At least 55 records · Page 3

Theoretical model of the polarization Coulomb field scattering in strained AlGaN/AlN/GaN heterostructure field-effect transistors

The theoretical model of the polarization Coulomb field scattering (PCF) caused by the polarization charge density variation at the AlGaN/AlN interface in strained AlGaN/AlN/GaN heterostructure field-effect transistors has been developed. And the theoretical values for the electron drift mobility, which were calculated using the Matthiessen's rule that includes PCF, piezoelectric scattering, polar optical-phonon scattering, and interface roughness scattering, are in good agreement with our experimental values. Therefore, the theoretical model for PCF has been confirmed.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Momentum-space calculation of proton-deuteron scattering including Coulomb and irreducible three-nucleon forces

Three-nucleon scattering equations with irreducible three-nucleon force are solved in momentum-space. The Coulomb interaction between the two protons is included using the method of screening and renormalization. The need for the renormalization of the scattering amplitudes is demonstrated numerically. The Coulomb and Urbana IX three-nucleon force effects on the observables of elastic proton-deuteron scattering and breakup are studied.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

MPRAD: A Monte Carlo and ray-tracing code for the proton radiography in high-energy-density plasma experiments

Proton radiography is used in various high-energy-density (HED) plasma experiments. In this paper, we describe a Monte Carlo and raytracing simulation tool called multimegaelectronvolt proton radiography (MPRAD) that can be used for modeling the deflection of proton beams in arbitrary three dimensional electromagnetic fields as well as the diffusion of the proton beams by Coulomb scattering and stopping power. Specifically, the Coulomb scattering and stopping power models in cold matter and fully ionized plasma are combined using interpolation. We discuss the application of MPRAD in a few setups relevant to HED plasma experiments where the plasma density can play a role in diffusing the proton beams and affecting the prediction and interpretation of the proton images. It is shown how the diffusion due to plasma density can affect the resolution and dynamical range of the proton radiography.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Coulomb impurity scattering in topological insulator thin films

Inter-surface coupling in thin-film topological insulators can reduce the surface state mobility by an order of magnitude in low-temperature transport measurements. The reduction is caused by a reduction in the group velocity and an increased s{sub z} component of the surface-state spin which weakens the selection rule against large-angle scattering. An intersurface potential splits the degenerate bands into a Rashba-like bandstructure. This reduces the intersurface coupling, it largely restores the selection rule against large angle scattering, and the ring-shaped valence band further reduces backscattering by requiring, on average, larger momentum transfer for backscattering events. The effects of temperature, Fermi level, and intersurface potential on the Coulomb impurity scattering limited mobility are analyzed and discussed.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Transverse Emittance Reduction with Tapered Foil

The idea of reducing transverse emittance with tapered energy-loss foil is proposed by J.M. Peterson in 1980s and recently by B. Carlsten. In this paper, we present the physical model of tapered energy-loss foil and analyze the emittance reduction using the concept of eigen emittance. The study shows that, to reduce transverse emittance, one should collimate at least 4% of particles which has either much low energy or large transverse divergence. The multiple coulomb scattering is not trivial, leading to a limited emittance reduction ratio. Small transverse emittances are of essential importance for the accelerator facilities generating free electron lasers, especially in hard X-ray region. The idea of reducing transverse emittance with tapered energy-loss foil is recently proposed by B. Carlsten [1], and can be traced back to J.M. Peterson's work in 1980s [2]. Peterson illustrated that a transverse energy gradient can be produced with a tapered energy-loss foil which in turn leads to transverse emittance reduction, and also analyzed the emittance growth from the associated multiple coulomb scattering. However, what Peterson proposed was rather a conceptual than a practical design. In this paper, we build a more complete physical model of the tapered foil based on Ref. [2], including the analysis of the transverse emittance reduction using the concept of eigen emittance and confirming the results by various numerical simulations. The eigen emittance equals to the projected emittance when there is no cross correlation in beam's second order moments matrix [3]. To calculate the eigen emittances, it requires only to know the beam distribution at the foil exit. Thus, the analysis of emittance reduction and the optics design of the subsequent beam line section can be separated. In addition, we can combine the effects of multiple coulomb scattering and transverse energy gradient together in the beam matrix and analyze their net effect. We find that,when applied to an electron linac or electron beam line, the energy spread increase and angular growth due to multiple scattering are not trivial; as a result, the transverse emittance can only be reduced with a limited ratio, e.g. down to about 65% the original value. The contents of this paper are arranged as follows. In Sec. II, we build the physical model of the tapered foil, derive the transverse eigen emittance and discuss the emittance reduction criteria. In Sec. III, we implement numerical simulations to verify the physical model; and in Sec. IV, we present numerical experiments and subsequent beam line to remove the transverse energy gradient to demonstrate the applicability of such method. Conclusions are given in the last section.

