Search NASA⌕ Search

SEARCH · Search NASA

Results for “CONTINUOUS NOISE”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 55 records · Page 3

Detailed space–time variations of the seismic response of the shallow crust to small earthquakes from analysis of dense array data

SUMMARY We compute high-resolution space–time variations of subsurface seismic properties from autocorrelation functions (ACF’s) of noise and local earthquakes, recorded by the Sage Brush Flat dense array deployed around the Clark branch of the San Jacinto fault. The resolved temporal changes are referred to as apparent velocity changes because they reflect both nonlinear response and variations of material properties such as cracking and damage. Apparent velocity changes are estimated at four frequency bands (10–15, 10–20, 15–30 and 20–40 Hz) for two local earthquake data sets. In one analysis, ACF’s from P- and S-wave windows of 31 small events with magnitudes below 3.1 are used to compute the apparent velocity variations with respect to the mean ACF of each phase, and we also use the mean ACF of noise data as reference to estimate the changes. In a further analysis, the temporal evolution of properties is computed using moving time windows in continuous waveform over one-hour long data with noise and earthquake signals. The apparent velocity changes and recovery times are frequency dependent and present a strong spatial variability across the array. The resolved changes are larger and recovery time shorter with data associated with higher frequencies. At frequencies larger than 15 Hz, and using the mean ACF of noise data as a reference, the apparent average velocity changes across the array during the passage of the P and S waves from the small local events are 2.5 per cent and 6 per cent, respectively. The apparent velocity changes decrease by one order of magnitude when the earthquake data are used as a reference. The relatively large changes in response to very low ground motion have important implications on nonlinear processes involving degradation and healing of the subsurface material during common earthquake shaking.

Geochemistry & Geophysics↗

Noise Level Hazards due to Agricultural Equipment in a Laboratory

Noise exposure is a common health hazard in the agricultural field due to the continuous use of large pieces of equipment. In lab settings it is not as common to noise exposure due to industrial scale equipment. However, the energy system laboratories at INL are exploring new and inventive ways to create energy from biomaterials. This process requires the use of large pieces of agricultural equipment such as hammer mills, shakers, conveyor belts, etc. As the researchers continuously refine this process, they not only test the limits of renewable resources for energy but also test the noise exposure threshold limits. The purpose of this project was to determine the noise level hazards which are present due to the use of large agricultural equipment in a laboratory setting.

99 GENERAL AND MISCELLANEOUS↗

Standoff Detection of Chemical Plumes Using Swept-ECQCL Remote Detection Technology: Results from EMRTC Complex Terrain Dual Tracer Experiment

