Search NASA⌕ Search

SEARCH · Search NASA

Results for “CONES”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 55 records · Page 3

Sintering and collapse of synthetic coal ash and slag cones as observed through constant heating rate optical dilatometry

Ash agglomeration and slagging are responsible for costly maintenance problems in coal-fired boilers. Boiler design and operation rely on critical ash fusion temperatures defined by geometric criteria that explicitly ignore shrinkage or warping. Reproducibility of ash fusion test (AFT) results is known to be a major problem, given the subjective nature of some criteria used in critical temperature reporting. Decades of faulty predictions based on AFT data underscore the need for an objective measure of the likelihood for agglomeration and slagging as a function of coal ash composition and temperature. Heating microscopes and ash fusibility determinators are AFT instruments that are widely available and readily adapted for optical dilatometry of ash cones through digital image analysis. Optical dilatometry enables the continuous measurement of cone height and face area, and the calculation of changes in cone volume and density as a function of temperature during constant heating. A strong correlation was found between the sintering onset temperatures of two synthetic ash compositions measured through optical dilatometry and their corresponding solidus temperatures predicted through thermophysical modeling. The sintering onset temperatures of synthetic slag cones appears consistent with glass transition temperatures estimated using the Kauzmann-Beaman rule. Cone collapse is highly correlated with softening, hemispherical, and fluid temperatures for ash cones. Rapid changes in solid, liquid, and gas volume fractions near the collapse temperature suggest that a transition from capillary to slurry state may play an important role in triggering collapse. Slag cone collapse is better explained by a decrease in viscosity as a function of temperature in the glass working range. Furthermore, the sintering onset temperature and cone collapse temperature are readily understood through thermophysical modeling based on ash composition and provide two additional critical temperatures in the modeling of coal ash agglomeration and slagging.

01 COAL, LIGNITE, AND PEAT↗

Micro focusing of fast electrons with opened cone targets

Using opened reentrant cone silicon targets, we have demonstrated the effect of micro focusing of fast electrons generated in intense laser-plasma interactions. When an intense femtosecond laser pulse is focused tightly onto one of the side walls of the cone, fast electron beam emitted along the side wall is observed. When a line focus spot, which is long enough to irradiate both of the side walls of the cone simultaneously, is used, two electron beams emitted along each side wall, respectively, are observed. The two beams should cross each other near the open tip of the cone, resulting in micro focusing. We use a two-dimensional Particle-In-Cell code to simulate the electron emission both in opened and closed cone targets. The simulation results of the opened cone targets are in agreement with the experimental observation while the results of the closed cone targets do not show the micro focusing effect.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Direct evidence of interaction-induced Dirac cones in a monolayer silicene/Ag(111) system

Silicene, analogous to graphene, is a one-atom-thick 2D crystal of silicon, which is expected to share many of the remarkable properties of graphene. The buckled honeycomb structure of silicene, along with enhanced spin-orbit coupling, endows silicene with considerable advantages over graphene in that the spin-split states in silicene are tunable with external fields. Although the low-energy Dirac cone states lie at the heart of all novel quantum phenomena in a pristine sheet of silicene, a hotly debated question is whether these key states can survive when silicene is grown or supported on a substrate. Here we report our direct observation of Dirac cones in monolayer silicene grown on a Ag(111) substrate. By performing angle-resolved photoemission measurements on silicene(3 × 3)/Ag(111), we reveal the presence of six pairs of Dirac cones located on the edges of the first Brillouin zone of Ag(111), which is in sharp contrast to the expected six Dirac cones centered at the K points of the primary silicene(1 × 1) Brillouin zone. Our analysis shows clearly that the unusual Dirac cone structure we have observed is not tied to pristine silicene alone but originates from the combined effects of silicene(3 × 3) and the Ag(111) substrate. Our study thus identifies the case of a unique type of Dirac cone generated through the interaction of two different constituents. The observation of Dirac cones in silicene/Ag(111) opens a unique materials platform for investigating unusual quantum phenomena and for applications based on 2D silicon systems.

