Search NASA⌕ Search

SEARCH · Search NASA

Results for “Building benchmarking models”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 55 records · Page 3

Intercomparison of flood inundation models across land use types and hydrological flood stages

Flood Inundation Mapping (FIM) model selection is a key operational decision because accurate, rapid mapping underpins early warning and resource allocation. FIM performance is context-dependent and can vary with hydrograph phase, land-use/land-cover (LULC), and the evaluation benchmark. Intercomparison studies typically assess a single near-peak snapshot against one reference dataset. Here, we provide a context-stratified intercomparison across (i) multiple hydrograph phases, (ii) LULC classes, and (iii) benchmark types, for five FIM approaches spanning a wide range of physical complexity and operational cost (TRITON, LISFLOOD-FP, HEC-RAS 2D, ARC-Curve2Flood, and OWP HAND-FIM). We use the Hurricane Matthew flood (2016) in the Neuse River Basin, North Carolina, USA, as a case study. Using high-resolution remote sensing-derived flood inundation maps, hand-labeled points, and building footprints, we assess model skill across two rising and two falling hydrograph limbs and across major LULC types. Results show that model rankings shift systematically across contexts: LISFLOOD-FP ranks highest in three of four flood phases, while TRITON leads during one rising limb phase; LISFLOOD-FP performs best in vegetated areas, whereas HEC-RAS improves relative performance in agricultural and urban areas; and benchmark choice influences conclusions, with LISFLOOD-FP performing best for flooded-building detection in the late falling limb, while TRITON ranks highest against hand-labeled points. We also report representative wall-clock runtimes for each workflow to provide use-case context for operational feasibility. Together, these results offer transferable guidance for model selection and for designing large-scale, benchmark-aware FIM intercomparison studies.

Nikrou, Parvaneh [University of Alabama]↗

AI Benchmark Democratization and Carpentry

Benchmarks are a cornerstone of modern machine learning, enabling reproducibility, comparison, and scientific progress. However, AI benchmarks are increasingly complex, requiring dynamic, AI-focused workflows. Rapid evolution in model architectures, scale, datasets, and deployment contexts makes evaluation a moving target. Large language models often memorize static benchmarks, causing a gap between benchmark results and real-world performance. Beyond traditional static benchmarks, continuous adaptive benchmarking frameworks are needed to align scientific assessment with deployment risks. This calls for skills and education in AI Benchmark Carpentry. From our experience with MLCommons, educational initiatives, and programs like the DOE's Trillion Parameter Consortium, key barriers include high resource demands, limited access to specialized hardware, lack of benchmark design expertise, and uncertainty in relating results to application domains. Current benchmarks often emphasize peak performance on top-tier hardware, offering limited guidance for diverse, real-world scenarios. Benchmarking must become dynamic, incorporating evolving models, updated data, and heterogeneous platforms while maintaining transparency, reproducibility, and interpretability. Democratization requires both technical innovation and systematic education across levels, building sustained expertise in benchmark design and use. Benchmarks should support application-relevant comparisons, enabling informed, context-sensitive decisions. Dynamic, inclusive benchmarking will ensure evaluation keeps pace with AI evolution and supports responsible, reproducible, and accessible AI deployment. Community efforts can provide a foundation for AI Benchmark Carpentry.

von Laszewski, Gregor [Virginia U.]↗

The good, the bad, and the ugly: Data-driven load profile discord identification in a large building portfolio

Reducing the overall energy consumption and associated greenhouse gas emissions in the building sector is essential for meeting our future sustainability goals. Recently, smart energy metering facilities have been deployed to enable monitoring of energy consumption data with hourly or subhourly temporal resolution. This unprecedented data collection has created various opportunities for advanced data analytics involving load profiles (e.g., building energy benchmarking programs, building-to-grid integration, and calibration of urban-scale energy models). These applications often need preprocessing steps to detect daily load profile discords, such as: 1) outliers due to system malfunctions (the bad) and 2) irregular energy consumption patterns, such as those resulting from holidays (the ugly) compared to normal consumption patterns (the good). However, current preprocessing methods predominantly focus on filtering using statistical threshold values, which fail to capture the contextual discords of daily profiles. In addition, discord detection algorithms in building research are often aimed at finding individual building-level discords, which are not suitable at a large scale. Thus, here, we develop a method for automated load profile discord identification (ALDI) in a large portfolio of buildings (more than 100 buildings). Specifically, ALDI 1) uses the matrix profile (MP) method to quantify the similarities of daily subsequences in time series meter data, 2) compares daily MP values with typical-day MP distributions using the Kolmogorov-Smirnov test, and 3) identifies daily load profile discords in a large building portfolio. We evaluate ALDI using the metering data of both an academic campus and a residential neighborhood. Our results demonstrate that ALDI efficiently discovers measurement errors by system malfunctions and low energy consumption days in the academic campus portfolio, and it detects unique load shape patterns likely driven by occupant behavior and extreme weather conditions in the residential neighborhood.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Validation of MCNP Critical Benchmark Models of Moderated Highly Enriched Uranium Slabs

