Search NASA⌕ Search

SEARCH · Search NASA

Results for “CF algorithm”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 55 records · Page 3

Development of Pseudorandom Binary Arrays for Calibration of Surface Profile Metrology Tools

Optical metrology tools, especially for short wavelengths (extreme ultraviolet and x-ray), must cover a wide range of spatial frequencies from the very low, which affects figure, to the important mid-spatial frequencies and the high spatial frequency range, which produces undesirable scattering. A major difficulty in using surface profilometers arises due to the unknown point-spread function (PSF) of the instruments [G. D. Boreman, Modulation Transfer Function in Optical and Electro-Optical Systems (SPIE, Bellingham, WA, 2001)] that is responsible for distortion of the measured surface profile. Generally, the distortion due to the PSF is difficult to account for because the PSF is a complex function that comes to the measurement via the convolution operation, while the measured profile is described with a real function. Accounting for instrumental PSF becomes significantly simpler if the result of measurement of a profile is presented in the spatial frequency domain as a power spectral density (PSD) distribution [J. W. Goodman, Introduction to Fourier Optics, 3rd ed. (Roberts and Company, Englewood, CO, 2005)]. For example, measured PSD distributions provide a closed set of data necessary for three-dimensional calculations of scattering of light by the optical surfaces [E. L. Church et al., Opt. Eng. (Bellingham) 18, 125 (1979); J. C. Stover, Optical Scattering, 2nd ed. (SPIE Optical Engineering Press, Bellingham, WA, 1995)]. The distortion of the surface PSD distribution due to the PSF can be modeled with the modulation transfer function (MTF), which is defined over the spatial frequency bandwidth of the instrument. The measured PSD distribution can be presented as a product of the squared MTF and the ideal PSD distribution inherent for the system under test. Therefore, the instrumental MTF can be evaluated by comparing a measured PSD distribution of a known test surface with the corresponding ideal numerically simulated PSD. The square root of the ratio of the measured and simulated PSD distributions gives the MTF of the instrument. The applicability of the MTF concept to phase map measurements with optical interferometric microscopes needs to be experimentally verified as the optical tool and algorithms may introduce nonlinear artifacts into the process. In previous work [V. V. Yashchuk et al., Proc. SPIE 6704, 670408 (2007); Valeriy V. Yashchuk et al., Opt. Eng. (Bellingham) 47, 073602 (2008)] the instrumental MTF of a surface profiler was precisely measured using reference test surfaces based on binary pseudorandom (BPR) gratings. Here, the authors present results of fabricating and using two-dimensional (2D) BPR arrays that allow for a direct 2D calibration of the instrumental MTF. BPR sequences are widely used in engineering and communication applications such as global position systems and wireless communication protocols. The ideal BPR pattern has a flat 'white noise' response over the entire range of spatial frequencies of interest. The BPR array used here is based on the uniformly redundant array (URA) prescription [E. E. Fenimore and T. M. Cannon, Appl. Opt. 17, 337 (1978)] initially used for x-ray and gamma ray astronomy applications. The URA's superior imaging capability originates from the fact that its cyclical autocorrelation function very closely approximates a delta function, which produces a flat PSD. Three different size BPR array patterns were fabricated by electron beam lithography and induction coupled plasma etching of silicon. The basic size units were 200, 400, and 600 nm. Two different etch processes were used, CF{sub 4}/Ar and HBr, which resulted in undercut and vertical sidewall profiles, respectively. The 2D BPR arrays were used as standard test surfaces for MTF calibration of the MicroMap{trademark}-570 interferometric microscope using all available objectives. The MicroMap{trademark}-570 interferometric microscope uses incoherent illumination from a tungsten filament source and common path modulated phase shifting interference to produce a set of interferograms detected on a change coupled device. Mathematical algorithms applied to the datasets yield the surface phase map. The HBr etched two-dimensional BPR arrays have proven to be a very effective calibration standard making possible direct calibration corrections without the need of additional calculation considerations, while departures from the ideal vertical sidewall require an additional correction term for the CF{sub 4}/Ar etched samples [Samuel K. Barber et al., Abstract to Optics and Photonics 2009: Optical Engineering and Applications Symposium, San Diego, CA, 2-6 August 2009]. Initial surface roughness of low cost 'prime' wafers limits low magnification calibration but should not be a limitation if better polished samples are used.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Quantifying uncertainties on fission fragment mass yields with mixture density networks

