Maximum-impact Adversary Design for Network-based Control System: A Case Study on Grid-interactive Efficient Buildings

The Internet of Things (IoT) technology has dramatically improved the efficiency of today's building operation and management. By connecting controllable devices into a communication network, control signals can be easily passed to the devices, and operating status can be acquired from measurable ends with minimal effort. However, this all-connected configuration could also expose the network-based control system (NBCS) to malicious actions, such as cyberattacks. One of the common NBCSs is the building automation system. With the promotion of grid-interactive efficient buildings (GEBs), there has been increasing attention on securing the buildings from the network perspective. This research proposes a maximum-impact adversary design framework so that the adversary can provide the most adversarial impact on the controlled system while remaining stealthy. The proposed framework is numerically demonstrated on a network-based building energy and control system. The building energy system is built in a Modelica-based simulation environment and controlled by the state-of-the-art ASHRAE Guideline 36 control sequences. The control commands at the supervisory level, generated from the Guideline 36 controller, are assumed to be sent to local devices through communication networks using the BACnet protocol. Simulation results show that the proposed maximum-impact adversary on such a system can stealthily affect the building system's performance to its maximum extent. It is anticipated that results can be used by researchers and practitioners in the building automation industry to design efficient and robust cyber-attack detection algorithms, especially for stealthy attacks.

Chu, Mengyuan↗

Optimizing Facility Operations by Applying Machine Learning to the Army Reserve Enterprise Building Control System (Final Report)

Thousands of U.S. Department of Defense (DoD) buildings have building automation systems (BASs) and/or advanced meters. Although these systems have a wealth of data, performance optimization requires time and expertise to review and act on that information. Machine learning (ML) can provide automated and actionable insights to controls operators. This demonstration implemented proven ML methods on the Army Reserve Enterprise Building Control System. ML refers to algorithms that “learn” from data and improve their performance on a given task over time. In the buildings domain these tasks range from predicting future energy consumption, to identifying operational issues before faults occur, to optimizing control decisions. To learn, ML requires input data, which – for buildings – typically consists of instrument data such as energy consumption data and subsystem controls information such as set-point temperatures, and context data consisting of information such as the physical location of the building, the area of the building, and the weather. ML models use the relationships learned from the input data to make predictions with new, previously unseen, data. The team was able to investigate and successfully implement the following ML use cases: labeling consumption data as anomalous or non-anomalous; baseline whole-building load prediction (unknown fault status); fault detection (validation not possible); and site prioritization for energy-related projects. Due to the constraints of the project, interventions were not able to be implemented during the demonstration; therefore, assessments of operational cost savings and maintenance avoided could not be performed. The project has been presented at two leading national building conferences and two additional publications to peer-reviewed journals are currently in preparation.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Model predictive control of heating, ventilation, and air conditioning (HVAC) systems: A state-of-the-art review

Due to the fast advancement of communication and information technology, intelligent buildings have garnered great interest. These buildings can forecast weather, ambient temperature, and sun irradiation and can modify heating, ventilation, and air conditioning (HVAC) operations appropriately, based on current and previous data. This change is intended to reduce HVAC system energy usage while maintaining an appropriate degree of thermal comfort and indoor air quality. Since its inception, model predictive control (MPC) has been one of the prospective solutions for HVAC management systems to reduce both costs and energy usage. Additionally, MPC is becoming increasingly practical as the processing capacity of building automation systems increases and a large quantity of monitored building data becomes available. MPC also provides the potential to improve the energy efficiency of HVAC systems via its capacity to consider limitations, to predict disruptions, and to factor in multiple competing goals such as interior thermal comfort and building energy consumption. Although substantial research has been conducted on MPC in building HVAC systems, there is a shortage of critical reviews and a lack of a comprehensive framework that formulates and defines the applications. Here, this article provides a comprehensive state-of-the-art overview of MPC in HVAC systems. Detailed discussions of modeling approaches and optimization algorithms are included. Numerous design aspects such as prediction horizon, occupancy behavior, building type, and cost function, that impact MPC performance are discussed in detail. The technical characteristics, advantages, and disadvantages of various types of modeling software are discussed. The primary objective of this work is to highlight critical design characteristics for the MPC control scheme and to give improved suggestions for future research. Moreover, numerous prospective scenarios have been suggested that might provide future research direction.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Assessing the performance of global thermostat adjustment in commercial buildings for load shifting demand response

