Search NASA⌕ Search

SEARCH · Search NASA

Results for “Brayton”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 55 records · Page 3

The brayton cycle for space power

This paper reviews the basic features of the Brayton cycle and discusses the selection of such cycle parameters as working fluid, pressure, and temperature. System performance, weight, and reliability characteristics are then considered in order to determine the suitability of this type of system for the intended space applications. It is shown that the Brayton cycle can be considered suitable for low-power solar and intermediate-power nuclear applications where low specific weight is not a critical requirement. To achieve the low specific weights required for electrical propulsion missions, turbine-inlet temperatures in the 3000 R region at power levels in the 500–1000 kw range appear to be necessary.

ELECTRIC PROPULSION↗

Brayton Cycle Power Conversion Model for MW-Class Nuclear Electric Propulsion Mars Missions

A Brayton cycle based power conversion system for a nuclear electric propulsion application was modeled in Simulink as part of NASA’s space nuclear program in order to explore the impact of technology assumptions on the power conversion system performance and capabilities. The thermodynamic processes and algorithms within the model are documented, including a higher fidelity reactor model. Assumptions are chosen based on literature and subject matter expert review, and example results and capabilities of the model are shown. The effects of the turbine inlet and compressor inlet temperature on radiator area and thermal efficiency are discussed. For a He-Xe closed Brayton cycle, radiator areas as low as 650 m2/MWe are shown, with corresponding thermal efficiences at roughly 20% for the minimal radiator area solutions.

Brayton↗

Small Closed Brayton Cycle Engines for Space Applications

The presentation summarizes 60 years of closed Brayton cycle development and testing at Glenn Research Center and the many different space power applications for small Brayton cycle engines that have been studied over the years.

Rankine↗

Technology of nuclear-Brayton space power systems

The present technology of Brayton power systems is reviewed. The potential for even higher system efficiency at the 10 KWe level is assessed as well as the potential for comparable efficiency with an output of 1 or 2 KWe. Systems accommodation of isotope decay is briefly discussed. The salient features are described for a Brayton power system based on this technology and employing the ZrH reactor. Reactor lives for this and competitive systems are compared. Growth capability with an advanced reactor is assessed. A concept for application of this technology to driving a gas-dynamic laser is described.

English, R. E.↗

Steady-state temperature distribution within a Brayton rotating unit operating in a power conversion system using helium-xenon gas

The Brayton rotating unit (BRU), consisting of a turbine, an alternator, and a compressor, was tested as part of a Brayton cycle power conversion system over a side range of steady state operating conditions. The working fluid in the system was a mixture of helium-xenon gases. Turbine inlet temperature was varied from 1200 to 1600 F, compressor inlet temperature from 60 to 120 F, compressor discharge pressure from 20 to 45 psia, rotative speed from 32 400 to 39 600 rpm, and alternator liquid-coolant flow rate from 0.01 to 0.27 pound per second. Test results indicated that the BRU internal temperatures were highly sensitive to alternator coolant flow below the design value of 0.12 pound per second but much less so at higher values. The armature winding temperature was not influenced significantly by turbine inlet temperature, but was sensitive, up to 20 F per kVA alternator output, to varying alternator output. When only the rotational speed was changed (+ or - 10% of rated value), the BRU internal temperatures varied directly with the speed.

Johnsen, R. L.↗

Brayton heat exchange unit development program

A Brayton Heat Exchanger Unit (BHXU), consisting of a recuperator, a heat sink heat exchanger and a gas ducting system, was designed, fabricated, and tested. The design was formulated to provide a high performance unit suitable for use in a long-life Brayton-cycle powerplant. A parametric analysis and design study was performed to establish the optimum component configurations to achieve low weight and size and high reliability, while meeting the requirements of high effectiveness and low pressure drop. Layout studies and detailed mechanical and structural design were performed to obtain a flight-type packaging arrangement. Evaluation testing was conducted from which it is estimated that near-design performance can be expected with the use of He-Xe as the working fluid.

Morse, C. J.↗

Design and fabrication of the Brayton rotating unit

The Brayton rotating unit (BRU), operating on a gas bearing system, has been designed, fabricated, and demonstrated for use in a closed Brayton cycle space power conversion system. The BRU uses a binary mixture of xenon and helium (molecular weight, 83.8) as the cycle working fluid and bearing lubricating medium and was designed to produce from 2.25 to 10.5 kw sub e of 1200 Hz three-phase electrical power. The single-shaft rotating assembly operates at a design speed of 36,000 rpm and comprises a radial single-stage compressor, a four-pole Rice alternator rotor, and a radial inflow turbine. Four units, a dynamic simulator and three component research packages, were supplied to the NASA Lewis Research Center for performance testing and further development.

Davis, J. E.↗

Parallel operation of two Brayton-cycle alternators with parasitic speed controllers

The experimental paralleling characteristics of two 1200 Hz Brayton-cycle alternators are presented. Since the Brayton power conversion system uses electric speed controllers, the paralleling requirements are somewhat different from those for conventional ground-based systems. Results include the transient effects of synchronizing the two alternators with various phase-angle, voltage, and frequency differences. Based on these results, the effects of synchronizing differences can be defined, and adjustment requirements of the parasitic speed controllers during synchronizing can be established. Data indicate that parasitically loaded alternators are able to parallel over a wide range of synchronizing differences. However, equilibrium could not be reached in extreme cases where alternator load differences were great and, at the same time, the phase-angle error was large (150 deg or more).