Probabilistic machine learning techniques can learn both complex relations between input features and output quantities of interest as well as take into account stochasticity or uncertainty within a data set. In this initial work, we explore the use of one such probabilistic network, the mixture density network (MDN), to reproduce fission yields and their uncertainties. In this paper, we study mass yields for the spontaneous fission of 252 Cf, exploring the number of training samples needed for converged predictions, how different levels of uncertainty propagate from the training set to the MDN predictions, and how well physical constraints of the yields—such as normalization and symmetry—are upheld by the algorithm. Finally, we test the ability of the MDN to interpolate between and extrapolate beyond samples in the training set using energy-dependent mass yields for the neutron-induced fission on 235 U. The MDN provides a reliable way to include and predict uncertainties and is a promising path forward for supplementing sparse sets of nuclear data.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Modeling Wavelength Dependent Mid-infrared (5.5–25 μm) Optical Constants of Silicate Glasses: A Genetic Algorithm Approach

Wavelength-dependent mid-infrared (400–1,800 cm -1 ; 5.56–25 μm) optical constants (real and imaginary indices of refraction; n and k) are determined using reflectance spectra at a spectral sampling of 4 cm -1 for several silicate glasses of varying SiO 2 wt% which include (a) basaltic volcanic glass from Kilauea, Hawaii, (b) synthetic andesite, (c) two synthetic dacites, (d) obsidian volcanic glass from Mount Lassen, California, (e) synthetic rhyodacite, and (f) rhyolitic volcanic glass from Mexico. Because glasses are optically isotropic, no specific orientation was required for spectral measurements, and polished glass samples were measured at random orientations using micro-FTIR spectrometer. Lorentz-Lorenz dispersion theory and Fresnel reflectance model for high symmetry materials were used to model the optical constants by optimizing oscillator parameters in modeled spectra to match laboratory spectra. A genetic algorithm (GA) approach automatically finds the natural oscillators and their parameters for each spectrum, and then uses these parameters in a non-linear least squares optimization routine. The study compared spectral parameters such as Christiansen feature, reststrahlen bands (RBs), and the peaks centered around 860–1,100 (peak 1) and 400–480 cm -1 (peak 2) of n and k to their respective SiO 2 wt% of the glasses. CF, RBs, peak 1 of n and k, and peak 2 of n shift to higher wavenumbers with increased SiO 2 wt%, whereas peak 2 of k shifts to lower wavenumbers with increased SiO 2 wt%. Derived optical constants of these glasses will improve quantitative abundance mapping of volcanic materials on the surfaces of silicate targets in the Solar System.

