Search NASA⌕ Search

SEARCH · Search NASA

Results for “Booster”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 55 records · Page 3

Booster Cavity Damper Redesign for PIP-II

A new Higher Order Mode (HOM) damper was designed and tested for the Booster accelerator cavity at Fermilab. In anticipation of the PIP-II upgrade, it was discovered that the higher beam intensity of PIP-II may cause beam instability due to an excited mode at 106 MHz. This unfortunately corresponds with the cavity s 2nd order harmonic mode, which will sweep from 86-105.7 MHz. The new damper is a modification of an existing damper that was designed to reduce an existing static HOM at 83 MHz, with the new design intending to cover the 2nd order HOM as well. The existing damper uses an inductive coupling loop to extract RF energy from the cavity which then goes through a filter in order to reflect the fundamental frequency back into the cavity while passing HOMs to a dump load. The new damper intends to replace the filter portion of the system with a wider band variant while also changing the topology from a coaxial cable loop filter to a componentized PCB-based design. Primary design challenges include bandwidth coverage, impedance matching of the various modes, long term thermal and mechanical stability, radiation hardness, and high voltage handling. Initial designs achieved the desired damping but were found to quickly succumb to destructive arcing due to the voltages present. More finalized designs intend to address this problem through circuit design modifications as well as the use of hardier components.

Pieper, Dustin [Fermilab]↗

Estimating Residual Gas Beam Loss in the BNL AGS Booster:Model, Numerical Tools, and Implications for a Polarimeter Chamber

Beamloss from residual gas scattering is calculated for a storage ring of circumference C = 200m, covering a linear magnetic rigidity ramp from B ρ inj = 1.25Tm to B ρ ext = 9.50Tm over tramp = 1.00s. Three loss mechanisms are considered: nuclear inelastic reactions, single Coulomb scattering beyond the acceptance angle of the machine, and charge-state exchange for heavy ions. Calculations are performed for protons and Au 32+ ions, the latter being the charge state delivered by the EBIS pre-injector into the BNL AGS Booster. At a baseline vacuum of P 0 = 5 × 10 −11 mbar the integrated fractional beam loss over the full ramp is negligible for protons (< 0.001%) and 33.1% for Au 32+ . The impact of a 1m polarimeter section at elevated pressure P s = 5 × 10 −9 mbar is evaluated: the proton loss remains negligible, while the Au 32+ loss rises to 45.1%, establishing the vacuum requirement for the polarimeter chamber. In the present compact approximate model, Au 32+ losses are dominated by charge exchange at injection, while proton losses are dominated by single Coulomb scattering. The design, outgassing budget, pumping strategy, and commissioning sequence for a UHV polarimeter chamber housing silicon detectors and ASICs are described in detail.

43 PARTICLE ACCELERATORS↗

Performance of the ICARUS Trigger System at the Booster and NuMI Neutrino Beams †

The ICARUS-T600 liquid argon time projection chamber detector takes data at a shallow depth as the far detector of the Short Baseline Neutrino program at Fermilab, searching for sterile neutrinos with the Booster and Main Injector neutrino beams. The ICARUS trigger system exploits the temporal coincidence of the beams with scintillation light signals detected by 360 photo-multiplier tubes in limited TPC regions. The trigger efficiency measurement leverages cosmic rays collected without any scintillation light requirement, with timing from an external cosmic ray tagger system. The efficiency measured with stopping muons roughly saturates at ∼300 MeV, covering most of the expected energy range of charged-current neutrino interactions. For the latest ICARUS physics runs, special “adder” boards performing the analog sum of light signals were introduced as a complementary trigger to possibly recover low-energy neutrino interactions.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Shortened Booster Bunch Lengths

Booster typically produces beam bunches that have a phase space profile with a low momentum spread but high time spread, correlating to longer bunch lengths. The goal of this study is to produce beam bunches that have a phase space profile with a high momentum spread but low time spread or narrow bunch lengths. This can be achieved by slowly increasing the RF cavities amplitudes (Adiabatic Excitation) or by oscillating the amplitudes (Quadratic Bunch Rotation, QBR) until the desired bunch lengths are achieved. Results show that when shortening the bunches using QBR, it showed the bunches had a length of 0.6ns (within 1 sigma) but beam losses were being incurred in the 8 GeV line which were a result of beam dispersion.

