Search NASA⌕ Search

SEARCH · Search NASA

Results for “CPL”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 55 records · Page 3

Capillary pumped loop GAS and Hitchhiker flight experiments

Flight experiments of a capillary pumped loop (CPL) aboard the Space Shuttle on both the Get Away Special (GAS) and Hitchhiker-G (H/H-G) carriers are described. These tests have shown that a two-phase heat transfer loop utilizing a wicking material as the system pumping mechanism can operate successfully in a zero-g environment. The CPL operating modes demonstrated were start-up, heat load sharing/natural priming, liquid inventory and temperature control via the reservoir, dryout recovery, and isolation of a single pump deprime. Also investigated were high and low power limits, and inlet subcooling requirements. In these CPL flight experiments, successful system operation was demonstrated at input power levels up to 560 watts and inlet subcooling below 2 C.

Ku, J.↗

Design of an advanced two-phase capillary cold plate

The functional principles and implementation of capillary pumped loop (CPL) two phase heat transport system for various elements of the Space Station program are described. Circulation of the working fluid by the surface-tension forces in a fine-pore capillary wick is the core principle of CPL systems. The liquid, usually NH3 at the moment, is changed into a vapor by heat absorption at one end of the loop, and the vapor is carrried back along the wick by the surface tension within the wick. NASA specifications and the results of mechanical and thermal tests for prototype cold plate and the capillary pump designs are outlined. The CPL is targeted for installation on free-flying platforms, attached payloads, and power subsystem thermal control systems.

Chalmers, D. R.↗

Exploratory study of temperature oscillations related to transient operation of a Capillary Pumped Loop heat pipe

An analytical study has been conducted for better understanding of a peculiar transient behavior which was displayed in testing of a Capillary Pumped Loop (CPL) heat pipe system. During several test runs of this CPL system varying degrees of surface temperature oscillations occurred in the inlet line of the evaporators. Although several theories have been forwarded to explain this observed phenomenon, a satisfactory understanding of causes of these oscillations is still missing. The present investigation derives the conditions which lead to such oscillatory temperature behavior in evaporator inlet section of the mentioned CPL system. Stability characteristics of these temperature oscillations were investigated.

Kiper, A. M.↗

Capillary Pumped Loop Modeler

Capillary Pumped Loop (CPL) Modeler computer program is amalgamation of software that mathematically models performance of CPL system and its environment. Two-phase heat-transport device capable of transferring heat loads efficiently over large distance with little temperature differential. Utilizes surface-tension forces established in fine-pore capillary wick to circulate working fluid, requiring no external pumpling power. Predicts steady-state or quasi-steady behavior of CPL embedded in spacecraft or other thermal environment. Also predicts location of liquid/vapor interface in each condenser. Written in VAX/VMS FORTAN 77.

Ku, Jentung↗

Development and integration of the capillary pumped loop GAS and Hitchhiker flight experiments

The Capillary Pumped Loop (CPL) is a thermal control system with high density heat acquisition and transport capability. A small spaceflight version of the CPL was built and flown as a GAS experiment on STS 51-D in April 1985 and STS 51-G in June 1985, and as a Hitchhiker-G experiment on STS 61-C in January 1986. The purpose of the experiments was to demonstrate the capability of a capillary pumped system under microgravity conditions for use in the thermal control of large scientific instruments, advanced orbiting spacecraft, and space station components. The development, integration, and test activities of the CPL are described.

Butler, D.↗

A prototype heat pipe heat exchanger for the capillary pumped loop flight experiment

A Capillary Pumped Two-Phase Heat Transport Loop (CAPL) Flight Experiment, currently planned for 1993, will provide microgravity verification of the prototype capillary pumped loop (CPL) thermal control system for EOS. CAPL employs a heat pipe heat exchanger (HPHX) to couple the condenser section of the CPL to the radiator assembly. A prototype HPHX consisting of a heat exchanger (HX), a header heat pipe (HHP), a spreader heat pipe (SHP), and a flow regulator has been designed and tested. The HX transmits heat from the CPL condenser to the HHP, while the HHP and SHP transport heat to the radiator assembly. The flow regulator controls flow distribution among multiple parallel HPHX's. Test results indicated that the prototype HPHX could transport up to 800 watts with an overall heat transfer coefficient of more than 6000 watts/sq m-deg C. Flow regulation among parallel HPHX's was also demonstrated.

Ku, Jentung↗

Two-phase/two-phase heat exchanger simulation analysis

The capillary pumped loop (CPL) system is one of the most desirable devices to dissipate heat energy in the radiation environment of the Space Station providing a relatively easy control of the temperature. A condenser, a component of the CPL system, is linked with a buffer evaporator in the form of an annulus section of a double tube heat exchanger arrangement: the concentric core of the double tube is the condenser; the annulus section is used as a buffer between the conditioned space and the radiation surrounding but works as an evaporator. A CPL system with this type of condenser is modeled to simulate its function numerically. Preliminary results for temperature variations of the system are shown and more investigations are suggested for further improvement.

