Search NASA⌕ Search

SEARCH · Search NASA

Results for “COMPACT COMMISSIONS”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 55 records · Page 3

OPERA experiment and its releted emulsion techniques

The OPERA experiment is designed to clarify neutrino oscillation by detecting appearance of {nu}{sub {tau}} in pure {nu}{sub {mu}} beam through a long baseline method (CNGS beam from cern to the Gran Sasso laboratory). The key technique is the use of emulsion films and their scanning. We developed a new high speed scanning system with speed of 50 cm{sup 2}/h and it was successfully demonstrated in 2006 CNGS commissioning. The new scanning system is not only meant for the OPERA experiment, but it has large potential of applications. For example, measurement of {nu}{sub e} with strong separation power against {pi}{sup 0}. Or a compact emulsion spectrometer for future neutrino experiments.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Design, construction, and characterization of a compact DD neutron generator designed for 40Ar/39Ar geochronology

A next-generation, high-flux DD neutron generator has been designed, commissioned, and characterized, and is now operational in a new facility at the University of California Berkeley. The generator, originally designed for 40 Ar/ 39 Ar dating of geological materials, has since served numerous additional applications, including medical isotope production studies, with others planned for the near future. In this work, we present an overview of the High Flux Neutron Generator (HFNG) which includes a variety of simulations, analytical models, and experimental validation of results. Extensive analysis was performed in order to characterize the neutron yield, flux, and energy distribution at specific locations where samples may be loaded for irradiation. A notable design feature of the HFNG is the possibility for sample irradiation internal to the cathode, just 8 mm away from the neutron production site, thus maximizing the neutron flux (n/cm 2 /s). The generator’s maximum neutron flux at this irradiation position is 2.58 x 10 7 n/cm 2 /s ± 5% (approximately 3 x 10 8 n/s total yield) as measured via activation of small natural indium foils. However, future development is aimed at achieving an order of magnitude increase in flux. Additionally, the deuterium ion beam optics were optimized by simulations for various extraction configurations in order to achieve a uniform neutron flux distribution and an acceptable heat load. Finally, experiments were performed in order to benchmark the modeling and characterization of the HFNG.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

COMMISSIONING AND FIRST RESULTS FROM CHANNELING RADIATION AT FAST

X-rays have widespread applications in science and industry, but developing a simple, compact, and high-quality X-ray source remains a challenge. Our collaboration has explored the possible use of channeling radiation driven by a 50 MeV low-emittance electron beam to produce narrowband hard X-rays with photon energy of 40 to 140 keV [8,9,11]. Here we present the simulated X-ray spectra including the background bremsstrahlung contribution, and a description of the required optimization of the relevant electron-beam parameters necessary to maximize brilliance of the resulting X-ray beam. Results are presented from our test of this, carried out at the Fermilab Accelerator Science & Technology (FAST) facility’s 50-MeV low-energy electron injector. As a result of the beam parameters, made possible by the photo-injector based SRF linac, the average brilliance at FAST was expected to be about one order of magnitude higher than that in previous experiments.

43 PARTICLE ACCELERATORS↗

Modeling of injected current stream-induced 3D perturbations in local helicity injection plasmas

Solenoid-free tokamak startup techniques are essential for spherical tokamaks and offer a pathway to cost reduction and design simplification in fusion energy systems. Local helicity injection (LHI) is one such approach, employing compact edge current sources to drive open field line current that initiates and sustains tokamak plasmas. The recently commissioned Pegasus-III Experiment provides a platform for advancing this and other solenoid-free startup methods. This study investigates the effect of LHI on magnetic topology in Pegasus-III plasmas. A helical filament model represents the injected current, and the linear plasma response to its three-dimensional field is calculated with M3D-C1. Poincaré mapping reveals substantial flux surface degradation in all modeled cases. The onset of overlapping magnetic structures and large-scale surface deformation begins near Ψ N ≈ 0.37, indicating a broad region of perturbed topology extending toward the edge. In rotating plasmas, both single-fluid and two-fluid models exhibit partial screening of the n = 1 perturbation, with two-fluid calculations showing stronger suppression near the edge. In contrast, the absence of rotation leads to strong resonant field amplification in the single-fluid case, while the two-fluid case with zero electron rotation mitigates this amplification and preserves edge screening. Magnetic probe measurements indicate that modeling the stream with spatial spreading—representing distributed current and/or oscillatory motion—better reproduces measured magnetic power profiles than a rigid filament model. The results underscore the role of rotation and two-fluid physics in screening stream perturbations and point to plasma flow measurements and refined stream models as key steps toward improving predictive fidelity.