Abdelhamid, Maan↗

Towards An Updated Simulation of the Booster Neutrino Beam

Precise, accurate neutrino flux predictions for neutrino beam experiments are crucial for physics results. Flux predictions for the Booster Neutrino Beam at Fermilab were first published in 2009 by the MiniBooNE collaboration. It is no longer possible to run the simulation used to create these predictions due to outdated software versions. In this exciting period for the Short-Baseline Neutrino Program at Fermilab, with both the far detector (ICARUS) and the near detector (SBND) operating, an updated flux model for the BNB is necessary. For the purpose of using a dynamic, up-to-date beam model, the SBN program has created a new simulation named G4BNB. This framework contains new features, such as a full neutrino ancestry to handle hadron production systematics with more precision, and the inclusion of neutral mesons from the proton-beryllium scatter to allow the study of exotic BSM scenarios.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

First search for sterile neutrino oscillation leading to $ν_μ$ disappearance in the Booster Neutrino Beam at ICARUS

We present a search for muon neutrino disappearance in the Booster Neutrino Beam (BNB) at Fermilab using the ICARUS detector. Neutrino interactions identified as muon neutrinos interacting with argon nuclei via the charged current interaction and having only a muon and at least one proton in the final state (1$μ$Np) have been selected from data collected in 2022-2023 (ICARUS Run 2) and compared with a simulation-based expectation. In the context of a fit to a two-neutrino approximation of the sterile 3+1 model, including the impact of systematic uncertainty from the flux, neutrino interaction, and detector models, we find no statistically significant muon neutrino disappearance at the ICARUS baseline of 600 meters from the BNB target. Corresponding 90% C.L. exclusion contours in $Δm^2_{41}$ - sin$^22θ_{μμ}$ space are presented. This is the first oscillation analysis produced by ICARUS exposed to the BNB. We note that the analysis is systematics limited due to large unconstrained uncertainties from the flux and interaction models. In future joint analyses, data from ICARUS and the SBND detector, exposed to the BNB at 110 meters from target, will be combined to provide significant constraint of these uncertainties, enabling a robust, world-leading two-detector analysis.

Alrahman, F. Abd [Houston U.]↗

Laser-plasma ion beam booster based on hollow-channel magnetic vortex acceleration

Laser-driven ion acceleration provides ultrashort, high-charge, low-emittance beams, which are desirable for a wide range of high-impact applications. Yet after decades of research, a significant increase in maximum ion energy is still needed. This paper introduces a quality-preserving staging concept for ultraintense ion bunches that is seamlessly applicable from the nonrelativistic plasma source to the relativistic regime. Full three-dimensional particle-in-cell simulations prove robustness and capture of a high-charge proton bunch, suitable for readily available and near-term laser facilities.

43 PARTICLE ACCELERATORS↗

mRNA-LNP HIV-1 trimer boosters elicit precursors to broad neutralizing antibodies

Germline-targeting (GT) HIV vaccine strategies are predicated on deriving broadly neutralizing antibodies (bnAbs) through multiple boost immunogens. However, as the recruitment of memory B cells (MBCs) to germinal centers (GCs) is inefficient and may be derailed by serum antibody–induced epitope masking, driving further B cell receptor (BCR) modification in GC-experienced B cells after boosting poses a challenge. Using humanized immunoglobulin knockin mice, we found that GT protein trimer immunogen N332-GT5 could prime inferred-germline precursors to the V3-glycan–targeted bnAb BG18 and that B cells primed by N332-GT5 were effectively boosted by either of two novel protein immunogens designed to have minimum cross-reactivity with the off-target V1-binding responses. The delivery of the prime and boost immunogens as messenger RNA lipid nanoparticles (mRNA-LNPs) generated long-lasting GCs, somatic hypermutation, and affinity maturation and may be an effective tool in HIV vaccine development.

Science & Technology - Other Topics↗

Fermilab Booster Beam Emittances from Quadrupole Modes Measured BPMs

The measurement of beam emittances by extracting the quadrupole mode signal from a 4 plate beam position monitor (BPM) was published at least 40 years ago. Unfortunately, in practice, this method suffers from poor signal to noise ratio and requires a lot of tuning to extract out the emittances. In this paper, an improved method where multiple BPMs are used together with better mathematical analysis is described. The BPM derived emittances are then compared with those measured by the Ion Profile Monitor (IPM). Surprisingly, the BPM measured emittances behave very well and are more realistic than those measured by the IPM.