A new centralized repository of high-quality MCNP models of critical benchmark experiments is currently under development at Los Alamos National Laboratory (LANL). The benchmark experiments are described in the International Criticality Safety Benchmark Evaluation Project (ICSBEP) Handbook, and the initial set of benchmark models are derived from the Whisper Suite provided with MCNP6.2. This effort is a collaboration among the Nuclear Criticality Safety, Nuclear Data, and Monte Carlo code development/application organizations at LANL. The goal is to build a single LANL benchmark collection that is up to date with the latest ICSBEP revision, has a formal review and revision process, is contained in an open-source repository, and utilizes new Python tools for improved input and output file review. This paper describes the validation of the models associated with HEU-MET-FAST-007, “Uranium Metal Slabs Moderated with Polyethylene, Plexiglas, and Teflon”. The Monte Carlo n-Particle (MCNP) models were compared to the second revision of HEU-MET-FAST-007. The experiment considered critical configurations of highly enriched uranium (HEU) metal slabs and various moderators in 43 unique cases. The slabs of uranium were separated by layers of moderating material, forming an assembly. The assembly was separated in two halves with one half placed on a stationary table and the other attached to a moveable table that could be raised and lowered via pulleys connected to the ceiling of the shielded room. To reach criticality, the two halves were brought together with a negligible gap between the assemblies.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Atmospheric Boundary-Layer and Flutter Computations Using CFD Model of the Transonic Dynamics Tunnel

This paper presents two Computational Fluid Dynamics (CFD) models of the flow in the NASA Langley Research Center Transonic Dynamics Tunnel (TDT). The TDT is a continuous-flow, closed circuit wind tunnel with a 16- by 16-foot slotted test section with cropped corners. The tunnel was originally built as the 19-ft Pressure Tunnel in 1938, but it was converted to the current transonic tunnel in the 1950s, with capabilities to use either air or heavy gas as the test medium. The first computational model describes the generation of an atmospheric-boundary-layer (ABL) profile inside the tunnel. An ABL, which includes both a wind profile and turbulence content, is one of the aerodynamic characteristics affecting the occurrence of wind-induced oscillations for a launch vehicle sitting on a pad. The challenging part of this analysis was modeling the turbulent flow inside the tunnel. This is due to the special ABL-generating hardware that was installed at the entrance of the TDT test section in order to change the downstream velocity profile and to introduce velocity fluctuations into the flow. The second CFD model builds on the computational aeroelastic results that were generated in support of the second Aeroelastic Prediction Workshop (AePW) for the NASA Benchmark Supercritical Wing (BSCW) configuration. During the AePW, the wing-only configuration (classical free-air model) was analyzed. In the current study, the flutter computations were conducted on the configuration as it was mounted in the TDT during the experiment. This includes the wing attached to the splitter plate that was attached to the wind-tunnel walls. The preliminary results show that the wind-tunnel walls marginally affect flutter prediction.

Pawel Chwalowski↗

Feasibility and performance of the staged Z-pinch: A one-dimensional study with FLASH and MACH2

Z-pinch platforms constitute a promising pathway to fusion energy research. Here, we present a one-dimensional numerical study of the staged Z-pinch (SZP) concept using the FLASH and MACH2 codes. We discuss the verification of the codes using two analytical benchmarks that include Z-pinch-relevant physics, building confidence on the codes' ability to model such experiments. Then, FLASH is used to simulate two different SZP configurations: a xenon gas-puff liner (SZP1*) and a silver solid liner (SZP2). The SZP2 results are compared against previously published MACH2 results, and a new code-to-code comparison on SZP1* is presented. Using an ideal equation of state and analytical transport coefficients, FLASH yields a fuel convergence ratio (CR) of approximately 39 and a mass-averaged fuel ion temperature slightly below 1 keV for the SZP2 scheme, significantly lower than the full-physics MACH2 prediction. For the new SZP1* configuration, full-physics FLASH simulations furnish large and inherently unstable CRs (>300) but achieve fuel ion temperatures of many kilo-electron volts. While MACH2 also predicts high temperatures, the fuel stagnates at a smaller CR. The integrated code-to-code comparison reveals how magnetic insulation, heat conduction, and radiation transport affect platform performance and the feasibility of the SZP concept.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Performance modeling & simulation of complex systems (A systems engineering design & analysis approach)

