Search NASA⌕ Search

SEARCH · Search NASA

Results for “Bone Fracture”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 55 records · Page 3

Optimization of a Lethal, Combat-Relevant Model of Sterile Inflammation in Mice for Drug Candidate Screening

ABSTRACT Introduction Extensive trauma, commonly seen in wounded military Service Members, often leads to a severe sterile inflammation termed systemic inflammatory response syndrome (SIRS), which can progress to multiple organ dysfunction syndrome (MODS) and death. MODS is a serious threat to wounded Service Members, historically causing 10% of all deaths in trauma admissions at a forward deployed combat hospital. The importance of this problem will be exacerbated in large-scale combat operations, in which evacuation will be delayed and care of complex injuries at lower echelons of care may be prolonged. The main goal of this study was to optimize an existing mouse model of lethal SIRS/MODS as a therapeutic screening platform for the evaluation of immunomodulatory drugs. Materials and Methods Male C57BL/6 mice were euthanized, and the bones and muscles were collected and blended into a paste termed tissue–bone matrix (TBX). The TBX at 12.5%–20% relative to body weight of each recipient mouse was implanted into subcutaneous pouches created on the dorsum of anesthetized animals. Mice were observed for clinical scores for up to 48 hours postimplantation and euthanized at the preset point of moribundity. To test effects of anesthetics on TBX-induced mortality, animals received isoflurane or ketamine/xylazine (K/X). In a separate set of studies, mice received TBX followed by intraperitoneal injection with 20 mg/kg or 40 mg/kg Eritoran or a placebo carrier. All Eritoran studies were performed in a blinded fashion. Results We observed that K/X anesthesia significantly increased the lethality of the implanted TBX in comparison to inhaled anesthetics. Although all the mice anesthetized with isoflurane and implanted with 12.5% TBX survived for 24 hours, 60% of mice anesthetized with K/X were moribund by 24 hours postimplantation. To mimic more closely the timing of lethal SIRS/MODS following polytrauma in human patients, we extended observation to 48 hours. We performed TBX dose–response studies and found that as low as 15%, 17.5%, and 20% TBX caused moribundity/mortality in 50%, 80%, and 100% mice, respectively, over a 48-hour time period. With 17.5% TBX, we tested if moribundity/mortality could be rescued by anti-inflammatory drug Eritoran, a toll-like receptor 4 antagonist. Neither 20 mg/kg nor 40 mg/kg doses of Eritoran were found to be effective in this model. Conclusions We optimized a TBX mouse model of SIRS/MODS for the purpose of evaluating novel therapeutic interventions to prevent trauma-related pathophysiologies in wounded Service Members. Negative effects of K/X on lethality of TBX should be further evaluated, particularly in the light of widespread use of ketamine in treatment of pain. By mimicking muscle crush, bone fracture, and necrosis, the TBX model has pleiotropic effects on physiology and immunology that make it uniquely valuable as a screening tool for the evaluation of novel therapeutics against trauma-induced SIRS/MODS.

General & Internal Medicine↗

Fibers and materials of medical application

Efferent sorption methods of organism detoxication (by medical trend) are presented. Recently, specialists have shown their keen interest in the problem of treating exogenous and endogenous intoxications. This was stipulated by the growing production and accumulation of chemical products for industrial, agricultural, and domestic needs. To solve this problem the industrial production of carbon fibrous adsorbents was developed and implemented at NII Chimvolokno in St. Petersburg. A description of the carbon fibers is given. Also, application of modern composite materials for manufacturing compression-distraction apparatus used for setting fractured bones is described.

Fridman, L. I.↗

The Physiology of Bed Rest

Prolonged rest in bed has been utilized by physicians and other health-care workers to immobilize and confine patients for rehabilitation and restoration of health since time immemorial. The sitting or horizontal position is sought by the body to relieve the strain of the upright or vertical postures, for example during syncopal situations, bone fractures, muscle injuries, fatigue, and probably also to reduce energy expenditure. Most health-care personnel are aware that adaptive responses occurring during bed rest proceed concomitantly with the healing process; signs and symptoms associated with the former should be differentiated from those of the latter. Not all illnesses and infirmities benefit from prolonged bed rest. Considerations in prescribing bed rest for patients-including duration, body position, mode and duration of exercise, light-dark cycles, temperature, and humidity-have not been investigated adequately. More recently, adaptive physiological responses have been measured in normal, healthy subjects in the horizontal or slightly head-down postures during prolonged bed rest as analogs for the adaptive responses of astronauts exposed to the microgravity environment of outer and bed-rest research.