As part of the Complex Terrain Dual Tracer Experiments performed in support of the LYNM program, a swept-wavelength external cavity quantum cascade laser (swept-ECQCL) remote detection system was deployed to measure chemical plume propagation with high temporal resolution. The swept-ECQCL remote detection technology was initially developed at PNNL, and is now under further development at Opticslah, LLC under SBIR funding from DOE (DOE SBIR Phase I Project DE-SC0019855, Remote Detection Technologies, Program Manager Chris Ramos). The swept-ECQCL technology provides a single-frequency infrared laser source which is rapidly scanned over a large wavelength range to measure the infrared absorption of gases, liquids, or solids. Analysis of the measured infrared absorption spectrum is used to detect, identify, and quantify the chemical species which are present. While most previous laser-based techniques used small wavelength tuning ranges to measure only a few isolated spectral lines of a few species, the swept-ECQCL provides the large tuning range needed to measure multiple species simultaneously, and to detect broad absorption features from large molecules or condensed phase materials. In addition, the swept-ECQCL systems have high enough spectral resolution and sensitivity to measure narrow lines of small molecules and determine isotope ratios. The remote detection system for gas plumes is based on the swept-ECQCL technology, and consists of a swept-ECQCL source, infrared detector, control electronics, and beam transmitting and alignment optics. The remote detection system directs the infrared output of the swept-ECQCL to a target retro reflector typically located at ~10-10,000 m distance. The swept-ECQCL wavelength is varied continuously over a large wavelength range (>1000 nm) at rates up to 1000 Hz. The swept ECQCL light reflected from the remote target is collected and focused onto an infrared photodetector. By measuring the detector signal continuously as the swept-ECQCL wavelength is varied, a time-series of absorption spectra are measured for the gases along the beam line of-sight. Based on analysis and fitting of the measured absorption spectra, the time-dependent chemical concentrations of species are determined. Multiple species and mixtures can be detected simultaneously, for all species with absorption features above the sensor noise floor. The sensor output is thus a continuous, high-speed record of identified chemicals along with their concentrations and isotope ratios of interest. The high-speed operation enables low-noise operation in conditions of atmospheric turbulence and allows tracking of fluctuating concentrations in transient chemical plumes as needed for reliable remote detection applications. All components operate with minimal cooling requirements and no cryogens are needed. In addition, the output infrared light is invisible with an intensity below the maximum permissible exposure (MPE) threshold of 100 mW/cm2 for these infrared wavelengths and thus eye safe. The measurement concept for plume detection using the swept-ECQCL remote detection system is as follows. The ECQCL beam is directed toward a remote retro-reflector, which reflects the beam back to the ECQCL system where it is focused onto an infrared photodetector. The line-of-sight from the ECQCL system to the retro-reflector defines the measurement path. The detected infrared signal is recorded continuously and detects the absorption of molecular species along the measurement path. Before a plume release, the system measures absorption from atmospheric constituents, which in this LWIR band consist primarily of lines from H 2 O and CO 2 , with additional weaker absorption from N 2 O, NH 3 , and O 3 possibly contributing. The system then measures any changes in absorption due to the tracer compounds when they enter the measurement path. The shape of absorption features is used to distinguish and identify the different tracer compounds, and the strength of the absorption is used to determine the path-integrated concentration – also called the column density.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Broadband rapid-scanning phase-modulated Fourier transform electronic spectroscopy

We present a phase-modulated approach for ultrabroadband Fourier transform electronic spectroscopy. To overcome the bandwidth limitations and spatial chirp introduced by acousto-optic modulators (AOMs), pulses from a 1 µm laser are modulated using AOMs prior to continuum generation. This phase modulation is transferred to the continuum generated in a yttrium aluminum garnet crystal. Separately generated phase-modulated continua in two arms of a Mach-Zehnder interferometer interfere with the difference of their modulation frequencies, enabling physical under-sampling of the signal and the suppression of low-frequency noise. By interferometrically tracking the relative time delay of the continua, we perform continuous, rapid-scanning Fourier transform electronic spectroscopy with a high signal-to-noise ratio and spectral resolution. As proof of principle, we measure the linear absorption and fluorescence excitation spectra of a laser dye and various biological samples.

Javed, Ariba↗

A Novel Fault Diagnosis Approach for Rolling Bearing Based on CWT and Adaptive Sparse Representation

Extraction and enhancement of weak impulse signature is the key of rolling bearing fault prognostics in which case the features are often weak and covered by noise. Tunable Q-factor wavelet transform (TQWT), as an emerging wavelet construction theory developed in a frequency domain explicitly, has the advantages of matching with the specific oscillation behavior of signal components. In this article, an adaptive sparse representation (ASR) method is proposed, which integrates the sparse code shrinkage (SCS) and parameter optimization into TQWT. However, direct application of ASR is difficult to extract fault signatures at the early stage or low-speed operation due to weak fault symptoms and background noise. A novel fault diagnosis strategy based on continuous wavelet transform (CWT) and ASR is investigated. CWT owns significant advantages on multiscale subdivision and weak signal detection. The results of simulated and experimental vibration signal analyses verify the effectiveness of the proposed method in accurately extracting weak impulse features from the noise environment.