58 GEOSCIENCES↗

Phase Imaging: A Compressive Sensing Approach

Since Wolfgang Pauli posed the question in 1933, whether the probability densities |Ψ(r)|² (real-space image) and |Ψ(q)|² (reciprocal space image) uniquely determine the wave function Ψ(r) [1], the so called Pauli Problem sparked numerous methods in all fields of microscopy [2, 3]. Reconstructing the complete wave function Ψ(r) = a(r)e-iφ(r) with the amplitude a(r) and the phase φ(r) from the recorded intensity enables the possibility to directly study the electric and magnetic properties of the sample through the phase. In transmission electron microscopy (TEM), electron holography is by far the most established method for phase reconstruction [4]. Requiring a high stability of the microscope, next to the installation of a biprism in the TEM, holography cannot be applied to any microscope straightforwardly. Recently, a phase retrieval approach was proposed using conventional TEM electron diffractive imaging (EDI). Using the SAD aperture as reciprocal-space constraint, a localized sample structure can be reconstructed from its diffraction pattern and a real-space image using the hybrid input-output algorithm [5]. We present an alternative approach using compressive phase-retrieval [6]. Our approach does not require a real-space image. Instead, random complimentary pairs of checkerboard masks are cut into a 200 nm Pt foil covering a conventional TEM aperture (cf. Figure 1). Used as SAD aperture, subsequently diffraction patterns are recorded from the same sample area. Hereby every mask blocks different parts of gold particles on a carbon support (cf. Figure 2). The compressive sensing problem has the following formulation. First, we note that the complex-valued reciprocal-space wave-function is the Fourier transform of the (also complex-valued) real-space wave-function, Ψ(q) = F[Ψ(r)], and subsequently the diffraction pattern image is given by |Ψ(q)|2 = |F[Ψ(r)]|2. We want to find Ψ(r) given a few differently coded diffraction pattern measurements yn = |F[HnΨ(r)]|2, where the matrices Hn encode the mask structure of the aperture. This is a nonlinear inverse problem, but has been shown to be solvable even in the underdetermined case [6]. Since each diffraction pattern yn contains diffraction information from selected regions of the same sample, the differences in each pattern contain local phase information, which can be combined to form a full estimate of the real-space wave-function[7]. References: [1] W. Pauli in “Die allgemeinen Prinzipien der Wellenmechanik“, ed. H Geiger and W Scheel, (Julius Springer, Berlin). [2] A. Tonomura, Rev. Mod. Phys. 59 (1987), p. 639. [3] J. Miao et al, Nature 400 (1999), p. 342. [4] H. Lichte et al, Annu. Rev. Mater. Res. 37 (2007), p. 539. [5] J. Yamasaki et al, Appl. Phys. Lett. 101 (2012), 234105. [6] P Schniter and S Rangan. Signal Proc., IEEE Trans. on. 64(4), (2015), pp. 1043. [7] Supported by the Chemical Imaging, Signature Discovery, and Analytics in Motion initiatives at PNNL. PNNL is operated by Battelle Memorial Inst. for the US DOE; contract DE-AC05-76RL01830.

Schneider, Sebastian↗

A New Safeguards Technique for Spent Fuel Verification in Dry Storage by Using He-4 Detectors - 18262

It is demanded to find key issues and critical paths for verifying and monitoring a spent nuclear fuel cask or storage with a purpose of non-proliferation of nuclear weapon. However, unfortunately there are no reliable methods to verify the containment in a spent nuclear fuel cask or storage. Therefore, research and development (R and D) has been continuously required to develop new and alternative technologies for searching and verifying undeclared nuclear materials, activities, and facilities. Therefore, the present authors have developed a new safeguards technique of passively scanning a spent fuel cask or storage using pressurized He-4 scintillation neutron detectors. A new approach is to quickly verify content in a spent nuclear fuel cask or presence of all special nuclear materials in unknown packages by comparing experimental and computational results. For that, the present authors have developed a new algorithm and user-interface coupled ORIGEN-ARP and MCNP codes, and the prototype safeguards apparatus employing the array of He-4 fast neutron detectors has been designed, built, and tested. The feasibility test of this new apparatus has been performed with Cf-252 neutron sources and the laboratory scale model cask, minimized by a factor of ten compared to the actual dimension of a KN-21 cask. This technique has several advantages over current methods based on neutron and gamma detection; (1) incident neutron energy information is preserved, (2) disturbance of gamma-ray is excellently rejected (discriminated), and (3) much higher neutron counts and operational cost and space-effectiveness are expected since no moderator is required for fast neutrons. The final goal of this study will (1) conduct a prototype instrument and employ it to monitor a nuclear spent fuel cask or storage at a commercial nuclear power reactor facilities, (2) use spectral-specific measurement data to show proof of concept for measurable data successfully converted to quantifiable signatures, such as diversion/removal of fuel, and maintenance of fuel and cask integrity of fuel, and (3) develop a cask imaging capability. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

An event-triggered coincidence algorithm for fast-neutron multiplicity assay corrected for cross-talk and photon breakthrough

Here, a model quantifying detector cross-talk and the misidentification of events in fast neutron coincidence distributions is described. This is demonstrated for two experimental arrangements comprising rings of 8 and 15 organic liquid scintillation detectors. Correction terms developed as part of this model are tested with 252 Cf and a relationship is developed between the 235 U enrichment of U 3 O 8 and the order of correlated, fast neutron multiplets induced by an americium–lithium source. The model is also supported by Geant4 simulations. The results suggest that a typical assay, for experimental arrangements that are similar to the examples investigated in this research, will exhibit cross-talk for less than 1% of all detected fast neutrons but, if not accounted for, this can bias the numerical analysis by a margin of 10% and 35% in second- and third-order coincidences (i.e. couplet and triplet counts), respectively. Further, for the case of 252 Cf, it is shown that a relatively low proportion of 4% breakthrough by rays (that is, photons misidentified as neutrons by the pulse-shape discrimination process) can lead to an erroneous increase of 20% in total neutron counts in the assay of a mixed-field, in this case of 252 Cf. These findings will help direct the developments needed to enable organic scintillation detectors with pulse shape discriminators to be applied reliably to nuclear safeguards and non-proliferation verification tasks.

