Search NASA⌕ Search

SEARCH · Search NASA

Results for “Building Heating Load”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 55 records · Page 3

System Design Techniques for Reducing the Power Requirements of Advanced life Support Systems

The high power requirement associated with overall operation of regenerative life support systems is a critical Z:p technological challenge. Optimization of individual processors alone will not be sufficient to produce an optimized system. System studies must be used in order to improve the overall efficiency of life support systems. Current research efforts at NASA Ames Research Center are aimed at developing approaches for reducing system power and energy usage in advanced life support systems. System energy integration and energy reuse techniques are being applied to advanced life support, in addition to advanced control methods for efficient distribution of power and thermal resources. An overview of current results of this work will be presented. The development of integrated system designs that reuse waste heat from sources such as crop lighting and solid waste processing systems will reduce overall power and cooling requirements. Using an energy integration technique known as Pinch analysis, system heat exchange designs are being developed that match hot and cold streams according to specific design principles. For various designs, the potential savings for power, heating and cooling are being identified and quantified. The use of state-of-the-art control methods for distribution of resources, such as system cooling water or electrical power, will also reduce overall power and cooling requirements. Control algorithms are being developed which dynamically adjust the use of system resources by the various subsystems and components in order to achieve an overall goal, such as smoothing of power usage and/or heat rejection profiles, while maintaining adequate reserves of food, water, oxygen, and other consumables, and preventing excessive build-up of waste materials. Reductions in the peak loading of the power and thermal systems will lead to lower overall requirements. Computer simulation models are being used to test various control system designs.

Finn, Cory↗

Host turbine heat transfer overview

Improved methods of predicting airfoil local metal temperatures require advances in the understanding of the physics and methods of analytically predicting the following four aerothermal loads: hot gas flow over airfoils, heat transfer rates on the gas-side of airfoils, cooling air flow inside airfoils, and heat transfer rates on the coolant-side of airfoils. A systematic building block research approach is being pursued to investigate these four areas of concern from both the experimental and analytical sides. Experimental approaches being pursued start with fundamental experiments using simple shapes and flat plates in wind tunnels, progress to more realistic cold and hot cascade tests using airfoils, continue to progress in large low-speed rigs and turbines and warm turbines, and finally, combine all the interactive effects in tests using real engines or real engine type turbine rigs. Analytical approaches being pursued also build from relatively simple steady two dimensional inviscid flow and boundary layer heat transfer codes to more advanced steady two and three dimensional viscous flow and heat transfer codes. These advanced codes provide more physics to model better the interactive effects and the true real-engine environment.

Rohde, J. E.↗

SINDA/FLUINT and Thermal Desktop Multi-Node Settled and Unsettled Propellant Tank Modeling of Zero Boil Off Test

Cryogenic propellant storage tank self-pressurization involves complex physical phenomena which are usually analytically modelled via complex multidimensional CFD (Computational Fluid Dynamics) codes. Unfortunately these codes, even when modelling axisymmetric domains, may take weeks or longer to obtain transient pressure and temperature information for relatively short periods of time (several seconds to several hours). Propellant tank storage end-to-end mission simulations can last a duration of days to weeks to months. Multi-node modelling of propellant tanks is a viable alternative to traditional CFD modelling and presents the advantage of greatly reduced run times on the order of hours and days compared to the weeks or longer for CFD codes. A multi-node model represents the fluid within the storage tank, as well as the storage tank itself, as a fluid-thermal network. This type of setup is not necessarily geometrically based. This can be accomplished using a commercial generalized fluid-thermal network code, such as SINDA/FLUINT (SF). The advantage of using a fluid-thermal network code like SF lies in its extensive ability to model the external environment of the storage tank through the graphical user interface, Thermal Desktop (TD). The total heat load into the tank may be a function of heaters and a complex radiative environment as well. Thermal Desktop may be used to address the detailed radiative environment of the tank as well as building a geometrically accurate depiction of the storage tank itself.

