Search NASA⌕ Search

SEARCH · Search NASA

Results for “COLLECTOR”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 55 records · Page 3

Shape Control of Solar Collectors Using Shape Memory Alloy Actuators

Solar collectors that are focused on a central receiver are designed with a mechanism for defocusing the collector or disabling it by turning it out of the path of the sun's rays. This is required to avoid damaging the receiver during periods of inoperability. In either of these two cases a fail-safe operation is very desirable where during power outages the collector passively goes to its defocused or deactivated state. This paper is principally concerned with focusing and defocusing the collector in a fail-safe manner using shape memory alloy actuators. Shape memory alloys are well suited to this application in that once calibrated the actuators can be operated in an on/off mode using a minimal amount of electric power. Also, in contrast to other smart materials that were investigated for this application, shape memory alloys are capable of providing enough stroke at the appropriate force levels to focus the collector. Design and analysis details presented, along with comparisons to test data taken from an actual prototype, demonstrate that the collector can be repeatedly focused and defocused within accuracies required by typical solar energy systems. In this paper the design, analysis and testing of a solar collector which is deformed into its desired shape by shape memory alloy actuators is presented. Computations indicate collector shapes much closer to spherical and with smaller focal lengths can be achieved by moving the actuators inward to a radius of approximately 6 inches. This would require actuators with considerably more stroke and some alternate SMA actuators are currently under consideration. Whatever SMA actuator is finally chosen for this application, repeatability and fatigue tests will be required to investigate the long term performance of the actuator.

Lobitz, D. W.↗

Overall Traveling-Wave-Tube Efficiency Improved By Optimized Multistage Depressed Collector Design

Depressed Collector Design The microwave traveling wave tube (TWT) is used widely for space communications and high-power airborne transmitting sources. One of the most important features in designing a TWT is overall efficiency. Yet, overall TWT efficiency is strongly dependent on the efficiency of the electron beam collector, particularly for high values of collector efficiency. For these reasons, the NASA Glenn Research Center developed an optimization algorithm based on simulated annealing to quickly design highly efficient multistage depressed collectors (MDC's). Simulated annealing is a strategy for solving highly nonlinear combinatorial optimization problems. Its major advantage over other methods is its ability to avoid becoming trapped in local minima. Simulated annealing is based on an analogy to statistical thermodynamics, specifically the physical process of annealing: heating a material to a temperature that permits many atomic rearrangements and then cooling it carefully and slowly, until it freezes into a strong, minimum-energy crystalline structure. This minimum energy crystal corresponds to the optimal solution of a mathematical optimization problem. The TWT used as a baseline for optimization was the 32-GHz, 10-W, helical TWT developed for the Cassini mission to Saturn. The method of collector analysis and design used was a 2-1/2-dimensional computational procedure that employs two types of codes, a large signal analysis code and an electron trajectory code. The large signal analysis code produces the spatial, energetic, and temporal distributions of the spent beam entering the MDC. An electron trajectory code uses the resultant data to perform the actual collector analysis. The MDC was optimized for maximum MDC efficiency and minimum final kinetic energy of all collected electrons (to reduce heat transfer). The preceding figure shows the geometric and electrical configuration of an optimized collector with an efficiency of 93.8 percent. The results show the improvement in collector efficiency from 89.7 to 93.8 percent, resulting in an increase of three overall efficiency points. In addition, the time to design a highly efficient MDC was reduced from a month to a few days. All work was done in-house at Glenn for the High Rate Data Delivery Program. Future plans include optimizing the MDC and TWT interaction circuit in tandem to further improve overall TWT efficiency.

Vaden, Karl R.↗

A lightweight and metal-free current collector for battery anode applications

The requirement for high energy density batteries is driving the development of high-capacity electrode materials while reducing the amount of inactive battery components such as separators, binders, and current collectors. Though current collectors are an inactive component, they are still required for successful working of a battery cell. Conventional current collectors include aluminum foil for cathode and copper foil for anode. Copper foil is quite heavy (8.7 mg/cm 2 ) for 10μm thickness. Therefore, there is a need for a lightweight current collector for anode applications. In this work, a metal-free current collector comprised of aligned carbon fiber (CFs) layer filled with carbon nanotubes (CNTs) mixed in polymer (P) is developed to be used as a current collector for anodes. Further, anodes coated on the CF-CNT-P showed lower charge transfer resistance and improved rate capability compared with the anodes fabricated on conventional copper foil-based current collectors. The CF-CNT-P are lighter (≈1.5 mg/cm 2 ) than the commonly used copper foil (8.7 mg/cm 2 ), which will increase the gravimetric energy density.