Kim, Rhyn H.↗

Experimental and theoretical studies of capillary-pumped loop heat pipes

An experimental investigation of capillary-pumped loop (CPL) head pipes with single and multiple evaporators designed to develop and validate a computer model to predict the performance of CPL heat pipes over a wide range of conditions is discussed. The results of a literature search and review and a numerical study to determine the effects of geometric design parameters on the CPL heat pipe pressure drop and heat transfer characteristics are described. Vapor groove geometry and the use of circular versus rectangular evaporators were studied.

Obot, N. T.↗

Flight Test Results for the HST Orbital Systems Test (HOST) Capillary Pump Loop Cooling System

The Near Infrared Camera and Multi Object Spectrometer (NICMOS) was installed in the Hubble Space Telescope (MST) in February 1997. Shortly thereafter, the instrument experienced a thermal short in its solid nitrogen dewar system which will significantly shorten the instrument's useful life. A reverse Brayton cycle mechanical refrigerator will be installed during the Third Servicing Mission (SM3) to provide cooling for the instrument, and thereby extend its operations. A Capillary Pump Loop (CPL) and radiator system was designed, built and tested to remove up to 500 watts of heat from the mechanical cryocooler and its associated electronics. The HST Orbital Systems Test (HOST) platform was flown on the Space Shuttle Discovery (STS-95) as a flight demonstration of the cryocooler system, CPL control electronics, and the CPL/Radiator. This paper will present the flight test results and thermal performance of the CPL system in detail.

Buchko, M.↗

The Algorithm Theoretical Basis Document for the GLAS Atmospheric Data Products

The purpose of this document is to present a detailed description of the algorithm theoretical basis for each of the GLAS data products. This will be the final version of this document. The algorithms were initially designed and written based on the authors prior experience with high altitude lidar data on systems such as the Cloud and Aerosol Lidar System (CALS) and the Cloud Physics Lidar (CPL), both of which fly on the NASA ER-2 high altitude aircraft. These lidar systems have been employed in many field experiments around the world and algorithms have been developed to analyze these data for a number of atmospheric parameters. CALS data have been analyzed for cloud top height, thin cloud optical depth, cirrus cloud emittance (Spinhirne and Hart, 1990) and boundary layer depth (Palm and Spinhirne, 1987, 1998). The successor to CALS, the CPL, has also been extensively deployed in field missions since 2000 including the validation of GLAS and CALIPSO. The CALS and early CPL data sets also served as the basis for the construction of simulated GLAS data sets which were then used to develop and test the GLAS analysis algorithms.

Palm, Stephen P.↗

SLS Payload Transportation Beyond LEO

NASA has successfully completed the Critical Design Review (CDR) of the heavy lift Space Launch System (SLS) and is working towards the first flight of the vehicle in 2018. SLS will begin flying crewed missions with an Orion capsule to the lunar vicinity every year after the first 2 flights starting in the early 2020's. As early as 2021, in addition to delivering an Orion capsule to a cislunar destination, SLS will also deliver ancillary payload, termed "Co-manifested Payload (CPL)", with a mass of at least 5.5 mT and volume up to 280 m3 simultaneously to that same destination. Later SLS flights have a goal of delivering as much as 10 mT of CPL to cislunar destinations. In addition to cislunar destinations, SLS flights may deliver non-crewed, science-driven missions with Primary Payload (PPL) to more distant destinations. SLS PPL missions will utilize a unique payload fairing offering payload volume (ranging from 320 m3 to 540 m3) that greatly exceeds the largest existing Expendable Launch Vehicle (ELV) fairing available. The Characteristic Energy (C3) offered by the SLS system will generate opportunities to deliver up to 40 mT to cislunar space, and deliver double PPL mass or de-crease flight time by half for some outer planet destinations when compared to existing capabilities. For example, SLS flights may deliver the Europa Clipper to a Jovian destination in under 3 years by the mid 2020's, compared to the 7+ years cruise time required for current launch capabilities. This presentation will describe ground and flight accommodations, interfaces, resources, and performance planned to be made available to potential CPL and PPL science users of SLS. In addition, this presentation should promote a dialogue between vehicle developers, potential payload users, and funding sources in order to most efficiently evolve required SLS capabilities to meet diverse payload needs as they are identified over the next 35 years and beyond.

Creech, S. D.↗

Simulations of Infrared Radiances Over a Deep Convective Cloud System Observed During TC4- Potential for Enhancing Nocturnal Ice Cloud Retrievals