Thermal Desktop↗

SINDA/FLUINT and Thermal Desktop Multi-Node Settled and Unsettled Propellant Tank Modeling of Zero Boil Off Test

Cryogenic propellant storage tank self-pressurization involves complex physical phenomena which are usually analytically modelled via complex multidimensional CFD codes. Unfortunately these codes, even when modelling axisymmetric domains, may takes weeks or longer to obtain transient pressure and temperature information for relatively short periods of time (several seconds to several hours). Propellant tank storage end-to-end mission simulations can last a duration of days to weeks to months. Multi-node modelling of propellant tanks is a viable alternative to traditional CFD modelling and presents the advantage of greatly reduced run times on the order of hours and days compared to the weeks or longer for CFD codes. A multi-node model represents the fluid within the storage tank, as well as the storage tank itself, as a fluid-thermal network. This type of setup is not necessarily geometrically based. This can be accomplished using a commercial generalized fluid-thermal network code, such as SINDA/FLUINT (SF). The advantage of using a fluid-thermal network code like SF lies in its extensive ability to model the external environment of the storage tank through the graphical user interface, Thermal Desktop (TD). The total heat load into the tank may be a function of heaters and a complex radiative environment as well. Thermal Desktop may be used to address the detailed radiative environment of the tank as well as building a geometrically accurate depiction of the storage tank itself.

Sakowski, Barbara↗

Test and evaluation of Fern Engineering Company, Incorporated, solar heating and hot water system

Tests, test results, examination and evaluation by Underwriters Laboratory, Inc., of a single family solar heating and hot water system consisting of collector, storage, control, transport, and data acquisition are presented. The structural characteristics of the solar flat plate collectors were evaluated according to snow and wind loads indicated in various building codes to determine their suitability for use both Michigan and Pennsylvania where prototype systems were installed. The flame spread classification of the thermal insulation is discussed and the fire tests conducted on components are described. The operation and dielectrics withstand tests of the energy transport module indicate the module is capable of rated air delivery. Tests of the control panel indicate the relay coil temperatures exceed the temperature limits allowed for the insulating materials involved.

Source record↗

Solar heating system at Quitman County Bank, Marks, Mississippi

Information on the Solar Energy Heating System installed in a single story wood frame, cedar exterior, sloped roof building is presented. The system has on-site temperature and power measurements readouts. The 468 square feet of Solaron air flat plate collectors provide for 2,000 square feet of space heating, an estimated 60 percent of the heating load. Solar heated air is distributed to the 235 cubic foot rock storage box or to the load (space heating) by a 960 cubic feet per minute air handler unit. A 7.5 ton Carrier air-to-air heat pump with 15 kilowatts of electric booster strips serve as a back-up (auxiliary) to the solar system. Motorized dampers control the direction of airflow and back draft dampers prevent thermal siphoning of conditioned air.

Source record↗

Human Thermal Assessment of Traverse and Geology Task Iterations During Simulated Lunar Extravehicular Activity

Spacewalks or extravehicular activities (EVA) in microgravity are mentally and physically demanding. Current microgravity EVAs are predominantly focused on upper body tasks on engineered surfaces; however, the introduction of gravity means that crew members during future lunar EVAs will be required to perform tasks that generate full body workloads such as navigating natural lunar terrain while conducting geological sampling. To date, only 12 people have walked on the surface of the Moon resulting in limited knowledge of suited thermal regulation under lunar-relevant physical workloads. To address this gap, a study is underway to focus on spacesuit operations with simulated lunar EVA workloads. This study presents methodology for collecting standard thermal measures during suit testing. In this pilot study, two suited subjects underwent simulated lunar EVAs using the NASA Active Response Gravity Offload System (ARGOS) to simulate the effects of partial gravity. Each lunar EVA, lasting three to five hours, included various metabolically demanding EVA tasks. Subjects donned the NASA Mark III (MK III) space suit and were offloaded to 1/6th G (lunar gravity). A subset task circuit from one of these simulations replicated an EVA traverse to a lunar crater, taking a geological sample, and returning to base. The suited subject walked one 1500 m (0% grade) and three 500 m traverses at three different grades (10, 20, 30%). Between each traverse, subjects performed geology sampling tasks (0 and 10% grade). Thermal measurements included core and skin temperature, liquid cooling garment (LCG) inlet and outlet temperature, and spacesuit gas inlet and outlet temperature and humidity. Compared to baseline core temperature (S1 = 37.07±0.32 °C, S2 = 37.27±0.01 °C) and mean skin temperature (S1 = 32.38±0.34 °C, S2 = 33.62±0.03 °C), after a 1500 m traverse, each suited subject showed an increased core temperature (S1 = 37.23±0.12 °C, S2 = 37.41±0.11°C) and decreased mean skin temperature (S1 = 32.16±0.17 °C, S2 = 31.53±1.15 °C) at a delta LCG temperature (S1 = 1.86±0.24 °C, S2 = 2.20±0.76 °C) and delta suit humidity (S1 = 9.66±1.49 %, S2 = 11.50±1.58 %). Core temperature continued to increase from compounding traverse and geology tasks (S1 = 38.04±0.03 °C, S2 = 38.1±0.02 °C) accompanied by an increase in delta LCG temperature (S1 = 2.24±0.13 °C, S2 = 2.67±0.12 °C) and delta suit humidity (S1 = 28±2.42 %, S2 = 31±2.13 %). Conversely, as the circuit progressed, mean skin temperature continued to decrease due to sustained LCG heat rejection (S1 = 30.08±0.15 °C, S2 = 30.28±0.07 °C). During the simulated EVA circuit core temperature increased to elevated values and remained elevated as heat was retained while mean skin temperature decreased due to peripheral heat offloaded to the LCG. The thermal measures collected during this study provided critical heat loading dynamics during lunar EVA tasks. Including core and skin temperatures along with suited thermal measures provides a standard data collection scheme for human thermal metrics during EVA task management. Data collected in this configuration can be used to build future lunar EVA task circuits and human thermal predictions.