Fortney, Suzanne M.↗

Evaluation of Critical Care Monitor Technology During the US Navy Strong Angel Exercise

The NASA critical path road map identifies "trauma and acute medical problems" as a clinical capability risk category (http://criticalDath.isc.nasa.gov). Specific risks include major trauma, organ laceration or contusion, hemoperitoneum, pulmonary failure, pneumo- and hemothorax, burn, open bone fracture, blunt head trauma, and penetrating injury. Mitigation of these risks includes the capability for critical care monitoring. Currently, the International Space Station (ISS) Crew Health Care System (CHeCS) does not provide such a capability. The Clinical Space Medicine Strategic Planning Forum (4/8/97), sponsored by NASA Medical Operations, identified the development of trauma care capabilities as one of the top priorities for space medicine. The Clinical Care Capability Development Project (CCCDP) subsequently undertook the task to address this need.

Johannesen, John↗

Smart Ultrasound Remote Guidance Experiment (SURGE)- Concept of Operations Evaluation for Using Remote Guidance Ultrasound for Planetary Space Flight

Introduction Use of remote guidance (RG) techniques aboard the International Space Station (ISS) has enabled astronauts to collect diagnostic-level ultrasound images. Exploration class missions will require this cohort of (typically) non-formally trained sonographers to operate with greater autonomy given the longer communication delays (2 seconds for ISS vs. >6 seconds for missions beyond the Moon) and communication blackouts. To determine the feasibility and training requirements for autonomous ultrasound image collection by non-expert ultrasound operators, ultrasound images were collected from a similar cohort using three different image collection protocols: RG only, RG with a computer-based learning tool (LT), and autonomous image collection with LT. The groups were assessed for both image quality and time to collect the images. Methods Subjects were randomized into three groups: RG only, RG with LT, and autonomous with LT. Each subject received 10 minutes of standardized training before the experiment. The subjects were tasked with making the following ultrasound assessments: 1) bone fracture and 2) focused assessment with sonography in trauma (FAST) to assess a patient s abdomen. Human factors-related questionnaire data were collected immediately after the assessments. Results The autonomous group did not out-perform the two groups that received RG. The mean time for the autonomous group to collect images was less than the RG groups, however the mean image quality for the autonomous group was less compared to both RG groups. Discussion Remote guidance continues to produce higher quality ultrasound images than autonomous ultrasound operation. This is likely due to near-instant feedback on image quality from the remote guider. Expansion in communication time delays, however, diminishes the capability to provide this feedback, thus requiring more autonomous ultrasound operation. The LT has the potential to be an excellent training and coaching component for autonomous ultrasound image collection during exploration missions.

