Search NASA⌕ Search

SEARCH · Search NASA

Results for “COUNTER”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 55 records · Page 3

Intermediate term frequency measurements with the HP computing counter in the USNO clock time system

High precision frequency measurements with various integration times can be made with conventional counters by using variable gate times. The Hewlett-Packard (HP) computing counter allows such measurements over a wide range of frequencies and measurement times. This instrument can also convert period measurements into frequency by means of its arithmetic capabilities: The program library contains programs to facilitate frequency stability measurements in the most direct and convenient way. This method was used as the basis for all time scale computations, until requirements for highest resolution justified the development of an automatic data acquisition system. The phase measurements are now being made with the HP computing counter (with time interval plug-in unit) under program control from the HP System Programmer.

Winkler, G. M. R.↗

Large neutron counters for supermonitors

Large neutron counters designed for the neutron supermonitor with an area of about 20 sq m are reported. Statistical accuracy of the counters is 0.1% per 2 hours. Dimensions: length--2 m; diameter--150 mm; pressure--200 mm Hg. The counters are filled with BF3 gas containing over 80% of B-10.

Blokh, Y. L.↗

The effect of thermal neutron field slagging caused by cylindrical BF3 counters in diffusion media

Computations are carried out in transport approximation (first collision method) for the attenuation of the field of thermal neutrons formed in counters of the CHM-8 and CHMO-5 type. The deflection of the thermal neutron field is also obtained near the counters and in the air (shade effect) and in various decelerating media (water, paraffin, plexiglas) for which the calculations are carried out on the basis of diffusion theory. To verify the calculations, the distribution of the density of the thermal neutrons at various distances from the counter in the water is measured.

Gorshkov, G. V.↗

Measurement accuracy of flow velocity via a digital-frequency-counter laser velocimeter processor

The laser velocimeter (LV) technique has so far been successfully applied to many flow situations to obtain mean velocity and turbulence level measurements. The paper deals with a unique LV system employing a digital frequency counter for measurements of turbulence spectra within the objectives of achieving higher accuracies and a wider range of velocities than were possible by previous analog systems. Systematic analysis of the effects of LV system errors in the accuracy of the turbulence power spectral measurements is performed and shown to agree reasonably with the experimental LV spectra results. Sufficient understanding of the accuracy and limitations of the digital frequency counter LV spectral measurement system is obtained. Among the major system errors encountered in a typical digital frequency counter LV processor, the truncation error is regarded as the most serious source of error. The quantizing step size defined as the ratio of Doppler frequency to processor clock frequency is an important parameter in determining the dynamic range of a turbulence power spectrum.

Wang, J. C. F.↗

Recent developments in parallel-grid, gas-scintillation proportional counters

The problems of developing large-area, gas-scintillation proportional counters with high resolution are considered. It is found that simple large-area, parallel-grid proportional counters suffer from a variation in gain over the counter window. Some success has been achieved in overcoming this problem by focusing the charge cloud as it drifts into the multiplication region. Measurements are reported for various mixtures of argon and xenon as well as pure xenon.

Anderson, D. F.↗

The HEAO-B Monitor Proportional Counter Instrument

The Monitor Proportional Counter Instrument for the HEAO-B X-ray Telescope satellite is designed to observe celestial X-ray sources in the range of 1 to 20 keV with intensities exceeding .0002 Crab. It provides both spectral and temporal data, to complement the data from the other HEAO-B instruments, to compare with observations from previous flights, as well as to allow detailed study of time variant X-ray phenomena. The basic detector is a large area proportional counter system, consisting of two counters, high voltage power supplies and preamplifiers, mounted behind a collimator with a 2/3 degree square field of view. The signal processing, power distribution and control electronics are contained in a separate unit, which includes circuitry to perform pulse height analysis, background rejection, time interval measurement, redundancy switching and control, housekeeping and telemetry interfacing.

Gaillardetz, R.↗

A large-area gas scintillation proportional counter for X-ray astronomy

An improved large-area gas scintillation proportional counter has been built, suitable for use in X-ray astronomy. This counter employs electron focusing in a drift region to achieve uniform response. It is shown that a spectral resolution of 9.1% FWHM at 5.9 keV can be obtained over a useful area of 100 sq cm. It is demonstrated that signal rise-time discrimination can be used to reject non-X-ray background as efficiently as in ordinary proportional counters.

