BioBits Health: Classroom Activities Exploring Engineering, Biology, and Human Health with Fluorescent Readouts
Not provided.
SEARCH · Search NASA
Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.
Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.
Not provided.
Explore the source record for details and available documents.
Not Available
The Landau–Zener problem, where a minimum energy separation is passed with constant rate in a two-state quantum-mechanical system, is an excellent model quantum system for a computational project. It requires a low-level computational effort, but has a number of complex numerical and algorithmic issues that can be resolved through dedicated work. It can be used to teach computational concepts, such as accuracy, discretization, and extrapolation, and it reinforces quantum concepts of time-evolution via a time-ordered product and of extrapolation to infinite time via time-dependent perturbation theory. Additionally, we discuss the concept of compression algorithms, which are employed in many advanced quantum computing strategies, and easy to illustrate with the Landau–Zener problem.
This paper describes a research-practice partnership involving twenty elementary teachers and a support team of university researchers and K-12 learning specialists. Over five years, the partnership explored ways to highlight and to expand computational thinking within math and science instruction. The project sought to increase student awareness, confidence, and fluency with computational thinking as a problem-solving approach, with particular attention to students from groups historically underrepresented in computer science. Based on feedback from across the partnership – together with analysis of student attitude and problem-solving data – this experience report identifies successes, challenges, and recommendations for future study.
Explore the source record for details and available documents.
Three independent tasks had been performed (Stetzenbach 2008, Stetzenbach 2008b, Stetzenbach 2009) to measure a variety of parameters in normative buildings across the United States. For each of these tasks 10 buildings were selected as normative indoor environments. Task 1 focused on office buildings, Task 13 focused on public schools, and Task 0606 focused on high performance buildings. To perform this task it was necessary to restructure the database for the Indoor Environmental Quality (IEQ) data and the Sound measurement as several issues were identified and resolved prior to and during the transfer of these data sets into SPSS. During overview discussions with the statistician utilized in this task it was determined that because the selection of indoor zones (1-6) was independently selected within each task; zones were not related by location across tasks. Therefore, no comparison would be valid across zones for the 30 buildings so the by location (zone) data were limited to three analysis sets of the buildings within each task. In addition, differences in collection procedures for lighting were used in Task 0606 as compared to Tasks 01 & 13 to improve sample collection. Therefore, these data sets could not be merged and compared so effects by-day data were run separately for Task 0606 and only Task 01 & 13 data were merged. Results of the statistical analysis of the IEQ parameters show statistically significant differences were found among days and zones for all tasks, although no differences were found by-day for Draft Rate data from Task 0606 (p>0.05). Thursday measurements of IEQ parameters were significantly different from Tuesday, and most Wednesday measures for all variables of Tasks 1 & 13. Data for all three days appeared to vary for Operative Temperature, whereas only Tuesday and Thursday differed for Draft Rate 1m. Although no Draft Rate measures within Task 0606 were found to significantly differ by-day, Temperature measurements for Tuesday and Thursday showed variation. Moreover, Wednesday measurements of Relative Humidity within Task 0606 varied significantly from either Tuesday or Thursday. The majority of differences in IEQ measurements by-zone were highly significant (p<0.001), with the exception of Relative Humidity in some buildings. When all task data were combined (30 buildings) neither the airborne culturable fungi nor the airborne non-culturable spore data differed in the concentrations found at any indoor location in terms of day of collection. However, the concentrations of surface-associated fungi varied among the day of collection. Specifically, there was a lower concentration of mold on Tuesday than on Wednesday, for all tasks combined. As expected, variation was found in the concentrations of both airborne culturable fungi and airborne non-culturable fungal spores between indoor zones (1-6) and the outdoor zone (zone 0). No variation was found among the indoor zones of office buildings for Task 1 in the concentrations of airborne culturable fungi. However, airborne non-culturable spores did vary among zones in one building in Task 1 and variation was noted between zones in surface-associated fungi. Due to the lack of multiple lighting measurements for Tasks 13 and 0606, by-day comparisons were only performed for Task 1. No statistical differences were observed in lighting with respect to the day of collection. There was a wide range of variability by-zone among seven of the office buildings. Although few differences were found for the brightest illumination of the worksurface (IllumWkSfcBrtst) and the darkest illumination of the worksurface (IllumWkSfcDrkst) in Task 1, there was considerable variation for these variables in Task 13 and Task 0606 (p < 0.001). Other variables that differed by-zone in Task 13 include CombCCT and AmbCCT1 for S03, S07, and S08. Additionally, AmbChromX1, CombChromY, and CombChromX varied by-zone for school buildings S02, S04, and S05, respectively. Although all tasks demonstrated significant differences in sound measurements by zone, some of the buildings within each task did not appear to differ in sound quality. Hence, post-hoc tests were not appropriate and individual zones were not compared for these buildings. It is interesting to note that sound measurements in some buildings were widely varied with most zone comparisons and other buildings varied between only a few zones.