Hurst, Victor, IV↗

NASA Tech Briefs, September 2006

Topics covered include: Improving Thermomechanical Properties of SiC/SiC Composites; Aerogel/Particle Composites for Thermoelectric Devices; Patches for Repairing Ceramics and Ceramic- Matrix Composites; Lower-Conductivity Ceramic Materials for Thermal-Barrier Coatings; An Alternative for Emergency Preemption of Traffic Lights; Vehicle Transponder for Preemption of Traffic Lights; Automated Announcements of Approaching Emergency Vehicles; Intersection Monitor for Traffic-Light-Preemption System; Full-Duplex Digital Communication on a Single Laser Beam; Stabilizing Microwave Frequency of a Photonic Oscillator; Microwave Oscillators Based on Nonlinear WGM Resonators; Pointing Reference Scheme for Free-Space Optical Communications Systems; High-Level Performance Modeling of SAR Systems; Spectral Analysis Tool 6.2 for Windows; Multi-Platform Avionics Simulator; Silicon-Based Optical Modulator with Ferroelectric Layer; Multiplexing Transducers Based on Tunnel-Diode Oscillators; Scheduling with Automated Resolution of Conflicts; Symbolic Constraint Maintenance Grid; Discerning Trends in Performance Across Multiple Events; Magnetic Field Solver; Computing for Aiming a Spaceborne Bistatic- Radar Transmitter; 4-Vinyl-1,3-Dioxolane-2-One as an Additive for Li-Ion Cells; Probabilistic Prediction of Lifetimes of Ceramic Parts; STRANAL-PMC Version 2.0; Micromechanics and Piezo Enhancements of HyperSizer; Single-Phase Rare-Earth Oxide/Aluminum Oxide Glasses; Tilt/Tip/Piston Manipulator with Base-Mounted Actuators; Measurement of Model Noise in a Hard-Wall Wind Tunnel; Loci-STREAM Version 0.9; The Synergistic Engineering Environment; Reconfigurable Software for Controlling Formation Flying; More About the Tetrahedral Unstructured Software System; Computing Flows Using Chimera and Unstructured Grids; Avoiding Obstructions in Aiming a High-Gain Antenna; Analyzing Aeroelastic Stability of a Tilt-Rotor Aircraft; Tracking Positions and Attitudes of Mars Rovers; Stochastic Evolutionary Algorithms for Planning Robot Paths; Compressible Flow Toolbox; Rapid Aeroelastic Analysis of Blade Flutter in Turbomachines; General Flow-Solver Code for Turbomachinery Applications; Code for Multiblock CFD and Heat-Transfer Computations; Rotating-Pump Design Code; Covering a Crucible with Metal Containing Channels; Repairing Fractured Bones by Use of Bioabsorbable Composites; Kalman Filter for Calibrating a Telescope Focal Plane; Electronic Absolute Cartesian Autocollimator; Fiber-Optic Gratings for Lidar Measurements of Water Vapor; Simulating Responses of Gravitational-Wave Instrumentation; SOFTC: A Software Correlator for VLBI; Progress in Computational Simulation of Earthquakes; Database of Properties of Meteors; Computing Spacecraft Solar-Cell Damage by Charged Particles; Thermal Model of a Current-Carrying Wire in a Vacuum; Program for Analyzing Flows in a Complex Network; Program Predicts Performance of Optical Parametric Oscillators; Processing TES Level-1B Data; Automated Camera Calibration; Tracking the Martian CO2 Polar Ice Caps in Infrared Images; Processing TES Level-2 Data; SmaggIce Version 1.8; Solving the Swath Segment Selection Problem; The Spatial Standard Observer; Less-Complex Method of Classifying MPSK; Improvement in Recursive Hierarchical Segmentation of Data; Using Heaps in Recursive Hierarchical Segmentation of Data; Tool for Statistical Analysis and Display of Landing Sites; Automated Assignment of Proposals to Reviewers; Array-Pattern-Match Compiler for Opportunistic Data Analysis; Pre-Processor for Compression of Multispectral Image Data; Compressing Image Data While Limiting the Effects of Data Losses; Flight Operations Analysis Tool; Improvement in Visual Target Tracking for a Mobile Robot; Software for Simulating Air Traffic; Automated Vectorization of Decision-Based Algorithms; Grayscale Optical Correlator Workbench; "One-Stop Shopping" for Ocean Remote-Sensing and Model Data; State Analysis Database Tool; Generating CAHV and CAHVOmages with Shadows in ROAMS; Improving UDP/IP Transmission Without Increasing Congestion; FORTRAN Versions of Reformulated HFGMC Codes; Program for Editing Spacecraft Command Sequences; Flight-Tested Prototype of BEAM Software; Mission Scenario Development Workbench; Marsviewer; Tool for Analysis and Reduction of Scientific Data; ASPEN Version 3.0; Secure Display of Space-Exploration Images; Digital Front End for Wide-Band VLBI Science Receiver; Multifunctional Tanks for Spacecraft; Lightweight, Segmented, Mostly Silicon Telescope Mirror; Assistant for Analyzing Tropical-Rain-Mapping Radar Data; and Anion-Intercalating Cathodes for High-Energy- Density Cells.

