Search NASA⌕ Search

SEARCH · Search NASA

Results for “CO2 cycles”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 55 records · Page 3

Development of a Large-Scale Open Geometry for Squealer Tip Coolant Injection Research

In this work, a large-scale symmetric canonical axial turbine squealer tip model is developed, which allows for the investigation of incoming gas path flow interaction with coolant flow injected into the squealer cavity. The model is developed to investigate Reynolds numbers on the order of one million for their applicability to novel supercritical CO2 cycles.

Tuite, Logan M.↗

Optimization of a Residential Air Source Heat Pump using Refrigerants with GWP <150 for Improved Performance and Reduced Emission

Using low-GWP refrigerants can reduce the Green House Gas (GHG) emission of heat pump systems. Heat exchangers and compressors are the key components and have a prominent impact on system performance, significant research is devoted to reducing the cost of the heat exchangers while achieving the same or better system performance with refrigerant charge reduction.To better understand the environmental impacts of optimized systems with low-GWP refrigerants, Life Cycle Climate Performance (LCCP) evaluation method was used to evaluate the direct and indirect emissions of the system over the course of its lifetime from manufacturing to disposal. The DOE/ORNL Heat Pump Design Model (HPDM) is used to evaluate the performance of heat pumps. Multi-objective optimizations using Particle Swarm Optimization (PSO) algorithm are performed on a 3-ton R410A residential air source heat pump on market. Seven R410A alternatives, i.e., R32, R454B, R454C, R455A, R457A, R1234yf and R1234ze(E) are investigated. The last five fluids have GWP lower than 150.As a result, 5.5%-12.8% seasonal energy efficiency ratio 2 (SEER2) improvement is achieved, and the optimized systems reduce life cycle CO2 emission by 8.5%-28.6% with GWP lower than 150 refrigerants. The optimal heat exchangers can fit into the original R410A fan-coil units; therefore, the proposed design method establishes a production and installation path to produce cost-effective low-GWP heat pumps easily accepted by end users.

Li, Zhenning↗

Conversion of Wet Waste to Sustainable Aviation Fuel and Chemical Intermediates via Catalytic Upgrading

Wet waste is a low-cost, abundant feedstock capable of displacing significant amounts of domestic petrofuel and petrochemical consumption. We present a sequential biochemical-thermochemical pathway to upgrade wet waste into hydrocarbon sustainable aviation fuel blendstock and chemical intermediates with near-zero or net-negative life-cycle CO2 emissions. Waste is initially upgraded to carboxylic acids via arrested anaerobic digestion, then catalytically converted to hydrocarbons via sequential heterogeneous catalytic ketonization, cyclization, and hydrodeoxygenation. We will discuss kinetics, durability, and reactor design of key catalytic processes, as well as applicability of final products to targeted applications.

BIOMASS FUELS,INORGANIC, ORGANIC, PHYSICAL, AND AN↗

Sustainable Aviation Fuel Grand Challenge: Tracking Metrics and Mid-2024 Dashboard

The Sustainable Aviation Fuel Grand Challenge is the result of the U.S. Department of Energy, the U.S. Department of Transportation, the U.S. Department of Agriculture, and other federal government agencies working together to develop a comprehensive strategy for scaling up new technologies to produce sustainable aviation fuels (SAF) on a commercial scale. The SAF Grand Challenge Roadmap outlines a whole-of-government approach with coordinated policies and specific activities that should be undertaken to achieve the SAF Grand Challenge goals. Progress made supporting the SAF Grand Challenge occurs when federal agencies release new funding opportunities and initiatives aligned with the SAF Grand Challenge Roadmap; provide expertise and technical assistance to industry; increase interagency collaboration; and provide data, modeling, and analysis to decision makers. To track progress on achieving the SAF Grand Challenge goals, the following four metrics have been developed: Estimated total U.S. SAF production. Estimated life cycle CO2 equivalent reductions achieved with U.S. SAF production and use. Planned production potential of SAF in the United States. Applicable research, development, demonstration, and deployment projects. SAF Grand Challenge Goal Progress

Aviation↗

Advanced Compressors for CO2-Based Power Cycles and Energy

Pumped thermal energy storage (PTES) is a cost-effective method for grid-scale, long-duration electrical energy storage (LDES). PTES uses a heat pump cycle to transfer thermal energy from a low temperature reservoir (LTR) to a high temperature reservoir (HTR), later using a heat engine cycle to reverse the process. A key component of the PTES system, the heat pump compressor, represents a significant driver to the cost, performance and operating characteristics of the PTES system. For grid-scale charging (>100 MW), traditional compressor scaling charts indicate that the operating conditions needed would be best served by a multistage axial compressor. While frame gas turbine compressors at these power ratings exist and operate at higher pressure ratios than needed for the CO2 PTES system, the inlet pressure and fluid density of this application exceed experience values. A conceptual design of a large-scale CO2 axial compressor was completed, including mean-line estimates of the compressor performance at full power conditions. The results of the conceptual design were used to refine the PTES cycle design, and updated operating conditions provided for further aero design optimization. A roughly one third scale of the first three stages of the 100 MW compressor was designed, built, and tested at relevant PTES charging conditions. Results of this test program are compared against high-resolution computational fluid dynamics models.

