At least 55 records · Page 3

Effect of oxygen, methyl mercaptan, and methyl chloride on friction behavior of copper-iron contacts

Sliding friction experiments were conducted with an iron rider on a copper disk and a copper rider on an iron disk. The sputter cleaned iron and copper disk surfaces were saturated with oxygen, methyl mercaptan, and methyl chloride at atmospheric pressure. Auger emission spectroscopy was used to monitor the surfaces. Lower friction was obtained in all experiments with the copper rider sliding on the iron disk than when the couple was reversed. For both iron and copper disks, methyl mercaptan gave the best surface coverage and was most effective in reducing friction. For both iron and copper disks, methyl chloride was the least effective in reducing friction. With sliding, copper transferred to iron and iron to copper.

Buckley, D. H.↗

Catalytic Borylation of Poly(vinyl chloride) Produces Adhesive Materials

Postpolymerization functionalization of polymers can create new applications for existing materials, while retaining their most favorable, intrinsic properties. Polyvinyl chloride (PVC) is a widely used, commodity polymer that is particularly challenging to modify. We report a copper-catalyzed protocol that replaces a small fraction of the C-Cl bonds in PVC with C-B bonds to boronic esters. The reaction occurs with an inexpensive catalyst comprising copper(II) chloride and an NHC ligand derived from a common ionic liquid that is distinct from the N-heterocyclic carbene (NHC) used for the borylation of small alkyl halides. The resulting materials adhere strongly to common surfaces, such as glass and metals, even more strongly than do commercial glues.

D’Angelo, Kyan A↗

Doping of CdTe Using CuCl2 Solution for Highly Efficient Photovoltaic Devices

Here, we report doping of cadmium telluride (CdTe) thin film solar cells using copper (II) chloride (CuCl 2 ) solution in deionized water. The CdTe thin films were immersed in 0.1 mmol CuCl 2 solution in water and annealed in the temperature range of 180-240 degrees C for various time durations. The devices were completed using thermally evaporated gold (Au) and measured under simulated AM1.5G spectrum. The average device efficiency of CuCl 2 treated CdTe devices increased to 13.7 % (best cell reaching 14.0%) with significant improvement on open-circuit voltage (VOC ) as compared with 12.4% (best cell 12.7%) for thermally evaporated Cu doped CdTe devices. For CuCl 2 treated CdTe devices, we found higher photoluminescence (PL) intensity and longer carrier life time at room temperature indicating solution based doping offers better control of Cu doping density as compared with evaporated Cu.

14 SOLAR ENERGY↗

Multiple-Wavelength Metal/Halide Laser

Single device produces multiple lasing lines. Laser capable of producing many lasing lines has several reservoirs of halide lasant mixed with chlorides of copper, manganese and iron. Convection-control technique possible to rapidly change from one metal halide to another at maximum energy.

Nerheim, N. M.↗

Density of intercalated graphite fibers

The density of Amoco P-55, P-75, P-100, and P-120 pitch-based graphite fibers and their intercalation compounds with bromine, iodine monochloride, and copper (II) chloride have been measured using a density gradient column. The distribution of densities within a fiber type is found to be a sensitive indicator of the quality of the intercalation reaction. In all cases the density was found to increase, indicating that the mass added to the graphite is dominant over fiber expansion. Density increases are small (less than 10 percent) giving credence to a model of the intercalated graphite fibers which have regions which are intercalated and regions which are not.

Gaier, James R.↗

Density of intercalated graphite fibers

The density of Amoco P-55, P-75, P-100, and P-120 pitch-based graphite fibers and their intercalation compounds with bromine, iodine monochloride, and copper (II) chloride have been measured using a density gradient column. The distribution of densities within a fiber type is found to be a sensitive indicator of the quality of the intercalation reaction. In all cases the density was found to increase, indicating that the mass added to the graphite is dominant over fiber expansion. Density increases are small (less than 10 percent) giving credence to a model of the intercalated graphite fibers which have regions which are intercalated and regions which are not.