42 ENGINEERING↗

Development of a cold-neutron imaging detector based on thick gaseous electron multiplier

We present the results of our recent studies on a cold-neutron imaging detector prototype based on THick Gaseous Electron Multiplier (THGEM). The detector consists of a thin Boron layer, for neutron-to-charged particle conversion, coupled to two THGEM electrodes in cascade for charge amplification and a position-sensitive charge-readout anode. The detector operates in Ne/(5%)CF{sub 4}, at atmospheric pressure, in a stable condition at a gain of around 10{sup 4}. Due to the geometrical structure of the detector elements (THGEM geometry and charge read-out anode), the image of detector active area shows a large inhomogeneity, corrected using a dedicated flat-filed correction algorithm. The prototype provides a detection efficiency of 5% and an effective spatial resolution of the order of 1.3 mm.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Localization and spectral isolation of special nuclear material using stochastic image reconstruction

Here, in this work we present a technique for isolating the gamma-ray and neutron energy spectra from multiple radioactive sources localized in an image. Image reconstruction algorithms for radiation scatter cameras typically focus on improving image quality. However, with scatter cameras being developed for non-proliferation applications, there is a need for not only source localization but also source identification. This work outlines a modified stochastic origin ensembles algorithm that provides localized spectra for all pixels in the image. We demonstrated the technique by performing three experiments with a dual-particle imager that measured various gamma-ray and neutron sources simultaneously. We showed that we could isolate the peaks from 22 Na and 137 Cs and that the energy resolution is maintained in the isolated spectra. To evaluate the spectral isolation of neutrons, a 252 Cf source and a PuBe source were measured simultaneously and the reconstruction showed that the isolated PuBe spectrum had a higher average energy and a greater fraction of neutrons at higher energies than the 252 Cf. Finally, spectrum isolation was used for an experiment with weapons grade plutonium, 252 Cf, and AmBe. The resulting neutron and gamma-ray spectra showed the expected characteristics that could then be used to identify the sources.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Prototype Stilbene Neutron Collar II

A neutron collar using stilbene organic scintillator cells for fast neutron counting is described for the assay of fresh low enriched uranium (LEU) fuel assemblies. The prototype stilbene collar has a form factor similar to standard He-3 based collars and uses an AmLi interrogation neutron source. This report describes the simulation, using a custom LLNL developed MCNPX, of list mode neutron correlation data on various fuel assemblies. Some of these fuel assemblies have neutron absorbers (burnable Gd poisons) and partial defect s (DU, Fe, Pb pins). Calibration curves (doubles vs 235 U linear mass density) are presented for fast (with Cd lining) mode of operation. The modeling incorporates LLNL developed neutron crosstalk correction algorithms and stilbene light output detector response quench function. Pileup issues are addressed using the LLNL code GamGen / RadSrc to estimate the flux of alpha decay gammas from the fuel assemblies on the stilbene cells with and without Pb shielding. One panel of the prototype collar using 10 high-efficiency 4”x2” stilbene cells from Inrad Optics, using LLNL developed technology, has been constructed and calibrated for optimal PSD and data acquisition electronics. Several sources (AmLi, AmBe, Cf, DD, and DT) have been measured with the single panel and the measured data is consistent with the modeling. A novel part of our work was to determine the light output (LO) quench function for the Inrad 4” x 2” stilbene crystals through a LLNL-MCNPX simulation based optimized fitting of the measured LO data.

