At least 55 records · Page 3

Experimental Investigation of Flow Condensation in Microgravity

Future manned missions to Mars are expected to greatly increase the space vehicle's size, weight, and heat dissipation requirements. An effective means to reducing both size and weight is to replace single-phase thermal management systems with two-phase counterparts that capitalize upon both latent and sensible heat of the coolant rather than sensible heat alone. This shift is expected to yield orders of magnitude enhancements in flow boiling and condensation heat transfer coefficients. A major challenge to this shift is a lack of reliable tools for accurate prediction of two-phase pressure drop and heat transfer coefficient in reduced gravity. Developing such tools will require a sophisticated experimental facility to enable investigators to perform both flow boiling and condensation experiments in microgravity in pursuit of reliable databases. This study will discuss the development of the Flow Boiling and Condensation Experiment (FBCE) for the International Space Station (ISS), which was initiated in 2012 in collaboration between Purdue University and NASA Glenn Research Center. This facility was recently tested in parabolic flight to acquire condensation data for FC-72 in microgravity, aided by high-speed video analysis of interfacial structure of the condensation film. The condensation is achieved by rejecting heat to a counter flow of water, and experiments were performed at different mass velocities of FC-72 and water and different FC-72 inlet qualities. It is shown that the film flow varies from smooth-laminar to wavy-laminar and ultimately turbulent with increasing FC-72 mass velocity. The heat transfer coefficient is highest near the inlet of the condensation tube, where the film is thinnest, and decreases monotonically along the tube, except for high FC-72 mass velocities, where the heat transfer coefficient is enhanced downstream. This enhancement is attributed to both turbulence and increased interfacial waviness. One-ge correlations are shown to predict the average condensation heat transfer coefficient with varying degrees of success, and a recent correlation is identified for its superior predictive capability, evidenced by a mean absolute error of 21.7%.

microgravity↗

Superconductor to exciton condensate transition in a model copper-oxide material

Abstract Superconductivity and exciton condensation are fundamental phenomena in condensed matter physics, associated with the condensation of electron–electron and electron–hole pairs, respectively, into coherent quantum states. In this study, we present evidence of a superconductor to exciton condensate transition within the context of the three-band Hubbard model of copper-oxide-like materials. As the electron–electron repulsion increases, the superconducting phase is superseded by exciton condensation. In support of theoretical predictions—not yet realized experimentally—we observe the coexistence of the two condensates in the vicinity of the transition where the quantum states become a superposition of electron–electron and electron–hole condensates. Coexistence is rigorously computed from large eigenvalues and their eigenvectors in both the two-electron reduced density matrix (2-RDM) and the particle-hole RDM, which we obtain from a direct variational ground-state energy minimization with respect to the 2-RDM by semidefinite programming. We further discern that adjacent d orbitals and intervening p orbitals facilitate electron–electron pairing between copper orbitals, thereby supporting the superexchange mechanism for superconductivity. These observations suggest the feasibility of witnessing a superconductor to exciton condensate transition in copper-oxide analogs, bearing significant implications for identifying materials conducive to efficient transport processes.

Schouten, Anna O. (ORCID:0000000264255219)↗

Internally drained condenser for spacecraft thermal management

This paper presents the results obtained to date in a program to develop a high heat flux condenser for use in two-phase spacecraft thermal management loops. The objective is to obtain a several fold increase in condensation heat transfer coefficient over those which can be achieved with shear-controlled or capillary-wick condensers. The internally drained condenser relies on shaped fins to develop a capillary pressure gradient over the surface of the fins and drive the condensate toward narrow drainage grooves separating the fins. The condensate then flows through a drainage network embedded in the condenser walls. Heat transfer coefficients of up to 8 W/sq cm C were measured in steam, providing a heat transfer enhancement ratio greater than a factor of 8. In the paper the proof-of-concept experiments are described and simplified models to predict the performance of the internally drained condenser are presented.

Valenzuela, Javier A.↗

Chemical Analysis and Water Recovery Testing of Shuttle-Mir Humidity Condensate

Humidity condensate collected and processed in-flight is an important component of a space station drinking water supply. Water recovery systems in general are designed to handle finite concentrations of specific chemical components. Previous analyses of condensate derived from spacecraft and ground sources showed considerable variation in composition. Consequently, an investigation was conducted to collect condensate on the Shuttle while the vehicle was docked to Mir, and return the condensate to Earth for testing. This scenario emulates an early ISS configuration during a Shuttle docking, because the atmospheres intermix during docking and the condensate composition should reflect that. During the STS-89 and STS-91 flights, a total volume of 50 liters of condensate was collected and returned. Inorganic and organic chemical analyses were performed on aliquots of the fluid. Tests using the actual condensate were then conducted with scaled-down elements of the Russian condensate recovery system to determine the quality of water produced. The composition and test results are described, and implications for ISS are discussed.