Bradley Hoffmann↗

Solar energy system performance evaluation. Seasonal report for Wormser, Columbia, South Carolina

The Wormser Solar Energy System's operational performance from April 1979 through March 1980 was evaluated. The space heating subsystem met 42 percent of the measured space heating load and the hot water subsystem met 23 percent of the measured hot water demand. Net electrical energy savings were 4.36 million Btu's or 1277 kwh. Fossil energy savings will increase considerably if the uncontrolled solar energy input to the building is considered.

Source record↗

Design and Build of Reactor Simulator for Fission Surface Power Technology Demonstrator Unit

The Nuclear Systems Team at NASA Marshall Space Flight Center (MSFC) focuses on technology development for state of the art capability in non-nuclear testing of nuclear system and Space Nuclear Power for fission reactor systems for lunar and Mars surface power generation as well as radioisotope power systems for both spacecraft and surface applications. Currently being designed and developed is a reactor simulator (RxSim) for incorporation into the Technology Demonstrator Unit (TDU) for the Fission Surface Power System (FSPS) Program, which is supported by multiple national laboratories and NASA centers. The ultimate purpose of the RxSim is to provide heated NaK to a pair of Stirling engines in the TDU. The RxSim includes many different systems, components, and instrumentation that have been developed at MSFC while working with pumped NaK systems and in partnership with the national laboratories and NASA centers. The main components of the RxSim are a core, a pump, a heat exchanger (to mimic the thermal load of the Stirling engines), and a flow meter for tests at MSFC. When tested at NASA Glenn Research Center (GRC) the heat exchanger will be replaced with a Stirling power conversion engine. Additional components include storage reservoirs, expansion volumes, overflow catch tanks, safety and support hardware, instrumentation (temperature, pressure, flow) for data collection, and power supplies. This paper will discuss the design and current build status of the RxSim for delivery to GRC in early 2012.

Godfroy, Thomas↗

Blood Pump Bearing System

Methods and apparatus are provided for a blood pump bearing system within a pump housing to support long-term high-speed rotation of a rotor with an impeller blade having a plurality of individual magnets disposed thereon to provide a small radial air gap between the magnets and a stator of less than 0.025 inches. The bearing system may be mounted within a flow straightener, diffuser, or other pump element to support the shaft of a pump rotor. The bearing system includes a zirconia shaft having a radiused end. The radiused end has a first radius selected to be about three times greater than the radius of the zirconia shaft. The radiused end of the zirconia shaft engages a flat sapphire endstone. Due to the relative hardness of these materials a flat is quickly produced during break-in on the zirconia radiused end of precisely the size necessary to support thrust loads whereupon wear substantially ceases. Due to the selection of the first radius, the change in shaft end-play during pump break-in is limited to a total desired end-play of less than about 0.010 inches. Radial loads are supported by an olive hole ring jewel that makes near line contact around the circumference of the shaft to support high speed rotation with little friction. The width of olive hole ring jewel is small to allow heat to conduct through to thereby prevent heat build-up in the bearing. A void defined by the bearing elements may fill with blood that then coagulates within the void. The coagulated blood is then conformed to the shape of the bearing surfaces.