42 ENGINEERING↗

Applications of Event-by-Event Fission Modeling with FREYA

The recently developed code FREYA (Fission Reaction Event Yield Algorithm) generates large samples of complete fission events, consisting of two receding product nuclei as well as a number of neutrons and photons, all with complete kinematic information. Thus it is possible to calculate arbitrary correlation observables whose behavior may provide unique insight into the fission process. We first discuss the present status of FREYA, which has now been extended to include spontaneous fission. Concentrating on {sup 239}Pu(n{sub th},f), {sup 240}Pu(sf) and {sup 252}Cf(sf), we discuss the neutron multiplicity correlations, the dependence of the neutron energy spectrum on the neutron multiplicity, and the relationship between the fragment kinetic energy and the number of neutrons and their energies. We also suggest novel fission observables that could be measured with modern detectors.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

WE-G-18A-01: JUNIOR INVESTIGATOR WINNER - Low-Dose C-Arm Cone-Beam CT with Model-Based Image Reconstruction for High-Quality Guidance of Neurosurgical Intervention

Purpose: To address the challenges of image quality, radiation dose, and reconstruction speed in intraoperative cone-beam CT (CBCT) for neurosurgery by combining model-based image reconstruction (MBIR) with accelerated algorithmic and computational methods. Methods: Preclinical studies involved a mobile C-arm for CBCT imaging of two anthropomorphic head phantoms that included simulated imaging targets (ventricles, soft-tissue structures/bleeds) and neurosurgical procedures (deep brain stimulation (DBS) electrode insertion) for assessment of image quality. The penalized likelihood (PL) framework was used for MBIR, incorporating a statistical model with image regularization via an edgepreserving penalty. To accelerate PL reconstruction, the ordered-subset, separable quadratic surrogates (OS-SQS) algorithm was modified to incorporate Nesterov's method and implemented on a multi-GPU system. A fair comparison of image quality between PL and conventional filtered backprojection (FBP) was performed by selecting reconstruction parameters that provided matched low-contrast spatial resolution. Results: CBCT images of the head phantoms demonstrated that PL reconstruction improved image quality (∼28% higher CNR) even at half the radiation dose (3.3 mGy) compared to FBP. A combination of Nesterov's method and fast projectors yielded a PL reconstruction run-time of 251 sec (cf., 5729 sec for OS-SQS, 13 sec for FBP). Insertion of a DBS electrode resulted in severe metal artifact streaks in FBP reconstructions, whereas PL was intrinsically robust against metal artifact. The combination of noise and artifact was reduced from 32.2 HU in FBP to 9.5 HU in PL, thereby providing better assessment of device placement and potential complications. Conclusion: The methods can be applied to intraoperative CBCT for guidance and verification of neurosurgical procedures (DBS electrode insertion, biopsy, tumor resection) and detection of complications (intracranial hemorrhage). Significant improvement in image quality, dose reduction, and reconstruction time of ∼4 min will enable practical deployment of low-dose C-arm CBCT within the operating room. AAPM Research Seed Funding (2013-2014); NIH Fellowship F32EB017571; Siemens Healthcare (XP Division)

60 APPLIED LIFE SCIENCES↗

An Experimental Feasibility Study on Applying Neutron Tomography to Encapsulated Spent Nuclear Fuel - 20050