Compressor Heat↗

Computational Study of Mixing Solid Materials for CO2 Capture Technology

CO2 is one of the major combustion products that, once released into the air, can contribute to global climate change. Solid sorbents have been reported as promising candidates for CO2 sorbent applications due to their high CO2 absorption capacities at moderate working temperatures. By combining thermodynamic database mining with first-principles density functional theory and phonon lattice dynamics calculations, the National Energy Technology Laboratory has proposed and validated a theoretical screening methodology to identify the most promising CO2 sorbent candidates from a vast array of possible solid materials. The advantage of this method is that it identifies the thermodynamic properties of the CO2 capture reaction as a function of temperature and gas pressure without any experimental input beyond crystallographic structural information of the solid phases involved. The calculated thermodynamic properties of solid materials versus temperature and pressure changes were further used to evaluate the equilibrium properties for the CO2 adsorption/desorption cycles. The selected CO2 sorbent candidates were further considered for experimental validations. In this presentation, the results of M2O/Al2O3 (M=Li, Na, K) mixtures (MAlO2 and M5AlO4) capturing CO2 will be demonstrated in detail.

Duan, Yuhua↗

Optimization and Techno-Economic Comparison of Regenerators and Recuperators in sCO2 Recompression Brayton Cycles for Concentrating Solar Power Applications

Supercritical CO2 power cycles might be capable of providing the cost reductions and efficiency improvements necessary to reach concentrating solar power (CSP) cost targets, but require large, highly effective recuperators. Fixed-bed regenerators are a periodic heat exchanger that could be an effective yet low-cost alternative to these recuperators. This study presents a techno-economic comparison of regenerators and recuperators for a 100 MWe supercritical CO2 power cycle for CSP applications. We quantify the levelized cost of energy (LCOE) for the power plant with both types of heat exchangers, and explore sensitivity of LCOE to parameters such as CSP-specific capital costs, power cycle component capital costs, and regenerator valve replacements costs. Results indicate that the incumbent printed circuit heat exchangers achieve the lowest LCOE, unless the upper extreme of PCHE capital cost and lower extremes of regenerator and valve capital and O&M costs are realized. Sensitivity analysis also illustrates that the primary heat exchanger cost is the most influential of power cycle components, and that CSP component capital cost is more influential than power cycle capital costs. This illustrates the importance of reducing the cost of heliostats, receivers, and thermal energy storage for achieving CSP LCOE targets.

OTHER INSTRUMENTATION,SOLAR ENERGY↗

Modeling of Supercritical CO2 Shell-and-Tube Heat Exchangers Under Extreme Conditions: Part II: Heat Exchanger Model

Abstract Heat exchangers play a critical role in supercritical CO2 Brayton cycles by providing necessary waste heat recovery. Supercritical CO2 thermal cycles potentially achieve higher energy density and thermal efficiency operating at elevated temperatures and pressures. Accurate and computationally efficient estimation of heat exchanger performance metrics at these conditions is important for the design and optimization of sCO2 systems and thermal cycles. In this paper (Part II), a computationally efficient and accurate numerical model is developed to predict the performance of shell-and-tube heat exchangers (STHXs). Highly accurate correlations reported in Part I of this study are utilized to improve the accuracy of performance predictions, and the concept of volume averaging is used to abstract the geometry and reduce computation time. The numerical model is validated by comparison with computational fluid dynamics (CFD) simulations and provides high accuracy and significantly lower computation time compared to existing numerical models. A preliminary optimization study is conducted and the advantage of using supercritical CO2 as a working fluid for energy systems is demonstrated.

Engineering↗

Volumetric efficiency and pressure pulsations of a triplex reciprocating supercritical CO 2 pump

A reciprocating triplex pump has been integrated into a closed-loop supercritical carbon dioxide test facility. The pump is designed to compress liquid or supercritical carbon dioxide and has a maximum volumetric flow rate of 51 L/min. A sweep across the pump’s speed range of 100–1000 rev/min was performed with inlet conditions between 60 and 160 bar. The volumetric efficiency was found to increase as pump speed increased from 10 to 40 % before it plateaued at higher pump speeds. The mechanical efficiency increased linearly with pump speed and was not affected by system pressure. Pressure pulsations caused by the plungers and valves were also measured at each speed. Additionally, a 35-liter buffer volume, connected near the pump’s discharge was isolated at each speed to determine its effectiveness as a pulsation dampener. Overall the reciprocating pump was shown to perform exceptionally with liquid or supercritical inlet conditions applicable to many supercritical fluid applications.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Modeling of Supercritical CO2 Shell-and-Tube Heat Exchangers Under Extreme Conditions. Part I: Correlation Development