Schaefer, Carolyn E. [Univ. of Wisconsin, Madison,↗

A compact tunable quadrupole lens for brighter and sharper ultra-fast electron diffraction imaging

In this article, we report our proof-of-principle design and experimental commissioning of a broadly tunable and low-cost transverse focusing lens system for MeV-energy electron beams. The lens system based on electromagnetic (EM) quadrupoles has been built as a part of the existing instrument for ultra-fast electron diffraction (UED) experiments at the Accelerator Test Facility II (ATF-II) at Brookhaven National Laboratory (BNL). We experimentally demonstrated the independent control of the size and divergence of the beam with the charge ranging from 1 to 13 pC. The charge density and divergence of the beam at the sample are the most important factors determining the quality of the Bragg-diffraction image (BDI). By applying the Robust Conjugate Directional Search (RCDS) algorithm for online optimization of the quadrupoles, the transverse beam size can be kept constant down to 75 µm from 1 to 13 pC. The charge density is nearly two orders of magnitude higher than the previously achieved value using a conventional solenoid. Using the BDI method we were able to extract the divergence of the beam in real-time and apply it to the emittance measurement for the first time. Our results agree well with simulations and with the traditional quadrupole scan method. The real-time divergence measurement opens the possibility of online optimization of the beam divergence (< 0.2 mrad) at the sample with the increased beam charge. This optimization is crucial for the future development of single-shot ultra-fast electron microscope (UEM). Finally, we demonstrated BDI with significant improvement, up to 3 times higher peak intensity and 2 times sharper Bragg-diffraction peaks at 13 pC. The charge is now limited by the laser power and increasing charge may improve the quality of BDI further. The capability we demonstrated here provides us with opportunities for new sciences using near-parallel, bright and ultrafast electron beams for single-shot imaging, to directly visualize the dynamics of defects and nanostructured materials, or even record molecular movie, which are impossible using present electron-beam technologies.

43 PARTICLE ACCELERATORS↗

Study of beam loading and its compensation in the Compact Ultrafast Terahertz Free-Electron Laser injector linac

The RF properties of an accelerating structure, and the pulse structure and charge per bunch in the electron beam propagating through it are important parameters that determine the impact of beam loading in the structure. The injector linac of the Compact Ultrafast Terahertz Free-Electron Laser (CUTE-FEL) has been operated with two different pulse structures during initial commissioning experiments and the effect of beam loading on the accelerated electron beam parameters has been studied analytically for these two pulse structures. This paper discusses the analytical study of beam loading in a Standing Wave, Plane Wave Transformer linac employed in the CUTE-FEL setup, and a possible technique for its compensation for the electron beam parameters of the CUTE-FEL. A parametric study has been performed to study beam loading for different beam currents and to optimize injection time of the electron beam to compensate beam loading. Results from the parametric study have also been used to explain previously observed results from acceleration experiments in the CUTE-FEL setup.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

National Synchrotron Light Source II storage ring vacuum systems

The National Synchrotron Light Source II, completed in 2014, is a 3-GeV synchrotron radiation (SR) facility at Brookhaven National Laboratory and has been in steady operation since. With a design electron current of 500 mA and subnanometer radians horizontal emittance, this 792-m circumference storage ring is providing the highest flux and brightness x-ray beam for SR users. The majority of the storage ring vacuum chambers are made of extruded aluminium. Chamber sections are interconnected using low-impedance radiofrequency shielded bellows. SR from the bending magnets is intercepted by water-cooled compact photon absorbers resided in the storage ring chambers. This paper presents the design of the storage ring vacuum system, the fabrication of vacuum chambers and other hardware, the installation, the commissioning, and the continuing beam conditioning of the vacuum systems.

