Search NASA⌕ Search

SEARCH · Search NASA

Results for “CONTROL VALVE”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 55 records · Page 3

Mathematical model of the Space Shuttle Main Engine gaseous oxygen control valve

A computer program for modeling transient flow behavior of the GOX control valve (GCV) has been developed which makes it possible to model a variety of operating conditions and changes of physical hardware. The SSME GCV controls the flow of GOX that pressurizes the Pogo accumulator. The model simulates the transient flow behavior of the original, tight stacked, and redesigned valve configurations during start and shutdown. The model reads a user-prepared input file that defines the valve configurations and thus provides maximum flexibility.

Langer, Susan L.↗

Surrogates for Valve-Controlled Pipe Flow: Accelerating Nuclear Reactor Design

Neural surrogate models are developed to replace expensive steady-state RANS CFD simulations for valve-controlled pipe flow in nuclear reactor design. Using parametric CFD data generated with MOOSE Pronghorn across a range of valve geometry and flow conditions, three approaches are compared: a POD-based reduced-order model, a structured UNet on a cylindrical grid, and unstructured models (DeepONet and BiStride MeshGraphNet) on nondimensionalized point clouds. POD achieves the highest accuracy (99%) with fast inference but requires storing all solution snapshots, while the DeepONet and BSMS-GNN both achieve ~89% accuracy at sub-second inference, with the BSMS-GNN offering superior geometric generalizability. These surrogates enable rapid ranking of candidate valve designs and can warm-start CFD solvers to accelerate convergence, supporting agentic design iteration on the Prometheus platform.

42 - ENGINEERING↗

Improved fluid control valve extends diaphragm life

Wear resistance of flexible diaphragms in fluid control valves is increased by incorporating a soft rubber washer at the bottom of the piston, a flexible buffer between the diaphragm and the valve seat, and a fluid feedback arrangement. The stress and wear of components at the valve seat are minimized.

Mac Glashan, W. F.↗

Control valve: Hot gas fast response

The design of a warm gas control valve is reviewed outlining the problems posed by the requirement for extremely fast response combined with a severe environment and a hot, dirty, and corrosive operating fluid.

Hollis, J. T.↗

Lessons Learned from the Space Shuttle Engine Hydrogen Flow Control Valve Poppet Breakage

The Main Propulsion System (MPS) uses three Flow Control Valves (FCV) to modulate the flow of pressurant hydrogen gas from the Space Shuttle Main Engines (SSME) to the hydrogen External Tank (ET). This maintains pressure in the ullage volume as the liquid level drops, preserving ET structural integrity and assuring the engines receive a sufficient amount of head pressure. On Space Transportation System (STS)-126 (2009), with only a handful of International Space Station (ISS) assembly flights from the end of the Shuttle program, a portion of a single FCV?s poppet head broke off at about a minute and a half after liftoff. The risk of the poppet head failure is that the increased flow area through the FCV could result in excessive gaseous hydrogen flow back to the external tank, which could result in overboard venting of hydrogen ullage pressure. If the hydrogen venting were to occur in first stage (i.e., lower atmosphere), a flammability hazard exists that could lead to catastrophic loss of crew and vehicle. Other failure risks included particle impact damage to MPS downstream hardware. Although the FCV design had been plagued by contamination-related sluggish valve response problems prior to a redesign at STS-80 (1996), contamination was ruled out as the cause of the STS-126 failure. Employing a combination of enhanced hardware inspection and a better understanding of the consequences of a poppet failure, safe flight rationale for subsequent flights (STS-119 and later) was achieved. This paper deals with the technical lessons learned during the investigation and mitigation of this problem at a time when assembly flights were each in the critical path to Space Station success.

Martinez, Hugo E.↗

A review on the sizing and selection of control valves for thermal hydraulics for reactor system applications

This study presents an overview regarding how to model/size, choose, and maintain control valves (CVs) for a reactor system thermal hydraulics experimentation—specifically simulating pipe break(s) and a loss of coolant accident (LOCA) analysis. In a thermal hydraulics test loop, CVs modulate fluid flow according to the control signal generated by the controller to control the process parameter. The selection of a CV in industrial applications involves many factors, including process diversity, safety, and reliability. Further, the key issues and challenges for performing proper mathematical modeling, installation, servicing, and calibration are also discussed for the benefit of operators and end-users. Additionally, this research includes case studies illustrating major plant-level accidents associated with the malfunctioning of valves. Therefore, the study will serve as a knowledge base or reference guide for young professionals and operators who wish to better understand process control applications.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Bypass control valve seal and bearing life cycle test report

The operating characteristics of a bypass control valve seal and bearing life cycle tests are reported. Data from the initial assembly, leak, torque, and deflection tests are included along with the cycle life test results and conclusions. The equipment involved was to be used in the nuclear engine for the rocket vehicles program.

Lundback, A. V.↗

Failure Analysis of Fractured Poppet from Space Shuttle Orbiter Flow Control Valve

This slide presentation reviews the failure analysis of a fractured poppet from a flow control valve (FCV) used on the space shuttle. This presentation has focused on the laboratory analysis of the failed hardware. The use of Scanning electron fractography during the investigation led to the conclusion that the poppet failed due to fatigue cracking that, most likely, occurred under changing loading conditions. The initial investigation led to a more thorough test of poppets that had been retired, this testing led to the conclusion that the thumbnail cracks in the flight hardware had existed for the life of the shuttle program. This led to a program to develop an eddy current technique that was capable of detecting small very tight cracks.