Yuan, Xing↗

Robust analytic continuation of Green's functions via projection, pole estimation, and semidefinite relaxation

Green's functions of fermions are described by matrix-valued Herglotz-Nevanlinna functions. Since analytic continuation is fundamentally an ill-posed problem, the causal space described by the matrix-valued Herglotz-Nevanlinna structure can be instrumental in improving the accuracy and in enhancing the robustness with respect to noise. We demonstrate a three-pronged procedure for robust analytic continuation called PES: (1) projection of data to the causal space; (2) estimation of pole locations; and (3) semidefinite relaxation within the causal space. We compare the performance of PES with the recently developed Nevanlinna and Carathéodory continuation methods and find that PES is more robust in the presence of noise and does not require the usage of extended precision arithmetics. We also demonstrate that a causal projection improves the performance of the Nevanlinna and Carathéodory methods. The PES method is generalized to bosonic response functions, for which the Nevanlinna and Carathéodory continuation methods have not yet been developed. Furthermore, it is particularly useful for studying spectra with sharp features, as they occur in the study of molecules and band structures in solids.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Scattering Matrix Determination in Crystalline Materials from 4D Scanning Transmission Electron Microscopy at a Single Defocus Value

Recent work has revived interest in the scattering matrix formulation of electron scattering in transmission electron microscopy as a stepping stone toward atomic-resolution structure determination in the presence of multiple scattering. Here, we discuss ways of visualizing the scattering matrix that make its properties clear. Through a simulation-based case study incorporating shot noise, we shown how regularizing on this continuity enables the scattering matrix to be reconstructed from 4D scanning transmission electron microscopy (STEM) measurements from a single defocus value. Intriguingly, for crystalline samples, this process also yields the sample thickness to nanometer accuracy with no a priori knowledge about the sample structure. The reconstruction quality is gauged by using the reconstructed scattering matrix to simulate STEM images at defocus values different from that of the data from which it was reconstructed.

36 MATERIALS SCIENCE↗

Continuous automatic polarization channel stabilization from heterodyne detection of coexisting dim reference signals

Quantum networking continues to encode information in polarization states due to ease and precision. The variable environmental polarization transformations induced by deployed fiber need correction for deployed quantum networking. Here, we present a method for automatic polarization compensation (APC) and demonstrate its performance on a metropolitan quantum network. Designing an APC involves many design decisions as indicated by the diversity of previous solutions in the literature. Our design leverages heterodyne detection of wavelength-multiplexed dim classical references for continuous high-bandwidth polarization measurements used by newly developed multi-axis (non-)linear control algorithm(s) for complete polarization channel stabilization with no downtime. This enables continuous relatively high-bandwidth correction without significant added noise from classical reference signals. We demonstrate the performance of our APC using a variety of classical and quantum characterizations. Finally, we use C-band and L-band APC versions to demonstrate continuous high-fidelity entanglement distribution on a metropolitan quantum network with an average relative fidelity of 0.94 ± 0.03 for over 30 hrs.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Floquet Prethermalization with Lifetime Exceeding 90 s in a Bulk Hyperpolarized Solid

Here, we report the observation of long-lived Floquet prethermal states in a bulk solid composed of dipolar-coupled 13 C nuclei in diamond at room temperature. For precessing nuclear spins prepared in an initial transverse state, we demonstrate pulsed spin-lock Floquet control that prevents their decay over multiple-minute-long periods. We observe Floquet prethermal lifetimes $T^{'}_{2}$≈90.9 s, extended >60 000-fold over the nuclear free induction decay times. The spins themselves are continuously interrogated for ~10 min, corresponding to the application of ≈5.8×10 6 control pulses. The 13 C nuclei are optically hyperpolarized by lattice nitrogen vacancy centers; the combination of hyperpolarization and continuous spin readout yields significant signal-to-noise ratio in the measurements. This allows probing the Floquet thermalization dynamics with unprecedented clarity. We identify four characteristic regimes of the thermalization process, discerning short-time transient processes leading to the prethermal plateau and long-time system heating toward infinite temperature. This Letter points to new opportunities possible via Floquet control in networks of dilute, randomly distributed, low-sensitivity nuclei. In particular, the combination of minutes-long prethermal lifetimes and continuous spin interrogation opens avenues for quantum sensors constructed from hyperpolarized Floquet prethermal nuclei.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Large-scale real-time signal processing in physics experiments: the ALICE TPC FPGA pipeline