Gaier, James R.↗

Copper Iodide-Mediated Synthesis of α-Diimine Ligands from Bis(imidoyl chlorides) and Arylstannanes

Aryl-substitued α-diimines were prepared by employing an operationally simple copper iodide-mediated Stille type coupling between polyfluoro(chloro)aryl tributylstannanes and bis(imidoyl chlorides). Reactions proceed in commercial grade N, N-dimethylformamide (DMF) solvent at 70 ºC and require no additives or bases. Couplings are successful for aryl stannanes possessing two or more fluoro or chloro substituents on the aromatic ring. Products are obtained in moderate to good yields. Furthermore, this methodology allows for a simple synthesis of α-diimine ligands potentially useful in olefin polymerization as well as other catalytic transformations.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Development of an Integrated Thermal Energy Storage Heat Exchanger for Concentrating Solar Power

In this design and development effort a latent-heat energy storage heat exchanger was designed for a 10MW e sCO 2 power plant as a basis for detailed design and testing of a new phase-change heat exchanger technology. High efficiency thermal conductors of graphite foam or folded copper were employed within chloride salt phase-change volumes bounded by alternating high density compact plate-fin heat exchange cells in this new heat exchanger technology. Test articles were constructed at Brayton Energy and tested at Argonne National Laboratory. Copper-conducting samples were constructed and tested at Brayton Energy.

14 SOLAR ENERGY↗

Polyimide/metal composite films via in situ decomposition of inorganic additives - Soluble polyimide versus polyimide precursor

Polyimide-metal oxide (Co3O4 or CuO) composite films have been prepared via in situ thermal decomposition of cobalt (II) chloride or bis(trifluoroacetylacetonato)copper(II). A soluble polyimide (XU-218) and its corresponding prepolymer (polyamide acid) were individually employed as the reaction matrix. The resulting composites exhibited a greater metal oxide concentration at the air interface with polyamide acid as the reaction matrix. The water of imidization that is released during the concurrent polyamide acid cure and additive decomposition is believed to promote metal migration and oxide formation. In contrast, XU-218 doped with either HAuCl4.3H2O or AgNO3 yields surface gold or silver when thermolyzed (300 C).

Rancourt, J. D.↗

Metal fluxes at the sediment–water interface in a free water surface constructed wetland

Metal biogeochemistry in the sediment, water, and the sediment–water interface (SWI) was studied in a free water surface constructed wetland. Concentrations of labile copper (Cu), zinc (Zn), sulfate, chloride, and dissolved organic carbon (DOC) were measured with the diffusive gradients in thin film (DGT) and peeper. A good agreement between peeper- and DGT-measured metals was observed for Cu (regression r 2 = 0.3, 95% CI of the slopes > 0), but not for Zn (95% CI of the slopes overlapped with 0), which was attributed to the different complexed compounds between Cu and Zn in porewater. The depth profile of labile metals in sediment porewater varied with time and was consistent with the solid-phase metal deposition, showing higher concentrations in the surface layer (3 to –3 cm) than in the bottom layer (–4 to –13 cm). The depth-averaged labile Cu and Zn concentrations measured by DGT were 1.0 and 3.1 µg/L, and labile sulfate, chloride, and DOC concentrations measured by peeper were 1.8, 3.6, and 2.1 mg/L, respectively. A sharp decrease in sulfate occurred in September when sulfate concentrations became the lowest among sampling months. This was caused by the seasonal sulfur cycles in the wetland, where the dominant sulfur reaction is sulfate reduction in warm seasons and sulfide oxidation in cold seasons. Different metal-removal mechanisms were observed in the two wetland cells; sulfur dynamics controlled the removal processes in the cell without frequent disturbance but failed to influence metal removal in the cell with frequent disturbance due to the interruption of anoxic layers. The flux ratios that compare labile element concentrations between the water column and the SWI (R-Cu, R-Zn, R-DOC, R-sulfate, and R-chloride) were generated to determine metal diffusive fluxes at the interface. Labile Zn was mostly transported from the water to the SWI during all seasons (R-Zn < 1 for all months except January). Labile Cu moved from the SWI to the water during the warm months (R-Cu < 1), which was explained by the bioturbation-induced transport of organic matter based on the positive correlations between R-Cu and R-DOC. In general, sediment can serve either as a sink or a source depending on the environmental conditions, metal speciation, and presence of living organisms. Here, metal flux at the SWI is a key component in the biogeochemical cycling of a constructed wetland.