Abstract Efficiently leveraging new sources of flexibility is critical to mitigating load balancing challenges posed by variable renewable resources. The thermal inertia of commercial buildings allows us to shift their power consumption on minute to hourly timescales to provide demand response to the grid while maintaining occupant comfort. Global thermostat adjustment (GTA) provides a readily available and scalable approach for implementing load shifting demand response using commercial heating, ventilation, and air conditioning (HVAC) systems, since it leverages the inherent sophistication of modern building automation systems. However, there is an incomplete understanding of GTA’s performance for this purpose and its impact on building systems and occupant comfort. In this paper, we explore the performance of GTA by analyzing results from nearly nine hundred experiments on eight university campus buildings in Michigan and North Carolina. Using GTA, we manipulate each building’s thermostat setpoints causing the building to shift its power consumption with respect to its baseline. We quantify the magnitude of HVAC power response, energy use of HVAC subsystems, and impact on occupant comfort. Finally, we connect our experimental results with power system operation using an optimization model that coordinates GTA actions across a large collection of grid-interactive efficient buildings (GEBs) to reduce high ramp rates on the grid and mitigate renewable energy curtailment. Overall, our work finds that the impacts on HVAC subsystems are often complex, and may result in additional energy being consumed by fans and terminal reheat. These effects must be considered when using GTA for load shifting. Additionally, we demonstrate that occupant comfort, as assessed by indoor temperature and humidity, can be maintained during GTA events. From a societal perspective, our modeling work finds that the additional renewable energy that can be integrated through the use of GTA strategies eclipses any additional energy consumed by buildings.

Keskar, Aditya (ORCID:0000000244617980)↗

Agency Recognized for Integrated Controls for HVAC and Lighting Systems - Case Study: Denver Water

This case study highlights the strategies Denver Water used at its Administration Building for integrating HVAC and lighting systems. They employed advanced lighting controls, integrated with building automation systems, as well as lighting system occupancy sensors integrated with HVAC controls. The project was recognized by DOE's Integrated Lighting Campaign.

integrated lighting, lighting, controls, HVAC, bui↗

Demonstration of a Novel Technology to Manage Electricity Demand in Grid-Independent Military Microgrids

This research was conducted by the National Renewable Energy Laboratory (NREL) in collaboration with the S&C Electric Inc. through funding provided by the ESTCP. The project demonstrates use of cybersecure Automated Demand Response (ADR) technology to effectively manage microgrid loads during grid-independent, also known as "islanded," operation. When military microgrids become isolated from the main electrical grid, they are required to balance electricity supply and demand locally. Given that local generation may be constrained, the prevailing strategy involves shedding all but the most critical loads by tripping smart circuit breakers, which then necessitate manual resetting. This approach is generally implemented at the building level, which means that the buildings with mission-critical activities are exempt from load management and remain fully powered, whereas those deemed non-critical can experience a complete loss of service. In this research we developed a method that allows building automation systems to selectively control their assets in response to load shedding request from a microgrid controller, avoiding total loss of service in contrast to the conventional control approach. A commercial OpenADR client server by GridFabric is used for communication between the microgrid controller and the building management system (BMS). The microgrid controller monitors both generation capacity and various assets within the microgrid and issues a demand reduction request when necessary. This request is communicated to the OpenADR server via Modbus. Upon receiving the request, the OpenADR server forwards it to the BMS utilizing the OpenADR protocol. The BMS is pre-configured with various levels of load reduction strategies based on the controllable assets available, allowing for a nuanced approach to demand reduction. Both lab and field tests were performed that considered load shedding needed to achieve closed transition into island mode and to accommodate changing loads and power source availability while islanded. A commercial microgrid controller was used for these tests with normal programming within the expected constraints of the system capabilities. That is, the solution did not require any specialized modification to the code base of the controller. Given the latency of the round-trip communication path between the microgrid controller and the various devices involved with the load shed processes, there are certain scenarios for which the demonstrated solution are appropriate and some which are not. The methods described in this report can be used for load shedding/restoration during transitions between islanded and grid-tied modes of operation, as well as accommodating normal variations in load and the need to remove a power source from operation for maintenance. These methods should not be used for scenarios that require load shedding within a second or two such as sudden and unanticipated significant load increases or loss of power sources through equipment faults.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Energy cost savings and expected payback for Re-tuning the controls of US Army buildings