Anderson, D. F.↗

Variable-resolution counter

Variable-resolution counter circuit increases time interval that nbit binary counter can measure by using multivalue input clock. Circuit allows measurement of time intervals beyond capability of single n-bit counter while maintaining reasonable resolution.

Clemmons, J. I., Jr↗

A drift multiwire proportional counter for cosmic soft X-ray imaging

Multiwire proportional counters with 1 micrometer polypropylene windows, of dimensions 75 mm x 75 mm and 100 mm x 100 mm, have been built to map soft cosmic X-rays. The counters are constructed with a large drift region which makes it possible to use the center-of-gravity technique to improve the counter's efficiency and position resolution. Using 330 torr of propane as the gas fill and an anode plane composed of 20 micrometer diameter, gold-plated tungsten wire spaced 1mm apart, a position resolution of better than 280 micrometers (FWHM) in two orthogonal directions at an X-ray energy of 0.94 keV was achieved.

Reid, P. B.↗

The function and response of an improved stratospheric condensation nucleus counter

An improved condensation nucleus counter (CNC) for use in the stratosphere is described. The University of Minnesota CNC (UMCNC) has a sequential saturator and condenser and uses n-butyl alcohol as the working fluid. The use of a coaxial saturator flow, with aerosol in the center and filtered, alcohol-laden air around it, speeds the response of this instrument and improves its stability as pressure changes. The counting efficiency has been studied as a function of particle size and pressure. The UMCNC provides an accurate measure of submicron aerosol concentration as long as the number distribution is not dominated by sub-0.02 micron diameter aerosol. The response of the UMCNC is compared with that of other stratospheric condensation nucleus counters, and the results of a (near) comparison with a balloon-borne condensation nucleus counter are presented. The UMCNC has operated 14 times on a NASA U-2 aircraft at altitudes from 8 to 21.5 km.

Wilson, J. C.↗

Cerenkov counters for high energy nuclei: Some new developments

A method to determine with gas Cerenkov counters the Lorentz factor, gamma = E/mc, of cosmic ray nuclei with high accuracy over the range gamma approx. 20 to 100 is discussed. The measurement of the Cerenkov emission angle theta, by use of a suitable imaging system is considered. Imaging counters, the ring imaging Cerenkov counters (RICH), were developed for use on accelerators. The image of off-axis particles to determine the amount of image distortion as a function of the direction of the incoming nucleus is examined and an acceptance solid angle, relative to the optical axis, within which the nucleus produces an image with an acceptable level of distortion is defined. The properties of the image, which becomes elliptical, for off-axis particles are analyzed.

Swordy, S. P.↗

An imaging gas scintillation proportional counter for use in X-ray astronomy

An imaging gas scintillation proportional counter (GSPC) has been constructed for use in X-ray astronomy. The IGSPC consists of a gas scintillation proportional counter (GSPC) with a 1 micron polypropylene window coupled to a multiwire proportional counter (MWPC) via a calcium fluoride window. The MWPC, filled with a mixture of argon, methane, and tetrakis (dimethylamino) ethylene, detects the UV photons emitted by the xenon gas in the GSPC. The measured energy resolution is 17.0 percent (fwhm) and 8.0 percent (fwhm) at 1.5 keV and 5.9 keV, respectively. The measured position resolution is 1.9 mm (fwhm) and 0.9 mm (fwhm) at 1.5 and 5.9 keV, respectively. Possible astrophysical observations which can be performed with an IGSPC at the focal plane of a grazing incidence telescope are also discussed.

Hailey, C. J.↗

A large area imaging gas scintillation proportional counter for use in X-ray astronomy

A large area (200 sq cm), broad bandwidth (0.1-70 keV), imaging gas scintillation proportional counter (IGSPC) has been constructed for use in X-ray astronomy. The IGSPC consists of a high pressure xenon gas scintillation proportional counter (GSPC) coupled to a multi-wire proportional counter (MWPC) via a calcium fluoride window. THe MWPC, filled with a mixture of argon, methane, and tetrakis (dimethylamino) ethylene, detects the UV photons emitted by the xenon gas in the GSPC. The detector has a measured energy resolution of 8.0 percent (FWHM) and 4.3 percent (FWHM) at 5.9 keV and 22.1 keV, respectively. The predicted spatial resolution of the detector is less than 1 mm (FWHM) between 3-22 keV and 37-60 keV. A method to determine the three-dimensional location of detected X-rays is described. In addition, a combination of discrimination schemes designed to reduce the non-X-ray background in the IGSPC by more than two orders of magnitude is discussed.