This report is a brief summary of a project exploring LED versions of a very common luminaire type, the recessed troffer. It describes the planning and preparation for a mockup of 24 pairs of troffers in a simulated office space, where observations and comments were recorded.
The most effective mechanism to limit CO 2 release from underground Geologic Carbon Sequestration (GCS) sites over multi-century time scales will be to convert the CO 2 into solid carbonate minerals. This report describes the results from four independent research investigations on carbonate mineralization: 1) Colloidal calcite particles forming in Maramec Spring, Missouri, provide a natural analog to evaluate reactions that may occur in a leaking GCS site. The calcite crystals form as a result of physiochemical changes that occur as the spring water rises from a depth of more than 190'. The resultant pressure decrease induces a loss of CO 2 from the water, rise in pH, lowering of the solubility of Ca 2+ and CO 3 2- , and calcite precipitation. Equilibrium modelling of the spring water resulted in a calculated undersaturated state with respect to calcite. The discontinuity between the observed occurrence of calcite and the model result predicting undersaturated conditions can be explained if bicarbonate ions (HCO 3 - ) are directly involved in precipitation process rather than just carbonate ions (CO 3 2- ). 2) Sedimentary rocks in the Oronto Group of the Midcontinent Rift (MCR) system contain an abundance of labile Ca-, Mg-, and Fe-silicate minerals that will neutralize carbonic acid and provide alkaline earth ions for carbonate mineralization. One of the challenges in using MCR rocks for GCS results from their low porosity and permeability. Oronto Group samples were reacted with both CO 2 -saturated deionized water at 90°C, and a mildly acidic leachant solution in flow-through core-flooding reactor vessels at room temperature. Resulting leachate solutions often exceeded the saturation limit for calcite. Carbonate crystals were also detected in as little as six days of reaction with Oronto Group rocks at 90oC, as well as experiments with forsterite-olivine and augite, both being common minerals this sequence. The Oronto Group samples have poor reservoir rock characteristics, none ever exceeded a permeability value of 2.0 mD even after extensive dissolution of calcite cement during the experiments. The overlying Bayfield Group – Jacobsville Formation sandstones averaged 13.4 ± 4.3% porosity and a single sample tested by core-flooding revealed a permeability of ~340 mD. The high porosity-permeability characteristics of these sandstones will allow them to be used for GCS as a continuous aquifer unit with the overlying Mt. Simon Formation. 3) Anaerobic sulfate reducing bacteria (SRB) can enhance the conversion rate of CO 2 into solid minerals and thereby improve long-term storage. SRB accelerated carbonate mineralization reactions between pCO 2 values of 0.0059 and 14.7 psi. Hydrogen, lactate and formate served as suitable electron donors for SRB metabolism. The use of a 13 CO 2 spiked gas source also produced carbonate minerals with ~53% of the carbon being derived from the gas phase. The sulfate reducing activity of the microbial community was limited, however, at 20 psi pCO 2 and carbonate mineralization did not occur. Inhibition of bacterial metabolism may have resulted from the acidic conditions or CO 2 toxicity. 4) Microbialite communities forming in the high turbidity and hypersaline water of Storrs’ Lake, San Salvador Island, The Bahamas, were investigated for their distribution, mineralogy and microbial diversity. Molecular analysis of the organic mats on the microbialites indicate only a trace amount of cyanobacteria, while anaerobic and photosynthetic non-sulfur bacteria of the phyla Chloroflexi and purple sulfur bacteria of class Gammaproteobacteria were abundant.
The purpose of this course is to introduce safe hoisting and rigging practices to personnel who are attempting to become LANL incidental crane operators and to review and refresh safe hoisting and rigging practices with existing incidental crane operators.
High school students from Shelter Island High School (a small rural district on Shelter Island N.Y. nestled between the Twin Forks of Long Island) are using rotein Data Bank data to answer questions about methylenetetrahydrofolate reductase (MTHFR) (3FSU, 1ZP3), an enzyme implicated in many human diseases. Students Francesca Frasco (class of 2018), Emma Gallagher, and Lauren Gurney are part of a multi-year research class.
The target audience are incidental crane operators and riggers who will perform or support ordinary lifts.
Abstract not provided.
Explore the source record for details and available documents.
Brookhaven Lab and a local school district collaborated to develop a nanotechnology program that brings students “into” labs at Brookhaven’s Center for Functional Nanomaterials through a portable videoconferencing system.
The biggest challenge affecting lighting decisions today is future-proofing. Choices made today will likely be choices that impact the next 20 or perhaps even 40 years. For example, we can expect the best LED lighting available today to maintain 90% of initial light output for 100,000 hours or more. Compare this to a fluorescent lighting system that needs regular maintenance after only 30,000 hours due to lamp burn-outs. The simple act of choosing a LED system over a fluorescent one alone can begin to reduce life cycle costs by saving future maintenance costs. However, the choice of LED over fluorescent is just the beginning. Here, let’s look at other future-proofing decisions that should be considered when choosing your next lighting system.