36 MATERIALS SCIENCE↗

SU-E-T-370: Measurement of Conical Cone Output Factors for the Varian Edge Linear Accelerator

Purpose: To quantify the impact of detector type, SSD/depth, and intermediate reference on conical cone output factor (OF) measurements for the Varian Edge linac. Methods: OF's for 4, 5, 7.5, 10, 12.5, 15, and 17.5 mm diameter cones relative to 10cmx10cm field were measured for the 6X FFF and 10X FFF energies, with jaws set to 5cmx5cm. Measurements were performed with an Edge diode (0.8mmx0.8mmx0.03mm WxLxT), stereotatic diode SFD, photon diode, CC01 and pinpoint chambers (2mm diameter for both). 95cm SSD/5cm depth were used in a water tank. For the measurement with diodes, OF's were cross-referred to CC13 ion chamber measurements with 3cmx3cm field, as recommended, to help mitigate the energy variation in diode response with field size. Results were compared to the representative data from Varian measured with Edge detector. With SFD, OF's at 98.5cm SSD/1.5cm depth and 90cm SSD/10cm depth were also measured. Results: OF's measured with the Edge detector matched within 1.3% (max diff) with the representative data from Varian. For the SFD, OF's matched within 1.3% for the 4, 5 and 17.5 mm cones and within 3.7% for the other cones. OF's with photon diode were within 1.3% except for the 4 and 5 mm cones where they were 8.1% and 3.7%, respectively. OF's for the CC01 and pinpoint chamber deviated up to 36% and 44%, respectively for the 4 mm cone. OF's after intermediate reference with 3cmx3cm field changed by 3.7% for SFD, 0.8% for photon diode, and 0.6% for Edge detector. OF's at 98.5cm SSD/1.5cm depth were 10.8% higher than that at 95cm SSD/5cm depth, and OF's at 90cm SSD/1.5cm depth were 7.5% lower. Conclusion: OF's measured with the Edge detector appear to be reliable. CC01 and pinpoint chambers do not appear suitable for measuring the small cone OF's. SSD/depth affects OF measurements significantly.

07 ISOTOPE AND RADIATION SOURCES↗

HopBox: An image analysis pipeline to characterize hop cone morphology

Abstract Hop cone morphology can influence picking and drying ability, and color can impact consumer preference and may be indicative of quality. However, these characteristics are not generally evaluated in hop breeding programs due to the tedious nature of trait quantification and the extensive variation among cones within a genotype. We developed the HopBox, which is a simply constructed light box with a camera mount, and a publicly available image processing pipeline that identifies hop cones within color‐corrected images, reads a QR code within the image, and outputs data on hop cone length, width, area, perimeter, openness, weight, color, and density. The trained model was applied to images of 500 cones each from 15 replicated advanced hop genotypes from the USDA‐ARS breeding program in Prosser, Washington. Analysis of variance revealed significant ( p < 0.001) differences between genotypes for all traits measured, enabling breeders to discriminate between genotypes for selection purposes. Broad sense heritability for all traits ranged from 0.23 to 0.59. A random sampling of hop cones from the complete dataset revealed that imaging only 5–10 cones adequately captured genotypic variation and provided acceptable rank correlations ( r s > 0.75); however, increasing the sample size to 30 provided optimal precision. Instructions for constructing a HopBox and the code for the analysis pipeline are publicly available online and have wide applicability for hop breeding and research.

Altendorf, Kayla R.↗

Exploring the holographic entropy cone via reinforcement learning

We develop a reinforcement learning algorithm to study the holographic entropy cone. Given a target entropy vector, our algorithm searches for a graph realization whose min-cut entropies match the target vector. If the target vector does not admit such a graph realization, it must lie outside the cone, in which case the algorithm finds a graph whose corresponding entropy vector most nearly approximates the target and allows us to probe the location of the facets. For the N = 3 cone, we confirm that our algorithm successfully rediscovers monogamy of mutual information beginning with a target vector outside the holographic entropy cone. We then apply the algorithm to the N = 6 cone, analyzing the 6 mystery extreme rays of the subadditivity cone from [1] that satisfy all known holographic entropy inequalities yet lacked graph realizations. We found realizations for 3 of them, proving they are genuine extreme rays of the holographic entropy cone, while providing evidence that the remaining 3 are not realizable, implying unknown holographic inequalities exist for N = 6.