43 PARTICLE ACCELERATORS↗

A new neutral particle analyzer diagnostic and its first commissioning on HL-2A

A new neutral particle analyzer diagnostic has been developed for HuanLiuqi-2A (commonly referred to as HL-2A), which can provide the neutral particle flux measurement along 11 separate sightlines, simultaneously, within a wider energy range (1-70 keV). It is an electrostatic type analyzer with a removable pinhole and special-shape condenser. The energy analysis can be flexibly achieved by controlling a preset stepwise high voltage on the condenser. It is compact and its field of view covers HL-2A cross section from -33 cm to 33 cm without 'cross-talk.' The energy spectra and ion temperature profile have been obtained during its commissioning.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Spectra of clinical CT scanners using a portable Compton spectrometer

Purpose: Spectral information of the output of x-ray tubes in (dual source) computer tomography (CT) scanners can be used to improve the conversion of CT numbers to proton stopping power and can be used to advantage in CT scanner quality assurance. The purpose of this study is to design, validate, and apply a compact portable Compton spectrometer that was constructed to accurately measure x-ray spectra of CT scanners. Methods: In the design of the Compton spectrometer, the shielding materials were carefully chosen and positioned to reduce background by x-ray fluorescence from the materials used. The spectrum of Compton scattered x-rays alters from the original source spectrum due to various physical processes. Reconstruction of the original x-ray spectrum from the Compton scattered spectrum is based on Monte Carlo simulations of the processes involved. This reconstruction is validated by comparing directly and indirectly measured spectra of a mobile x-ray tube. The Compton spectrometer is assessed in a clinical setting by measuring x-ray spectra at various tube voltages of three different medical CT scanner x-ray tubes. Results: The directly and indirectly measured spectra are in good agreement (their ratio being 0.99) thereby validating the reconstruction method. The measured spectra of the medical CT scanners are consistent with theoretical spectra and spectra obtained from the x-ray tube manufacturer. Conclusions: A Compton spectrometer has been successfully designed, constructed, validated, and applied in the measurement of x-ray spectra of CT scanners. These measurements show that our compact Compton spectrometer can be rapidly set-up using the alignment lasers of the CT scanner, thereby enabling its use in commissioning, troubleshooting, and, e.g., annual performance check-ups of CT scanners.

07 ISOTOPE AND RADIATION SOURCES↗

A low-voltage retarding-field Mott polarimeter for photocathode characterization

Nuclear physics experiments at Thomas Jefferson National Accelerator Facility's CEBAF rely on high polarization electron beams. We describe a recently commissioned system for prequalifying and studying photocathodes for CEBAF with a load-locked, low-voltage polarized electron source coupled to a compact retarding-field Mott polarimeter. The polarimeter uses simplified electrode structures and operates from 5 to 30 kV. The effective Sherman function for this device has been calibrated by comparison with the CEBAF 5 MeV Mott polarimeter. For elastic scattering from a thick gold target at 20 keV, the effective Sherman function is 0.201(5). Its maximum efficiency at 20 keV, defined as the detected count rate divided by the incident particle current, is 5.4(2)×10 -4 , yielding a figure-of-merit, or analyzing power squared times efficiency, of 1.0(1)×10 -5 . The operating parameters of this new polarimeter design are compared to previously published data for other compact Mott polarimeters of the retarding-field type.

43 PARTICLE ACCELERATORS↗

Accelerator Physics Lessons From CBETA, the First Multi-turn SRF ERL

The Cornell-BNL ERL Test Accelerator (CBETA) has been designed, constructed, and commissioned in a collaboration between Cornell and Brookhaven National Laboratory (BNL). It focuses on energy-saving measures in accelerators, including permanent magnets, energy recovery, and superconductors; it has thus been referred to as a green accelerator. CBETA has become the world's first Energy Recovery Linac (ERL) that accelerates through multiple turns and then recovers the energy in superconducting radiofrequency (SRF) cavities though multiple decelerating turns. The energy is then available to accelerate more beam. It has also become the first accelerator that operates 7 beams in the same large-energy aperture Fixed Field Alternating-gradient (FFA) lattice. The FFA is constructed of permanent combined function magnets and transports energies of 42, 78, 114, and 150 MeV simultaneously. Accelerator physics lessons from the commissioning period will be described and applications of such an accelerator from hadron cooling to EUV lithography and from nuclear physics to a compact Compton source will be discussed.