Abstract High-temperature supercritical CO2 Brayton cycles are promising possibilities for future stationary power generation and hybrid electric propulsion applications. Heat exchangers are critical components in supercritical CO2 thermal cycles and require accurate correlations and comprehensive performance modeling under extreme temperatures and pressures. In this paper (Part I), new Colburn and friction factor correlations are developed to quantify shell-side heat transfer and friction characteristics of flow within heat exchangers in the shell-and-tube configuration. Using experimental and computational fluid dynamics (CFD) data sets from existing literature, multivariate regression analysis is conducted to achieve correlations that capture the effect of multiple critical geometric parameters. These correlations offer superior accuracy and versatility as compared to previous studies and predict the thermohydraulic performance of about 90% of the existing experimental and CFD data within ±15%. Supplementary thermohydraulic performance data are acquired from CFD simulations with supercritical CO2 as working fluid to validate the developed correlations and demonstrate its capability to be applied to supercrtical CO2 heat exchangers.

Engineering↗

ENVIRONMENTAL DEGRADATION OF HARD AND SOFT MAGNETIC MATERIALS IN GASEOUS AND SUPERCRITICAL CO2 ENVIRONMENTS

It may be beneficial to use hermetic designs for supercritical CO2 (sCO2) cycles machinery as they would eliminate CO2 leakage through shaft end seals. This would reduce CO2 emissions and operating costs for makeup of lost process fluid. Those designs may replace traditional oil-lubricated bearings with actively controlled magnetic bearings operating at high temperatures in the process fluid environment (to reduce the need for active cooling). This paper investigates the material degradation of various types of magnets in CO2. Included are several permanent and soft magnetic materials (Alnico 9C, Alnico 5-7C, and 18-T550 grade SmCo, and Hiperco 50) with or without coatings (nickel plating or C5 coating). The materials were exposed to: (1) flowing gaseous CO2 at 1,022 °F (550 °C) and atmospheric pressure in a furnace and (2) sCO2 at 842 °F (450 °C) and 1,500 psi (103 bar) in an autoclave. The preliminary mass change measured after total exposures of 1,000 hours and 2,000 hours are included.

supercritical CO2, magnetic material↗

Modeling a Water-Cooled Printed Circuit Heat Exchanger Condensing CO2 for use in SCO2 Cycle System Optimization Studies

This work describes a one-dimensional model of a water-cooled printed circuit heat exchanger (PCHE) condensing supercritical CO2. The model is developed for use in cycle optimization studies (e.g., minimizing levelized cost of electricity) as either the main heat rejection cooler and/or a compressor intercooler for recompression closed Brayton supercritical CO2 power cycles. Sensitivity and case studies are used to illustrate the impact of important model parameters, and this includes allowing for independent variation of zig-zag channel wave angles on the CO2 and water side. Results show that for a given CO2 design pressure (and thus saturation temperature), the PCHE design inlet water temperature has a significant impact on the PCHE size. Results also demonstrate that if wave angles are the same on the CO2 and water side, the water side pressure drop will have more influence on determining the optimum PCHE mass than the CO2 side pressure drop. Reducing the water side wave angle to near straight channel flow offers a more compact design for a similar water side pressure drop (and pump power requirement). Cases are also shown for further increasing the compactness and how the PCHE mass is affected along with water pump power.

Liese, Eric↗

Impact of Dry Cooler Air-Side Performance on a sCO2 Power Cycle for a CSP Application

Uncertainty around the design and control of the supercritical CO2 power cycle must be reduced before this technology can be implemented for large-scale grid support. To better understand the day-to-day performance of an sCO2 cycle, off-design performance calculations must be included for all power block components, and performance assumptions must be removed. This study has expanded the modeled scope to include the air-side performance for the dry cooler and has incorporated discretized heat transfer calculations for both streams through the pre-cooler to better predict off-design performance. This study considered a recompression Brayton cycle in a concentrating solar power application. The cycle model utilized fixed sCO2 turbomachinery maps for the main compressor, recompressor, and expander operating to supply approximately 10 MW gross at the design point. Fixed vendor-supplied fan curves were used to calculate the air-side performance of the dry cooler. The primary heater was modeled considering both the sCO2 and heat transfer fluid streams. Off-design performance was predicted for an ambient temperature range of 0-55℃, a HTF temperature range of 705-735℃, and a HTF mass flow range of 50-105% of the design point value. To understand the importance of modeling the air-side performance, the cycle off-design performance was also calculated using a constant CO2 outlet temperature assumption and a constant approach temperature assumption for the dry cooler. Results show that using these assumptions can significantly alter the power output and cycle efficiency predictions.

14 SOLAR ENERGY↗