Modeling of the Multi-mission Image Processing System (MIPS) will be described as an example of the use of a modeling tool to design a distributed system that supports multiple application scenarios. This paper examines: (a) modeling tool selection, capabilities, and operation (namely NETWORK 2.5 by CACl), (b) pointers for building or constructing a model and how the MIPS model was developed, (c) the importance of benchmarking or testing the performance of equipment/subsystems being considered for incorporation the design/architecture, (d) the essential step of model validation and/or calibration using the benchmark results, (e) sample simulation results from the MIPS model, and (f) how modeling and simulation analysis affected the MIPS design process by having a supportive and informative impact.

Hall, Laverne↗

Importance of Internal Variability for Climate Model Assessment

Benchmarking climate model simulations against observations of the climate is core to the process of building realistic climate models and developing accurate future projections. However, in many cases, models do not match historical observations, particularly on regional scales. If there is a mismatch between modeled and observed climate features, should we necessarily conclude that our models are deficient? Using several illustrative examples, we emphasize that internal variability can easily lead to marked differences between the basic features of the model and observed climate, even when decades of model and observed data are available. This can appear as an apparent failure of models to capture regional trends or changes in global teleconnections, or simulation of extreme events. Despite a large body of literature on the impact of internal variability on climate, this acknowledgment has not yet penetrated many model evaluation activities, particularly for regional climate. We emphasize that using a single or small ensemble of simulations to conclude that a climate model is in error can lead to premature conclusions on model fidelity. A large ensemble of multidecadal simulations is therefore needed to properly sample internal climate variability in order to robustly identify model deficiencies and convincingly demonstrate progress between generations of climate models.

Climate and Earth system modelling↗

Building the Financial Business Case for Resilience

This fact sheet is designed to help owners, operators, occupants, and investors in commercial buildings and other sectors to understand and address emerging issues in resilience. It includes resources from DOE’s Better Buildings Financing and Resilience Roadmap to identify key issues in measuring, managing, and mitigating resilience risk.

Resilience, Resiliency, Commercial building, comme↗

Geothermal Direct-Use Applications for the District Energy System in Bucharest, Romania

The city of Bucharest, Romania, hosts the second-largest district energy system (DES) in the world. Geothermal resources can be considered as a supplementary heat source to support the demand for domestic hot water and space heating in the winter and shoulder seasons. The National Laboratory of the Rockies (NLR) has conducted a study that considers geothermal energy to serve a fraction of the existing district heating network operated by Electrocentrale Bucure?ti (ELCEN), the utility operating the DES. Lower Cretaceous and Jurassic limestones make up the main geothermal aquifer underlying Bucharest, which hosts temperatures suitable for district heating (up to 90 degrees C to the north of the city). Anomalous geothermal gradients have been observed to the north of the city, where a pumped well has produced 82 degrees C brine at the wellhead to feed the Therme Bucharest Spa. An anomalous gradient has also been reported to the southeast of the city (35 degrees C/km). NLR modeled the building heating loads of a small portion of the DES (a block of nine prototypical buildings) in its Urban Renewable Building and Neighborhood Optimization (URBANopt ) platform. To simulate meeting a baseload benchmark of 20 MWth deliverable to a small portion of the DES, the NLR team used GEOPHIRES to model production scenarios for (1) hydrothermal systems coupled with heat pumps targeting the main geothermal aquifer in the north, (2) enhanced geothermal systems targeting hot dry rock in the southeast, and (3) huff-and-puff systems targeting a gradient of 25 degrees C/km. Finally, NLR conducted a high-level sensitivity study around the techno-economics of these systems. The outcomes of this work indicate that hot dry rock geothermal resources that can deliver at least 90 degrees C hot water to the Geothermal District Energy System (GeoDES) offer a possible solution for supplemental geothermal heat delivered to the existing DES.

