Search NASA⌕ Search

SEARCH · Search NASA

Results for “CONTROL SURFACES - HINGE MOMENTS”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

39 records · Page 3

Achieving High-Yield Conversion of Janus Transition Metal Dichalcogenides on Diverse Substrates

Janus transition metal dichalcogenides (TMDCs) with intrinsic broken mirror symmetry and vertical dipole moment provide an additional degree of freedom to manipulate material symmetry down to atomic-layer thickness. However, despite advances in synthesis strategies, fundamental understanding of this atomic substitution process remains limited, which has impeded their implementation in advanced devices. Here, by using a room-temperature atomic-layer substitution (RT-ALS) strategy, we systematically investigate the critical factors facilitating the high-yield conversion of Janus TMDCs on diverse substrates. Combining Raman spectroscopy probes, X-ray photoelectron spectroscopy (XPS) measurements, and density functional theory (DFT) calculations, we demonstrate that substrates with enhanced electron doping or larger surface polarity substantially benefit the conversion of Janus TMDCs reaching a near-unity yield. Intriguingly, the strong affinity between Janus TMDCs and substrates (e.g., Au) brings about abnormal Raman spectroscopic phenomena. These findings highlight the significance of substrates in achieving the reliable synthesis of Janus two-dimensional materials with improved homogeneity on various substrates. In addition, this takes us one step closer to utilizing Janus TMDCs as a versatile platform in next-generation optoelectronic devices, sensors, and quantum technologies.

Doping↗

Switching the spin cycloid in BiFeO3 with an electric field

Abstract Bismuth ferrite (BiFeO 3 ) is a multiferroic material that exhibits both ferroelectricity and canted antiferromagnetism at room temperature, making it a unique candidate in the development of electric-field controllable magnetic devices. The magnetic moments in BiFeO 3 are arranged into a spin cycloid, resulting in unique magnetic properties which are tied to the ferroelectric order. Previous understanding of this coupling has relied on average, mesoscale measurements. Using nitrogen vacancy-based diamond magnetometry, we observe the magnetic spin cycloid structure of BiFeO 3 in real space. This structure is magnetoelectrically coupled through symmetry to the ferroelectric polarization and this relationship is maintained through electric field switching. Through a combination of in-plane and out-of-plane electrical switching, coupled with ab initio studies, we have discovered that the epitaxy from the substrate imposes a magnetoelastic anisotropy on the spin cycloid, which establishes preferred cycloid propagation directions. The energy landscape of the cycloid is shaped by both the ferroelectric degree of freedom and strain-induced anisotropy, restricting the spin spiral propagation vector to changes to specific switching events.

36 MATERIALS SCIENCE↗

Effect of Initial Water Saturation on The Performance of Fracturing Fluids With and Without Polyallylamine under Simulated EGS Conditions

Objectives/Scope: StimuFrac (US Patents 9,873,828 B2 and 9,447,315 B2), a CO2-reactive polymer aqueous solution [polyallylamine (PAA) 1wt% in water] combined with CO2, can be used as a less water-intensive fracturing fluid for enhanced geothermal systems (EGS). Our previous results show that in hot dry rock (HDR), PAA/CO2 fracturing fluids outperformed other fluids such as water, CO2, and CO2/water in generating large fractures with less fluid consumed. The objective of this work is to study the effect of initial water saturation of rock on the performance of StimuFrac fluid in ½ foot cubic rock samples and under representative EGS pressure/temperature conditions using cyclic and constant flow rate injection strategies. The fracturing results are compared with results using different fracturing fluids in terms of controlling fracture propagation rates, fracture hydraulic conductivity, breakdown pressures and volumes of fluids required. Methods/Procedures/Process: In all tests, water was initially injected into the rock to increase the water saturation before the fracturing processes to simulate actual geothermal reservoir conditions. For the cyclic injection, one complete cycle consisted of (1) a PAA slug (or water slug) injection followed by (2) CO2 injection to initiate the fracture. In the second step of the first cycle, the pressure of CO2 is increased until a maximum pressure is reached (fracture is initiated at this moment), and then the injection of CO2 is allowed for another 30 seconds to propagate the fracture. Then, the two-step cycle of PAA followed by CO2 injection (up to 2-4 mL/min) was continued. For the constant flow rate injection strategies, the initial water saturation was increased by injecting water at 1000 psi and 200°C for three days. After that, an initial slug of water, CO2, or PAA was injected and then fracturing was initiated and propagated by injecting CO2 at a constant flow rate. Applications/Significance/Novelty: The results of this study suggest that water saturation, especially near the wellbore region, will significantly affect the fracturing fluid transmission into the rock porous media by changing the relative permeability of CO2 or water, thus affecting the fracture initiation and propagation. In this study, fracturing with cyclic injection or constant flow rate injection methods were performed using three different kinds of fluids systems. These fluids are water, CO2, or CO2 with PAA. Splitting the rock samples in half after fracturing reveals that the fracture propagation is significantly limited under these high water saturated conditions compared to dry initial conditions: The fractures propagate less than 1/3 length of the distance from the wellbore to rock surface, and in some cases no fracture is generated. This may be caused by the fact that leak-off is dominating the fracturing process and the injected fluid flow rate is not high enough to overcome the leak-off even under high flow rate injection conditions. Additionally, CO2 could be leaking off into the wellbore annulus and this may be making it more difficult to generate pressure gradients away from the near-wellbore region.

Jian, Guoqing↗