The Headquarters Department of the Army (HQDA) sponsored a study to determine the national impact of deploying the Re-tuning™ methodology in 5 buildings types that account for over 40% of the Army’s conditioned building stock. Re-tuning is a systematic process that improves operational efficiency and reduces energy consumption at no- or low-cost through the building automation system (BAS) by correcting operational problems that plague buildings. The study relied on successful demonstration of the re-tuning methodology at 4 pilot US Army installations that informed a holistic effort that included simulating 12 individual re-tuning energy efficiency measures (EEMs) and 6 packages of EEMs in 5 selected Army building prototype models that represent 311 million ft2 (28.9 million m2) of the Army’s conditioned floor space. Both the baseline buildings and the packages were customized to capture the expected outcomes of re-tuning a diverse set of buildings. The study highlighted the benefit of individual re-tuning EEMs and economics of implementing packages of EEMs in applicable Army buildings across 16 climates and 2 building vintages. The average whole-building energy savings ranged from 10.8% to 40.5% by building type, with the company operations facility (COF) building having the highest value proposition from re-tuning. In addition, the study reveals that all large office (LO) buildings in the Army are economical to re-tune. The total modeled cost savings potential for re-tuning the five building types across the US Army is $204/1,000 sf ($220/100 m2), or $64M annually. This cost savings represents 5.6% of all the Army’s energy expenditures.

Fernandez, Nicholas EP↗

HP-FLEX: Field demonstration of the semantics-driven configuration of a Model Predictive Control system to make heat pumps flexible

Model Predictive Control (MPC) has demonstrated significant potential for optimizing building operations and enabling demand flexibility. However, the widespread adoption of MPC is hindered by complex manual configuration and commissioning processes that must be conducted by control experts working alongside building operators. These challenges drive up costs and reduce scalability, particularly when technical human resources and building automation systems are limited, such as in small and medium commercial buildings (SMCBs). This paper demonstrates how semantic standards, specifically ASHRAE 223P, can accelerate the adoption of MPC applications for load flexibility in SMCBs. The authors present a replicable control framework, titled “HP-FLEX” that leverages a building’s semantic model to bootstrap the required data configuration for an MPC controller developed for optimizing heat pump systems as flexible grid resources. The semantic model helps streamline the deployment workflow, particularly for site setup, data/control commissioning, and model setup. This integration enhances portability, transferability, and scalability of the HP-FLEX MPC, which has been developed to support MPC-based supervisory HVAC controllers in SMCBs. Additionally, the paper details the required building and thermostat metadata information to enable the HP-FLEX MPC based on field demonstrations. The new workflow was tested in a small commercial building located in California, U.S., and demonstrated a load shifting performance of 9% based on a dynamic pricing signal that varies by the hour. This work provides a practical pathway for transitioning sophisticated building applications from custom to standardized semantic representations, supporting the broader adoption of advanced control strategies like MPC. The framework also establishes a foundation for evolving metadata requirements as applications mature while maintaining compatibility with industry standards.

Paul, Lazlo↗

HP-FLEX: Field Demonstration of the Semantics-Driven Configuration of a Model Predictive Control System to Make Heat Pumps Flexible

Model Predictive Control (MPC) has demonstrated significant potential for optimizing building operations and enabling demand flexibility. However, the widespread adoption of MPC is hindered by complex manual configuration and commissioning processes that must be conducted by control experts working alongside building operators. These challenges drive up costs and reduce scalability, particularly when technical human resources and building automation systems are limited, such as in small and medium commercial buildings (SMCBs). This paper demonstrates how semantic standards, specifically ASHRAE 223P, can accelerate the adoption of MPC applications for load flexibility in SMCBs. The authors present a replicable control framework, titled “HP-FLEX” that leverages a building’s semantic model to bootstrap the required data configuration for an MPC controller developed for optimizing heat pump systems as flexible grid resources. The semantic model helps streamline the deployment workflow, particularly for site setup, data/control commissioning, and model setup. This integration enhances portability, transferability, and scalability of the HP-FLEX MPC, which has been developed to support MPC-based supervisory HVAC controllers in SMCBs. Additionally, the paper details the required building and thermostat metadata information to enable the HP-FLEX MPC based on field demonstrations. The new workflow was tested in a small commercial building located in California, U.S., and demonstrated a load shifting performance of 9% based on a dynamic pricing signal that varies by the hour. This work provides a practical pathway for transitioning sophisticated building applications from custom to standardized semantic representations, supporting the broader adoption of advanced control strategies like MPC. The framework also establishes a foundation for evolving metadata requirements as applications mature while maintaining compatibility with industry standards.