Mudgett, Paul D.↗

Conceptual Design of a Condensing Heat Exchanger for Space Systems Using Porous Media

Condensing heat exchangers are used in many space applications in the thermal and humidity control systems. In the International Space Station (ISS), humidity control is achieved by using a water cooled fin surface over which the moist air condenses, followed by "slurper bars" that take in both the condensate and air into a rotary separator and separates the water from air. The use of a cooled porous substrate as the condensing surface provides and attractive alternative that combines both heat removal as well as liquid/gas separation into a single unit. By selecting the pore sizes of the porous substrate a gravity independent operation may also be possible with this concept. Condensation of vapor into and on the porous surface from the flowing air and the removal of condensate from the porous substrate are the critical processes involved in the proposed concept. This paper describes some preliminary results of the proposed condensate withdrawal process and discusses the on-going design and development work of a porous media based condensing heat exchanger at the NASA Glenn Research Center in collaboration with NASA Johnson Space Center.

Hasan, Mohammad M.↗

Freeze-Tolerant Condensers

Two condensers designed for use in dissipating heat carried by working fluids feature two-phase, self-adjusting configurations such that their working lengths automatically vary to suit their input power levels and/or heat-sink temperatures. A key advantage of these condensers is that they can function even if the temperatures of their heat sinks fall below the freezing temperatures of their working fluids and the fluids freeze. The condensers can even be restarted from the frozen condition. The top part of the figure depicts the layout of the first condenser. A two-phase (liquid and vapor) condenser/vapor tube is thermally connected to a heat sink typically, a radiatively or convectively cooled metal panel. A single-phase (liquid) condensate-return tube (return artery) is also thermally connected to the heat sink. At intervals along their lengths, the condenser/vapor tube and the return artery are interconnected through porous plugs. This condenser configuration affords tolerance of freezing, variable effective thermal conductance (such that the return temperature remains nearly constant, independently of the ultimate sink temperature), and overall pressure drop smaller than it would be without the porous interconnections. An additional benefit of this configuration is that the condenser can be made to recover from the completely frozen condition either without using heaters, or else with the help of heaters much smaller than would otherwise be needed. The second condenser affords the same advantages and is based on a similar principle, but it has a different configuration that affords improved flow of working fluid, simplified construction, reduced weight, and faster recovery from a frozen condition.

Crowley, Christopher J.↗

An evolutionary system of mineralogy. Part II: Interstellar and solar nebula primary condensation mineralogy (>4.565 Ga)

The evolutionary system of mineralogy relies on varied physical and chemical attributes, including trace elements, isotopes, solid and fluid inclusions, and other information-rich characteristics, to understand processes of mineral formation and to place natural condensed phases in the deep-time context of planetary evolution. Part I of this system reviewed the earliest refractory phases that condense at T > 1000 K within the turbulent expanding and cooling atmospheres of highly evolved stars. Part II considers the subsequent formation of primary crystalline and amorphous phases by condensation in three distinct mineral-forming environments, each of which increased mineralogical diversity and distribution prior to the accretion of planetesimals >4.5 billion years ago. (1) Interstellar molecular solids: Varied crystalline and amorphous molecular solids containing primarily H, C, O, and N are observed to condense in cold, dense molecular clouds in the interstellar medium (10 < T < 20 K; P < 10−13 atm). With the possible exception of some nanoscale organic condensates preserved in carbonaceous meteorites, the existence of these phases is documented primarily by telescopic observations of absorption and emission spectra of interstellar molecules in radio, microwave, or infrared wavelengths. (2) Nebular and circumstellar ice: Evidence from infrared observations and laboratory experiments suggest that cubic H2O (“cubic ice”) condenses as thin crystalline mantles on oxide and silicate dust grains in cool, distant nebular and circumstellar regions where T ~100 K. (3) Primary condensed phases of the inner solar nebula: The earliest phase of nebular mineralogy saw the formation of primary refractory minerals that solidified through high-temperature condensation (1100 < T < 1800 K; 10−6 < P < 10−2 atm) in the solar nebula more than 4.565 billion years ago. These earliest mineral phases originating in our solar system formed prior to the accretion of planetesimals and are preserved in calcium-aluminum-rich inclusions, ultra-refractory inclusions, and amoeboid olivine aggregates.