54 ENVIRONMENTAL SCIENCES↗

Natural abundance nitrate isotopes from Rifle and the East River Watershed, Colorado

This data package provides data on the natural abundance isotopes of nitrate from various sources, including porewater, stream, and precipitation. The overall purpose of this data package is to complement additional data streams for nitrogen cycling metrics (e.g., riverine inorganic and organic nitrogen measurements) with specific data gleaned from the interpretation of terrestrial and riverine isotope measurements and collectively understand on how nitrogen is cycled around this system. The Rifle and East River are part of the Watershed Function Scientific Focus Area (WFSFA) located in the Upper Colorado River Basin, United States. Collection locations include: Pumphouse (multiple sampling dates), River (upstream/ downstream meander C), Shallow soil lysimeters (hillslope, toeslope, floodplain), Hillslope-floodplain borehole wells (i.e., Pumphouse Lower Montane (PLM) wells), and Potassium chloride(KCL)-extracted soil samples. Copper Creek sampling includes 8x river sample points and two tributaries sampled on Sept. Oct. 2017, July 2018. East River below the Rocky Mountain Biological Laboratory sampling includes 1 access point sampled on July, Sept. Oct. 2017. Rifle floodplain sampling includes well TT03 across multiple collection times over 2014. Data is provided in 5 individual files by location in csv format, or all compiled in Excel format.

54 ENVIRONMENTAL SCIENCES↗

Electrically Conducting Polymer-Copper Sulphide Composite Films, Preparation by Treatment of Polymer-Copper (2) Acetate Composites with Hydrogen Sulfide

Polymer copper sulfide composite films were prepared by treatment of polymer poly(vinyl chloride), poly(acrylonitrile), copolymer of vinyl chloride and vinyl acetate (90:10), and ABS resin copper (2) acetate composites with hydrogen sulfide. The films showed electrical conductivity higher than 0.015 S/cm when they contained more than 20 wt percent of copper sulfide. A poly(acrylonitrile)-copper sulfide composite film containing 40 to 50 wt percent of copper sulfide showed electrical conductivity of 10 to 150.0 S/cm and had relatively high mechanical strength to be used in practical purposes.

Yamamoto, Takakazu↗

Mechanistic modeling of copper corrosions in data center environments

Air-side economizers are increasingly used to take advantage of “free-cooling” in data centers with the intent of reducing the carbon footprint of buildings. However, they can introduce outdoor pollutants to indoor environment of data centers and cause corrosion damage to the information technology equipment. Here, to evaluate the reliability of information technology equipment under various thermal and air-pollution conditions, a mechanistic model based on multi-ion transport and chemical reactions was developed. The model was used to predict Cu corrosion caused by Cl2-containing pollutant mixtures. It also accounted for the effects of temperature (25 °C and 28 °C), relative humidity (50%, 75%, and 95%), and synergism. It also identified higher air temperature as a corrosion barrier and higher relative humidity as a corrosion accelerator, which agreed well with the experimental results. The average root mean square error of the prediction was 13.7 Å. The model can be used to evaluate the thermal guideline for data centers design and operation when Cl2 is present based on pre-established acceptable risk of corrosion in data centers’ environment.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Controlled etching of printed-circuit boards

Ferric chloride in an aqueous medium etches copper from the surface of printed-circuit boards. Ferric ions are reduced to ferrous ions resulting in a reduced etching rate.

Kovell, S. P.↗

Impact of Indium Chloride Treatment on the Properties of CuInSe 2 Thin Films

Copper Indium diselenide (CIS) semiconductor thin films were deposited by single-stage process. Following the deposition, annealing and recrystallization of CIS was carried out in the presence of InCl 3 at different temperatures. Increase in grain size was observed by SEM in all cases. Increase in peak intensity was observed by XRD after treatment, correlating well with the SEM results. Measurements of the composition by both XRF and EDS indicate significant changes, notably a decrease in copper content. Here, this will likely be an issue for device performance and will need to be addressed.

14 SOLAR ENERGY↗