Source record↗

Biomechanical Analysis of Treadmill Locomotion on the International Space Station

Treadmill locomotion exercise is an important aspect of ISS exercise countermeasures. It is widely believed that an optimized treadmill exercise protocol could offer benefits to cardiovascular and bone health. If training heart rate is high enough, treadmill exercise is expected to lead to improvements in aerobic fitness. If impact or bone loading forces are high enough, treadmill exercise may be expected to contribute to improved bone outcomes. Ground-based research suggests that joint loads increase with increased running speed. However, it is unknown if increases in locomotion speed results in similar increases in joint loads in microgravity. Although data exist regarding the biomechanics of running and walking in microgravity, a majority were collected during parabolic flight or during investigations utilizing a microgravity analog. The Second Generation Treadmill (T2) has been in use on the International Space Station (ISS) and records the ground reaction forces (GRF) produced by crewmembers during exercise. Biomechanical analyses will aid in understanding potential differences in typical gait motion and allow for modeling of the human body to determine joint and muscle forces during exercise. By understanding these mechanisms, more appropriate exercise prescriptions can be developed that address deficiencies. The objective of this evaluation is to collect biomechanical data from crewmembers during treadmill exercise prior to and during flight. The goal is to determine if locomotive biomechanics differ between normal and microgravity environments and to determine how combinations of subject load and speed influence joint loading during in-flight treadmill exercise. Further, the data will be used to characterize any differences in specific bone and muscle loading during locomotion in these two gravitational conditions. This project maps to the HRP Integrated Research Plan risks including Risk of Bone Fracture (Gap B15), Risk of Early Onset Osteoporosis Due to Spaceflight (Gap B15), Risk of Impaired Performance Due to Reduced Muscle Mass, Strength, and Endurance (Gaps M3, M4, M6, Ml, M8, M9) and Risk of reduced Physical Performance Capabilities Due to Reduce Aerobic Capacity (Gaps M7, M8, M9).

De Witt, J. K.↗

Novel Musculoskeletal Loading System for Small Exercise Devices

Long duration spaceflight places astronauts at increased risk for muscle strain and bone fracture upon return to a 1-g or partial gravity environment. Functionally limiting decrements in musculoskeletal health are likely during Mars proving-ground and Earth-independent missions given extended transit times and the vehicle limitations for exercise devices (low-mass, small volume, little to no power). This is particularly alarming for exploration missions because astronauts will be required to perform novel and physically demanding tasks (i.e. vehicle egress, exploration, and habitat building activities) on unfamiliar terrain. Accordingly, NASA's exploration roadmap identifies the need for development of small exercise equipment that can prevent musculoskeletal atrophy and has the ability to assess musculoskeletal health at multiple time points during long-duration missions.

Downs, Meghan↗

Development and Comparison of an Artificial Gravity Concept for Human Spaceflight

This Internship served as a resource to find specific research about the many facets of artificial gravity. With three main areas to be addressed in detail: the negative health effects of microgravity and how current mitigation methods fall short, the knowns and unknowns of artificial gravity as a countermeasure, and past artificial gravity habitat concepts. This report primarily focuses on the negative health effects of microgravity and how current mitigation methods fall short. Through NASA resources such as the NTRS, and external sources such as the AIAA, research papers were gathered that were pertinent to the topic. Each paper was uploaded to a NASA SharePoint and abstracts were drafted to highlight the important information. The expected results were to build a library of easily accessible information that would allow for Ryan Joyce and Gabe Merrill to easily get up to speed on relevant information. This process should allow for a faster period of understanding with high relevancy material. The ability to quickly reference data will help to build an informed and detailed case for any future proposals on artificial gravity. This also prevents the need to spend many hours searching for relevant documentation, allowing for more time to be dedicated to the creation process. The project has successfully met expectations and is continuing to add pertinent documentation. Current research shows great potential for artificial gravity as a countermeasure on long duration missions. The gravity like forces created in an artificial gravity ship could help to prevent serious problems such as muscle loss, bone fractures, vision loss due to increased intracranial pressure, and would allow for transition to other gravity environments with little to no recovery period. These conditions are highly favorable for long duration missions as current mitigation methods have yet to be proven beyond one year in space and often only slow symptoms instead of preventing them.

Alice Elberfeld↗

Human System Risk Changes in 2021

The Human System Risk Board (HSRB) has the overall responsibility for tracking the evolution of the top ~30 human system risks that it has identified to be associated with human spaceflight. As part of this process, the Board is charged with maintaining a consistent, integrated process to mitigate those risks, and developing evidence-based risk posture recommendations. Risks are re-evaluated in a Continuous Risk Management (CRM) process. This session will summarize the risk posture changes that have occurred in the last year and what high level research, performance, and epidemiologic data have informed those changes. Human System Risks updated in 2021 include: Dynamic Loads, Sensorimotor, EVA, Crew Egress, Behavioral Medicine, Electrical Shock, Human System Integration Architecture (HSIA), Toxic Exposure, Bone Fracture, Cardiovascular, Medical Conditions, Renal Stone, CO2 Exposure, and Pharmacology.