25 ENERGY STORAGE↗

Influence of Correlations on the Thermal Performance Modeling of Parabolic Trough Collectors

The influence of correlations on the thermal performance modeling of parabolic trough collectors was analyzed in this work. A versatile model for a parabolic trough collector was developed that allows one- and two-dimensional analysis and enables the use of correlations to calculate thermophysical properties and convection heat transfer coefficients. The model also allows the use of constant values for properties and/or coefficients obtained from the evaluation correlations at a specific temperature. The effect of each correlation was evaluated independently, and the results were compared with a reference case that considered a two-dimensional approach and used all the correlations. For the analyzed cases, the correlation for the absorber emittance has the strongest impact on the collector efficiency, leading to a lower error when used. Based on the results, a one-dimensional model approach considering a correlation for the absorber emittance leads to efficiency errors below 3% for collector lengths of up to 243.6 m. Compared with the reference case, a one-dimensional approach using all correlations for a collector with a length of 500 m, and operating with an inlet temperature of 773 K, can result in errors around 9%. However, using constant values for properties and heat transfer coefficients could lead to errors of up to 50%. Multiple thermal models for parabolic trough collectors proposed in the literature rely on a one-dimensional approach, estimated values for the heat transfer coefficients, and constant thermophysical properties. The errors associated with those approaches are analyzed and quantified in this work as a function of the collector length and operation temperature.

absorber emittance↗

Beneficiation of Bastnaesite Ore with New Flotation Collector Ligands

Interest in Rare Earth Elements (REEs) has increased due to their distinct properties and new applications. China currently has a monopoly on rare earth production due to the lack of an economically viable process used outside of China. Bastnaesite, a rare earth fluorocarbonate, is one of the most common minerals containing REEs, which is mostly comprised of cerium and other light REEs. The objective of this research is to find a novel collector for the beneficiation of bastnaesite through froth flotation experiments to increase the grade and recovery of rare earth oxides while rejecting the major gangue minerals. Microflotation and rougher bench flotation studies were evaluated to find optimal collector(s) from 19 possible candidates. Collectors 2, 5, and 8 were the top performing collectors chosen from microflotation experiments. A design of experiment matrix was set up to evaluate the variables, variable interactions, and provide a reference matrix for future optimization studies. Collector 2 was assessed to be the optimal collector. A rougher flotation experiment produced a rare earth oxide grade and recovery of 41% and 78%, respectively with a 91.5% rejection of calcite. Collector 8 and 14 also showed promising results to replace fatty acid. As such, this patent pending technology can serve to provide a pathway for efficient domestic REE production.

36 MATERIALS SCIENCE↗

A high performance porous flat-plate solar collector

A solar collector employing a porous matrix as a solar absorber and heat exchanger is presented and its application in solar air heaters is discussed. The collector is composed of a metallic matrix with a porous surface which acts as a large set of cavity radiators; cold air flows through the matrix plate and exchanges heat with the thermally stratified layers of the matrix. A steady-state thermal analysis of the collector is used to determine collector temperature distributions for the cases of an opaque surface matrix with total absorption of solar energy at the surface, and a diathermanous matrix with successive solar energy absorption at each depth. The theoretical performance of the porous flat plate collector is shown to exceed greatly that of a solid flat plate collector using air as the working medium for any given set of operational conditions. An experimental collector constructed using commercially available, low cost steel wool as the matrix has been found to have thermal efficiencies from 73 to 86%.

