Results from an example analysis of a halfraum drive are presented to demonstrate the capabilities of the unfold in comparison with previously established methods.

47 OTHER INSTRUMENTATION↗

A genetic algorithm approach for reconstructing spectral content from filtered x-ray diode array spectrometers

Filtered diode array spectrometers are routinely employed to infer the temporal evolution of spectral power from x-ray sources, but uniquely extracting spectral content from a finite set of broad, spectrally overlapping channel spectral sensitivities is decidedly nontrivial in these under-determined systems. Here, we present the use of genetic algorithms to reconstruct a probabilistic spectral intensity distribution and compare to the traditional approach most commonly found in the literature. Unlike many of the previously published models, spectral reconstructions from this approach are neither limited by basis functional forms nor do they require a priori spectral knowledge. While the original intent of such measurements was to diagnose the temporal evolution of spectral power from quasi-blackbody radiation sources—where the exact details of spectral content were not thought to be crucial—we demonstrate that this new technique can greatly enhance the utility of the diagnostic by providing more physical spectra and improved robustness to hardware configuration for even strongly non-Planckian distributions.

47 OTHER INSTRUMENTATION↗

Transient magnetic field diffusion considerations relevant to magnetically assisted indirect drive inertial confinement fusion

We report application of a magnetic field to an indirect drive inertial confinement fusion target requires diffusion of the field through the high-Z and electrically conducting Hohlraum. The onset of the external field generates eddy currents in the Hohlraum wall that result in (1) a reduction of the peak field at the capsule, (2) heating of the Hohlraum wall through Ohmic dissipation, and (3) wall movement due to the inward force from the eddy current interacting with the field. Heating of the wall causes an increase in blackbody radiation which can preheat the capsule and frozen deuterium–tritium fuel, while wall motion leads to potential misalignment of the lasers at the Hohlraum wall. Limiting these detrimental effects sets requirements on the tolerable magnitude of each effect. We present a nonlinear model for B-field diffusion through an infinitely long thin-walled cylinder with a temperature dependent resistivity, to show that a 15 μm thick wall of pure gold fails to meet these requirements. A new Hohlraum material made from an alloy of Au and Ta has a measured resistivity of ≥60 times that of Au and is shown with the nonlinear model to meet the requirements for magnetization. We compare the nonlinear model to simulations of the actual Hohlraum target using a finite element code which includes temperature-dependent Hohlraum resistivity.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

High speed ultraviolet digital image correlation (UV-DIC) for dynamic strains at extreme temperatures

Digital Image Correlation (DIC) is a camera-based method of measuring full-field displacements and strains from the surface of a deforming object. It can be applied at any length scale (determined by the lenses) and any time scale (determined by the camera), and because it is non-contacting, it can also be used at temperatures much higher than can be withstood by bonded strain gauges. At extreme temperatures, materials emit light in the form of blackbody radiation, which can saturate the camera sensor. It has previously been shown that the emitted light can be effectively screened by using ultraviolet (UV) cameras, lenses, and filters; however, commercially available UV cameras are relatively slow, which limits the speed of combined UV-DIC measurements. In this study, a UV intensifier was paired with a high-speed camera, and its ability to perform UV-DIC at high temperature and high speed was investigated. The system was compared over three different experiments: (A) a quasi-static thermal expansion test at high temperature, (B) a vibration test at room temperature, and (C) the same vibration test repeated at high temperature. The system successfully performed DIC up to at least 1600 °C at frame rates of 5000 fps, which is more than 100 times faster than other examples of UV-DIC in the literature. In all cases, measurements made using the UV intensifier were much noisier than those made without the intensifier, but the intensifier enabled measurements at temperatures well above those which an unfiltered high-speed camera otherwise saturates.