For LHC Run 3, the ALICE Time Projection Chamber was upgraded to operate in continuous readout mode. Interaction rates of up to 50 kHz in Pb-Pb collisions require real-time processing of more than 3 TB s -1 of raw detector data. This requirement is met by a custom FPGA-based processing pipeline that performs the complete front-end data treatment fully in-stream, including common-mode correction, pedestal subtraction, ion-tail filtering, zero suppression, and dense data packing. A central element of the design is a highly parallel common-mode correction algorithm operating directly on the streaming data. It robustly identifies signal-free readout channels on a time-bin basis and applies pad-dependent scaling to compensate for local variations in capacitive coupling in the GEM readout. In combination with pedestal subtraction and ion-tail filtering, this enables accurate baseline restoration under extreme high-occupancy conditions, preventing signal loss while efficiently suppressing noise prior to zero suppression. The pipeline operates continuously at the full detector bandwidth and reduces the raw input rate of approximately 3 TB s -1 to about 900 GBps for Pb-Pb collisions at the target interaction rate. Overall, it represents a large-scale FPGA-based real-time signal-processing implementation for high-energy physics detector readout.

Digital signal processing (DSP)↗

Differentially Private Adaptive Noise Injection (DP-ANI) v1.0

Location data is collected from users continuously to understand their mobility patterns. Releasing the user trajectories may compromise user privacy. Therefore, the general practice is to release aggregated location datasets. However, private information may still be inferred from an aggregated version of location trajectories. Differential privacy (DP) protects the query output against inference attacks regardless of background knowledge. This software implements a differential privacy-based privacy model that protects the user's origins and destinations from being inferred from aggregated mobility datasets. This is achieved by injecting Planar Laplace noise to the user origin and destination GPS points. The noisy GPS points are then transformed into a link representation using a link-matching algorithm. Finally, the link trajectories form an aggregated mobility network. The injected noise level is selected using the Sparse Vector Mechanism. This DP selection mechanism considers the link density of the location and the functional category of the localized links. Compared to the different baseline models, including a k-anonymity method, our differential privacy-based aggregation model offers query responses that are close to the raw data in terms of aggregate statistics at both the network and trajectory-levels with maximum 9% deviation from the baseline in terms of network length.

Peisert, Sean [Lawrence Berkeley National Laborato↗

Tracer-field cross-correlations with k -nearest neighbour distributions

ABSTRACT In astronomy and cosmology significant effort is devoted to characterizing and understanding spatial cross-correlations between points – e.g galaxy positions, high energy neutrino arrival directions, X-ray and AGN sources, and continuous fields – e.g. weak lensing meiand Cosmic Microwave Background maps. Recently, we introduced the k-nearest neighbour (kNN) formalism to better characterize the clustering of discrete (point) data sets. Here, we extend it to the point – field cross-correlations analysis. It combines kNN measurements of the point data set with measurements of the field smoothed at many scales. The resulting statistics are sensitive to all orders in the joint clustering of the points and the field. We demonstrate that this approach, unlike the 2-pt cross-correlation, can measure the statistical dependence of two data sets even when there are no linear (Gaussian) correlations between them. We further demonstrate that this framework is far more effective than the two point function in detecting cross-correlations when the continuous field is contaminated by high levels of noise. For a particularly high level of noise, the cross-correlation between haloes and the underlying matter field in a cosmological simulation, between 10 h−1 Mpc and 30 h−1 Mpc, is detected at >5σ significance using the technique presented here, when the two-point cross-correlation significance is ∼1σ. Finally, we show that kNN cross-correlations of haloes and the matter field can be well modelled on quasi-linear scales using the Hybrid Effective Field Theory (HEFT) framework, with the same set of bias parameters as are used for 2-pt cross-correlations. The substantial improvement in the statistical power of detecting cross-correlations using this method makes it a promising tool for various cosmological applications.