Lansing, F. L.↗

Flotation of Bastnaesite Ore Using Novel Collectors

Interest in rare earth elements (REEs) has increased due to their distinct properties and new applications. China currently has a monopoly on rare earth production due to the lack of an economically viable process used outside of China. Bastnaesite, a rare earth fluorocarbonate, is one of the most common minerals containing REEs, which is mostly comprised of cerium and other light REEs. The objective of this research is to find a novel collector for the beneficiation of bastnaesite through froth flotation experiments to increase the grade and recovery of rare earth oxides while rejecting the major gangue minerals. Microflotation and rougher bench flotation studies were evaluated to find optimal collector(s) from 19 possible candidates. Collector 2, 5, and 8 were the top performing collectors chosen from microflotation experiments. A design of experiment matrix was set up to evaluate the variables, variable interactions and provide a reverence matrix for future optimization studies. Collector 2 was assessed to be the optimal collector. A rougher flotation experiment produced a rare earth oxide grade and recovery of 41% and 78% respectively and a 91.5% rejection of calcite. Collector 8 and 14 also showed promising results in replace fatty acid.

Everly, Dylan↗

Method of coating an electrical current collector and electrodes resulting therefrom

The present invention is directed to a method of coating an electrical current collector comprising treating a portion of a surface of the electrical current collector with an adhesion promoting composition to deposit a treatment layer over the portion of the surface of the electrical current collector, wherein the resulting surface of the electrical current collector comprises (a) a treated portion comprising the treatment layer and (b) a non-treated portion that lacks the treatment layer; electrodepositing an electrodeposited coating layer from an electrodepositable coating composition onto the surface of the electrical current collector to form a coated electrical current collector; and rinsing the coated electrical current collector, wherein the electrodeposited coating layer substantially adheres to the treated portion of the surface and does not adhere to the non-treated portion of the surface. Also disclosed are electrodes and electrical storage devices.

Oakes, Landon J.↗

Aligned carbon fibers-carbon nanotube-polymer-based composite as lithium-ion battery current collector

High energy density demand is pushing the development of high-voltage cathode materials, which necessitates improved electrochemical stability of other battery components such as binders, electrolytes, and current collectors. Current collectors are considered to be an inactive component but still play an essential role. In this study, a metal-free composite film containing directionally aligned carbon fiber (CF), carbon nanotube (CNT), and polymer (P) was developed to replace aluminum foil as a cathode current collector, which relies on forming an Al 2 O 3 layer to ensure electrochemical stability at high voltage. Here, each component in the new cathode current collector played a functional role. The CNTs provided uniform current densities, and CFs improved the electronic conductivity and mechanical strength of the composite material. The polymer enhanced the adhesion of the cathode coating with the current collector and provided an impervious support to the cathode materials. The CF-CNT-P composite demonstrated excellent electrochemical and thermal stability. Cathodes coated on the CF-CNT-P composite exhibited lower charge transfer resistance, improved rate capability, and improved cyclic stability compared with the cathodes deposited on conventional aluminum foil. Additionally, the composite current collector was lighter (1.81 mg/cm 2 and 15 µm thick) than the commonly used aluminum foil (4.35 mg/cm2 and 15 µm thick), which can increase the cell energy density. Additionally, the CF-CNT-P did not need to be separated from the cathode coating during recycling and can be burnt out with binder, simplifying the recycling process.

25 ENERGY STORAGE↗

Wind Loading on Parabolic Trough Collectors: Wind and Structural Loads Measurements at an Operational Powerplant