47 OTHER INSTRUMENTATION↗

Traceability of Surface Longwave Irradiance Measurements to SI Using the IRIS Radiometers

The traceability of the World Infrared Standard Group of Pyrgeometers (WISG) was established through the comparison to several independently calibrated radiometers (Infrared Integrating Sphere Radiometer (IRIS), Absolute Cavity Pyrgeometer (ACP), Atmospheric Emittance Radiance Interferometer (AERI)). The traceability of the longwave irradiance measurements to SI was validated by a comparison of two independently characterized blackbody cavities.

ACR↗

Developing a robust sensor for infrared imaging bolometers

A new type of large area sensor for infrared imaging bolometers has been developed. It replaces the thin and fragile free-standing metal foils, which typically have been used, with a multi-layer coated sapphire (or diamond) substrate. Sapphire is transparent to mid-infrared wavelengths, is robust against transients, and can be thick enough to even be the vacuum window. The primary radiation absorber is still a thin deposited metal layer, but now it is partially insulated from the supporting sapphire substrate by a black (carbon-based) layer, which also acts as a blackbody remitter. Test results indicate 6× more noise equivalent power density (estimated NEPD = 23 W/m 2 at 5 ms camera exposure time, foil temperature decay time 60 ms) for a 2 μm gold-coated sapphire disk compared to estimated NEP = 4 W/m 2 at 1.8 ms exposure time, with foil decay time 420 ms, for a nominal 2.5 μm thick platinum-free-standing foil.

47 OTHER INSTRUMENTATION↗

Electron tail suppression and effective collisionality due to synchrotron emission and absorption in mildly relativistic plasmas

Synchrotron radiation losses are a significant cause of concern for high-temperature aneutronic fusion reactions such as proton–Boron 11. The fact that radiation losses occur primarily in the high-energy tail, where the radiation itself has a substantial impact on the electron distribution, necessitates a self-consistent approach to modeling the diffusion and drag induced by synchrotron absorption and emission. Furthermore, an accurate model must account for the fact that the radiation emission spectrum is momentum-dependent, and the plasma opacity is frequency-dependent. Here, we present a simple Fokker–Planck operator, built on a newly solved-for blackbody synchrotron diffusion operator, which captures all relevant features of the synchrotron radiation. Focusing on magnetic mirror fusion plasmas, we show that significant suppression of the electron distribution occurs for relativistic values of the perpendicular electron momentum, which therefore emit much less radiation than predicted under the assumption of a Maxwell–Jüttner distribution.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Fusion burn-propagation simulations using the collisional and radiative particle-in-cell code TRIFORCE

The ability to accurately model burn propagation in inertial confinement fusion plasmas is crucial for advancing fusion energy research. This work presents enhancements to the triforce hybrid fluid-kinetic multiphysics code, focusing on its kinetic half, which employs the particle-in-cell (PIC) method with Monte Carlo collisions (MCC). We use a moment-preserving collision model that mitigates numerical noise, particularly in spherical geometries where particle weights vary significantly. Additionally, we refine the treatment of inverse bremsstrahlung to account for electron–ion collision frequency reductions in degenerate plasmas and incorporate a blackbody radiation source to enable realistic photon injection. These improvements enable the simulation of 1-dimensional (1D) spherical fusion burn propagation in deuterium–tritium plasmas. Benchmark comparisons with the hydra radiation-hydrodynamics code confirm that triforce accurately captures the dynamics of hot-spot expansion and burn propagation, demonstrating sensitivity to ignition thresholds consistent with theoretical models. Findings show the ignition cliff to be less steep in our work compared to radiation-hydrodynamic modeling. These results highlight the role of kinetic effects in fusion ignition physics and underscore the necessity of hybrid fluid-kinetic models for advancing predictive capabilities in high-energy-density plasma systems.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Intense cavitation-assisted electric discharge as a promising tool for water treatment