79 ASTRONOMY AND ASTROPHYSICS↗

Experimental demonstration of continuous quantum error correction

The storage and processing of quantum information are susceptible to external noise, resulting in computational errors. A powerful method to suppress these effects is quantum error correction. Typically, quantum error correction is executed in discrete rounds, using entangling gates and projective measurement on ancillary qubits to complete each round of error correction. Here we use direct parity measurements to implement a continuous quantum bit-flip correction code in a resource-efficient manner, eliminating entangling gates, ancillary qubits, and their associated errors. An FPGA controller actively corrects errors as they are detected, achieving an average bit-flip detection efficiency of up to 91%. Furthermore, the protocol increases the relaxation time of the protected logical qubit by a factor of 2.7 over the relaxation times of the bare comprising qubits. Our results showcase resource-efficient stabilizer measurements in a multi-qubit architecture and demonstrate how continuous error correction codes can address challenges in realizing a fault-tolerant system.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Characterization of 128 × 128 MM-PAD-2.1 ASIC: a fast framing hard x-ray detector with high dynamic range

Here, we characterize a new x-ray Mixed-Mode Pixel Array Detector (MM-PAD-2.1) Application Specific Integrated Circuit (ASIC). Using an integrating pixel front-end with dynamic charge removal architecture, the MM-PAD-2.1 ASIC extends the maximum measurable x-ray signal (in 20 keV photon units) to > 10 7 x-rays/pixel/frame while maintaining a low read noise across the full dynamic range, all while imaging continuously at a frame rate of up to 10 kHz. The in-pixel dynamic charge removal mechanism prevents saturation of the input amplifier and proceeds in parallel with signal integration to achieve deadtime-less measurements with incident x-ray rates of > 10 10 x-rays/pixel/s. The ASIC format consists of 128 × 128 square pixels each 150 μm on a side and is designed to be 3-side buttable so large arrays can be effectively tiled. Here we use both laboratory x-ray sources and the Cornell High Energy Synchrotron Source (CHESS) to characterize two single ASIC prototype detectors for both low (single x-ray) and high incident flux detection. In the first detector the ASIC was solder bump-bonded to a 500 μm thick Si sensor for efficient detection of x-rays below 20 keV, whereas the second detector used a 750 μm thick CdTe sensor for x-rays above ~20 keV.

36 MATERIALS SCIENCE↗

S AP F LOWER : an automated tool for sap flow data preprocessing, gap-filling, and analysis using deep learning

Sap flow, a critical process in plant water use and ecosystem water cycles, is often measured using thermal dissipation probes (TDP) due to their ease of installation and continuous data collection. However, sap flow data frequently include noise, outliers, and gaps, creating challenges for analysis and requiring substantial manual processing. We developed S AP F LOWER , a tool that automates data preprocessing, model training, gap-filling, sapwood area scaling and modeling, and water use analysis. It integrates autocleaning, machine learning and deep learning models (e.g. random forest, Gaussian process regression, long short-term memory (LSTM), bidirectional LSTM (BiLSTM)), and efficient workflows to process sap flow data. S AP F LOWER can remove over 90% of noisy data while preserving legitimate variations and achieve high accuracy in gap-filling based on user-determined parameters. Random forest, LSTM, and BiLSTM models reduced root mean square error to 10% or less for long-term gaps. Model training and prediction can be performed efficiently within seconds. S AP F LOWER significantly enhances the efficiency and accessibility of TDP data analysis by automating complex tasks, enabling researchers without programming expertise to employ advanced techniques. Future improvements will focus on species-specific corrections for TDP and support for additional measurement methods. S AP F LOWER is openly available on GitHub (https://github.com/JiaxinWang123/SapFlower) and Zenodo (doi: 10.5281/zenodo.13665919).