Aber, Gregory S.↗

Method for Providing a Jewel Bearing for Supporting a Pump Rotor Shaft

Methods for a blood pump bearing system within a pump housing to support long-term high-speed rotation of a rotor with an impeller blade having a plurality of individual magnets disposed thereon to provide a small radial air gap between the magnets and a stator of less than 0.025 inches. The bearing system may be mounted within a flow straightener, diffuser, or other pump element to support the shaft of a pump rotor. The bearing system includes a zirconia shaft having a radiused end. The radiused end has a first radius selected to be about three times greater than the radius of the zirconia shaft. The radiused end of the zirconia shaft engages a flat sapphire endstone. Due to the relative hardness of these materials a flat is quickly produced during break-in on the zirconia radiused end of precisely the size necessary to support thrust loads whereupon wear substantially ceases. Due to the selection of the first radius, the change in shaft end-play during pump break-in is limited to a total desired end-play of less than about 0.010 inches. Radial loads are supported by an olive hole ring jewel that makes near line contact around the circumference of the shaft to support high speed rotation with little friction. The width of olive hole ring jewel is small to allow heat to conduct through to thereby prevent heat build-up in the bearing. A void defined by the bearing elements may fill with blood that then coagulates within the void. The coagulated blood is then conformed to the shape of the bearing surfaces.

Gregory S Aber↗

The Energy Systems Optimization Computer Program /ESOP/ developed for Modular Integrated Utility Systems /MIUS/ analysis

A significant energy and cost savings can be obtained by integrating various utility services (space heating and cooling, electrical power generation, solid waste disposal, potable water, and waste water treatment) into a single unit which provides buildings or groups of buildings with these services. This paper presents a description of a computer program, called the Energy Systems Optimization Program (ESOP). This program predicts the loads, energy requirements, equipment sizes, and life-cycle costs of alternative methods of meeting these utility requirements. The program has been used extensively for performing energy analyses of Modular Integrated Utility Systems (MIUS).

Ferden, S. L.↗

Blood Pump Bearing System

An apparatus is provided for a blood pump bearing system within a pump housing to support long-term highspeed rotation of a rotor with an impeller blade having a plurality of individual magnets disposed thereon to provide a small radial air gap between the magnets and a stator of less than 0.025 inches. The bearing system may be mounted within a flow straightener, diffuser, or other pump element to support the shaft of a pump rotor. The bearing system includes a zirconia shaft having a radiused end. The radiused end has a first radius selected to be about three times greater than the radius of the zirconia shaft. The radiused end of the zirconia shaft engages a flat sapphire endstone. Due to the relative hardness of these materials a flat is quickly produced during break-in on the zirconia radiused end of precisely the size necessary to support thrust loads whereupon wear substantially ceases. Due to the selection of the first radius, the change in shaft end-play during pump break-in is limited to a total desired end-play of less than about 0.010 inches. Radial loads are supported by an olive hole ring jewel that makes near line contact around the circumference of the Ir shaft to support big speed rotation with little friction. The width of olive hole ring jewel is small to allow heat to conduct through to thereby prevent heat build-up in the bearing. A void defined by the bearing elements may fill with blood that then coagulates within the void. The coagulated blood is then conformed to the shape of the bearing surfaces.

Aber, Gregory S.↗

Development of flat-plate solar collectors for the heating and cooling of buildings: Executive summary

An efficient, low cost, flat-plate solar collector was developed. Computer aided mathematical models of the heat process in the collector were used in defining absorber panel configuration; determining insulation thickness; and in selecting the number, spacing, and material of the covers. Prototypes were built and performance tested. Data from simulated operation of the collector are compared with predicted loads from a number of locations to determine the degree of solar utilization.

