Search NASA⌕ Search

SEARCH · Search NASA

Results for “CORK method”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

48 records · Page 3

Intelligent Computer Vision System for Automated Classification

In this paper we investigate an Intelligent Computer Vision System applied for recognition and classification of commercially available cork tiles. The system is capable of acquiring and processing gray images using several feature generation and analysis techniques. Its functionality includes image acquisition, feature extraction and preprocessing, and feature classification with neural networks (NN). We also discuss system test and validation results from the recognition and classification tasks. The system investigation also includes statistical feature processing (features number and dimensionality reduction techniques) and classifier design (NN architecture, target coding, learning complexity and performance, and training with our own metaheuristic optimization method). The NNs trained with our genetic low-discrepancy search method (GLPtauS) for global optimisation demonstrated very good generalisation abilities. In our view, the reported testing success rate of up to 95% is due to several factors: combination of feature generation techniques; application of Analysis of Variance (ANOVA) and Principal Component Analysis (PCA), which appeared to be very efficient for preprocessing the data; and use of suitable NN design and learning method.

97 MATHEMATICS AND COMPUTING↗

Thermal Analysis of an In-Space Heat Shield Exposed to a Rocket Plume During Stage Separation

Thermal analyses were conducted to evaluate the thermal response of various individual materials and multi-layer configurations for an in-space heat shield exposed to a rocket plume during stage separation. Frequently used, readily available thermal protection materials consisting of cork, carbon cloth phenolic (CCP), and silica cloth phenolic (SCP) were selected for an initial screening analysis. SCP was chosen as the primary material for further evaluation using an updated thermal environment calculated using computational fluid dynamics (CFD) results. A multi-layer configuration consisting of SCP providing erosion resistance and a Nomex honeycomb providing thermal protection was then evaluated as a solution for more mass-efficient performance. Pyrolysis depth, bondline temperature, back-side temperature, and a thermal factor of safety were used to define the necessary material thickness profile. Adhesives were included in the analyses with considerations for maximum temperature and application method. One dimensional thermal analyses at several stations along the heat shield surface were performed for the initial screening and follow-on analyses. The methodology used standard processes and computer programs applicable to solid rocket motor internal insulation and nozzle thermal analysis such as Chemical Equilibrium and Applications (CEA), Aerotherm Chemical Equilibrium (ACE), Momentum/Energy Integral Technique (MEIT), and Insulation Thermal Response and Ablation Code (ITRAC). The baseline SCP/Nomex honeycomb multi-layer configuration thermal performance predictions satisfied the objectives with an acceptable mass estimate for the design maturity. The EA9673 film adhesive and SCP resin were the best performing bonding agents considered for the SCP/Nomex honeycomb and Nomex honeycomb/structural substrate interfaces. The baseline mass estimate was lowest when the resin was the bonding agent due to the higher maximum service temperature. These thermal analyses evaluated typical internal and external nozzle materials using a calculated thermal environment and heat loads that were lower than a typical rocket motor internal environment but greater than standard external aeroheating.

Andrew T Hiatt↗

Can radiomics features be reproducibly measured from CBCT images for patients with non-small cell lung cancer?