AdS-CFT correspondence↗

Regularized iterative weighted filtered backprojection for helical cone-beam CT

Contemporary reconstruction methods employed for clinical helical cone-beam computed tomography (CT) are analytical (noniterative) but mathematically nonexact, i.e., the reconstructed image contains so called cone-beam artifacts, especially for higher cone angles. Besides cone artifacts, these methods also suffer from windmill artifacts: alternating dark and bright regions creating spiral-like patterns occurring in the vicinity of high z-direction derivatives. In this article, the authors examine the possibility to suppress cone and windmill artifacts by means of iterative application of nonexact three-dimensional filtered backprojection, where the analytical part of the reconstruction brings about accelerated convergence. Specifically, they base their investigations on the weighted filtered backprojection method [Stierstorfer et al., Phys. Med. Biol. 49, 2209-2218 (2004)]. Enhancement of high frequencies and amplification of noise is a common but unwanted side effect in many acceleration attempts. They have employed linear regularization to avoid these effects and to improve the convergence properties of the iterative scheme. Artifacts and noise, as well as spatial resolution in terms of modulation transfer functions and slice sensitivity profiles have been measured. The results show that for cone angles up to {+-}2.78 deg., cone artifacts are suppressed and windmill artifacts are alleviated within three iterations. Furthermore, regularization parameters controlling spatial resolution can be tuned so that image quality in terms of spatial resolution and noise is preserved. Simulations with higher number of iterations and long objects (exceeding the measured region) verify that the size of the reconstructible region is not reduced, and that the regularization greatly improves the convergence properties of the iterative scheme. Taking these results into account, and the possibilities to extend the proposed method with more accurate modeling of the acquisition process, the authors believe that iterative improvement with non-exact methods is a promising technique for medical CT applications.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

A BPF-FBP tandem algorithm for image reconstruction in reverse helical cone-beam CT

Purpose: Reverse helical cone-beam computed tomography (CBCT) is a scanning configuration for potential applications in image-guided radiation therapy in which an accurate anatomic image of the patient is needed for image-guidance procedures. The authors previously developed an algorithm for image reconstruction from nontruncated data of an object that is completely within the reverse helix. The purpose of this work is to develop an image reconstruction approach for reverse helical CBCT of a long object that extends out of the reverse helix and therefore constitutes data truncation. Methods: The proposed approach comprises of two reconstruction steps. In the first step, a chord-based backprojection-filtration (BPF) algorithm reconstructs a volumetric image of an object from the original cone-beam data. Because there exists a chordless region in the middle of the reverse helix, the image obtained in the first step contains an unreconstructed central-gap region. In the second step, the gap region is reconstructed by use of a Pack-Noo-formula-based filteredbackprojection (FBP) algorithm from the modified cone-beam data obtained by subtracting from the original cone-beam data the reprojection of the image reconstructed in the first step. Results: The authors have performed numerical studies to validate the proposed approach in image reconstruction from reverse helical cone-beam data. The results confirm that the proposed approach can reconstruct accurate images of a long object without suffering from data-truncation artifacts or cone-angle artifacts. Conclusions: They developed and validated a BPF-FBP tandem algorithm to reconstruct images of a long object from reverse helical cone-beam data. The chord-based BPF algorithm was utilized for converting the long-object problem into a short-object problem. The proposed approach is applicable to other scanning configurations such as reduced circular sinusoidal trajectories.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

A virtual source model for Kilo-voltage cone beam CT: Source characteristics and model validation