Source record↗

Building application of solar energy. Study no. 4: Scenarios for the utilization of solar energy in southern California buildings, change 1

Plausible future market scenarios for solar heating and cooling systems into buildings in the area served by the Southern California Edison Company. A range of plausible estimates for the number of solar systems which might be installed and the electrical energy which might be displaced by energy from these systems are provided. The effect on peak electrical load was not explicitly calculated but preliminary conclusions concerning peak load can be inferred from the estimates presented. Two markets are investigated: the single family market and the large power commercial market.

Davis, E. S.↗

Design and Hardware Progress on a Magnetically-Geared Actuator for Extremely Cold Lunar Environments

Introduction: Under the Motors for Dusty and Extremely Cold Environments (MDECE) Project, NASA Glenn Research Center is developing a magnetically-geared actuator for extremely cold space environments to avoid the wiring and significant efficiency penalty associated with heating grease-lubricated actuators as well as the stringent life and loading constraints imposed by dry film lubricated mechanical gears. The heating penalty can be equivalent to up to a 90% efficiency reduction in permanently shadowed regions on the Moon. This poster or presentation will summarize the progress made over the past 6-12 months on designing the fully-functional actuator and building a proof-of-concept actuator and testing it in an ambient environment. Design Progress: A critical design review was successfully completed at the end of June 2023. This presentation will touch on the key highlights from that review in the areas of electro-magnetic design and optimization, bearing optimization, thermal analysis, structural analysis, and mechanical design and manufacturing. The predicted technical performance measures of the actuator will be mentioned. The team is currently finishing some actions from the review and finalizing the drawing package in preparation for hardware procurement. Hardware Progress: Despite some significant delays in receiving fabricated parts and magnetic subassemblies, progress was made in manufacturing and assembling a proof-of-concept version of both the actuator’s magnetically-geared motor (Fig. 1) and the actuator’s cycloidal-type output magnetic gear stage (Fig. 2) [3]. The presentation will mention key lessons learned to date from the fabrication, assembly, and testing of the proof of concept.

Lunar surface↗

Indigenous lunar construction materials

The utilization of local resources for the construction and operation of a lunar base can significantly reduce the cost of transporting materials and supplies from Earth. The feasibility of processing lunar regolith to form construction materials and structural components is investigated. A preliminary review of potential processing methods such as sintering, hot-pressing, liquification, and cast basalt techniques, was completed. The processing method proposed is a variation on the cast basalt technique. It involves liquification of the regolith at 1200-1300 C, casting the liquid into a form, and controlled cooling. While the process temperature is higher than that for sintering or hot-pressing (1000-1100 C), this method is expected to yield a true engineering material with low variability in properties, high strength, and the potential to form large structural components. A scenario for this processing method was integrated with a design for a representative lunar base structure and potential construction techniques. The lunar shelter design is for a modular, segmented, pressurized, hemispherical dome which could serve as habitation and laboratory space. Based on this design, estimates of requirements for power, processing equipment, and construction equipment were made. This proposed combination of material processing method, structural design, and support requirements will help to establish the feasibility of lunar base construction using indigenous materials. Future work will refine the steps of the processing method. Specific areas where more information is needed are: furnace characteristics in vacuum; heat transfer during liquification; viscosity, pouring and forming behavior of molten regolith; design of high temperature forms; heat transfer during cooling; recrystallization of basalt; and refinement of estimates of elastic moduli, compressive and tensile strength, thermal expansion coefficient, thermal conductivity, and heat capacity. The preliminary design of the lunar shelter showed us that joining is a critical technology needed for building a structure from large segments. The problem of joining is important to the design of any structure that is not completely prefabricated. It is especially important when the structure is subjected to tensile loading by an internal pressure. For a lunar shelter constructed from large segments the joints between these large segments must be strong, and they must permit automated construction. With a cast basalt building material which is brittle, there is the additional problem of connecting the joint with the material and avoiding stress concentration that would cause failure. Thus, a well-defined project which we intend to pursue during this coming year is the design of joints for cast basalt structural elements.

Rogers, Wayne P.↗

Solar hot water system installed at Las Vegas, Nevada

A solar energy hot water system installed in a motor inn at Las Vegas, Nevada is described. The inn is a three story building with a flat roof for installation of the solar panels. The system consists of 1,200 square feet of liquid flat plate collectors, a 2,500 gallon insulated vertical steel storage tank, two heat exchangers, and pumps and controls. The system was designed to supply approximately 74 percent of the total hot water load.

Source record↗