Russell, Richard↗

Control Valve Trajectories for SOFC Hybrid System Startup

Control and management of cathode airflow in a solid oxide fuel cell gas turbine hybrid power system was analyzed using the Hybrid Performance (HyPer) hardware simulation at the National Energy Technology (NETL), U.S. Department of Energy. This work delves into previously unexplored operating practices for HyPer, via simultaneous manipulation of bypass valves and the electric load on the generator. The work is preparatory to the development of a Multi-Input, Multi-Output (MIMO) controller for HyPer. A factorial design of experiments was conducted to acquire data for 81 different combinations of the manipulated variables, which consisted of three air flow control valves and the electric load on the turbine generator. From this data the response surface for the cathode airflow with respect to bypass valve positions was analyzed. Of particular interest is the control of airflow through the cathode during system startup and during large load swings. This paper presents an algorithm for controlling air mass flow through the cathode based on a modification of the steepest ascent method.

30 DIRECT ENERGY CONVERSION↗

Coolant-Control Valves For Fluid-Sampling Probes

Small built-in leaks prevent overheating. Downstream flow-control globe valve replaced with modified gate valve. Modification consists of drilling small hole through valve gate, so valve never turned completely off. This "leaky" valve provides enough flow of coolant to prevent overheating causing probe to fail. Principle also applied to automatic control system by installing small bypass line around control valve.

Schultz, Donald F.↗

Analysis of the STS-126 Flow Control Valve Structural-Acoustic Coupling Failure

During the Space Transportation System mission STS-126, one of the main engine's flow control valves incurred an unexpected failure. A section of the valve broke off during liftoff. It is theorized that an acoustic mode of the flowing fuel, coupled with a structural mode of the valve, causing a high cycle fatigue failure. This report documents the analysis efforts conducted in an attempt to verify this theory. Hand calculations, computational fluid dynamics, and finite element methods are all implemented and analyses are performed using steady-state methods in addition to transient analysis methods. The conclusion of the analyses is that there is a critical acoustic mode that aligns with a structural mode of the valve

Jones, Trevor M.↗

Computational Analysis of Cryogenic Flow Through a Control Valve

The initial efforts to develop the capability to model valves used in rocket engine component testing at Stennis Space Center are documented. An axisymmetric model of a control valve with LN2 as the working fluid was developed. The goal was to predict the effect of change in the plug/sear region of the valve prior to testing. The valve flow coefficient was predicted for a range of plug positions. Verification of the calculations was carried out to quantify the uncertainty in the numerical answer. The modeled results compared well qualitatively to experimental trends. Additionally, insights into the flow processes in the valve were obtained. Benefits from the verification process included the ability to use coarser grids and insight into ways to reduce computational time by using double precision accuracy and non-integer grid ratios. Future valve modeling activities will include shape optimization of the valve/seat region and dynamic grid modeling.

Danes, Russell↗

Loop Heat Pipe with Thermal Control Valve as a Variable Thermal Link

Future lunar landers and rovers will require variable thermal links that allow for heat rejection during the lunar daytime and passively prevent heat rejection during the lunar night. During the lunar day, the thermal management system must reject the waste heat from the electronics and batteries to maintain them below the maximum acceptable temperature. During the lunar night, the heat rejection system must either be shut down or significant amounts of guard heat must be added to keep the electronics and batteries above the minimum acceptable temperature. Since guard heater power is unfavorable because it adds to system size and complexity, a variable thermal link is preferred to limit heat removal from the electronics and batteries during the long lunar night. Conventional loop heat pipes (LHPs) can provide the required variable thermal conductance, but they still consume electrical power to shut down the heat transfer. This innovation adds a thermal control valve (TCV) and a bypass line to a conventional LHP that proportionally allows vapor to flow back into the compensation chamber of the LHP. The addition of this valve can achieve completely passive thermal control of the LHP, eliminating the need for guard heaters and complex controls.

Hartenstine, John↗

Dual-Use Partnership Addresses Performance Problems with "Y" Pattern Control Valves

A Dual-Use Cooperative Agreement between the Propulsion Test Directorate (PTD) at Stennis Space Center (SSC) and Oceaneering Reflange, Inc. of Houston, TX has produced an improved 'Y' pattern split-body control valve for use in the propulsion test facilities at Stennis Space Center. The split-body, or clamped bonnet technology, provides for a 'cleaner' valve design featuring enhanced performance and increased flow capacity with extended life expectancy. Other points addressed by the partnership include size, weight and costs. Overall size and weight of each valve will be reduced by 50% compared to valves currently in use at SSC. An initial procurement of two 10 inch valves will result in an overall cost reduction of 15% or approximately $50,000 per valve.

Bailey, John W.↗

"Non-Reflective" Boundary Design via Remote Sensing and PID Control Valve

This paper develops the concept of a nonreflective (or semireflective) boundary condition using the combination of a remote sensor and a control system to modulate a relief valve. The essential idea is to sense the pressure change at a remote location and then to use the measured data to adjust the opening of an active control valve at the end of the line to eliminate or attenuate the wave reflections at the valve, thus controlling system transient pressures. This novel idea is shown here through numerical simulation to have considerable potential for transient protection. Using this model, wave reflections and resonance can be effectively eliminated for frictionless pipelines or initial no-flow conditions and can be better controlled in more realistic pipelines for a range of transient disturbances. In addition, the features of even-order harmonics and nonreflective boundary conditions during steady oscillation, obtained through time domain transient analysis, are verified by hydraulic impedance analysis in the frequency domain.

42 ENGINEERING↗