Concentrated Solar Power (CSP) is a promising method for using solar power for electricity generation with thermal energy storage for industrial applications. Solar collectors constitute almost 1/3 of the total cost of the power plant. One of the primary drivers of unrealiability of these collectors is wind-driven loading of mirrors, support structures, and drives. To date, the design of the solar collector structures has relied on data from wind tunnels that do not adequately capture the dynamic effects observed at scale. NREL initiated a field measurement campaign at the operational Nevada Solar One (NSO) parabolic trough powerplant. At this plant, parabolic trough solar collectors track the sun from east to west in the course of a day and face varying wind loads depending on the wind properties and the angle of the troughs. The aim of the project is a detailed characterization of prevailing wind and turbulence conditions and resulting operational loads on parabolic troughs, providing insights into structural dynamic response, and generating a comprehensive wind-loading dataset for validating simulations of wind loading on collector structures. The measurements at NSO consist of sonic anemometers on masts at different heights to characterize the incoming flow and conditions at four trough rows at the edge of the trough field. In addition, a Doppler Lidar scans the horizontal plane above the troughs. The wind measurements at NSO have been continuously collecting data since October 2021 and are combined with structural load measurements that started in November 2022. The load measurements were installed on the same four outermost trough rows and include support structure bending moments, drive torque moments, dynamic accelerations of the spaceframe, mirror displacement, and tilt angles. Measurements are planned to continue until May 2023, providing a first-of-a-kind, high-resolution multi-month dataset of combined wind and load measurements. In this presentation, we show first results of the measurement campaign. Based on the measurements, we identified three main factors altering the flow over the parabolic troughs: Wind speed, wind direction, and the angle of the parabolic troughs. Most interactions between incoming wind and the trough field are observed when the wind blows perpendicular to the trough rows. In this case, the first rows experience the highest wind speed and block the downwind rows, creating conditions with decreased wind speed and enhanced turbulence within the trough field. Also, turbulent length scales are smaller after the first row. This leads to the highest static loads (bending and torque moments) at the first row but potentially increased dynamic loads within the field. We illustrate our findings with case studies focused on different wind conditions and will present fatigue analysis to highlight the impact of wind-driven loads on collector structures.

CSP collectors↗

Computational and Experimental Validation of Fractal-Fin, Dimpled Solar Heat Collector

A 3 foot x 3 foot x 3 foot aluminum solar collector was manufactured using computer numerical control. The interior of the device included six triangular dimpled fins for enhanced heat transfer. The interior vertical wall on the south side was also dimpled. The solar collector working fluid was based on water, and the collector consisted solely of passive heat transfer mechanisms (no moving parts), making it ideal for off-the-grid and rural applications. Two types of heat transfer experiments were conducted. One experiment had external flat heaters attached on the top and the front side, while the other four sides were insulated. Except for the bottom surface, the second experiment had all its exterior surfaces sprayed with black solar paint to collect as much solar heat as possible. Temperature data as a function of time was collected using 14 thermocouples spread strategically throughout the solar collector. In addition, computational fluid dynamics (CFD) simulations were conducted using the dynamic Smagorinsky large eddy simulation turbulence model. The first simulation considered that both the top and front surfaces were exposed to a fixed temperature of 313.7 K (105 °F), while the remaining four surfaces were insulated. For the second simulation, all conditions were the same, except that the temperature for both heated surfaces was raised to 350 K (170.3 °F). The two temperatures are expected to bound the solar collector operational temperature during the late- Spring, Summer, and early-Fall months. The solar collector design, experimental data, CFD output, and a discussion of five manufacturing approaches and costs are documented in this report.

14 SOLAR ENERGY↗

Fractal-Fin, Dimpled Solar Heat Collector with Solar Glaze

Exterior solar glaze was added to a 3 foot x 3 foot x 3 foot aluminum solar collector that had six triangular dimpled fins for enhanced heat transfer. The interior vertical wall on the south side was also dimpled. The solar glaze was added to compare its solar collection performance with unglazed solar collector experiments conducted at Sandia in 2021. The east, west, front, and top sides of the solar collector were encased with solar glaze glass. Because the solar incident heat on the north and bottom sides was minimal, they were insulated to retain the heat that was collected by the other four sides. The advantages of the solar glaze include the entrapment of more solar heat, as well as insulation from the wind. The disadvantages are that it increases the cost of the solar collector and has fragile structural properties when compared to the aluminum walls. Nevertheless, prior to conducting experiments with the glazed solar collector, it was not clear if the benefits outweighed the disadvantages. These issues are addressed herein, with the conclusion that the additional amount of heat collected by the glaze justifies the additional cost. The solar collector glaze design, experimental data, and costs and benefits are documented in this report.

14 SOLAR ENERGY↗

A generalized correlation of experimental flat-plate collector performance

A generalized collector performance correlation was derived and shown by experimental verification to be of the proper form to account for the majority of the variable conditions encountered both in outdoor and in indoor collector tests. This correlation permits a determination of collector parameters which are essentially nonvarying under conditions which do vary randomly (outdoors) or conditions which vary in a controlled manner (indoors - simulator). It was shown that correlation of the experimental performance of collectors allows the following: (1) comparisons of different collector designs; (2) collector performance prediction under conditions that differ from the conditions of the test program; and (3) monitoring performance degradation effects.