Deitrick, K. E.↗

Deuteron injector for Peking University Neutron Imaging Facility project

The deuteron injector developed for the PKUNIFTY (Peking University Neutron Imaging Facility) has been installed and commissioned at Peking University (PKU). The injector system must transfer 50 keV 50 mA of D{sup +} ion beam to the entrance of the 2 MeV radio frequency quadrupole (RFQ) with 10% duty factor (1 ms, 100 Hz). A compact 2.45 GHz permanent magnet electron cyclotron resonance (PMECR) ion source and a 1.36 m long low energy beam transport (LEBT) line using two solenoids was developed as the deuteron injector. A {phi}5 mm four-quadrant diaphragm was used to simulate the entrance of RFQ electrodes. The beam parameters are measured after this core with an emittance measurement unit (EMU) and a bending magnet for ion fraction analysis at the end of injector. During the commissioning, 77 mA of total deuteron beam was extracted from PMECR and 56 mA of pure D{sup +} beam that passed through the {phi}5 mm four-quadrant diaphragm was obtained at the position of RFQ entrance with the measured normalized rms emittance 0.12-0.16{pi} mm mrad. Ion species analysis results show that the deuteron fraction is as high as 99.5%. All of the parameters satisfy PKUNIFTY's requirements. In this paper, we will describe the deuteron injector design and report the commissioning results as well as the initial operation.

43 PARTICLE ACCELERATORS↗

First Beam Waist Measurements in the Final Focus Beam Line at the KEK Accelerator Test Facility

The ATF2 project is the final focus system prototype for the ILC and CLIC linear collider projects, with a purpose to reach a 37 nm vertical beam size at the interaction point using compact optics based on a novel scheme of local chromaticity correction. Construction of all components and installation were completed at the end of 2008. An initial commissioning phase followed in 2009, using larger than nominal {beta} functions at the interaction point, corresponding to reduced demagnification factors in comparison to the design, to limit effects from higher-order optical aberrations and hence simplify beam tuning procedures while key instrumentation was being tested and calibrated. In this paper, first measurements of dispersion and Twiss parameters are presented based on scanning the beam during this period with a set of tungsten wires located just behind the interaction point, using two complementary analysis methods.

43 PARTICLE ACCELERATORS↗

SU-F-T-146: Comparing Monte Carlo Simulations with Commissioning Beam Data for Mevion S250 Proton Therapy System

Purpose: To evaluate the Monte Carlo simulated beam data with the measured commissioning data for the Mevion S250 proton therapy system. Method: The Mevion S250 proton therapy system utilizes a passive double scattering technique with a unique gantry mounted superconducting accelerator and offers effective proton therapy in a compact design concept. The field shaping system (FSS) includes first scattering foil, range modulator wheel (RMW), second scattering foil and post absorber and offers two field sizes and a total of 24 treatment options from proton range of 5 cm to 32 cm. The treatment nozzle was modeled in detail using TOPAS (TOolkit for PArticle Simulation) Monte Carlo code. The timing feathers of the moving modulator wheels were also implemented to generate the Spread Out Bragg Peak (SOBP). The simulation results including pristine Bragg Peak, SOBP and dose profiles were compared with the data measured during beam commissioning. Results: The comparison between the measured data and the simulation data show excellent agreement. For pristine proton Bragg Peaks, the simulated proton range (depth of distal 90%) values agreed well with the measured range values within 1 mm accuracy. The differences of the distal falloffs (depth from distal 80% to 20%) were also found to be less than 1 mm between the simulations and measurements. For the SOBP, the widths of modulation (depth of proximal 95% to distal 90%) were also found to agree with the measurement within 1 mm. The flatness of the simulated and measured lateral profiles was found to be 0.6 % and 1.1 %, respectively. Conclusion: The agreement between simulations and measurements demonstrate that TOPAS could be used as a viable platform to proton therapy applications. The matched simulation results offer a great tool and open opportunity for variety of applications.

60 APPLIED LIFE SCIENCES↗

The CUORE and CUORE-0 experiments at LNGS

The Cryogenic Underground Observatory for Rare Events (CUORE) is the first bolometric experiment searching for neutrinoless double beta decay that has been able to reach the 1-ton scale. The detector consists of an array of 988 TeO2 crystals arranged in a cylindrical compact structure of 19 towers. The construction of the experiment and, in particular, the installation of all towers in the cryostat was completed in August 2016 and commissioning started in fall 2016. The experiment has completed the pre-operation phase and is currently in data taking. We present here the achievements of CUORE during the commissioning phase and the limit on the 130Te half-life for the neutrinoless double beta decay that has been released after the first 3 weeks of collected data. Physics results from CUORE-0 will also be updated.