43 PARTICLE ACCELERATORS↗

Pion polarizability in the Nambu-Jona-Lasinio model and possibilities of its experimental studies in Coulomb nuclear scattering

The charge pion polarizability is calculated in the Nambu-Jona-Lasinio model, where the quark loops (in the mean field approximation) and the meson loops (in the 1/N{sub c} approximation) are taken into account. We show that quark loop contribution dominates because the meson loops strongly conceal each other. The sigma-pole contribution (m{sub {sigma}}{sup 2}-t){sup -1} plays the main role and contains strong t-dependence of the effective pion polarizability at the region |t|{>=}4M{sub {pi}}{sup 2}. Possibilities of experimental test of this sigma-pole effect in the reaction of Coulomb nuclear scattering are estimated for the COMPASS experiment.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Experimental validation of the TOPAS Monte Carlo system for passive scattering proton therapy

Purpose: TOPAS (TOol for PArticle Simulation) is a particle simulation code recently developed with the specific aim of making Monte Carlo simulations user-friendly for research and clinical physicists in the particle therapy community. The authors present a thorough and extensive experimental validation of Monte Carlo simulations performed with TOPAS in a variety of setups relevant for proton therapy applications. The set of validation measurements performed in this work represents an overall end-to-end testing strategy recommended for all clinical centers planning to rely on TOPAS for quality assurance or patient dose calculation and, more generally, for all the institutions using passive-scattering proton therapy systems. Methods: The authors systematically compared TOPAS simulations with measurements that are performed routinely within the quality assurance (QA) program in our institution as well as experiments specifically designed for this validation study. First, the authors compared TOPAS simulations with measurements of depth-dose curves for spread-out Bragg peak (SOBP) fields. Second, absolute dosimetry simulations were benchmarked against measured machine output factors (OFs). Third, the authors simulated and measured 2D dose profiles and analyzed the differences in terms of field flatness and symmetry and usable field size. Fourth, the authors designed a simple experiment using a half-beam shifter to assess the effects of multiple Coulomb scattering, beam divergence, and inverse square attenuation on lateral and longitudinal dose profiles measured and simulated in a water phantom. Fifth, TOPAS’ capabilities to simulate time dependent beam delivery was benchmarked against dose rate functions (i.e., dose per unit time vs time) measured at different depths inside an SOBP field. Sixth, simulations of the charge deposited by protons fully stopping in two different types of multilayer Faraday cups (MLFCs) were compared with measurements to benchmark the nuclear interaction models used in the simulations. Results: SOBPs’ range and modulation width were reproduced, on average, with an accuracy of +1, −2 and ±3 mm, respectively. OF simulations reproduced measured data within ±3%. Simulated 2D dose-profiles show field flatness and average field radius within ±3% of measured profiles. The field symmetry resulted, on average in ±3% agreement with commissioned profiles. TOPAS accuracy in reproducing measured dose profiles downstream the half beam shifter is better than 2%. Dose rate function simulation reproduced the measurements within ∼2% showing that the four-dimensional modeling of the passively modulation system was implement correctly and millimeter accuracy can be achieved in reproducing measured data. For MLFCs simulations, 2% agreement was found between TOPAS and both sets of experimental measurements. The overall results show that TOPAS simulations are within the clinical accepted tolerances for all QA measurements performed at our institution. Conclusions: Our Monte Carlo simulations reproduced accurately the experimental data acquired through all the measurements performed in this study. Thus, TOPAS can reliably be applied to quality assurance for proton therapy and also as an input for commissioning of commercial treatment planning systems. This work also provides the basis for routine clinical dose calculations in patients for all passive scattering proton therapy centers using TOPAS.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Decoupling single nanowire mobilities limited by surface scattering and bulk impurity scattering