15 GEOTHERMAL ENERGY↗

A guideline to document occupant behavior models for advanced building controls

The availability of computational power, and a wealth of data from sensors have boosted the development of model-based predictive control for smart and effective control of advanced buildings in the last decade. More recently occupant-behavior models have been developed for including people in the building control loops. However, while important objectives of scientific research are reproducibility and replicability of results, not all information is available from published documents. Therefore, the aim of this paper is to propose a guideline for a thorough and standardized occupant-behavior model documentation. For that purpose, the literature screening for the existing occupant behavior models in building control was conducted, and the occupant behavior modeling processes were studied to extract practices and gaps for each of the following phases: problem statement, data collection, and preprocessing, model development, model evaluation, and model implementation. Here, the literature screening pointed out that the current state-of-the-art on model documentation shows little unification, which poses a particular burden for the model application and replication in field studies. In addition to the standardized model documentation, this work presented a model-evaluation schema that enabled benchmarking of different models in field settings as well as the recommendations on how OB models are integrated with the building system.

Building control↗

Microgravity Vibration Control and Civil Applications

Controlling vibration of structures is essential for both space structures as well as terrestrial structures. Due to the ambient acceleration levels anticipated for the International Space Station, active vibration isolation is required to provide a quiescent acceleration environment for many science experiments. An overview is given of systems developed and flight tested in orbit for microgravity vibration isolation. Technology developed for vibration control of flexible space structures may also be applied to control of terrestrial structures such as buildings and bridges subject to wind loading or earthquake excitation. Recent developments in modern robust control for flexible space structures are shown to provide good structural vibration control while maintaining robustness to model uncertainties. Results of a mixed H-2/H-infinity control design are provided for a benchmark problem in structural control for earthquake resistant buildings.

Whorton, Mark Stephen↗

Assessing Uncertainties and Approximations in Solar Heating of the Climate System

In calculating solar radiation, climate models make many simplifications, in part to reduce computational cost and enable climate modeling, and in part from lack of understanding of critical atmospheric information. Whether known errors or unknown errors, the community's concern is how these could impact the modeled climate. The simplifications are well known and most have published studies evaluating them, but with individual studies it is difficult to compare. Here, we collect a wide range of such simplifications in either radiative transfer modeling or atmospheric conditions and assess potential errors within a consistent framework on climate-relevant scales. We build benchmarking capability around a solar heating code (Solar-J) that doubles as a photolysis code for chemistry and can be readily adapted to consider other errors and uncertainties. The broad classes here include: use of broad wavelength bands to integrate over spectral features; scattering approximations that alter phase function and optical depths for clouds and gases; uncertainty in ice-cloud optics; treatment of fractional cloud cover including overlap; and variability of ocean surface albedo. We geographically map the errors in W m -2 using a full climate re-creation for January 2015 from a weather forecasting model. For many approximations assessed here, mean errors are ~2 W m -2 with greater latitudinal biases and are likely to affect a model’s ability to match the current climate state. Combining this work with previous studies, we make priority recommendations for fixing these simplifications based on both the magnitude of error and the ease or computational cost of the fix.

58 GEOSCIENCES↗

ChatPORT: Fine-Tuned LLM for Easy Code {PORT}ing

Fine-tuning existing LLMs for specialized tasks has become a very attractive alternative due to its low cost and quick development cycle. With many pre-trained LLMs available, it is an increasingly complex task to choose the correct model as the starting point or base model. In this work we discuss ChatPORT - a specialized fine-tuned LLM geared towards providing correctly translated codes from one programming model to another. We evaluate a number of base models and compare and contrast their features and characteristics that make them a viable starting point. In this paper, we focus on the OpenMP offload porting capabilities of ChatPORT. We build our training data using kernels from the Heterogeneous Computing Benchmarks (HeCBench) [12] and the OpenMP Validation and Verification suite [5] to fine-tune the base models. We then test the model using unseen kernels extracted from the HeCBench benchmark suite. Our results show that: (1) not all open LLMs geared towards HPC are aware of programming models like OpenMP, (2) although all base models benefit from fine-tuning they learn differently and produce different correctness rates, (3) depending on the memory size and compute resource available, different base models can be used for fine-tuning without significantly affecting the quality of transpiled code they generate, (4) fine-tuning improved the correctness rate of the LLM by an average of 43.2%, and (5) feedback-based training data further increased the correctness rate by an average of 6% over the LLMs tested.