Purpose: Increasing evidence suggests radiomics features extracted from computed tomography (CT) images may be useful in prognostic models for patients with nonsmall cell lung cancer (NSCLC). This study was designed to determine whether such features can be reproducibly obtained from cone-beam CT (CBCT) images taken using medical Linac onboard-imaging systems in order to track them through treatment. Methods: Test-retest CBCT images of ten patients previously enrolled in a clinical trial were retrospectively obtained and used to determine the concordance correlation coefficient (CCC) for 68 different texture features. The volume dependence of each feature was also measured using the Spearman rank correlation coefficient. Features with a high reproducibility (CCC > 0.9) that were not due to volume dependence in the patient test-retest set were further examined for their sensitivity to differences in imaging protocol, level of scatter, and amount of motion by using two phantoms. The first phantom was a texture phantom composed of rectangular cartridges to represent different textures. Features were measured from two cartridges, shredded rubber and dense cork, in this study. The texture phantom was scanned with 19 different CBCT imagers to establish the features’ interscanner variability. The effect of scatter on these features was studied by surrounding the same texture phantom with scattering material (rice and solid water). The effect of respiratory motion on these features was studied using a dynamic-motion thoracic phantom and a specially designed tumor texture insert of the shredded rubber material. The differences between scans acquired with different Linacs and protocols, varying amounts of scatter, and with different levels of motion were compared to the mean intrapatient difference from the test-retest image set. Results: Of the original 68 features, 37 had a CCC >0.9 that was not due to volume dependence. When the Linac manufacturer and imaging protocol were kept consistent, 4–13 of these 37 features passed our criteria for reproducibility more than 50% of the time, depending on the manufacturer-protocol combination. Almost all of the features changed substantially when scatter material was added around the phantom. For the dense cork, 23 features passed in the thoracic scans and 11 features passed in the head scans when the differences between one and two layers of scatter were compared. Using the same test for the shredded rubber, five features passed the thoracic scans and eight features passed the head scans. Motion substantially impacted the reproducibility of the features. With 4 mm of motion, 12 features from the entire volume and 14 features from the center slice measurements were reproducible. With 6–8 mm of motion, three features (Laplacian of Gaussian filtered kurtosis, gray-level nonuniformity, and entropy), from the entire volume and seven features (coarseness, high gray-level run emphasis, gray-level nonuniformity, sum-average, information measure correlation, scaled mean, and entropy) from the center-slice measurements were considered reproducible. Conclusions: Some radiomics features are robust to the noise and poor image quality of CBCT images when the imaging protocol is consistent, relative changes in the features are used, and patients are limited to those with less than 1 cm of motion.

60 APPLIED LIFE SCIENCES↗

An introduction to PYTHIA 8.2

The Pythia program is a standard tool for the generation of events in high-energy collisions, comprising a coherent set of physics models for the evolution from a few-body hard process to a complex multiparticle final state. It contains a library of hard processes, models for initial- and final-state parton showers, matching and merging methods between hard processes and parton showers, multiparton interactions, beam remnants, string fragmentation and particle decays. It also has a set of utilities and several interfaces to external programs. Pythia 8.2 is the second main release after the complete rewrite from Fortran to C++, and now has reached such a maturity that it offers a complete replacement for most applications, notably for LHC physics studies. The many new features should allow an improved description of data.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Methods and Apparatus for Pulsed-DC Dielectric Barrier Discharge Plasma Actuator and Circuit

A plasma generating device intended to induce a flow in a fluid via plasma generation includes a dielectric separating two electrodes and a power supply. The first electrode is exposed to a fluid flow while the second electrode is positioned under the dielectric. The power supply is electrically coupled to a switch and the first and second electrodes. When the power supply is energized by repeated action of the switch, it causes a pulsed DC current between the electrodes which causes the fluid to ionize generating a plasma. The generation of the plasma induces a force with a velocity component in the fluid.

Corke, Thomas C.↗

A tri-level distribution locational marginal price-based demand response framework

Here, in this paper, we propose a tri-level, nested, two-stage price-based demand response (PBDR) framework that considers distribution locational marginal price (DLMP) as DR enabler between load-serving entities (LSE), demand response providers (DRPs), and customers in the day-ahead distribution market. It enables LSE and customer interactions by using multiple DRPs, positioned in-between, and independently optimizes their objectives. The problem is formulated using linear power flow with approximated power losses and its application in DLMP as DR pricing. The tri-level problem is solved using a nested reformulation & decomposition (R&D) method and tested on the real Indian-108 bus distribution system under various dynamic pricings. Further, the temporal–spatial variations in DLMPs are assessed using fairness criteria. Numerical analyses demonstrate that DLMP applications can effectively improve economic efficiency, and transparency in DR programs valuation with a favorable fairness margin. The results show that DLMP as DR pricing signal induces (0-2) % variation in DLMP for DR participation up to 10 %. Further, it gives over 90 % fairness over temporal–spatial variation for all the customers.