Perz, D. A.↗

Concepts for application of 500- to 2500-We Brayton power systems for shuttle-launched missions

A mini-Brayton power system in the power range of 500 to 2500 We utilizing the multihundred Watt isotope heat source was studied for use in shuttle-launched experiments. The system consists of a single closed gas loop containing a single-shaft, gas cooled, compressor-alternator turbine assembly; a heat source heat exchanger assembly; a startup battery package; an electrical control module; a recuperator; a gas radiator; and a multifoil superinsulation system. The basic configuration and major nuclear payloads for shuttle integration are discussed. It is concluded that mini-Brayton systems have low isotope inventories and high electrical output per thermal input, and have the capability of flying all earth orbital and interplanetary missions with little degradation in performance.

Block, H. B.↗

Gas-injection-start and shutdown characteristics of a 2-kilowatt to 15-kilowatt Brayton power system

Two methods of starting the Brayton power system have been considered: (1) using the alternator as a motor to spin the Brayton rotating unit (BRU), and (2) spinning the BRU by forced gas injection. The first method requires the use of an auxiliary electrical power source. An alternating voltage is applied to the terminals of the alternator to drive it as an induction motor. Only gas-injection starts are discussed in this report. The gas-injection starting method requires high-pressure gas storage and valves to route the gas flow to provide correct BRU rotation. An analog computer simulation was used to size hardware and to determine safe start and shutdown procedures. The simulation was also used to define the range of conditions for successful startups. Experimental data were also obtained under various test conditions. These data verify the validity of the start and shutdown procedures.

Cantoni, D. A.↗

Recent technology advances in the NASA-Lewis Research Center Brayton program

A review of the progress and milestones passed in the Brayton program is presented. The 2-to-15 kWe power system was successfully operated in a vacuum with a space-type radiator. Gas loop and electrical subsystem endurance tests have continued to demonstrate long-term operation with one rotating unit surpassing 10,000 hours of failure-free operation. Simplified gas-bearing designs for the rotating unit are being evaluated. Fabrication of an improved design of heat exchanger is nearing completion, and a study of more advanced heat exchanger technology is being conducted. A study was completed to investigate the applicability of Brayton technology applied to a lower power level (0.5 to 2.5 kWe) and showed potentially very attractive performance, simplicity, and low cost for a system in this power range.

Vernon, R.↗

Technology of nuclear-Brayton space power systems.

The present technology of Brayton power systems is reviewed. The potential for even higher system efficiency at the 10 kWe level is assessed as well as the potential for comparable efficiency with an output of 1 or 2 kWe. System accommodation of isotope decay is briefly discussed. The salient features are described for a Brayton power system based on this technology and employing the ZrH reactor. Reactor lives for this and competitive systems are compared. Growth capability with an advanced reactor is assessed. A concept for application of this technology to driving a gas-dynamic laser is described.

English, R. E.↗

Brayton cycle heat exchanger and duct assembly (HXDA, preliminary design and technology tests

A preliminary design of the heat exchanger and duct assembly (HXDA) for a 60 kwe, closed loop, Brayton cycle space power system is presented. This system is weight optimized within the constraints imposed by the defined structural and operational requirements. Also presented are the results of several small scale tests, directed to obtaining specific design data and/or the resolution of a design approach for long life Brayton cycle heat exchanger systems.

Coombs, M. G.↗

Design, fabrication, and performance of foil journal bearing for the brayton rotating unit

Foil bearings were designed and manufactured to replace pivoted-shoe journal bearings in an existing Brayton Cycle turbo-alternator-compressor. The design of this unconventional rotor support was accomplished within the constraints and space limitations imposed by the present machine, and the substitution of foil bearings was effected without changes or modification other machine components. A housing and a test rig were constructed to incorporate the new foil-bearing support into a unified assemble with an air-driven rotor and the gimbal-mounted thrust bearing, seals, and shrouds of an actual Brayton Rotating Unit. The foil bearing required no external pressure source, and stable self-acting rotation was achieved at all speeds up to 43,200 rpm. Excellent wipe-wear characteristics of the foil bearing permitted well over 1000 start-stop cycles with no deterioriation of performance in the entire speed range.

Licht, L.↗

Parallel operation of two Brayton-cycle alternators with parasitic speed controllers.

The experimental paralleling characteristics of two 1200-Hz Brayton-cycle alternators are presented. Since the Brayton power conversion system uses electric speed controllers, the paralleling requirements are somewhat different from those for conventional ground-based power systems. Results include the transient effects of synchronizing the two alternators with various phase-angle, voltage, and frequency differences. Based on these results, the effects of synchronizing differences can be defined, and adjustment requirements of the parasitic speed controllers during synchronizing can be established. Data indicate that parasitically loaded alternators are able to parallel over a wide range of synchronizing differences.

Perz, D. A.↗