Shaunna M. Morrison↗

Dynamic condensation model of rolling droplets for high-performance heat transfer

Condensation is a critical process during vapor-liquid phase change in relation to heat transfer. To achieve a high heat transfer coefficient, the classical model for dropwise condensation requires a low contact angle and low contact angle hysteresis, failing to align with experimental observations on a hydrophobic and slippery quasi-liquid surface (QLS). Here, we report a dynamic condensation model that incorporates high-frequency condensate removal by emphasizing the role of timescale during droplet growth and shedding. Our model agrees well with the experimental result that a surface with high contact angle and low contact angle hysteresis promotes condensation, particularly during rolling-propelled condensate removal. Particle image velocimetry reveals that rolling droplets on a hydrophobic QLS exhibit 4-fold higher shedding speeds than the sliding droplets on a hydrophilic QLS, leading to significant heat transfer enhancement. This work deepens our theoretical understanding of condensation heat transfer and provides advanced physics-informed design rationales for water and energy systems.

42 ENGINEERING↗

Multipolar condensates and multipolar Josephson effects

When single-particle dynamics are suppressed in certain strongly correlated systems, dipoles arise as elementary carriers of quantum kinetics. These dipoles can further condense, providing physicists with a rich realm to study fracton phases of matter. Whereas recent theoretical discoveries have shown that an unconventional lattice model may host a dipole condensate as the ground state, we show that dipole condensates prevail in bosonic systems due to a self-proximity effect. Our findings allow experimentalists to manipulate the phase of a dipole condensate and deliver dipolar Josephson effects, where supercurrents of dipoles arise in the absence of particle flows. The self-proximity effects can also be utilized to produce a generic multipolar condensate. The kinetics of the n -th order multipoles unavoidably creates a condensate of the ( n + 1)-th order multipoles, forming a hierarchy of multipolar condensates that will offer physicists a whole new class of macroscopic quantum phenomena.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Atomic-Scale Imaging of Condensed Counterions

Here, the functioning of a wide variety of charged macromolecules, from DNA to fuel cell membranes, is dependent on how the counterions surrounding them are arranged. In order to decrease Coulombic repulsion, some of the fixed charges on these molecules are neutralized by a fraction of the counterions-this phenomenon is called counterion condensation. The nature of counterion condensation can be only be inferred indirectly from traditional experiments such as X-ray scattering and modern experiments such as single molecule electrometry. The prevalent conclusion in the literature, based on both theory and experiment, is that the distribution of counterions is peaked right next to the macromolecule, i.e., condensation results in the formation of contact ion pairs. In this study, cryogenic electron microscopy (cryo-EM) was used to study the arrangement of condensed halide counterions near a positively charged polypeptoid nanofiber. The locations of both condensed and fixed charges were determined directly from atomic-scale images. Our experimentally determined counterion distributions were peaked at distances of about 5 Å away from the fixed positive charge, indicating the presence of a layer of water molecules between condensed ion pairs. We posit that this distribution is driven by the entropy of the condensed ions.

36 MATERIALS SCIENCE↗

Fabrication of Large-Area Metal-on-Carbon Catalytic Condensers for Programmable Catalysis

Catalytic condensers stabilize charge on either side of a high-k dielectric film to modulate the electronic states of a catalytic layer for the electronic control of surface reactions. Here, carbon sputtering provided for fast, large-scale fabrication of metal–carbon catalytic condensers required for industrial application. Carbon films were sputtered on HfO 2 dielectric/p-type Si with different thicknesses (1, 3, 6, and 10 nm), and the enhancement of conductance and capacitance of carbon films was observed upon increasing the carbon thickness following thermal treatment at 400 °C. After Pt deposition on the carbon films, the Pt catalytic condenser exhibited a high capacitance of ∼210 nF/cm 2 that was maintained at a frequency ∼1000 Hz, satisfying the requirement for a dynamic catalyst to implement catalytic resonance. Temperature-programmed desorption of carbon monoxide yielded CO desorption peaks that shifted in temperature with the varying potential applied to the condenser (−6 or +6 V), indicating a shift in the binding energy of carbon monoxide on the Pt condenser surface. A substantial increase in capacitance (∼2000 nF/cm 2 ) of the Pt-on-carbon devices was observed at elevated temperatures of 400 °C that can modulate ∼10% of charge per metal atom when 10 V potential was applied. A large catalytic condenser of 42 cm 2 area Pt/C/HfO 2 /Si exhibited a high capacitance of 9393 nF with a low leakage current/capacitive current ratio (<0.1), demonstrating the practicality and versatility of the facile, large-scale fabrication method for metal–carbon catalytic condensers.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Laminar film condensation on the inside of slender, rotating truncated cones.