Alduino, C↗

High Temperature Heat Exchanger Design and Fabrication for Systems with Large Pressure Differentials

The project’s main purpose was to design, build and test a compact heat exchanger for supercritical carbon dioxide (sCO 2 ) power cycle recuperators. The compact recuperator is required to operate at high temperature and high pressure differentials, 169 bar (~2,500 psi), between streams of sCO 2 . Additional project tasks included building a hot air-to-sCO 2 Heater heat exchanger (HX) and design, build and operate a test loop to characterize the recuperator and heater heat exchangers. A novel counter-current microtube recuperator was built to meet the high temperature high differential pressure criteria and tested. The compact HX design also incorporated a number of features that optimize material use, improved reliability and reduced cost. The air-to-sCO 2 Heater HX utilized a cross flow, counter-current, micro-tubular design. This compact HX design was incorporated into the test loop and exceeded design expectations. The test loop design to characterize the prototype Brayton power cycle HXs was assembled, commissioned and operated during the program. Both the prototype recuperator and Heater HXs were characterized. Measured results for the recuperator confirmed the predictions of the heat transfer models developed during the project. Heater HX data analysis is ongoing.

20 FOSSIL-FUELED POWER PLANTS↗

SCALE Analyses of Scenarios in the TRISO-based Heat Pipe Microreactor Fuel Cycle

This report documents the application of the SCALE code to the analysis of a TRistructural-ISOtropic (TRISO)-based heat pipe microreactor (HPMR) within the context of its nuclear fuel cycle stages. The evaluation was conducted in support of the US Nuclear Regulatory Commission’s ongoing efforts to assess modeling capabilities for advanced non–light-water reactor technologies. The generic HPMR selected as a representative microreactor concept features a compact core design that incorporates TRISO fuel compacts, passive heat removal via heat pipes, and a transportable configuration intended for deployment in remote environments.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Success in commissioning a key U.S. radioactive waste burial site through the technical support of Dufrane Nuclear Shielding Incorporated (DNSI) - 15476

With the -phase out- of the South Carolina based Barnwell Radioactive Waste Burial Site, and the stockpile and storage of radioactive waste and irradiated components throughout the U.S. Nuclear Industry for decades, the opening of the Texas Low-Level Radioactive Waste Disposal Compact Facility by Waste Control Specialists (WCS), is a game changer in solving this industry-wide issue. For the first time in decades, generators now have the opportunity to send their waste to a site specifically designed to permanently sequester the waste in a licensed facility that will protect public health and the environment, better than any built to date. As history has shown through the many decades of the U.S. Commercial and Federal Nuclear Industry, site operators and management have relied heavily on contractors and vendors with exceptional expertise and decades of experience to achieve success and meet their goals. The commissioning of WCS was no exception as DNSI was contracted to design, develop, build and deploy a major component required for the opening and successful operation of the WCS site. This component, being the Modular Concrete Canister (MCC), is the -work horse- of the site. With its enormous size, weight and strength, it provides many functions that meet and comply with the site performance assessment (PA) under 10 CFR Part 61, the site WAC, and Texas Low-Level Radioactive Waste Disposal Authority. Offsite contracting the production and delivery of this critical component was a major step toward success in meeting schedule and cost for the much needed opening of the Texas Compact and Federal site. In selecting a shielding vendor, WCS partnered with a U.S. Nuclear Service company with over 30 years of experience which spans the entire U.S. Commercial, Federal, and Nuclear Industry. The task given DNSI was not a simple one, it involved every aspect from start to finish of the design, production and delivery of rectangular, cylindrical and -irradiated hardware- (IH) MCCs, that could accept waste up to 100 Sv /Hr contact dose rates. The enormity of this project was quite clear and required extensive quality control, construction of batch plants, purchase of huge quantities of raw materials, setting up a production site in a neighboring city, relocation of personnel from company headquarters, and safely transporting 8,000 Tons of MCC components 75 miles one-way on West Texas highways daily. Most important of all, this was accomplished safely with no incidents, no component failures or rejects, and on schedule. The start of receipt, of -in-compact waste- and -out-of-compact waste- was conducted virtually in a 3 month period time span. To help guarantee success and quality of product, all forms had surfaces machined, heavy duty elastomer coatings were applied to concrete surfaces, only galvanized anchors were used, and the batch plant was run to strict ASME standards thus testing every 50 cubic yards of concrete poured. With significant teamwork and success from Vendors such as DNSI, WCS and the Texas Compact has evolved as one of the leading radioactive waste sites in the U.S. and the world, providing safe, secure and compliant permanent waste disposal services by using technical expertise and innovation of the highest standards. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