Ku, W. H.-M.↗

Laser velocimeter measurements of the flow fields around single- and counter-rotation propeller models

A two-component LV system was used to make detailed measurements of the flow field around both a single-rotation and a counter-rotation propeller/nacelle. The conditions measured for the single-rotation tractor configuration include two different blade angles and two propeller advance ratios, and for the counter-rotation propeller configuration include both pusher and tractor mounts. The measurements show the increasing slipstream velocities and contraction with increasing blade angle and with decreasing advance ratios. Data for the counter-rotation system show that the aft propeller turns the flow in the opposite direction from the front propeller. Additionally, the LV system was used as a diagnostic tool to provide data to explain the large side force measured on the propeller/nacelle at angle-of-attack.

Dunham, D. M.↗

Some design philosophy for reducing the community noise of advanced counter-rotation propellers

Advanced counter-rotation propellers have been indicated as possibly generating an unacceptable amount of noise for the people living near an airport. This report has explored ways to reduce this noise level, which is treated as being caused by the interaction of the upstream propeller wakes and vortices with the downstream propeller. The noise reduction techniques fall into two categories: (1) reducing the strength of the wakes and vortices, and (2) reducing the response of the downstream blades to them. The noise from the wake interaction was indicated as being reduced by increased propeller spacing and decreased blade drag coefficient. The vortex-interaction noise could be eliminated by having the vortex pass over the tips of the downstream blade, and it could be reduced by increased spacing or decreased initial circulation. The downstream blade response could be lessened by increasing the reduced frequency parameter omega or by phasing of the response from different sections to have a mutual cancellation effect. Uneven blade to blade spacing for the downstream blading was indicated as having a possible effect on the annoyance of counter-rotation propeller noise. Although there are undoubtedly additional methods of noise reduction not covered in this report, the inclusion of the design methods discussed would potentially result in a counter-rotation propeller that is acceptably quiet.

Dittmar, J. H.↗

A numerical method for the design and analysis of counter-rotating propellers

A numerical method has been developed using the techniques of Lock and Theodorsen as described by Davidson to design and analyze counter-rotating propellers. The design method develops the optimum propeller geometry by calculating the planform and twist distribution for each propeller disk through the use of specific inputs of engine shaft horsepower, diameter, and disk spacing. The analysis method calculates the performance of a given counter-rotating propeller system at any flight condition. Using the NACA four-digit airfoil family, the performance of a counter-rotating propeller design for a given flight condition was investigated in the design and analysis mode.

Playle, S. C.↗

Effect of angular inflow on the vibratory response of a counter-rotating propeller

This report presents the results of a propeller vibratory stress survey on the Fairey Gannet aircraft aimed at giving an assessment of the difference in vibratory response between single and counter-rotating propeller operation in angular inflow. The survey showed that counter-rotating operation of the propeller had the effect of increasing the IP response of the rear propeller by approximately 25 percent over comparable single-rotation operation while counter-rotating operation did not significantly influence the IP response of the front propeller.

Turnberg, J. E.↗

Average-passage simulation of counter-rotating propfan propulsion systems as applied to cruise missiles

Counter-rotating propfan (CRP) propulsion technologies are currently being evaluated as cruise missile propulsion systems. The aerodynamic integration concerns associated with this application are being addressed through the computational modeling of the missile body-propfan flowfield interactions. The work described in this paper consists of a detailed analysis of the aerodynamic interactions between the control surfaces and the propfan blades through the solution of the average-passage equation system. Two baseline configurations were studied, the control fins mounted forward of the counter-rotating propeller and the control fins mounted aft of the counter-rotating propeller. In both cases, control fin-propfan separation distance and control fin deflection angle were varied.

Mulac, Richard A.↗