Mary Van Baalen↗

Irreversibility of advanced osteoporosis: Limited role for pharmacologic intervention

Osteoporosis is of medical interest only because it increases bone fragility and risk of fracture, and except for relief of symptoms, preventing fracture is the only purpose of intervention. To prevent the first fracture, adequate bone density must be accumulated and conserved, but to prevent subsequent fracture, bone density must be augmented so that the supportive function of the skeleton can be restored. Almost 50 years after the recognition of post menopausal osteoporosis as a clinical entity, not one of the many treatments that have been used has been demonstrated to be efficacious in reducing subsequent fracture risk. My purpose is not to recite this chronicle of disappointment, but to account for it in terms of bone biology, to consider some possible exceptions, and to reiterate the importance of preventing damage to the skeleton rather than belatedly attempting its repair.

Parfitt, A. M.↗

An Elastic Analysis of a Plated Bone to Determine Fracture Gap Motion

An elastic analysis to determine fracture gap motions occurring in the osteotomized and plated canine femur was performed using the finite element program NASTRAN. The femur was idealized as a hollow right cylinder, and transverse anisotropy was assumed for the elastic properties of the bone. A 3-D 360 degree model consisting of 224 isoparametric quadrilateral hexahedral and 11 beam elements was created. A range of plate stiffnesses was tested by varying the modulus of elasticity of the plate from 207 GPa to 1 GPA. Moments were applied in the plane of the plate, about the axis of the plate, and in the plane of the screws. Results showed that, for plates of typical geometry and elastic modulus under 10 GPa, the contribution to fracture gap motion occurring due to deformation in the bone was negligible compared to that contribution from deformation in the plate.

Cooke, F. W.↗

A Biomechanical Approach to Assessing Hip Fracture Risk

Bone loss in microgravity is well documented, but it is difficult to quantify how declines in bone mineral density (BMD) contribute to an astronaut's overall risk of fracture upon return. This study uses a biomechanical approach to assessing hip fracture risk, or Factor of Risk (Phi), which is defined as the ratio of applied load to bone strength. All long-duration NASA astronauts from Expeditions 1-18 were included in this study (n=25), while crewmembers who flew twice (n=2) were treated as separate subjects. Bone strength was estimated based on an empirical relationship between areal BMD at the hip, as measured by DXA, and failure load, as determined by mechanical testing of cadaver femora. Fall load during a sideways fall was calculated from a previously developed biomechanical model, which takes into account body weight, height, gender, and soft tissue thickness overlying the lateral aspect of the hip that serves to attenuate the impact force. While no statistical analyses have been performed yet, preliminary results show that males in this population have a higher FOR than females, with a post- flight Phi of 0.87 and 0.36, respectively. FOR increases 5.1% from preflight to postflight, while only one subject crossed the fracture "threshold" of Phi = 1, for a total of 2 subjects with a postflight Phi > 1. These results suggest that men may be at greater risk for hip fracture due largely in part to their relatively thin soft tissue padding as compared to women, since soft tissue thickness has the highest correlation (R(exp 2)= .53) with FOR of all subject-specific parameters. Future work will investigate changes in FOR during recovery to see if baseline risk levels are restored upon return to 1-g activity. While dual x-ray absorptiometry (DXA) is the most commonly used clinical measure of bone health, it fails to provide compartment-specific information that is useful in assessing changes to bone quality as a result of microgravity exposure. Peripheral quantitative computed tomography (pQCT) accomplishes this by imaging transverse "slices" of the long bones. This project was a re-analysis of a 90 day bed rest study to determine if changes to cortical and trabecular compartments could be detected in the distal tibia with statistical significance using a new pQCT image analysis method. Nearly all changes in bone mineral density (BMD) and cross sectional area (CSA) measures were seen with statistical significance, with the exception of a change in cortical BMD. Total bone CSA increased by 1.1 % (p =0.01), cortical CSA decreased by - 5.6% (p<0.001) and trabecular CSA increased by 1.76% (p=0.007); the combination of which suggests bone resorption occurred at the endocortical surface in response to mechanical unloading by bed rest. Furthermore, total BMD and trabecular BMD decreased (-3.8%, p=0.001 and -2.8%, p =0.007, respectively), while decreases in cortical BMD failed to reach significance (-1.2%, p=0.07). Given that compartment-specific changes are seen with significance and are likely to influence bone strength, it is recommended that pQCT remain a standard measure used in bed rest because it provides a unique measure by which to better evaluate the efficacy of countermeasures to microgravity-induced bone loss.