Visual inspection makes easier to ensure the integrity and safety of spent nuclear fuel (SNF) than any classical techniques. Various classical techniques have been applied but there are no reliable methods to qualitatively and quantitatively verify spent fuel in dry storage. Thus, the present authors have developed the prototype safeguards apparatus for dry storage employing the array of He-4 gas scintillation detectors (S670E, Arktis Radiation Detectors Ltd., Switzerland), newly designed to simultaneously measure thermal and fast neutrons without any moderators. The S670E detector has a cylindrical shape with a diameter of 52 mm and active length of 600 mm (total length: 875 mm). The detector is filled by He-4 gas with an approximate pressure of 180 bar for fast neutron detection, and its inner wall is coated by Li-6 for thermal neutron detection. The scintillation lights generated via Li-6 nuclear reaction and elastic scattering are collected by 24 SiPMs linearly paired at the center of the detector. The detector delivers a TTL (Transistor-Transistor Logic) output for pulse readout and UART (Universal Asynchronous Receiver Transmitter) for device control. In order to assess feasibility of the apparatus, an experimental system has been designed, built, and optimized via computational studies. Cf-252 neutron sources and linearly arrayed detectors, working as a single detector, were occupied for this study due to the difficulties in working with SNF. The laboratory scale cask (diameter: 0.67 m, height: 1.5 m), minimized by a factor of 10 compared to the actual thickness of a commercial TN-32 cask, was also manufactured. The detector array was designed to rotate the lab-scale cask and obtain 36 image profiles at every 10 degrees. All profiles were aligned in single frame image called a sinogram, and the cross-sectional image was then fabricated by the inverse radon transform algorithm. These experiments have been repeated with different configurations and numbers of sources. Some gamma-ray sources were also measured with neutron sources in order to distinguish between neutron and gamma-ray pulses. Basically, a He-4 detector is designed to run on Linux OS so it is difficult to directly apply to Windows-based equipment widely used in S. Korea. Therefore, a new data acquisition board working on Windows OS was designed and built. The board mainly consists of FPGA (Field Programmable Gate Array) and SoC (System on Chip) for TTL pulse readout, sorting measured data, and transferring data to a user interface. In conclusion, the tomographic system at lab-scale has shown considerable potential to detect a partial or gross defect of encapsulated assemblies in dry storage. Next steps of this study will be to 1) repeatedly carry out experiments to demonstrate scientific reliability and validity, and 2) numerically integrate signals with weight factors to enhance the image quality since the suggested system based on passive interrogation method requires longer measurement time. Finally, the system will apply to a commercial dry storage phased out soon in S. Korea. (authors)

07 ISOTOPE AND RADIATION SOURCES↗

Correlated Production and Analog Transport of Fission Neutrons and Photons Using Fission Models FREYA, FIFRELIN, and the Monte Carlo Code TRIPOLI-4

Fission modeling in general-purpose Monte Carlo transport codes often relies on average nuclear data provided by the international evaluation libraries. As such, only average fission multiplicities are available and correlations between fission neutrons and photons are missing. Whereas uncorrelated fission physics is usually sufficient for standard reactor core and radiation shielding calculations, correlated fission secondaries are required for specialized nuclear instrumentation and detector modeling. For coincidence counting detector optimization for instance, the precise simulation of fission neutrons and photons that remain correlated in time from birth to detection is essential. New developments were recently integrated into the Monte Carlo transport code TRIPOLI-4 to model fission physics more precisely, the purpose being to access event-by-event fission events from two different fission models: Fission Reaction Event Yield Algorithm (FREYA) and Fission Fragment Evaporation Leading to an Investigation of Nuclear Data (FIFRELIN). TRIPOLI-4 simulations can now be performed, either by connecting via an application programming interface to the Lawrence Livermore National Laboratory fission library including FREYA, or by reading the external fission event data files produced by FIFRELIN beforehand. These new capabilities enable us to easily compare results from the Monte Carlo transport calculations using the two fission models in a nuclear instrumentation application. In the first part of this paper, the broad underlying principles of the two fission models are recalled. We then present the experimental measurements of neutron angular correlations for 252 Cf(sf) and 240 Pu(sf). The correlations were measured for several neutron kinetic energy thresholds. In the latter part of this paper, simulation results are compared with the experimental data. Spontaneous fissions in 252 Cf and 240 Pu are modeled by FREYA or FIFRELIN. Emitted neutrons and photons are subsequently transported to an array of scintillators by TRIPOLI-4 in the analog mode to preserve their correlations. Angular correlations between fission neutrons obtained independently from these TRIPOLI-4 simulations, using either FREYA or FIFRELIN, are compared with the experimental results. In conclusion, for 240 Pu(sf), the measured correlations were used to tune one of the FREYA model parameters. Similarly, different sets of parameters have been tested in FIFRELIN to try to improve the agreement with the experimental data.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

A comparison of Monte Carlo fission models for safeguards neutron coincidence counters