Purpose: The purpose of this investigation was to study the source characteristics of a clinical kilo-voltage cone beam CT unit and to develop and validate a virtual source model that could be used for treatment planning purposes. Methods: We used a previously commissioned full Monte Carlo model and new bespoke software to study the source characteristics of a clinical kilo-voltage cone beam CT (CBCT) unit. We identified the main particle sources, their spatial, energy and angular distribution for all the image acquisition presets currently used in our clinical practice. This includes a combination of two energies (100 and 120 kVp), two filters (neutral and bowtie), and eight different x-ray beam apertures. We subsequently built a virtual source model which we validated against full Monte Carlo calculations. Results: We found that the radiation output of the clinical kilo-voltage cone beam CT unit investigated in this study could be reproduced with a virtual model comprising of two sources (target and filtration cone) or three sources (target, filtration cone and bowtie filter) when additional filtration was used. With this model, we accounted for more than 97% of the photons exiting the unit. Each source in our model was characterised by a origin distribution in both X and Y directions, a fluence map, a single energy spectrum for unfiltered beams and a two dimensional energy spectrum for bowtie filtered beams. The percentage dose difference between full Monte Carlo and virtual source model based dose distributions was well within the statistical uncertainty associated with the calculations ( {+-} 2%, one standard deviation) in all cases studied. Conclusions: The virtual source that we developed is accurate in calculating the dose delivered from a commercial kilo-voltage cone beam CT unit operating with routine clinical image acquisition settings. Our data have also shown that target, filtration cone, and bowtie filter sources needed to be all included in the model in order to accurately replicate the dose distribution from the clinical radiation beam.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

SU-E-T-122: Dosimetric Comparison Between Cone, HDMLC and MicroMLC for the Treatment of Trigeminal Neuralgia

Purpose: The purpose of this work was to evaluate the dosimetric characteristics of three collimation systems, 5mm circular cone (Brainlab) and square fields of 5mm with HDMLC (Varian) and microMLC Moduleaf, Siemens) for trigeminal neuralgia treatment. Methods: A TPS Iplan v4.5 BrainLAB was used to do treatment plans for each collimations system in a square solid water phantom with isocenter at 5cm depth. Single field and treatment plan including 11 arcs with fix field and 100° gantry range was made for each collimation systems. EBT3 films were positioned at isocenter in a coronal plane to measured dose distribution for all geometries. Films were digitized with a Vidar DosimetryPro Red scanner with a resolution of 89dpi and RIT113v6.1 software was used for analysis. Penumbra region (80%–20%), FWHM and dose percentage at 5mm and 10mm from CAX were determined. All profiles were normalized at CAX. Results: For single beam the penumbra (FWHM) was 1.5mm (5.3mm) for the cone, 1.9mm (5.5mm) for HDMLC and 1.8mm (5.4mm) for the microMLC. Dose percentage at 5mm was 6.9% for cone, 12.5% for HDMLC and 8.7% for the microMLC. For treatment plan the penumbra (FWHM) was 2.58mm (5.47mm) for the cone, 2.8mm (5.84mm) for HDMLC and 2.58mm (6.09mm) for the microMLC. Dose perecentage at 5mm was 13.1% for cone, 16.1% for HDMLC, 15.2% for the microMLC. Conclusion: The cone has a dose falloff larger than the microMLC and HDMLC, by its reduced penumbra, this translates into better protection of surrounding healthy tissue, however, the microMLC and HDMLC have similar accuracy to cone.

60 APPLIED LIFE SCIENCES↗

Analytic image reconstruction from partial data for a single-scan cone-beam CT with scatter correction

Purpose: A beam-blocker composed of multiple strips is a useful gadget for scatter correction and/or for dose reduction in cone-beam CT (CBCT). However, the use of such a beam-blocker would yield cone-beam data that can be challenging for accurate image reconstruction from a single scan in the filtered-backprojection framework. The focus of the work was to develop an analytic image reconstruction method for CBCT that can be directly applied to partially blocked cone-beam data in conjunction with the scatter correction. Methods: The authors developed a rebinned backprojection-filteration (BPF) algorithm for reconstructing images from the partially blocked cone-beam data in a circular scan. The authors also proposed a beam-blocking geometry considering data redundancy such that an efficient scatter estimate can be acquired and sufficient data for BPF image reconstruction can be secured at the same time from a single scan without using any blocker motion. Additionally, scatter correction method and noise reduction scheme have been developed. The authors have performed both simulation and experimental studies to validate the rebinned BPF algorithm for image reconstruction from partially blocked cone-beam data. Quantitative evaluations of the reconstructed image quality were performed in the experimental studies. Results: The simulation study revealed that the developed reconstruction algorithm successfully reconstructs the images from the partial cone-beam data. In the experimental study, the proposed method effectively corrected for the scatter in each projection and reconstructed scatter-corrected images from a single scan. Reduction of cupping artifacts and an enhancement of the image contrast have been demonstrated. The image contrast has increased by a factor of about 2, and the image accuracy in terms of root-mean-square-error with respect to the fan-beam CT image has increased by more than 30%. Conclusions: The authors have successfully demonstrated that the proposed scanning method and image reconstruction algorithm can effectively estimate the scatter in cone-beam projections and produce tomographic images of nearly scatter-free quality. The authors believe that the proposed method would provide a fast and efficient CBCT scanning option to various applications particularly including head-and-neck scan.