We demonstrate the isolation of two free carrier scattering mechanisms as a function of radial band bending in InN nanowires via universal mobility analysis, where effective carrier mobility is measured as a function of effective electric field in a nanowire field-effect transistor. Our results show that Coulomb scattering limits effective mobility at most effective fields, while surface roughness scattering only limits mobility under very high internal electric fields. High-energy {alpha} particle irradiation is used to vary the ionized donor concentration, and the observed decrease in mobility and increase in donor concentration are compared to Hall effect results of high-quality InN thin films. Our results show that for nanowires with relatively high doping and large diameters, controlling Coulomb scattering from ionized dopants should be given precedence over surface engineering when seeking to maximize nanowire mobility.

36 MATERIALS SCIENCE↗

SU-E-T-120: Analytic Dose Verification for Patient-Specific Proton Pencil Beam Scanning Plans

Purpose: To independently verify the QA dose of proton pencil beam scanning (PBS) plans using an analytic dose calculation model. Methods: An independent proton dose calculation engine is created using the same commissioning measurements as those employed to build our commercially available treatment planning system (TPS). Each proton PBS plan is exported from the TPS in DICOM format and calculated by this independent dose engine in a standard 40 x 40 x 40 cm water tank. This three-dimensional dose grid is then compared with the QA dose calculated by the commercial TPS, using standard Gamma criterion. A total of 18 measured pristine Bragg peaks, ranging from 100 to 226 MeV, are used in the model. Intermediate proton energies are interpolated. Similarly, optical properties of the spots are measured in air over 15 cm upstream and downstream, and fitted to a second-order polynomial. Multiple Coulomb scattering in water is approximated analytically using Preston and Kohler formula for faster calculation. The effect of range shifters on spot size is modeled with generalized Highland formula. Note that the above formulation approximates multiple Coulomb scattering in water and we therefore chose not use the full Moliere/Hanson form. Results: Initial examination of 3 patient-specific prostate PBS plans shows that agreement exists between 3D dose distributions calculated by the TPS and the independent proton PBS dose calculation engine. Both calculated dose distributions are compared with actual measurements at three different depths per beam and good agreements are again observed. Conclusion: Results here showed that 3D dose distributions calculated by this independent proton PBS dose engine are in good agreement with both TPS calculations and actual measurements. This tool can potentially be used to reduce the amount of different measurement depths required for patient-specific proton PBS QA.

60 APPLIED LIFE SCIENCES↗

Control of focusing forces and emittances in plasma-based accelerators using near-hollow plasma channels

A near-hollow plasma channel, where the plasma density in the channel is much less than the plasma density in the walls, is proposed to provide independent control over the focusing and accelerating forces in a plasma accelerator. In this geometry the low density in the channel contributes to the focusing forces, while the accelerating fields are determined by the high density in the channel walls. The channel also provides guiding for intense laser pulses used for wakefield excitation. Both electron and positron beams can be accelerated in a nearly symmetric fashion. Near-hollow plasma channels can effectively mitigate emittance growth due to Coulomb scattering for high-energy physics applications.

43 PARTICLE ACCELERATORS↗

Development of activity pencil beam algorithm using measured distribution data of positron emitter nuclei generated by proton irradiation of targets containing {sup 12}C, {sup 16}O, and {sup 40}Ca nuclei in preparation of clinical application