Ellman, Rachel↗

The effect of loading direction on the fracture behaviors of cortical bone at a dynamic loading rate

Here, the dynamic cracking processes in porcine cortical bone were visualized in real-time using the high-speed synchrotron X-ray phase-contrast imaging (PCI) technique in three osteon orientations: in-plane transverse, out-of-plane transverse and in-plane longitudinal. The dynamic flexural loading applied on the pre-notched bone specimens was introduced by a modified Kolsky compression bar. High-speed X-ray images of the entire loading events were documented with a high-speed camera. Three-dimensional X-ray micro-computed tomography was conducted to examine the intact microstructures and obtain the basic material properties of the bone material used for mechanical characterizations. The onset location, where crack initiated, and the subsequent direction, along which the incipient crack propagated, were measured quantitatively using the high-speed X-ray images and the latter was found dependent on the osteon direction significantly. The crack propagation velocities were dependent on crack extension over the entire crack path significantly for all the three directions while the initial velocity for in-plane longitudinal direction was lower than the other two directions. Straight-through crack paths were observed for in-plane longitudinal specimens while the cracks were deflected and twisted in the in-plane transverse direction. For out-of-plane transverse direction, the cracks follow paths with tortuosity fall in between the other two directions, showing a mixed mode of fractures of the former two extreme cases. The toughening mechanisms, visualized by the high-speed X-ray images, and the corresponding fracture toughness, evaluated in terms of fracture initiation toughness and crack growth resistance curve (R-curve), were also found significantly different among the three osteon directions, suggesting an overall transition from brittle to ductile-like fracture behaviors at the dynamic displacement rate (5.4 m/s) as the osteon orientation varies from in-plane longitudinal to out-of-plane transverse, and to in-plane transverse eventually.

42 ENGINEERING↗

The Role of Calcium in Osteoporosis

Calcium requirements may vary throughout the lifespan. During the growth years and up to age 25 to 30, it is important to maximize dietary intake of calcium to maintain positive calcium balance and achieve peak bone mass, thereby possibly decreasing the risk of fracture when bone is subsequently lost. Calcium intake need not be greater than 800 mg/day during the relatively short period of time between the end of bone building and the onset of bone loss (30 to 40 years). Starting at age 40 to 50, both men and women lose bone slowly, but women lose bone more rapidly around the menopause and for about 10 years after. Intestinal calcium absorption and the ability to adapt to low calcium diets are impaired in many postmenopausal women and elderly persons owing to a suspected functional or absolute decrease in the ability of the kidney to produce 1,25(OH)2D2. The bones then become more and more a source of calcium to maintain critical extracellular fluid calcium levels. Excessive dietary intake of protein and fiber may induce significant negative calcium balance and thus increase dietary calcium requirements. Generally, the strongest risk factors for osteoporosis are uncontrollable (e.g., sex, age, and race) or less controllable (e.g., disease and medications). However, several factors such as diet, physical activity, cigarette smoking, and alcohol use are lifestyle related and can be modified to help reduce the risk of osteoporosis.

Arnaud, C. D.↗

Osteocytic oxygen sensing: Distinct impacts of VHL and HIF-2alpha on bone integrity

Skeletal fracture resistance emerges from multiple components of bone structure like microarchitecture, matrix mineralization, and organization. These characteristics are engendered via mechanisms like the hypoxia-inducible factors (HIF) pathway, involving two paralogs, HIF-1α and HIF-2α. Under normoxia, HIF-α is targeted for degradation via von-Hippel Lindau (VHL); hypoxia enables HIF-α stabilization and induction of target genes. We previously showed that osteocytic Vhl deletion or expression of degradation-resistant HIF-2α cDR female mice each produced high bone mass, whereas degradation-resistant osteocytic HIF-1α produced no overt phenotype. We report within that Vhl cKO increased bone strength, while HIF-2α cDR displayed markedly reduced bone strength below Cre-negative controls. This suggests that VHL and HIF-2α drive distinct responses that promote disparate effects on bone strength. Both Vhl deletion or HIF-2α accumulation generated two discrete bone morphologies: an outer lamellar cortex and a woven, poorly mineralized endocortex that imparted dramatically different functional outcomes. Our studies reveal novel influence of osteocytic HIF-2α signaling on collagen matrix organization, mineralization, and bone strength.