Pophale, Swaroop [ORNL] (ORCID:0000000185446367)↗

Depletion Benchmark Analysis on a Lead Fast Reactor Using PyARC/OpenMC

PyARC is a user-friendly fast reactor analysis tool that automates multiphysics workflows using the “extended suite” of Argonne Reactor Computation (ARC) codes by providing a single common input for model definition, code execution, and output post-processing. A lead fast reactor (LFR) benchmark model is used to perform depletion calculations using the newly integrated OpenMC depletion capability in PyARC, building on previous analysis using the ARC codes through PyARC and Serpent. Results for core lifetime k-effective, shutdown decay heat, and end-of-life heavy-metal inventory are compared to verify the PyARC/OpenMC integration against the PyARC/ARC workflow and Serpent for depletion analysis of LFR designs. The results show satisfactory agreement among all three methods, with remaining discrepancies largely attributable to differences in nuclear data libraries and decay-chain modeling detail rather than to fundamental modeling limitations.

Kiesling, Kalin R.↗

Decarbonization of heat pump dual fuel systems using a practical model predictive control: Field demonstration in a small commercial building

In the transition from fossil fuel to electrified heating, a concerning trend is emerging in certain regions of the US. Owners of buildings with gas-based systems leave them in place after adding heat pumps (HPs). Existing control solutions for these hybrid (dual fuel) systems are rudimentary and fall short of realizing the full carbon reduction potential of these systems. Model predictive control (MPC) is often regarded as the benchmark for achieving optimal control in integrated systems. However, in the case of small-medium commercial buildings (SMCBs), the control and communication infrastructure required to facilitate the implementation of such advanced controls is often lacking. This paper presents a field implementation of easy-to-deploy MPC for a dual fuel heating system consisting of HPs and a gas-fired furnace (GF) for SMCBs. The control system is deployed on an open-source middleware platform and utilizes low-cost sensor devices to be used for real SMCBs without major retrofits. Here, we demonstrated this MPC in a real office building with 5 HPs and 1 GF for 2 months. The test results showed that MPC reduced 27% of cost while completely eliminating GF usage by shifting 23% of the thermal load from occupied-peak time to non-occupied-non-peak times.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

BrickQA: Bridging the Semantic Gap in Building Operations with Dynamic Graph Exploration

While standardized ontologies like the Brick schema address data heterogeneity in Building Automation Systems (BAS), accessing this semantic data remains a challenge as domain experts often lack the expertise to formulate complex SPARQL queries. To bridge this gap, we present BrickQA, a Large Language Model (LLM)-based framework that translates natural language into executable SPARQL queries through structured query decomposition, dynamic schema exploration, and inline validation. BrickQA utilizes an iterative reasoning agent to actively navigate graph topology through dynamic exploration actions without requiring exhaustive context injection or model fine-tuning. This approach effectively mitigates hallucinations, particularly in large-scale building knowledge graphs. Empirical evaluation on BuildingQA, a standardized benchmark, demonstrates that BrickQA significantly outperforms ReAct baselines, delivering a 0.291–0.355 absolute F1 improvement while achieving 3 × –12.7 × higher token cost-efficiency. Beyond these metrics, the framework maintains structural fidelity across heterogeneous buildings and remains resilient to ambiguous queries without requiring site-specific fine-tuning. Furthermore, a case study on operational analytics validates the framework’s capability to handle temporal and aggregation constraints, effectively transforming abstract semantic models into actionable facility management insights.1

Ko, Yun-Dam↗

Modeling Air Handling Units to Create a Diverse Fault Dataset for FDD Innovation: Lessons Learned and Recommendations

As energy management and information systems (e.g., automated fault detection and diagnostics [AFDD] tools) become more prevalent in the commercial building stock, it is important to determine the effectiveness of these technologies by benchmarking their performance. The authors have been working to develop the largest publicly available dataset of HVAC fault datasets for performance benchmarking applications, covering the most common HVAC systems and designs including chiller plants, rooftop packaged units, dual duct air handling unit and single duct air handling units. This study covers the development, modeling, and validation of a synthetic fault dataset for the air handling unit (AHU), one of the most common HVAC configurations found in the commercial building stock. Despite this being a common system, real-world time series data are scarce and usually do not span a wide range of weather conditions. Due to this limitation, two detailed AHU models, which included the single duct AHU and dual duct AHU developed in the Modelica language and HVACSIM+ were employed to carry out annual simulations of numerous common sensor faults, mechanical faults, and control sequence faults. The fault inclusive data were then validated by comparing fault effects on system performance to expected symptoms. We summarize the nature of each fault and their impacts under different weather and operation conditions. We report some lessons learnt during the efforts of validating the high volumes of the FDD data sets. Finally, we highlight considerations for FDD developers that may want to use this dataset to assess their algorithms’ performance and their improvement over time.

Casillas, Armando↗