Purpose: The purpose of this study is to develop a new calculation algorithm that is satisfactory in terms of the requirements for both accuracy and calculation time for a simulation of imaging of the proton-irradiated volume in a patient body in clinical proton therapy. Methods: The activity pencil beam algorithm (APB algorithm), which is a new technique to apply the pencil beam algorithm generally used for proton dose calculations in proton therapy to the calculation of activity distributions, was developed as a calculation algorithm of the activity distributions formed by positron emitter nuclei generated from target nuclear fragment reactions. In the APB algorithm, activity distributions are calculated using an activity pencil beam kernel. In addition, the activity pencil beam kernel is constructed using measured activity distributions in the depth direction and calculations in the lateral direction. {sup 12}C, {sup 16}O, and {sup 40}Ca nuclei were determined as the major target nuclei that constitute a human body that are of relevance for calculation of activity distributions. In this study, ''virtual positron emitter nuclei'' was defined as the integral yield of various positron emitter nuclei generated from each target nucleus by target nuclear fragment reactions with irradiated proton beam. Compounds, namely, polyethylene, water (including some gelatin) and calcium oxide, which contain plenty of the target nuclei, were irradiated using a proton beam. In addition, depth activity distributions of virtual positron emitter nuclei generated in each compound from target nuclear fragment reactions were measured using a beam ON-LINE PET system mounted a rotating gantry port (BOLPs-RGp). The measured activity distributions depend on depth or, in other words, energy. The irradiated proton beam energies were 138, 179, and 223 MeV, and measurement time was about 5 h until the measured activity reached the background level. Furthermore, the activity pencil beam data were made using the activity pencil beam kernel, which was composed of the measured depth data and the lateral data including multiple Coulomb scattering approximated by the Gaussian function, and were used for calculating activity distributions. Results: The data of measured depth activity distributions for every target nucleus by proton beam energy were obtained using BOLPs-RGp. The form of the depth activity distribution was verified, and the data were made in consideration of the time-dependent change of the form. Time dependence of an activity distribution form could be represented by two half-lives. Gaussian form of the lateral distribution of the activity pencil beam kernel was decided by the effect of multiple Coulomb scattering. Thus, the data of activity pencil beam involving time dependence could be obtained in this study. Conclusions: The simulation of imaging of the proton-irradiated volume in a patient body using target nuclear fragment reactions was feasible with the developed APB algorithm taking time dependence into account. With the use of the APB algorithm, it was suggested that a system of simulation of activity distributions that has levels of both accuracy and calculation time appropriate for clinical use can be constructed.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

A new method for imaging nuclear threats using cosmic ray muons

Muon tomography is a technique that uses cosmic ray muons to generate three-dimensional images of volumes using information contained in the Coulomb scattering of the muons. Advantages of this technique are the ability of cosmic rays to penetrate significant overburden and the absence of any additional dose delivered to subjects under study beyond the natural cosmic ray flux. Disadvantages include the relatively long exposure times and poor position resolution and complex algorithms needed for reconstruction. Furthermore, we demonstrate a new method for obtaining improved position resolution and statistical precision for objects with spherical symmetry.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Positron generation using laser-wakefield electron sources

Positron generation, using wakefield-accelerated electrons driven into a converter target, was investigated experimentally and through Monte Carlo simulations. Using experimentally measured initial electron distributions from a 60 fs laser system, modeling shows that a collimated wakefield electron beam of moderate energy (50–200 MeV) produces a large number of positrons (~10 7 ), which are emitted from the rear of a mm-scale, high-Z target with divergence angles between 50 and 150 mrad. The large perpendicular momentum of the positrons was found to be dominated by contributions from multiple small angle Coulomb scattering. Positrons were not observed above background noise for a range of targets where simulations indicate a 5–30× increase in the beam charge was necessary to exceed threshold detection. These results provide new understanding to the fundamental limitations of creating narrow-divergence, high-density positron beams from laser-wakefield platforms for use in future laboratory pair plasma experiments.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Disorder from the Bulk Ionic Liquid in Electric Double Layer Transistors

Ionic liquid gating has a number of advantages over solid-state gating, especially for flexible or transparent devices and for applications requiring high carrier densities. But, the large number of charged ions near the channel inevitably results in Coulomb scattering, which limits the carrier mobility in otherwise clean systems. We develop a model for this Coulomb scattering. We then validate our model experimentally using ionic liquid gating of graphene across varying thicknesses of hexagonal boron nitride, demonstrating that disorder in the bulk ionic liquid often dominates the scattering.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Maximum-a-Posteriori Cosmic Ray Muon Trajectory Estimation with Energy Loss for Muon Tomography Applications

Recent cosmic ray muon tomography applications use detectors that measure position and direction of the individual muons before and after traversing the imaged object. However, muon reconstruction techniques are limited in resolution due to low muon flux and the effects of a single Coulomb scattering assumption. In the present work, the use of a Bayesian framework and a Gaussian approximation of multiple Coulomb scattering (MCS) is explored for maximum-a-posteriori estimation of the most likely path of a cosmic ray muon traversing a uniform and non uniform medium and undergoing MCS. Results were generated using a validated Geant4 workspace. The algorithm is expected to be able to predict muon tracks with improved accuracy and to increase the useful muon flux by 30% over a traditional point-of-closest-approach (PoCA) method. The effect of energy loss due to ionization is investigated, and an energy loss relation is derived and validated.