60 APPLIED LIFE SCIENCES↗

Male Astronauts Have Greater Bone Loss and Risk of Hip Fracture Following Long Duration Spaceflights than Females

This slide presentation reviews bone loss in males and compares it to female bone loss during long duration spaceflight. The study indicates that males suffer greater bone loss than females and have a greater risk of hip fracture. Two possible reason for the greater male bone loss are that the pre-menopausal females have the estrogen protection and the greater strength of men max out the exercise equipment that provide a limited resistance to 135 kg.

Ellman, Rachel↗

Effect of Ex Vivo Ionizing Radiation on Static and Fatigue Properties of Mouse Vertebral Bodies

For a variety of medical and scientific reasons, human bones can be exposed to a wide range of ionizing radiation levels. In vivo radiation therapy (0.05 kGy) is used in cancer treatment, and ex vivo irradiation (25-35 kGy) is used to sterilize bone allografts. Ionizing radiation in these applications has been shown to increase risk of fracture, decrease bone quality and degrade collagen integrity. Past studies have investigated the deleterious effects of radiation on cortical or trabecular bone specimens individually, but to date no studies have examined whole bones containing both cortical and trabecular tissue. Furthermore, a clear relationship between the dose and the mechanical and biochemical response of bone's extracellular matrix has yet to be established for doses ranging from cancer therapy to allograft sterilization (0.05-35 kGy). To gain insight into these issues, we conducted an ex vivo radiation study to investigate non-cellular (i.e. matrix) effects of ionizing radiation dose on vertebral whole bone mechanical properties, over a range of radiation doses (0.05-35 kGy), with a focus on any radiation-induced changes in collagen. With underlying mechanisms of action in mind, we hypothesized that any induced reductions in mechanical properties would be associated with changes in collagen integrity. METHODS: 20-week old female mice were euthanized and the lumbar spine was dissected using IACUC approved protocols. The lumbar vertebrae (L1- S1) were extracted from the spine via cuts through adjacent intervertebral discs, and the endplates, posterior processes, surrounding musculature, and soft tissues were removed (approx. 1.5mm diameter, approx. 2mm height). Specimens were randomly assigned to one of five groups for ex vivo radiation exposure: x-ray irradiation at 0.05, 1, 17, or 35 kGy, or a 0 kGy control. Following irradiation, the vertebrae were imaged using microcomputed tomography (micro-CT) and then subjected to either monotonic compressive loading to failure or uniform cyclic compressive loading. During cyclic testing, samples were loaded in force control to a force level that corresponded to a strain of 0.46%, as determined in advance by a linearly elastic micro-CT-based finite element analysis for each specimen. Tests were stopped at imminent fracture, defined as a rapid increase in strain. The main outcome for the monotonic test was the strength (maximum force); for cyclic testing it was the fatigue life (log of the number of cycles of loading at imminent failure). A fluorometric assay was used on the S1 vertebrae to measure the number of non-enzymatic collagen crosslinks[4]. A one-way ANOVA was performed on mechanical properties and collagen crosslinks; means were compared with controls using Dunnett's method, with a Tukey-Kramer post-hoc analysis when significance was found (p < or = 0.05). RESULTS: Compared to the unirradiated control group, the concentration of non-enzymatic collagen crosslinks was significantly increased for all irradiated groups (p < 0.0001), and being higher by at least 50% (Figure 1a). By contrast, the radiation effects on the collagen were only evident at the higher doses. For irradiation exposures of 17 kGy or more, strength decreased substantially as the radiation level was increased, but no effect was evident below 17 kGy (Figure 1b). There was no significant change in the stiffness or maximum displacement for any radiation dose (p>0.05). The finite element analysis prescribed force level for cyclic loading exceeded the measured (monotonic) strength of the 17 and 35 kGy irradiated groups (mean +/- SD, 20.6 +/- 5.6 N; 13.2 +/- 3.7 N, respectively) and therefore these groups were eliminated from the fatigue study. The fatigue life for the 0.05 and 1 kGy groups were similar to each other and were not statistically significantly different from the control group (Figure 1c).

radiation↗