Paul, Lazlo↗

Seminar 44, Innovative and New Ideas: BAS Best Practices for O&M Success Coaching Operators for Effective Use of Data

Regardless of a building’s inherent energy efficiency, changes in building operator behavior reduces building energy consumption by 14% on average. Giving operators readily available and easily digestible data regarding the performance of their HVAC systems increases the likelihood of energy saving actions. Many Building Automations Systems do not excel at creating user-friendly time series trend charts. This presentation presents examples of a solution to this issue developed under an award by the Department of Energy.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Implementation and test of an automated control hunting fault correction algorithm in a fault detection and diagnostics tool

Control hunting due to improper proportional–integral–derivative (PID) parameters in the building automation system (BAS) is one of the most common faults identified in commercial buildings. It can cause suboptimal performance and early failure of heating, ventilation, and air conditioning (HVAC) equipment. Commercial fault detection and diagnostics (FDD) software represents one of the fastest growing market segments in smart building technologies in the United States. Implementation of PID retuning procedures as an auto-correction algorithm and integration into FDD software has the potential to mitigate control hunting across a heterogeneous portfolio of buildings with different BAS in a scalable way. This paper presents the development, implementation, and field testing of an automated control hunting fault correction algorithm based on lambda tuning open-loop rules. The algorithm was developed in a commercial FDD software and successfully tested among nine variable air volume boxes in an office building in the United States. The paper shows the feasibility of using FDD tools to automatically correct control hunting faults, discusses scalability considerations, and proposes a path forward for the HVAC industry and academia to further improve this technology.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Virtual Metering for Monitoring Building Energy Consumption

The United States Department of Energy (DOE) has standard metering requirements of commercial buildings for optimizing energy performance. The guiding principles are to continuously track and optimize energy performance and install building-level meters for electricity, natural gas, and steam. Some buildings at Los Alamos National Laboratory (LANL) have physical submeters monitoring their energy consumption, but these meters have proven to be unreliable. And, in most cases, replacing them has proven to be a slow process. Installing new submeters also requires a temporary lockout of the circuit on which they are being installed. Many buildings at LANL contain laboratories with ongoing experiments or data centers, which makes an equipment power outage nearly impossible to plan. This inability to plan power outages results in long-term submeter failures. Although most submeters are eventually replaced, failures lead to missing consumption data for some unpredictable, extended time. A building automation system (BAS) is a system that provides control and monitoring on a building to maintain the operational performance of the building and occupancy comfort. Many buildings at LANL currently have a BAS, and all new renovations and installs will include installing a BAS if one does not already exist. The intended purpose for a BAS is primarily to monitor the health and efficiency of a building; however, it is also possible to calculate equipment power and energy consumption using BAS information. This project aims to use virtual meters to monitor building energy consumption as a cost-effective and minimally labor-intensive alternative to installing physical submeters. The fault detection and diagnostics tool, SkySpark, provides a centralized database for all the data from the various BAS that are active at LANL. This data includes the information that is needed to create virtual meters for heating, ventilating, and air conditioning (HVAC) systems in most buildings, including heating and cooling loads. 9 This report begins with a detailed summary of the project, including the reasoning, procedure, and results. The specific processes of creating the various virtual meters are then identified. Then the limitations are discussed. And, lastly, the results and future potential are presented.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

A review of machine learning in building load prediction

The surge of machine learning in recent years has been empowering engineer modeling in various fields. The decreasing hardware cost, increasing data accessibility, and advances of building automation system (BAS) allow the collection and storage of a significant amount of building operation data. The two facts provide great opportunities of applying machine learning to building energy systems modeling and analysis. There are a great number of research papers on this topic but there lacks a comprehensive and general review to summarize the current development, limitations, gaps and future trend. In this review paper series, machine learning techniques in building energy system modeling and analysis are reviewed under the organization and logic of the machine learning definition by Tom M. Mitchell: a computer program is said to learn from experience E with respect to some class of tasks T and performance measure P if its performance at tasks in T, as measured by P, improves with experience E. This paper is the first part of the review paper series, which focuses on building load prediction. First, the applications of building load prediction model (task T) are reviewed. Then, the modeling algorithms improving machine learning performance and accuracy (performance P) are reviewed. At the same time, the literature on the data perspective for modeling (experience E), including data engineering from sensors level to data level, pre-processing, feature extraction and selection, is reviewed. Finally, what is well-studied and what is lacking but with great potential are concluded; the gaps between present and future utilization of machine learning techniques are identified; the future trend and development are also predicted. The target readers of this paper are not only researchers from the building side who can get exposed to cutting edge machine learning tools, but also those from machine learning side who can understand the potential and challenge to apply machine learning in buildings.