ecosystem water balance↗

Correspondence: A new two-step approach for evaluating discomfort from glare

While there are several rating scales commonly used to measure discomfort from glare sources, there are issues in the design of these scales that lead to noise in the data and in turn contribute to continued disagreement about the prediction of discomfort. Problems with rating scales include uncertainty about the meaning of magnitude descriptors, limited analysis opportunities available for some rating scales, inconsistent labelling of scale descriptors between studies that are using the “same” scale, the inability for subjects to indicate the lack of discomfort, and that it is uncertain where lies the borderline between comfort and discomfort. This paper proposes a new two-step scale for rating discomfort from glare.

99 GENERAL AND MISCELLANEOUS↗

Polarization Angle Swings in Blazars Detected in the Millimeter-wave with the South Pole Telescope

We present the first systematic search for electric vector position angle (EVPA) swings in the millimeter-wave (mm-wave) emission of blazars, using five years of observations from the South Pole Telescope SPT-3G camera at 95 and 150 GHz, and investigate their connection to gamma-ray flares. Of the 168 bright sources in the ~1500 square degrees SPT-3G Main Field, eight have sufficient polarization signal-to-noise for reliable EVPA measurement, four of which have continuous Fermi LAT gamma-ray detections. We detect EVPA swings in all four gamma-ray-active blazars and in none of the remaining four, consistent with the established connection between EVPA swings and high-energy emission seen at optical wavelengths. The observed swing amplitudes and rotation rates are smaller than those found in optical studies, consistent with mm-wave EVPA variability being slower than at shorter wavelengths. Random walk simulations of the polarization angle using a multi-cell model fail to reproduce both the number, amplitude, and duration of the observed swings, suggesting that this mechanism is insufficient to explain the observed swing population. Analysis of EVPA variability on one-week timescales is consistent with the anti-correlation between polarization degree and EVPA rotation rate previously observed at optical wavelengths. Of the 14 detected swings, eight are within 30 days of a gamma-ray flare. While many individual swing-flare associations are found to have a very low probability of happening by chance, the full ensembles of 95 and 150 GHz swing time lags with respect to gamma-ray flares are found to be consistent with random coincidence.

Simpson, A. [Chicago U., Astron. Astrophys. Ctr.; ↗

Remote Sensing Low Signal-to-Noise-Ratio Target Detection Enhancement

In real-time remote sensing application, frames of data are continuously flowing into the processing system. The capability of detecting objects of interest and tracking them as they move is crucial to many critical surveillance and monitoring missions. Detecting small objects using remote sensors is an ongoing, challenging problem. Since object(s) are located far away from the sensor, the target’s Signal-to-Noise-Ratio (SNR) is low. The Limit of Detection (LOD) for remote sensors is bounded by what is observable on each image frame. In this paper, we present a new method, a “Multi-frame Moving Object Detection System (MMODS)”, to detect small, low SNR objects that are beyond what a human can observe in a single video frame. This is demonstrated by using simulated data where our technology-detected objects are as small as one pixel with a targeted SNR, close to 1:1. We also demonstrate a similar improvement using live data collected with a remote camera. The MMODS technology fills a major technology gap in remote sensing surveillance applications for small target detection. Our method does not require prior knowledge about the environment, pre-labeled targets, or training data to effectively detect and track slow- and fast-moving targets, regardless of the size or the distance.

47 OTHER INSTRUMENTATION↗