A solution for film condensation on the inside of slender rotating truncated cones is established in the region where the half cone angle phi is close to zero and where the equation of Dhir and Lienhard (1971) is no longer valid. All the familiar assumptions used in Nusselt's theory of laminar film condensation are assumed valid, including negligible sub-cooling and momentum changes in the condensate film, no interfacial shear between the condensate and the vapor, and pure conduction within the condensate film. A Runge-Kutta numerical integration method using a digital computer was used. Results for a specific geometry are given for water condensing at 212 F on a condenser wall maintained at 70 F.

Marto, P. J.↗

Condensation of water vapor in rarefaction waves. I - Homogeneous nucleation

A detailed theoretical investigation has been made of the condensation of water vapor/carrier gas mixtures in the nonstationary rarefaction wave generated in a shock tube. It is assumed that condensation takes place by homogeneous nucleation. The equations of motion together with the nucleation rate and the droplet growth equations were solved numerically by the method of characteristics and Lax's method of implicit artificial viscosity. It is found that, for the case considered, the condensation wave formed by the collapse of the metastable nonequilibrium state is followed by a shock wave generated by the intersection of characteristics of the same family. The expansion is practically isentropic up to the onset of condensation. The condensation front accelerates in the x,t plane. The results of the computations for a chosen case of water vapor/nitrogen mixture are presented by plotting variations of pressure, nucleation rate, number density of critical clusters, and condensate mass-fraction along three particle paths. Some consideration is given to homogeneous condensation experiments conducted in a shock tube. Although a direct comparison of the present theoretical work and these experiments is not possible, several worthwhile interpretative features have resulted nevertheless.

Sislian, J. P.↗

Condensation heat transfer in a microgravity environment

In the present treatment of the condensation heat transfer process in a microgravity environment, two mechanisms for condensate removal are analyzed in light of two problems: (1) film condensation on a flat, porous plate, with condensate being removed by wall suction; and (2) the analytical prediction of the heat transfer coefficient of condensing annular flows, where the condensate film is driven by vapor shear. Both suction and vapor shear can effectively drain the condensate, ensuring continuous operation in microgravity.

Chow, L. C.↗

Condensation shocks in hypersonic nitrogen tunnels

Experimental observations and a theoretical model for the onset and disappearance of condensation are provided for hypersonic flows of pure nitrogen at M = 10, 14, and 18. A method for analyzing the thermodynamic and flow properties of a partially condensed mixture from known supply conditions and measured Pitot pressure yields the local static pressure and temperature, mass fraction of the nitrogen condensed, and the Mach number of the partially condensed flow based on frozen sound speed. The transition between partially condensed-supercooled flow is found to occur at 22-25 K isobaric supercooling with the corresponding mass fraction condensed being 12-14 percent over a range of two orders of magnitude in local static pressure. The heat released and vapor mass removed during condensation ultimately raise the local pressure and temperature and reduce the flow Mach number.

Hudson, Susan T.↗

Characterization of spacecraft humidity condensate

When construction of Space Station Freedom reaches the Permanent Manned Capability (PMC) stage, the Water Recovery and Management Subsystem will be fully operational such that (distilled) urine, spent hygiene water, and humidity condensate will be reclaimed to provide water of potable quality. The reclamation technologies currently baselined to process these waste waters include adsorption, ion exchange, catalytic oxidation, and disinfection. To ensure that the baseline technologies will be able to effectively remove those compounds presenting a health risk to the crew, the National Research Council has recommended that additional information be gathered on specific contaminants in waste waters representative of those to be encountered on the Space Station. With the application of new analytical methods and the analysis of waste water samples more representative of the Space Station environment, advances in the identification of the specific contaminants continue to be made. Efforts by the Water and Food Analytical Laboratory at JSC were successful in enlarging the database of contaminants in humidity condensate. These efforts have not only included the chemical characterization of condensate generated during ground-based studies, but most significantly the characterization of cabin and Spacelab condensate generated during Shuttle missions. The analytical results presented in this paper will be used to show how the composition of condensate varies amongst enclosed environments and thus the importance of collecting condensate from an environment close to that of the proposed Space Station. Although advances were made in the characterization of space condensate, complete characterization, particularly of the organics, requires further development of analytical methods.