24 POWER TRANSMISSION AND DISTRIBUTION↗

SU-E-J-210: Characterizing Tissue Equivalent Materials for the Development of a Dual MRI-CT Heterogeneous Anthropomorphic Phantom Designed Specifically for MRI Guided Radiotherapy Systems

Purpose: MRI guided radiotherapy (MRIgRT) is an emerging technology which will eventually require a proficient quality auditing system. Due to different principles in which MR and CT acquire images, there is a need for a multi-imaging-modality, end-to-end QA phantom for MRIgRT. The purpose of this study is to identify lung, soft tissue, and tumor equivalent substitutes that share similar human-like CT and MR properties (i.e. Hounsfield units and relaxation times). Methods: Materials of interested such as common CT QA phantom materials, and other proprietary gels/silicones from Polytek, SmoothOn, and CompositeOne were first scanned on a GE 1.5T Signa HDxT MR. Materials that could be seen on both T1-weighted and T2-weighted images were then scanned on a GE Lightspeed RT16 CT simulator and a GE Discovery 750HD CT scanner and their HU values were then measured. The materials with matching HU values of lung (−500 to −700HU), muscle (+40HU) and soft tissue (+100 to +300HU) were further scanned on GE 1.5T Signa HDx to measure their T1 and T2 relaxation times from varying parameters of TI and TE. Results: Materials that could be visualized on T1-weighted and T2-weighted images from a 1.5T MR unit and had an appropriate average CT number, −650, −685, 46,169, and 168 HUs were: compressed cork saturated with water, Polytek Platsil™ Gel-00 combined with mini styrofoam balls, radiotherapy bolus material, SmoothOn Dragon-Skin™ and SmoothOn Ecoflex™, respectively. Conclusion: Post processing analysis is currently being performed to accurately map T1 and T2 values for each material tested. From previous MR visualization and CT examinations it is expected that Dragon-Skin™, Ecoflex™ and bolus will have values consistent with tissue and tumor substitutes. We also expect compressed cork statured with water, and Polytek™-styrofoam combination to have approximate T1 and T2 values suitable for lung-equivalent materials.

60 APPLIED LIFE SCIENCES↗

QUIESCENT PROMINENCE DYNAMICS OBSERVED WITH THE HINODE SOLAR OPTICAL TELESCOPE. I. TURBULENT UPFLOW PLUMES

Hinode/Solar Optical Telescope (SOT) observations reveal two new dynamic modes in quiescent solar prominences: large-scale (20-50 Mm) 'arches' or 'bubbles' that 'inflate' from below into prominences, and smaller-scale (2-6 Mm) dark turbulent upflows. These novel dynamics are related in that they are always dark in visible-light spectral bands, they rise through the bright prominence emission with approximately constant speeds, and the small-scale upflows are sometimes observed to emanate from the top of the larger bubbles. Here we present detailed kinematic measurements of the small-scale turbulent upflows seen in several prominences in the SOT database. The dark upflows typically initiate vertically from 5 to 10 Mm wide dark cavities between the bottom of the prominence and the top of the chromospheric spicule layer. Small perturbations on the order of 1 Mm or less in size grow on the upper boundaries of cavities to generate plumes up to 4-6 Mm across at their largest widths. All plumes develop highly turbulent profiles, including occasional Kelvin-Helmholtz vortex 'roll-up' of the leading edge. The flows typically rise 10-15 Mm before decelerating to equilibrium. We measure the flowfield characteristics with a manual tracing method and with the Nonlinear Affine Velocity Estimator (NAVE) 'optical flow' code to derive velocity, acceleration, lifetime, and height data for several representative plumes. Maximum initial speeds are in the range of 20-30 km s{sup -1}, which is supersonic for a {approx}10,000 K plasma. The plumes decelerate in the final few Mm of their trajectories resulting in mean ascent speeds of 13-17 km s{sup -1}. Typical lifetimes range from 300 to 1000 s ({approx}5-15 minutes). The area growth rate of the plumes (observed as two-dimensional objects in the plane of the sky) is initially linear and ranges from 20,000 to 30,000 km{sup 2} s{sup -1} reaching maximum projected areas from 2 to 15 Mm{sup 2}. Maximum contrast of the dark flows relative to the bright prominence plasma in SOT images is negative and ranges from -10% for smaller flows to -50% for larger flows. Passive scalar 'cork movies' derived from NAVE measurements show that prominence plasma is entrained by the upflows, helping to counter the ubiquitous downflow streams in the prominence. Plume formation shows no clear temporal periodicity. However, it is common to find 'active cavities' beneath prominences that can spawn many upflows in succession before going dormant. The mean flow recurrence time in these active locations is roughly 300-500 s (5-8 minutes). Locations remain active on timescales of tens of minutes up to several hours. Using a column density ratio measurement and reasonable assumptions on plume and prominence geometries, we estimate that the mass density in the dark cavities is at most 20% of the visible prominence density, implying that a single large plume could supply up to 1% of the mass of a typical quiescent prominence. We hypothesize that the plumes are generated from a Rayleigh-Taylor instability taking place on the boundary between the buoyant cavities and the overlying prominence. Characteristics, such as plume size and frequency, may be modulated by the strength and direction of the cavity magnetic field relative to the prominence magnetic field. We conclude that buoyant plumes are a source of quiescent prominence mass as well as a mechanism by which prominence plasma is advected upward, countering constant gravitational drainage.