Simon, F. F.↗

Design, fabrication, testing and delivery of a solar collector

A two phase program encompassing the redesign and fabrication of a solar collector which is low in cost and aesthetically appealing is described. Phase one work reviewed the current collector design and developed a low-cost design based on specific design/performance/cost requirements. Throughout this phase selected collector component materials were evaluated by testing and by considering cost, installation, maintainability and durability. The resultant collector design was composed of an absorber plate, insulation, frame, cover, desiccant and sealant. In Phase two, three collector prototypes were fabricated and evaluated for both nonthermal and thermal characteristics. Tests included static load tests of covers, burst pressure tests of absorber plates, and tests for optical characteristics of selective absorber plate coatings. The three prototype collectors were shipped to Marshall Space Flight Center for use in their solar heating and cooling test facility.

Sims, W. H.↗

Evaluation of initial collector field performance at the Langley Solar Building Test Facility

The thermal performance of the solar collector field for the NASA Langley Solar Building Test Facility is given for October 1976 through January 1977. A 1,180 square meter solar collector field with seven collector designs helped to provide hot water for the building heating system and absorption air conditioner. The collectors were arranged in 12 rows with nominally 51 collectors per row. Heat transfer rates for each row were calculated and recorded along with sensor, insolation, and weather data every five minutes using a minicomputer. The agreement between the experimental and predicted collector efficiencies was generally within five percentage points.

Boyle, R. J.↗

Thermal performance of MSFC hot air collectors under natural and simulated conditions

The procedures used and the results obtained from an evaluation test program conducted to determine the thermal performance and structural characteristics of selected MSFC--designed hot air collectors under both real and simulated environmental conditions are described. Five collectors were tested in the three phased program. A series of outdoor tests were conducted to determine stagnation temperatures on a typical bright day and to determine each collector's ability to withstand these temperatures. Two of the collectors experienced structural deformation sufficient to eliminate them from the remainder of the test program. A series of outdoor tests to evaluate the thermal performance of collector S/N 10 under certain test conditions were performed followed by a series of indoor tests to evaluate the thermal performance of the collector under closely controlled simulated conditions.

Shih, K., Sr.↗

Evaluation of initial collector field performance at the Langley Solar Building Test Facility

The thermal performance of the solar collector field for the NASA Langley Solar Building Test Facility is given for October 1976 through January 1977. An 1180 square meter solar collector field with seven collector designs helped to provide hot water for the building heating system and absorption air conditioner. The collectors were arranged in 12 rows with nominally 51 collectors per row. Heat transfer rates for each row are calculated and recorded along with sensor, insolation, and weather data every 5 minutes using a mini-computer. The agreement between the experimental and predicted collector efficiencies was generally within five percentage points.

Boyle, R. J.↗

Multistage depressed collector with efficiency of 90 to 94 percent for operation of a dual-mode traveling wave tube in the linear region

An axisymmetric, multistage, depressed collector of fixed geometric design was evaluated in conjunction with an octave bandwidth, dual mode traveling wave tube (TWT). The TWT was operated over a wide range of conditions to simulate different applications. The collector performance was optimized (within the constraint of fixed geometric design) over the range of TWT operating conditions covered. For operation of the TWT in the linear, low distortion range, 90 percent and greater collector efficiencies were obtained leading to TWT overall efficiencies of 20 to 35 percent, as compared with 2 to 5 percent with an undepressed collector. With collectors of this efficiency and minimized beam interception losses, it becomes practical to design dual mode TWT's such that the low mode can represent operation well below saturation. Consequently, the required pulse up in beam current can be reduced or eliminated, and this mitigates beam control and dual mode TWT circuit design problems. For operation of the dual mode TWT at saturation, average collector efficiencies in excess of 85 percent were obtained for both the low and high modes across an octave bandwidth, leading to a three to fourfold increase in the TWT overall efficiency.

Ramins, P.↗