Band-to-Band Misregistration of the Images of MODIS Onboard Calibrators and Its Impact on Calibration

The Moderate Resolution Imaging Spectroradiometer (MODIS) instruments aboard Terra and Aqua satellites are radiometrically calibrated on-orbit with a set of onboard calibrators (OBCs), including a solar diffuser, a blackbody, and a space view port through which the detectors can view the dark space. As a whisk-broom scanning spectroradiometer, thirty-six MODIS spectral bands are assembled in the along-scan direction on four focal plane assemblies (FPAs). These bands capture images of the same target sequentially with the motion of a scan mirror. Then the images are coregistered onboard by delaying the appropriate band-dependent amount of time, depending on the band locations on the FPA. While this coregistration mechanismis functioning well for the far-field remote targets such as earth view scenes or the moon, noticeable band-to-band misregistration in the along-scan direction has been observed for near field targets, particularly in OBCs. In this paper, the misregistration phenomenon is presented and analyzed. It is concluded that the root cause of the misregistration is that the rotating element of the instrument, the scan mirror, is displaced from the focus of the telescope primary mirror. The amount of the misregistrationis proportional to the band location on the FPA and is inversely proportional to the distance between the target and the scan mirror. The impact of this misregistration on the calibration of MODIS bands is discussed. In particular, the calculation of the detector gain coefficient m1of bands 8-16 (412 nm 870 nm) is improved by up to 1.5% for Aqua MODIS.

Wang, Zhipeng

Langley Automated Sensor Inter-calibration System (LASICS): Open Access Tools for Satellite Imager Inter- Calibration

Satellite imager calibration teams are tasked with maintaining stable measurement records to facilitate reliable monitoring of geophysical parameters and ensure dependable input for forecast models. Satellite imagers are neither uniformly calibrated nor radiometrically scaled to a common reference standard. Consistent inter-calibration between various earth-orbiting satellite imager pairs is a critical step in the creation of seamless earth-scene reflectance data records over time for input to higher level algorithms that retrieve earth system climate-sensitive properties. Each imager inherently by virtue of its optics (and associated properties like spectral response etc.) and orbit will have a unique measurement of the same earth-scene reflected signal. A key part of this is the computationally efficient and optimal identification and prediction of science opportunities where the imager pairs from the irrespective earth-orbits near-simultaneously view the same stable terrestrial targets with nearly identical viewing and solar geometry.

Arun Gopalan

Increased accuracy and signal-to-noise ratio through recent improvements in infra-red video bolometer fabrication and calibration

The infra-red video bolometer (IRVB) is a diagnostic equipped with an infra-red camera that measures the total radiated power in thousands of lines of sight within a large field of view. Recently validated in MAST-U [Fderici et al., Rev. Sci. Instrum. 94, 033502 (2023)], it offers a high spatial resolution map of the radiated power in the divertor region, where large gradients are expected. The IRVB’s sensing element comprises a thin layer of high Z absorbing material, typically platinum, usually coated with carbon to reduce reflections [Peterson et al., Rev. Sci. Instrum. 79, 10E301 (2008)].Here, the possibility of using a relatively inert material such as titanium, is explored that can be produced in layers up to 1 μm compared to 2.5 μm for Pt and then coat it with Pt of the desired thickness (0.3 μm per side here) and carbon. This leads to a higher temperature signal (about 3 times) and better spatial resolution (about 4 times), resulting in higher accuracy in the measured power [Peterson et al., Rev. Sci. Instrum. 79, 10E301 (2008)]. This assembly is also expected to improve foil uniformity, as the Pt layer is obtained via deposition rather than mechanical processes [Mukai et al., Rev. Sci. Instrum. 87, 2014 (2016)].Given its multi-material composition, measuring the thermal properties of the foil assembly is vital. Various methods using a calibrated laser as a heat source have been developed, analyzing the temperature profile shape [Sano et al., Plasma and Fusion Res. 7, 2405039 (2012)] and [Mukai et al., Rev. Sci. Instrum. 89, 10E114 (2018)] or fitting the calculated laser power for different intensities and frequencies [Fderici et al., Rev. Sci. Instrum. 94, 033502 (2023)]. Here, a simpler approach is presented, which relies on analyzing the separate components of the foil heat equation for a single laser exposure in a given area. This can then be iterated over the entire foil to capture local deviations.

Magnetic Fusion Energy

Spectral irradiance calibration in the infrared. I - Ground-based and IRAS broadband calibrations

Absolutely calibrated versions of realistic model atmosphere calculations for Sirius and Vega by Kurucz (1991) are presented and used as a basis to offer a new absolute calibration of infrared broad and narrow filters. In-band fluxes for Vega are obtained and defined to be zero magnitude at all wavelengths shortward of 20 microns. Existing infrared photometry is used differentially to establish an absolute scale of the new Sirius model, yielding an angular diameter within 1 sigma of the mean determined interferometrically by Hanbury Brown et al. (1974). The use of Sirius as a primary infrared stellar standard beyond the 20 micron region is suggested. Isophotal wavelengths and monochromatic flux densities for both Vega and Sirius are tabulated.