This study investigates interrelations between one-electrode Cavitation-Assisted Electric Discharge (CAED), two-electrode CAED, and recently discovered Intense CAED (I-CAED). The one-electrode CAED is a self-triggered nanosecond discharge with pulse energy in the micro-Joule range, which can be generated even by a DC voltage. I-CAED consists of a non-equilibrium part within a low-pressure cavitating region and a micro-spark traversing a liquid film. We hypothesize that CAED propagates from the high-voltage electrode as an ionization wave through bubbles of saturated vapor. Subsequently, the streamer-like discharges in the bubbles may form a continuous plasma channel. Inside the cavitating region, the plasma is strongly non-equilibrium, providing an ideal environment for generating chemically unstable species such as hydrogen peroxide (H 2 O 2 ). Plasma of I-CAED spark is characterized by high electron density and near-thermal equilibrium, emitting a continuous ultraviolet spectrum. The combination of these different discharge parts makes I-CAED in water a highly effective tool for the Advanced Oxidation Process, particularly in water disinfection. Experimentally demonstrated Electric Energy per Order value for disinfection of E. coli-contaminated water is as low as 0.135 ± 0.035 kWh/m 3 /order. Estimates show that the implementation of “dry electrodes” configuration reduces the erosion rate of the electrode material by at least one order of magnitude. Spectral analysis reveals that the continuum emission generated by I-CAED in proximity to metal electrodes deviates from the spectra of discharges spatially decoupled from the electrodes. We assume that this spectral divergence is attributable to blackbody-like emission originating from metallic nanoparticles form during the electrode's erosion process.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

On the origins of the continuum radiation of an underwater nanosecond pulsed discharge: an absolute-intensity optical emission spectroscopy study

The plasma properties of an underwater nanosecond pulsed discharge remain not fully understood despite being extensively studied for several decades. In this work, we focus on the continuum radiation generated in such discharges. The discharge is characterized by power measurements as well as by absolute emission spectroscopy. When observed, Stark broadenings of H α , H β and O (777 nm) are employed for electron number densities measurements. The discharge was generated by a 10 ns main voltage pulse followed by multiple secondary pulses, which last up to 4 μs after the primary pulse. It is shown that a peak power of 3.5 MW and energy of 35 mJ is coupled during the main voltage pulse. A quantitative estimation of the different possible continuum radiation sources is performed through analytical calculations. This includes emission (blackbody, free–bound and free–free bremsstrahlung radiations) and absorption (electron–ion and electron–neutral free–free inverse bremsstrahlung) mechanisms. Our results suggest that electron–neutral free–free bremsstrahlung is the principal mechanism responsible for the strong continuum radiation observed experimentally during the primary pulse. We also show that self-absorption through electron–neutral (and electron–ion) inverse bremsstrahlung plays an important role in the main discharge pulse. Further, our results indicate the non-negligible additional contribution of the H 2 continuum during the first reflected pulse which is likely ignited in bubbles generated by the first discharge pulse.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Robustness of cosmic birefringence measurement against Galactic foreground emission and instrumental systematics

The polarization of the cosmic microwave background (CMB) can be used to search for parity-violating processes like that predicted by a Chern-Simons coupling to a light pseudoscalar field. Such an interaction rotates E modes into E modes in the observed CMB signal through an effect known as cosmic birefringence. Even though isotropic birefringence can be confused with the rotation produced by a miscalibration of the detectors' polarization angles, the degeneracy between both effects is broken when Galactic foreground emission is used as a calibrator. Here, in this work, we use realistic simulations of the High-Frequency Instrument of the Planck mission to test the impact that Galactic foreground emission and instrumental systematics have on the recent birefringence measurements obtained through this technique. Our results demonstrate the robustness of the methodology against the miscalibration of polarization angles and other systematic effects, like intensity-to-polarization leakage, beam leakage, or cross-polarization effects. However, our estimator is sensitive to the EB correlation of polarized foreground emission. Here we propose to correct the bias induced by dust EB by modeling the foreground signal with templates produced in Bayesian component-separation analyses that fit parametric models to CMB data. Acknowledging the limitations of currently available dust templates like that of the Commander sky model, high-precision CMB data and a characterization of dust beyond the modified blackbody paradigm are needed to obtain a definitive measurement of cosmic birefringence in the future.

79 ASTRONOMY AND ASTROPHYSICS↗