Retrievals of ice cloud properties using infrared measurements at 3.7, 6.7, 7.3, 8.5, 10.8, and 12.0 microns can provide consistent results regardless of solar illumination, but are limited to cloud optical thicknesses tau < approx.6. This paper investigates the variations in radiances at these wavelengths over a deep convective cloud system for their potential to extend retrievals of tau and ice particle size D(sub e) to optically thick clouds. Measurements from the Moderate Resolution Imaging Spectroradiometer Airborne Simulator--ASTER, the Scanning High-resolution Interferometer Sounder, the Cloud Physics Lidar (CPL), and the Cloud Radar System (CRS) aboard the NASA ER-2 aircraft during the NASA TC4 (Tropical Composition, Cloud and Climate Coupling) experiment flight during 5 August 2007, are used to examine the retrieval capabilities of infrared radiances over optically thick ice clouds. Simulations based on coincident in-situ measurements and combined cloud tau from CRS and CPL measurements are comparable to the observations. They reveal that brightness temperatures at these bands and their differences (BTD) are sensitive to tau up to approx.20 and that for ice clouds having tau > 20, the 3.7 - 10.8 microns and 3.7 - 6.7 microns BTDs are the most sensitive to D(sub e). Satellite imagery appears consistent with these results. Keywords: clouds; optical depth; particle size; satellite; TC4; multispectral thermal infrared

CRS and CPL↗

Stability Considerations for Virtual Capacitor Control in Constant Power DC Loads

In a DC grid, constant power loads (CPLs) necessitate a large bus capacitor to prevent negative impedance instability. Some of the capacitance can be realized virtually through CPL control to reduce the bus capacitor size. Here, this paper analytically studies system stability with virtual capacitor control. We demonstrate that the effectiveness of virtual capacitor control is highly sensitive to the implementation of the derivative action required to emulate the capacitor. For the first time, we theoretically demonstrate that a virtual capacitor can stabilize the system without any physical bus capacitor, provided that a set of analytically derived conditions are met. However, this stabilization is not achievable in practice due to the influence of non-idealities. In an example system requiring a $14$ mF capacitor to stably support the CPL, we show that stability can be achieved through virtual capacitor control, using only a 2 mF physical capacitor to account for the switching ripple non-idealities. Hardware-in-the-loop tests verify the analysis.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Circularly polarized inertial wave vectors in rotating fluids

The Navier-Stokes equations for a rotating fluid are harmonically analyzed for planar motion in an infinite half-space. All solutions are shown to be a sum of two inertial wave vectors, one circularly polarized to the left (CPL) and the other circularly polarized to the right (CPR). These basic solutions are therefore presented in the same nomenclature and form as that found useful by experimentalists in analyzing flow data (called 'rotary spectra'). The CPL wave acts counter to the Coriolis force and consequently has a slower phase speed and larger damping than the CPR wave. At resonance (forcing frequency = Coriolis frequency) the CPR wave has an infinite phase speed and no damping and is the important component leading to the singular nature of the solutions for certain boundary conditions. All possible resonant singularities are explicitly shown. The unsteady development of these unbounded (limited space structure), cyclic (no time origin or structure) flows is presented to show that with time structure the resonant singularities evolve in a self-similar manner.

Cogley, A. C.↗

Design, development and test of a capillary pump loop heat pipe

The development of a capillary pump loop (CPL) heat pipe, including computer modeling and breadboard testing, is presented. The computer model is a SINDA-type thermal analyzer, combined with a pressure analyzer, which predicts the transients of the CPL heat pipe during operation. The breadboard is an aluminum/ammonia transport system which contains multiple parallel evaporator and condenser zones within a single loop. Test results have demonstrated the practicality and reliability of such a design, including heat load sharing among evaporators, liquid inventory/temperature control feature, and priming under load. Transport capability for this system is 65 KW-M with individual evaporator pumps managing up to 1.7 KW at a heat flux of 15 W/sq cm. The prediction of the computer model for heat transport capabilities is in good agreement with experimental results.

Kroliczek, E. J.↗

Transient analysis of a capillary pumped loop heat pipe

A bench-top Capillary Pumped Loop (CPL) test system has been developed and tested to investigate the transient mode operation of this system by applying a step power input to the evaporators. Tests were conducted at several power input and evaporator inlet subcooling combinations. In addition, a lumped-heat-capacity model of the CPL test system has been presented which is used for predicting qualitatively the transient operation characteristics. Good agreement has been obtained between the predicted and the measured temperature variations. A simple evaporator inlet subcooler model has also been developed to study effects of inlet subcooling on the steady-state evaporator wall temperature. Results were compared with the test data collected.

Kiper, A. M.↗

Test results of prototype two-phase reservoirs for the CAPL flight experiment

The Capillary Pumped Loop Flight Experiment (CAPL) was designed to test components being considered for inclusion in the Earth Observing System (EOS) instrument thermal control system. The thermal operating conditions of a capillary pumped loop (CPL) heat transport system are controlled by a two-phase reservoir. Three prototype two-phase reservoirs designed for use in microgravity applications were built to CAPL specifications and performance tested at NASA Goddard Space Flight Center using anhydrous ammonia as the working fluid. Test results for liquid expulsion rates and CPL operational control are presented for each reservoir.

Buchko, Matthew T.↗

Two-phase/two-phase heat exchanger analysis

A capillary pumped loop (CPL) system with a condenser linked to a double two-phase heat exchanger is analyzed numerically to simulate the performance of the system from different starting conditions to a steady state condition based on a simplified model. Results of the investigation are compared with those of similar apparatus available in the Space Station applications of the CPL system with a double two-phase heat exchanger.

Kim, Rhyn H.↗