Cohen, Martin

Photometric calibration of the HST wide-field/planetary camera. II - Ground-based observations of calibration fields

Ground-based CCD observations have been made simulating the photometric properties of the Wide Field/Planetary Camera (WF/PC) of the Hubble Space Telescope. This paper gives results in 15 of the most important WF/PC passbands for two fields chosen to provide efficient in-flight calibration of the WF/PC. These calibration fields are located in the outskirts of the globular clusters Omega Cen and NGC 6752.

Harris, Hugh C.

PHILLS Vicarious Calibration: A WFS Experiment and Guidance for LEO-15 Calibration Efforts

On April 24, 2001, Florida Shelf Lagrangian Experiment (FSLE) cruises were accompanied by PHILLS hyperspectral overflights at 30,000 ft altitude. Robert Steward, and Jim Ivey collected remote sensing reflectance and water samples for absorption during two FSLE experiments. The PHILLS was flown on several transects over the area with vicarious calibration measurements conducted by USF from the R/V LINK. The USF slow-drop package was also deployed to collect inherent and apparent optical properties as a function of depth for an evaluation of effects of vertical structure on remote sensing spectra. The PHILLS imagery has been successfully calibrated. We show the procedures, results, derived bathymetry, and some noise effects with a 3 s period.

Carder, Kendall L.

The Calibration of AVHRR/3 Visible Dual Gain Using Meteosat-8 as a MODIS Calibration Transfer Medium

This viewgraph presentation reviews the NOAA-17 AVHRR visible channels calibrated against MET-8/MODIS using dual gain regression methods. The topics include: 1) Motivation; 2) Methodology; 3) Dual Gain Regression Methods; 4) Examples of Regression methods; 5) AVHRR/3 Regression Strategy; 6) Cross-Calibration Method; 7) Spectral Response Functions; 8) MET8/NOAA-17; 9) Example of gain ratio adjustment; 10) Effect of mixed low/high count FOV; 11) Monitor dual gains over time; and 12) Conclusions

Avey, Lance

Swift Mission Gyro Patch and Re-Calibration Without A Calibration Campaign

The Swift spacecraft has three Two-Axis-Rate-Assemblies (TARAs) (designated as TARA 1, TARA 2, and TARA 3, and generically referred to as gyros) which until March of 2024 were all used in rate estimation as an operational workaround (dubbed “corrector-gyro”) of a software defect discovered in 2007. TARA 1 performance degraded throughout 2023 and 2024, making it an unreliable rate source. It was determined that shifting TARA 1 to be the corrector-gyro and using mainly TARAs 2 and 3, with the existing flight software (FSW) defect, would not meet performance requirements for science operations. Rather the FSW was patched to remove the defect found in 2007. This patch was delivered by the vendor in 2009, but was not fully tested or installed at that time. A decision was made in 2024 to install the patch despite limited simulation and testing capabilities. The problem facing the team was to come up with a set of alignment parameters that would work with the new patch, using data from the spacecraft operating normally in the old configuration. Calibration activities would have been possible in either the old or new FSW configuration, but were ultimately deemed unnecessary, saving staff time and pre-serving time on the spacecraft for science data collection. This paper describes the old and new FSW configurations related to gyro processing and alignment, and how the raw gyro and star tracker data from normal operation were used with a multidimensional unconstrained nonlinear minimization in MATLAB (Nelder-Mead1) to produce a fully calibrated set of gyro alignment parameters compatible with the patched FSW. Flight data is presented showing that not only did the process work, it improved performance significantly, rivaling the best slew performance of the mission to date.

MATLAB

Calibrating the simple biosphere model for Amazonian tropical forest using field and remote sensing data. I - Average calibration with field data

Using meteorological and hydrological measurements taken in and above the central-Amazon-basin tropical forest, calibration of the Sellers et al. (1986) simple biosphere (SiB) model are described. The SiB model is a one-dimensional soil-vegetation-atmosphere model designed for use within GCMs models, representing the vegetation cover by analogy with processes operating within a single representative plant. The experimental systems and the procedures used to obtain field data are described, together with the specification of the physiological parameterization required to provide an average description of data. It was found that some of the existing literature on stomatal behavior for tropical species is inconsistent with the observed behavior of the complete canopy in Amazonia, and that the rainfall interception store of the canopy is considerably smaller than originally specified in the SiB model.

Sellers, Piers J.

Volume 1. Preliminary design study: AXAF x ray calibration spectrometers. Volume 2. Revised preliminary design study: AXAF x ray calibration spectrometers

The objective of this work was to provide a preliminary design concept for a Flux Monitor Spectrometer (FMS) for use at the X Ray Astrophysics Facility (XRAF) during High Resolution Mirror Assembly (HRMA) testing that met the requirements of SAO-AXAF-88-025 dated July 31, 1991. The calibration test team determined that the spectral resolution of the FMS had to be greater than or equal to twice that of all the AXAF spectrometers throughout the 0.1 to 10 KeV range of x-ray energies. Since this effectively doubled the resolution required by SAO-AXAF-88-025, a change order was approved by the Marshall Space Flight Center and given to Radiation Sciences to revise their study.