Monte Carlo simulation is a powerful tool used to model neutron coincidence detectors for international safeguards. The simulation has typically sampled properties such as the fission neutron multiplicity, energy, and direction, from independent probability density functions. However, multiplicity counters detect event-based neutron correlations and thus more accurate fission event modeling is needed. To respond to this need, the Fission Reaction Event Yield Algorithm (FREYA) and the Cascading Gamma-ray Multiplicity with Fission (CGMF) models were added in the newest version of MCNP, MCNP6.2. The models simulate individual fission events conserving momentum, energy, and angular momentum such that correlated particles are emitted. The effects of the new models on simulations of safeguards neutron coincidence counters were studied and compared to standard MCNP simulations. The MCNPX-PoliMi model was also included in the comparison. The properties of fission neutrons from safeguards relevant isotopes were compared to literature references. Then a hypothetical simplified detector was modeled to isolate the effects of specific differences between models. Experimental measurements from previous work were modeled and agreements were compared. Lastly, the probabilities of correlated events occurring in the experimental measurements were calculated with the different models. For example, the probability was calculated of detecting neutrons from both induced fission in uranium and spontaneous fission of Cf-252 in the same fission chain.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Overset-Grid Method with Smooth Orbital Partitioning for Molecular Scattering Calculations

To solve molecular photoionization and electron scattering problems, we use an overset-grid representation of electronic continuum functions, which has an extended central spherical grid that overlaps small spherical grids (subgrids) centered on each atom of a polyatomic molecule. Here, in this work, we present an improved algorithm that smoothly partitions the total wave function between the central grid and the atomic subgrids. The smooth partitioning allows one to use approximately one-fourth the number of partial waves on the central grid compared to our previous implementation with switching functions. The resulting numerical method for treating electron scattering and photoionization of polyatomic molecules combines the accuracy and flexibility of pure numerical grid representations with the rapid convergence of hybrid combinations of atom-centered basis-set expansions and grid methods. The overset-grid representation is implemented using the complex Kohn variational principle for scattering and photoionization amplitudes. The faster convergence with respect to the number of central grid partial waves is demonstrated and accuracy is verified by comparisons with the previous implementation and with far more computationally demanding single-center numerical expansions in electron-molecule scattering and photoionization calculations on the neon dimer (Ne 2 ) system, carbon tetrafluoride (CF 4 ) molecule, and the pyridine (C 5 H 5 N) molecule in the static-exchange approximation.

Molecules↗

Data from: 'Abiotic influences on continuous conifer forest structure across a subalpine watershed'

This package archives the core data used for analysis and inference in 'Abiotic influences on continuous conifer forest structure across a subalpine watershed' (Worsham et al., 2025). All data were collected in the East River, Washington Gulch, Slate River, and Coal Creek watersheds of Colorado. In the paper, we quantified the relative influence of climate, topographic, edaphic, and geologic factors on conifer stand structure and composition, and their functional relationships, at the watershed scale. We used waveform LiDAR data to derive spatially continuous stand structure metrics. We fused these with a species-level classification map to estimate tree species abundance. We applied generalized additive and generalized boosted models to evaluate the covariability of structural and compositional metrics with abiotic variables. The package contains the essential products required for reproducing our analysis and the tables and figures reported in the publication. The products comprise four classes: (1) geospatial data, (2) tabular data used for inferential analysis, (3) tabular data describing analytical results and performance statistics, and (4) a data user guide. (1) includes discretized waveform LiDAR data, locations and attributes of individual tree crowns, sampling locations and domain boundaries, a canopy height model, and raster files of estimated forest structural and compositional metrics at 100 m grid scale. (2) includes all response and explanatory variable values applied in inferential models. Response variables include conifer forest stand density, basal area, 95th percentile height, quadratic mean diameter, and others. Explanatory variables include climatic water deficit, actual evapotranspiration, elevation, heat load, soil available water content, and others. (3) includes results of training and testing several individual tree detection (ITD) algorithms, as well as inferential modeling results. (4) is a PDF user guide for this data package, including detailed descriptions and data dictionaries for all files. The data package root contains 17 assets: 8 compressed tape archive (.tar.gz) files, 5 comma-separated values (.csv) files, 3 Geographic Tagged Image File Format (GeoTIFF) (.tif) files, and 1 Portable Document Format (.pdf) file. The compressed .tar.gz archives contain ESRI shapefiles (.shp) .tif, compressed LASer (.laz), and .csv files. The archives must first be decompressed using the widely distributed command-line software utility TAR. All other files, including constituent files within the .tar.gz archives, can be opened in the open-source R statistical computing environment. Alternatively, .csv files may also be read in any simple text editor software or Microsoft Excel. Geospatial files including .shp and .tif files can also be opened in GIS software, such as QGIS (open-source) or ESRI ArcGIS (proprietary). The .pdf Data User Guide can be read with Adobe Acrobat Reader or other compatible readers.