Liang, Zhang↗

Sensor cost-effectiveness analysis for data-driven fault detection and diagnostics in commercial buildings

Data-driven building fault detection and diagnostics (FDD) is heavily dependent on sensors. However, common sensors from Building Automation Systems are not optimized to maximize accuracy in FDD. Installing additional sensors that provide more detailed building system information is key to maximizing the performance of FDD solutions. Here in this paper, we present a sensor cost analysis workflow to quantify the economic implications of installing new sensors for FDD using the concept of sensor threshold marginal cost (STMC). STMC does not represent actual sensor cost. Rather, it represents a target cost based on the economic benefit that would be realized through improved FDD performance and one or more specified economic criteria. We calculate STMCs for multiple possible fault types and use fault prevalence information to aggregate STMCs into a single dollar value to determine the cost-effectiveness of a potential sensor investment. We conducted a case study using Oak Ridge National Laboratory's Flexible Research Platform (FRP) test facility as a reference. The case study demonstrates the feasibility of the analysis and highlights the key cost considerations in sensor selection for FDD. The results also indicate that identifying and installing the few key sensor(s) is critical to cost-effectively improve FDD performance.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Continuous thermostat setpoint monitoring and correction (Thermostat setpoint correction) v1.0

The Continuous Thermostat Setpoint Monitoring and Correction software is a set of fault detection and correction algorithms that can be implemented in thermostats with two-way OpenAPIs. It is written in the Python language. The algorithms aim to detect the most common and impactful efficiency problems associated with thermostat setpoints - overly aggressive heating or cooling setpoints, incorrect schedules/setbacks, and overly narrow deadbands. These algorithms can automatically detect faults, and implement associated corrective actions to bring the system back to a state of efficient operation. The algorithms can run remotely in the cloud, and directly implemented by connected thermostat manufacturers, or by third party service providers. The software enables a lightweight cost-effective energy management strategy for HVAC systems. The solution is specially viable for small and medium sized commercial buildings, where a full scale building automation system and fault detection and diagnostic tools are often unavailable.

Granderson, Jessica↗

An open control sequence specification to scale building demand flexibility via analytics software

For over two decades, researchers and practitioners have showcased the ability of large commercial buildings to provide grid services by shedding or shifting load. Various utility demand response (DR) and virtual power plant (VPP) programs throughout the United States are presently utilizing these demand-side resources. However, growth of these programs have been limited, in part due to the high cost necessary to integrate the DR control strategies into the building automation system (BAS). Implementing these strategies involves adjusting control sequences, necessitating dozens of hours of customized programming per building, limiting their adoption to large organizations and progressive owners. Recent efforts by researchers and industry have demonstrated the capability of energy management and information systems (EMIS), originally designed for fault detection and diagnostics, to interface with existing BAS and perform supervisory control to optimize building operations. While these approaches are quickly being adopted by industry, demand flexibility (DF) control strategies remain limited in product offerings. One of the challenges is the lack of documented best-practice DF sequences, despite the rich literature on field implementations. This paper develops a new open-specification for a zone-based temperature adjustment shed strategy for commercial building HVAC systems, describing the specification’s implementation in two EMIS tools in both experimental and field settings. Both implementations successfully reduced electric load by at least 40% on average during the called event, while maintaining temperature limits. This study’s detailed process from specification to deployment shows the potential for scalability as well as highlights challenges related to integration with heterogeneous BAS products.

Granderson, Jessica↗

A cosine-based correlation information entropy approach for building automatic fault detection baseline construction

Building automatic fault detection and diagnosis (AFDD) technologies have shown great potential for energy savings. To enable AFDD, a baseline depicting the normal operation mode is needed to detect whether the building operation deviates from normality. Existing research using physics-based knowledge and models for AFDD has mainly taken a trial-and-error approach to determine if a given baseline is sufficient via empirical experiments. A mechanism to support decisions such as how many samples and what samples should be included in the baseline is currently lacking. In this study, a data-driven method for AFDD baseline construction based on information entropy is developed. The entropy is derived based on cosine similarity among typical building automation system measurements in conjunction with outdoor weather information. The performance of the proposed method is evaluated using real building data. Evaluation results indicate that the fault detection strategy adopting the proposed method has similar or better accuracy in detecting faults compared to the same fault detection strategy using the baseline construction method from the literature. Additionally, the use of entropy enables the proposed method to automatically construct and assess the baseline consisting of information-rich samples.