79 ASTRONOMY AND ASTROPHYSICS↗

A comprehensive academic and industrial survey of blockchain technology for the energy sector using fuzzy Einstein decision-making

The global energy sector is undergoing a significant transformation driven by decarbonization and digitalization, leading to the emergence of Distributed Ledger Technology (DLT) — particularly blockchain — as a promising tool for enhancing transparency, security, and efficiency in modern power systems. This study aims to provide a comprehensive academic and industrial survey of blockchain applications in the energy sector and develop a robust decision-making framework to identify and prioritize the most promising real-world use cases based on multidisciplinary criteria. A three-stage methodology was adopted: (i) a literature and market review encompassing over 300 academic publications and commercial blockchain initiatives in energy, (ii) an in-depth evaluation of the evolution and viability of blockchain initiatives in energy with the help of expert surveys, and (iii) a novel decision-making model using a q-rung orthopair fuzzy Multi-Attributive Border Approximation (q-ROF-MABAC) method under the Einstein operator. The results were compared with existing decision models to validate consistency and robustness. Nine key blockchain use case categories were identified and ranked based on technical, economic, and governance dimensions. The results demonstrated that integrating expert insights into a fuzzy logic framework helps filter out overhyped claims in the literature and prioritize realistic and high-impact applications such as green certificates, grid services, and peer-to-peer energy trading. The model’s rankings remained stable across varying weight configurations, confirming the robustness of the methodology. This study provides an evidence-based decision-support tool for researchers, industry stakeholders, and policymakers to better understand, evaluate, and adopt blockchain technologies in the energy sector.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

WE-FG-207B-01: BEST IN PHYSICS (IMAGING): Abdominal CT with Three K-Edge Contrast Materials Using a Whole-Body Photon-Counting Scanner: Initial Results of a Large Animal Experiment

Purpose: To demonstrate the feasibility of in vivo three-material decomposition techniques using photon-counting CT (PCCT) with possible advantage of resolving arterial and venous flow of an organ simultaneously. Methods: Abdominal PCCT scans were acquired using a prototype whole-body PCCT with four energy thresholds (25/50/75/90keV) in a canine. Bismuth subsalicylate (60 mg) was administered orally one day prior to scanning. Immediately prior to CT scan, gadoteric acid (60 ml, Dotarem, Guerbet) was intravenously injected, followed in ten minutes by a 20mL injection of iodinated contrast (iopamidol 370 mg/mL, Bracco). Scans were acquired every ∼20 seconds, starting from the time of iodine injection. Linear material decomposition was performed using the least mean squares method to create concentration maps of iodine, gadolinium, and bismuth. The method was calibrated to vials with known concentrations of materials placed next to the animal. The accuracy of this method was tested on vials with known concentrations. Results: The material decomposition algorithm’s accuracy was confirmed to be within ±4mM in the test vials. In the animal, we could estimate the concentration of gadolinium in delayed-enhanced phase (10 minutes post-injection) in the abdomen. We could follow the wash-in and wash-out of iodine in arterial, venous, and excretory flow of the kidneys (20s, 80s, and 120s post-iodine injection) while gadolinium was present in the delayed-enhanced phase. Bismuth, which was used as a contrast agent for the gastro-intestinal tract, was easily differentiable from the other two contrast agents in the small intestine. Conclusion: This study shows the feasibility of using photon-counting CT with four energy thresholds to differentiate three k-edge contrast agents in vivo. This can potentially reduce radiation dose to patients by combining arterial and venous phases into a single acquisition.