2018 NEON and 2025 CHESS Campaigns↗

Organic liquid scintillation detectors for on-the-fly neutron/gamma alarming and radionuclide identification in a pedestrian radiation portal monitor

Here, we present new experimental results from a radiation portal monitor based on the use of organic liquid scintillators. The system was tested as part of a 3 He-free radiation portal monitor testing campaign at the European Commission’s Joint Research Centre in Ispra, Italy, in February 2014. The radiation portal monitor was subjected to a wide range of test conditions described in ANSI N42.35, including a variety of gamma-ray sources and a 20,000 n/s 252 Cf source. A false alarm test tested whether radiation portal monitors ever alarmed in the presence of only natural background. The University of Michigan Detection for Nuclear Nonproliferation Group’s system triggered zero false alarms in 2739 trials. It consistently alarmed on a variety of gamma-ray sources travelling at 1.2 m/s at a 70 cm source to detector distance. The neutron source was detected at speeds up to 3 m/s and in configurations with up to 8 cm of high density polyethylene shielding. The success of on-the-fly radionuclide identification varied with the gamma-ray source measured as well as with which of two radionuclide identification methods was used. Both methods used a least squares comparison between the measured pulse height distributions to library spectra to pick the best match. The methods varied in how the pulse height distributions were modified prior to the least squares comparison. Correct identification rates were as high as 100% for highly enriched uranium, but as low as 50% for 241 Am. Lastly, both radionuclide identification algorithms produced mixed results, but the concept of using liquid scintillation detectors for gamma-ray and neutron alarming in radiation portal monitor was validated.

3He replacement technology↗

Energy Exascale Earth System Model v2.0.1

First patch release of v2.0.0 Changes since v2.0.0 [Important change] Fix ocean threading bug seen in debug cases on Chrysalis with Intel 20.0.4. Was introduced around time of v2.0.0 tag. Does not change v2.0.0 answers on Chrysalis because those didn't use threading or debugging. [EAM] Add semi-lagrangian tracer transport for theta-l (F90 and C++), add new algorithm for finding tropopause, add DSCREAM to allow v2 and SCREAM settings in same code such as adjust_ps [EAM-MMF] 60L default, allow C++ back end of RRTMGP (EAM too). [EAMxx] add nu-top functionality, fix forcing functor, add ttype9 and dcmip2012 tests 2.1, 2.2, and 3 HOMME: remove obsolete remap algs, option to specify dynamics alg indep of tracer, new sponge layer, add imex tests [ELM] Add topography-based subgrid (topounits), add FATES-ELM Nitro., Phos. and CH4 coupling, add land-use ts for NARRM, add lulc for SSP3 RCP7, Fix nutrient fertilization exp test and carbon isotope flux, Fix xactive lnd dry deposition, add lake water storage option, fix plant hydraulics 2d params, fix carbon budget calc, fix soil nutrient conc. bug, fix mosart dam bug, add test for new ELM, MOSART features, fix bug in O3 dry dep stomatal resistances, fix plant hydraulics restart BFB error, update mkmapdata. [MOSART] fix bug for reading the latitude from an unstructured input file, fix oversat in bubble test. [MPAS-ocean] Add CFC11, CFC12 tracers, add 2D spherical transport tests, fix del4 tracer mixing, add MARBL ocean tracer mixing, modify harmonic analysis options, add GPU port of vmix routines, fix calc of ML-averaged BV freq. [MPAS-seaice] Change extents of initial polar disks for oRRS18to6v3 grid, fix ice BGC with MARBL, update spherical test cases, fix DON coupling, Remove Cf from sea ice constants. [MPAS-landice] add CRYO1850-4xCO2 compset [CIME] add GCP, ANL GCE, Spock, Perlmutter, deprecate config_compilers.xml, fix and clean-up cmake macros, fix slurm bindings, refactor CIME internal testing, cleanup SCORPIO perf data, allow position independent compset naming, [also] update v2 benchmarking suite, extend e3sm_prod with throughput and memory checks

E3SM Project, DOE↗