60 APPLIED LIFE SCIENCES↗

Heavy-to-light correlators beyond the light cone

We present the first systematic analysis of the off-light-cone effects in correlators relevant for the extraction of the heavy-to-light form factors within the method of light-cone sum rules. In a model with scalar constituents, the correlator is calculated in two different ways: (i) by performing the expansion of the Bethe-Salpeter amplitude of the light meson near the light cone x{sup 2} = 0 and (ii) by adopting the known solution for the Bethe-Salpeter amplitude which allows one to calculate the correlator without invoking any expansion. We demonstrate that the contributions to the correlator from the off-light-cone terms x{sup 2} {ne} 0 are not suppressed by any large parameter compared to the contribution of the light-cone term x{sup 2} 0. For decays of heavy particles of mass in the range 1.5-5 GeV, the light-cone correlator is shown to systematically overestimate the full correlator, numerically the difference being 10-20%.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Performance and emissions characteristics of a lighting cone for charcoal stoves

We report a lighting cone is a simple metal cone placed on the charcoal bed during ignition to increase draft. Many traditional charcoal-burning stoves are difficult to light due to poor draft through the fuel bed, so lighting cones are used as an inexpensive accessory to help with charcoal ignition. The goal of this work was to determine the validity of using a lighting cone to decrease the ignition time of traditional Haitian charcoal stoves, and evaluate its impact on stove emissions and fuel consumption during the typically inefficient and slow ignition phase. We found that the lighting cone successfully reduced ignition time by over 50%. Due to a more efficient, shorter ignition stage, charcoal consumption during ignition was reduced by over 40% and carbon monoxide was reduced by over 50%. This suggests that lighting cones are a viable and beneficial accessory for aiding ignition in shallow-bed charcoal stoves.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Modification of the Loss Cone for Energetic Particles in the Earth's Inner Magnetosphere

The behavior of energetic particles in the Earth's dipole and stretched magnetic-field models is explored with a focus on the shift of the atmospheric loss cone away from the magnetic-field direction and on non-adiabatic behavior occurring when the particle gyroradius becomes comparable with the gradient scale length of the local magnetic field. It is shown that the equatorial loss cone is aberrated away from the magnetic-field direction (pitch angle of 0°) by the perpendicular drift of a charged particle (which is referred to as the “Mozer transform” described in Mozer (1966, https://doi.org/10.1029/JZ071i011p02701). It is found that the Mozer coordinate transformation in pitch-angle/gyrophase-angle space better organizes the behavior of bounce times, mirror altitudes, drift speeds, and first adiabatic invariant. It also describes the loss-cone shift accurately for a certain range of values of the adiabaticity parameter ϵ, defined by the ratio of the particle gyroradius to the local radius of curvature of the magnetic field. For particles with larger ϵ, the Mozer transform (evaluated with the standard gradient-curvature drift) breaks down and the “central trajectory” theory can be used to calculate the angular shift of the loss cone, which now includes an Earthward shift. When ϵ becomes relatively large, stochastic field line curvature (FLC) scattering occurs: we show the intimate connection between the strength of FLC scattering and the loss-cone shift. Finally, by comparing ion orbits in the dipole and Tsyganenko (Ts89 and Ts04) magnetic fields, we conclude that the loss cone of ring-current ions is significantly modified during geomagnetically active times.