43 PARTICLE ACCELERATORS↗

Improving NOvA&#x27;s Sterile Neutrino Search with the Booster Neutrino Beam

The NOvA experiment’s most recent search for eV-scale sterile neutrinos is systematically limited in the region of parameter space where $\Delta m^2_{41} \gtrsim 1~\mathrm{eV}^2$. This region of parameter space is preferred by sterile neutrino interpretations of current experimental anomalies; improving sensitivity here is high-priority. When added directly into the fit, additional data samples which are subject to orthogonal systematic uncertainties act as in-situ constraints, breaking the degeneracy between systematic uncertainties and sterile-induced oscillations. The NOvA experiment consists of two functionally identical detectors, 14.6 mrad off-axis of the NuMI beam, with the Near Detector (Far Detector) 1 km (810 km) from the beam source. The Near Detector’s position on-site at Fermilab means that it is also able to observe neutrinos from a second neutrino beam, the BNB, 160 mrad off-axis. NOvA has been taking BNB data since 2015, but has not yet analysed these data. The BNB and NuMI are subject to different beam-related uncertainties, allowing us to leverage this sample as an in-situ constraint. This poster will present the current status, preliminary simulations, and potential additional uses of this unique experimental setup

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Future Sterile Neutrino Searches in NOvA using the Booster Neutrino Beam

The NOvA experiment’s most recent search for eV-scale sterile neutrinos under a 3+1 model simultaneously analyses muon neutrino and neutral current datasets from the NuMI beam at it's Near ($\sim$1 km baseline) and Far (810 km baseline) detectors to look for oscillations consistent with a sterile neutrino. The analysis is systematically limited in the region of parameter space where $\Delta m^{2}_{41} $>~1 eV^2$. This region of parameter space is preferred by sterile neutrino interpretations of current experimental anomalies and so improving sensitivity here is high-priority. The Near Detector’s position on-site at Fermilab means that it is also able to observe neutrinos from a second neutrino beam, the BNB, 160 mrad off-axis. This data probes a similar L/E to the NuMI data, but using a different neutrino energy, and being subject to different beam-related uncertainties. Jointly analysing these datasets can help us to constrain our systematic uncertainties, improving our sensitivity. NOvA has been taking BNB data since 2015, but has not yet analysed these data. This poster will present first sensitivities from the combined analysis of the BNB and NuMI datasets.

Lister, Adam [U. Wisconsin, Madison (main)]↗

Fermilab Booster Beam Emittances from Quadrupole Modes Measured by BPMs

The measurement of beam emittances by extracting the quadrupole mode signal from a 4 plate beam position monitor (BPM) was published at least 40 years ago. Unfortunately, in practice, this method suffers from poor signal to noise ratio and requires a lot of tuning to extract out the emittances. In this paper, an improved method where multiple BPMs are used together with better mathematical analysis is described. The BPM derived emittances are then compared with those measured by the Ion Profile Monitor (IPM). Surprisingly, the BPM measured emittances behave very well and are more realistic than those measured by the IPM.

43 PARTICLE ACCELERATORS↗

Electron Cooling in NICA Acceleration Complex

The Nuclotron-based Ion Collider fAcility (NICA) is under assembling at JINR. NICA will provide colliding beams for study of hot strongly interacting baryonic matter and spin physics. The NICA injection complex includes a tandem of 2 superconducting synchrotrons: Booster (up to 600 MeV/u) and Nuclotron (up 3.9 GeV/u fully stripped heavy ions). Since the start of injection complex commissioning in 2020 its four Runs were carried out. To the present time the beams of He, Fe, C and Xe were accelerated. Booster electron cooling was first used for cooling of continuous Fe¹⁴⁺ beam at the energy of 3.2 MeV/u in Run II. In the last Run we demonstrated longitudinal cooling of Xe²⁸⁺ in the presence of RF voltage at the Booster injection energy. This regime is required for accumulation in Booster the intensity required for Collider operation. The cooling enabled a 2 times intensity increase of slow extracted beam from Nuclotron. Optimization of Booster electron cooling for beam accumulation will be carried out in the next Run. Another (high voltage) electron cooling system will be used in the NICA Collider rings for ion accumulation in a barrier bucket and consecutive bunch formation.

43 PARTICLE ACCELERATORS↗

Experimental longitudinal emittance manipulation using laser-based photoionization in the Fermilab Linac

A series of simulations and beam studies were conducted at Fermilab’s linear accelerator to evaluate the effectiveness of longitudinal emittance control via laser-induced photoionization. While similar laser techniques have been employed at Fermilab to enhance injection and extraction efficiency into the Booster, the work presented here focuses on extending these methods to bunch-by-bunch manipulation. This approach utilizes fine-scale correction of the H- bunches’ longitudinal spatial distribution. In theory, loosely confined particles in longitudinal phase space contribute to emittance growth during acceleration. By selectively removing these outlying particles through laser scraping (H- + γ → H + e-), this growth can be reduced. This report presents experimental results from both symmetric and asymmetric longitudinal scraping of H⁻ bunches in the Fermilab linac, which were subsequently injected into Booster, and evaluates the broader applicability of this method for future high-intensity accelerator operations.

Landon, Parker [Boston U.; Fermilab]↗