Chatzidakis, Stylianos↗

Measurement of the daytime photoelectron energy distribution from AE-E with improved energy resolution

A substantial improvement in energy resolution for photoelectron energy spectra in the 150-320 km altitude range is reported. The spectra were obtained with the AE-E satellite. The improvement is based on a data analysis technique which makes use of spectra obtained from the spinning spacecraft when the potential of the sensor varies slightly with respect to the ionospheric plasma as a consequence of the v x B induced voltage in the spacecraft body. The results permit determination of the line shape and area of the O and N2 304A solar radiation-produced photoelectron lines as a function of altitude. The photoelectron lines are found to be essentially unbroadened by coulomb scattering below 200 km, but substantial broadening occurs by 250 km. At 300 km, the characteristic line shape due to coulomb scattering with a degradation to low energy and a sharp high energy side can be observed readily.

Lee, J. S.↗

Non-thermal gamma-ray emission from delayed pair breakdown in a magnetized and photon-rich outflow

We consider delayed, volumetric heating in a magnetized outflow that has broken out of a confining medium and expanded to a high Lorentz factor (Γ ∼ 10{sup 2}-10{sup 3}) and low optical depth to scattering (τ {sub T} ∼ 10{sup –3}-10{sup –2}). The energy flux at breakout is dominated by the magnetic field, with a modest contribution from quasi-thermal gamma rays whose spectrum was calculated in Paper I. We focus on the case of extreme baryon depletion in the magnetized material, but allow for a separate baryonic component that is entrained from a confining medium. Dissipation is driven by relativistic motion between these two components, which develops once the photon compactness drops below 4 × 10{sup 3}(Y{sub e} /0.5){sup –1}. We first calculate the acceleration of the magnetized component following breakout, showing that embedded MHD turbulence provides significant inertia, the neglect of which leads to unrealistically high estimates of flow Lorentz factor. After reheating begins, the pair and photon distributions are evolved self-consistently using a one-zone kinetic code that incorporates an exact treatment of Compton scattering, pair production and annihilation, and Coulomb scattering. Heating leads to a surge in pair creation, and the scattering depth saturates at τ {sub T} ∼ 1-4. The plasma maintains a very low ratio of particle to magnetic pressure, and can support strong anisotropy in the charged particle distribution, with cooling dominated by Compton scattering. High-energy power-law spectra with photon indices in the range observed in gamma-ray bursts (GRBs; –3 < β < –3/2) are obtained by varying the ratio of heat input to the seed energy in quasi-thermal photons. We contrast our results with those for continuous heating across an expanding photosphere, and show that the latter model produces soft-to-hard evolution that is inconsistent with observations of GRBs.

79 ASTRONOMY AND ASTROPHYSICS↗

Heavy quark diffusion in strong magnetic fields at weak coupling and implications for elliptic flow

In this paper, we compute the momentum diffusion coefficients of heavy quarks, κ ∥ and κ ⊥ , in a strong magnetic field B along the directions parallel and perpendicular to B, respectively, at the leading order in QCD coupling constant α s . We consider a regime relevant for the relativistic heavy ion collisions, α s eB << T 2 << eB, so that thermal excitations of light quarks are restricted to the lowest Landau level (LLL) states. In the vanishing light-quark mass limit, we find κ LO ⊥ ∝ α 2 s TeB in the leading order that arises from screened Coulomb scatterings with (1+1)-dimensional LLL quarks, while κ ∥ gets no contribution from the scatterings with LLL quarks due to kinematic restrictions. We show that the first nonzero leading order contributions to κ LO ∥ come from the two separate effects: 1) the screened Coulomb scatterings with thermal gluons, and 2) a finite light-quark mass m q . The former leads to κ LO,gluon ∥ ∝ α 2 s T 3 and the latter to κ LO,massive ∥ ∝ α s (α s eB) 1/2 m 2 q . Based on our results, we propose a new scenario for the large value of heavy-quark elliptic flow observed in RHIC and LHC. Namely, when κ ⊥ >> κ ∥ , an anisotropy in drag forces gives rise to a sizable amount of the heavy-quark elliptic flow even if heavy quarks do not fully belong to an ellipsoidally expanding background fluid.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