Muckle, Susan↗

Investigation of Condensing Ice Heat Exchangers for MTSA Technology Development

Metabolic heat regenerated Temperature Swing Adsorption (MTSA) technology is being developed for thermal, carbon dioxide (CO2) and humidity control for a Portable Life Support Subsystem (PLSS). Metabolically-produced CO2 present in the ventilation gas of a PLSS is collected using a CO2selective adsorbent via temperature swing adsorption. The temperature swing is initiated through cooling to well below metabolic temperatures. Cooling is achieved with a sublimation heat exchanger using water or liquid carbon dioxide (LCO2) expanded below sublimation temperature when exposed to low pressure or vacuum. Subsequent super heated vapor, as well as additional coolant, is used to further cool the astronaut. The temperature swing on the adsorbent is then completed by warming the adsorbent with a separate condensing ice heat exchanger (CIHX) using metabolic heat from moist ventilation gas. The condensed humidity in the ventilation gas is recycled at the habitat. The water condensation from the ventilation gas is a significant heat transfer mechanism for the warming of the adsorbent bed because it represents as much as half of the energy potential in the moist ventilation gas. Designing a heat exchanger to efficiently transfer this energy to the adsorbent bed and allow the collection of the water is a challenge since the CIHX will operate in a temperature range from 210K to 280K. The ventilation gas moisture will first freeze and then thaw, sometimes existing in three phases simultaneously. A NASA Small Business Innovative Research (SBIR) Phase 1 contract was performed to investigate condensing and icing as applied to MTSA to enable higher fidelity modeling and assess the impact of geometry variables on CIHX performance for future CIHX design optimization. Specifically, a design tool was created using analytical relations to explore the complex, interdependent design space of a condensing ice heat exchanger. Numerous variables were identified as having nontrivial contributions to performance such as hydraulic diameter, heat exchanger effectiveness, ventilation gas mass flow rate and surface roughness. Using this tool, four test articles were designed and manufactured to map to a full MTSA subassembly (the adsorbent bed, the sublimation heat exchanger for cooling and the condensing ice heat exchanger for warming). The design mapping considered impacts due to CIHX geometry as well as subassembly impacts such as thermal mass and thermal resistance through the adsorbent bed. The test articles were tested at simulated PLSS ventilation loop temperature, moisture content and subambient pressure. Ice accumulation and melting were observed. Data and test observations were analyzed to identify drivers of the condensing ice heat exchanger performance. This paper will discuss the analytical models, the test article designs, and testing procedures. Testing issues will be discussed to better describe data and share lessons learned. Data analysis and subsequent conclusions will be presented.

Padilla, Sebastian↗

Deepak Condenser Model (DeCoM)

Development of the DeCoM comes from the requirement of analyzing the performance of a condenser. A component of a loop heat pipe (LHP), the condenser, is interfaced with the radiator in order to reject heat. DeCoM simulates the condenser, with certain input parameters. Systems Improved Numerical Differencing Analyzer (SINDA), a thermal analysis software, calculates the adjoining component temperatures, based on the DeCoM parameters and interface temperatures to the radiator. Application of DeCoM is (at the time of this reporting) restricted to small-scale analysis, without the need for in-depth LHP component integrations. To efficiently develop a model to simulate the LHP condenser, DeCoM was developed to meet this purpose with least complexity. DeCoM is a single-condenser, single-pass simulator for analyzing its behavior. The analysis is done based on the interactions between condenser fluid, the wall, and the interface between the wall and the radiator. DeCoM is based on conservation of energy, two-phase equations, and flow equations. For two-phase, the Lockhart- Martinelli correlation has been used in order to calculate the convection value between fluid and wall. Software such as SINDA (for thermal analysis analysis) and Thermal Desktop (for modeling) are required. DeCoM also includes the ability to implement a condenser into a thermal model with the capability of understanding the code process and being edited to user-specific needs. DeCoM requires no license, and is an open-source code. Advantages to DeCoM include time dependency, reliability, and the ability for the user to view the code process and edit to their needs.

Patel, Deepak↗