79 ASTRONOMY AND ASTROPHYSICS↗

Fast electron generation in cones with ultraintense laser pulses

Experimental results from copper cones irradiated with ultraintense laser light are presented. Spatial images and total yields of Cu K{sub {alpha}} fluorescence were measured as a function of the laser focusing properties. The fluorescence emission extends into the cone approximately 300 {mu}m from the cone tip and cannot be explained by ray tracing including cone wall absorption. In addition, the total fluorescence yield from cones is an order of magnitude higher than for equivalent mass foil targets. Indications are that the physics of the laser-cone interaction is dominated by preplasma created from the long duration, low-energy prepulse from the laser.

74 ATOMIC AND MOLECULAR PHYSICS↗

Increased efficiency of short-pulse laser-generated proton beams from novel flat-top cone targets

Ion-driven fast ignition (IFI) may have significant advantages over electron-driven FI due to the potentially large reduction in the amount of energy required for the ignition beam and the laser driver. Recent experiments at the Los Alamos National Laboratory's Trident facility employing novel Au flat-top cone targets have produced a fourfold increase in laser-energy to ion-energy efficiency, a 13-fold increase in the number of ions above 10 MeV, and a few times increase in the maximum ion energy compared to Au flat-foil targets. Compared to recently published scaling laws, these gains are even greater. If the efficiency scales with intensity in accordance to flat-foil scaling, then, with little modification, these targets can be used to generate the pulse of ions needed to ignite thermonuclear fusion in the fast ignitor scheme. A proton energy of at least 30 MeV was measured from the flat-top cone targets, and particle-in-cell (PIC) simulations show that the maximum cutoff energy may be as high as 40-45 MeV at modest intensity of 1x10{sup 19} W/cm{sup 2} with 20 J in 600 fs. Simulations indicate that the observed energy and efficiency increase can be attributed to the cone target's ability to guide laser light into the neck to produce hot electrons and transport these electrons to the flat-top of the cone where they can be heated to much higher temperatures, creating a hotter, denser sheath. The PIC simulations also elucidate the critical parameters for obtaining superior proton acceleration such as the dependence on laser contrast/plasma prefill, as well as longitudinal and transverse laser pointing, and cone geometry. These novel cones have the potential to revolutionize inertial confinement fusion target design and fabrication via their ability to be mass produced. In addition, they could have an impact on the general physics community studying basic electron and radiation transport phenomena or as better sources of particle beams to study equations of state and warm dense matter, or for hadron therapy, as new radioisotope generators, or for compact proton radiography sources.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Enhanced dense attosecond electron bunch generation by irradiating an intense laser on a cone target

By using two-dimensional particle-in-cell simulations, we demonstrate enhanced spatially periodic attosecond electron bunches generation with an average density of about 10n{sub c} and cut-off energy up to 380 MeV. These bunches are acquired from the interaction of an ultra-short ultra-intense laser pulse with a cone target. The laser oscillating field pulls out the cone surface electrons periodically and accelerates them forward via laser pondermotive force. The inner cone wall can effectively guide these bunches and lead to their stable propagation in the cone, resulting in overdense energetic attosecond electron generation. We also consider the influence of laser and cone target parameters on the bunch properties. It indicates that the attosecond electron bunch acceleration and propagation could be significantly enhanced without evident divergency by attaching a plasma capillary to the original cone tip.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Heavy-to-light correlators beyond the light cone

We present the first systematic analysis of the off-light-cone effects in correlators relevant for the extraction of the heavy-to-light form factors within the method of light-cone sum rules. In a model with scalar constituents, the correlator is calculated in two different ways: (i) by performing the expansion of the Bethe-Salpeter amplitude of the light meson near the light cone x{sup 2} = 0 and (ii) by adopting the known solution for the Bethe-Salpeter amplitude which allows one to calculate the correlator without invoking any expansion. We demonstrate that the contributions to the correlator from the off-light-cone terms x{sup 2} {ne} 0 are not suppressed by any large parameter compared to the contribution of the light-cone term x{sup 2} = 0. For decays of heavy particles of mass in the range 1.5-5 GeV, the light-cone correlator is shown to systematically overestimate the full correlator, numerically the difference being 10-20%.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