60 APPLIED LIFE SCIENCES↗

De Novo Design of High‐Affinity Miniprotein Binders Targeting Francisella Tularensis Virulence Factor

Abstract Francisella tularensis poses considerable public health risk due to its high infectivity and potential for bioterrorism. Francisella‐like lipoprotein (Flpp3), a key virulence factor unique to Francisella, plays critical roles in infection and immune evasion, making it a promising target for therapeutic development. However, the lack of well‐defined binding pockets and structural information on native interactions has hindered structure‐guided ligand discovery against Flpp3. Here, we used a combination of physics‐based and deep‐learning methods to design high‐affinity miniprotein binders targeting two distinct sites on Flpp3. We identified four binders for site I with binding affinities ranging between 24–110 nM. For the second site, an initial binder showed a dissociation constant ( K D ) of 81 nM, and subsequent site saturation mutagenesis yielded variants with sub‐nanomolar affinities. Circular dichroism confirmed the topology of designed miniproteins. The X‐ray crystal structure of Flpp3 in complex with a site I binder is nearly identical to the design model (Cα root‐mean‐square deviation (RMSD): 0.9 Å). These designed miniproteins provide research tools to explore the roles of Flpp3 in tularemia and should enable the development of new therapeutic candidates.

Gokce‐Alpkilic, Gizem [Molecular Engineering and S↗

WE-FG-207B-07: Feasibility of Low Dose Lung Cancer Screening with a Whole-Body Photon Counting CT: First Human Results

Purpose: To evaluate the feasibility of using a whole-body photon counting detector (PCD) CT scanner for low dose lung cancer screening compared to a conventional energy integrating detector (EID) system. Methods: Radiation dose-matched EID and PCD scans of the COPDGene 2 phantom and 2 human volunteers were acquired. Phantom images were acquired at different radiation dose levels (CTDIvol: 3.0, 1.5, and 0.75 mGy) and different tube voltages (120, 100, and 80 kVp), while human images were acquired at vendor recommended low-dose lung cancer screening settings. EID and PCD images were compared for quantitative Hounsfield unit accuracy, noise levels, and contrast-to-noise ratios (CNR) for detection of ground-glass nodules (GGNs) and emphysema. Results: The PCD Hounsfield unit accuracy was better for water at all scan parameters, and for lung, GGN and emphysema equivalent regions of interest (ROIs) at 1.5 and 0.75 mGy. PCD attenuation accuracy was more consistent for all scan parameters (all P<0.01), while Hounsfield units for lung, GGN and emphysema ROIs changed significantly for EID with decreasing dose (all P<0.001). PCD showed lower noise levels at the lowest dose setting at 120, 100 and 80 kVp (15.2±0.3 vs 15.8±0.2, P=0.03; 16.1±0.3 vs 18.0±0.4, P=0.003; and 16.1±0.3 vs 17.9±0.3, P=0.001, respectively), resulting in superior CNR for the detection of GGNs and emphysema at 100 and 80 kVp. Significantly lower PCD noise levels were confirmed in volunteer images. Conclusion: PCD provided better Hounsfield unit accuracy for lung, ground-glass, and emphysema-equivalent foams at 1.5 and 0.75 mGy with less variability than EID. Additionally, PCD showed less noise, and higher CNR at 0.75 mGy for both 100 and 80 kVp. PCD technology may help reduce radiation exposure in lung cancer screening while maintaining diagnostic quality.

60 APPLIED LIFE SCIENCES↗