Search NASA⌕ Search

SEARCH · Search NASA

Results for “CRM”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 55 records · Page 3

An Evaluation of Actinide Reactivity with CO 2 , O 2 , and O 2 /He Gases using Inductively Coupled Plasma Tandem Mass Spectrometry: Application to Simultaneous Measurement of 241 Am/ 241 Pu Ratios in Unseparated Complex Matrices

Accurate actinide measurements are critical within the field of nuclear science. Traditional methods for actinide quantification require time-consuming sample processing prior to analysis. There is a need for rapid analytical techniques that still maintain a high degree of accuracy. In this work, actinide reactivity was assessed for multiple oxygen-containing reaction gases using quadrupole inductively coupled plasma tandem mass spectrometry (Q-ICP-MS/MS) to evaluate actinide analysis in complex sample matrices without analyte-matrix separation. A novel method was developed to measure 241 Am/ 241 Pu in complex sample matrices using O 2 /He reaction gas with no matrix removal or analyte pre-concentration. This inline method reduces matrix-derived polyatomic interferences that complicate traditional ICP-MS analyses by mass-shifting to 241 Am 16 O + and 241 Pu 16 O 2 + , allowing Am and Pu to be mass separated for simultaneous analysis. While mass shifting is efficient, a small portion of Am + (<1.3%) and Pu + (<1.4%) react to from AmO 2 + and PuO + , respectively. Therefore, a mass balance approach was used, in combination with reactivity determined from 242 Pu and 243 Am standard solutions, to correct for residual 241 PuO + and 241 AmO 2 + . The method was validated by measuring 241 Am/ 241 Pu in Pu isotope standards CRM-136 and CRM-137 (separated in March/April 1970 and February 2022, respectively) in both neat solutions and complex matrices containing diluted soil (NIST SRM 2711a, >1000 µg·g -1 ). Method detection limits of 15.9 and 9.6 fg·g -1 were determined for 241 Am and 241 Pu, respectively, and 241 Am/ 241 Pu ratios were measured with accuracies within <3.5%. In conclusion, this work presents the first direct analysis of 241 Am/ 241 Pu in unseparated complex matrices, advancing capabilities for rapid actinide measurements.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Load‐Balancing Intense Physics Calculations to Embed Regionalized High‐Resolution Cloud Resolving Models in the E3SM and CESM Climate Models

Abstract We design a new strategy to load‐balance high‐intensity sub‐grid atmospheric physics calculations restricted to a small fraction of a global climate simulation's domain. We show why the current parallel load balancing infrastructure of Community Earth System Model (CESM) and Energy Exascale Earth Model (E3SM) cannot efficiently handle this scenario at large core counts. As an example, we study an unusual configuration of the E3SM Multiscale Modeling Framework (MMF) that embeds a binary mixture of two separate cloud‐resolving model grid structures that is attractive for low cloud feedback studies. Less than a third of the planet uses high‐resolution (MMF‐HR; sub‐km horizontal grid spacing) relative to standard low‐resolution (MMF‐LR) cloud superparameterization elsewhere. To enable MMF runs with Multi‐Domain cloud resolving models (CRMs), our load balancing theory predicts the most efficient computational scale as a function of the high‐intensity work's relative overhead and its fractional coverage. The scheme successfully maximizes model throughput and minimizes model cost relative to precursor infrastructure, effectively by devoting the vast majority of the processor pool to operate on the few high‐intensity (and rate‐limiting) high‐resolution (HR) grid columns. Two examples prove the concept, showing that minor artifacts can be introduced near the HR/low‐resolution CRM grid transition boundary on idealized aquaplanets, but are minimal in operationally relevant real‐geography settings. As intended, within the high (low) resolution area, our Multi‐Domain CRM simulations exhibit cloud fraction and shortwave reflection convergent to standard baseline tests that use globally homogenous MMF‐LR and MMF‐HR. We suggest this approach can open up a range of creative multi‐resolution climate experiments without requiring unduly large allocations of computational resources.

54 ENVIRONMENTAL SCIENCES↗

Stable Machine‐Learning Parameterization of Subgrid Processes in a Comprehensive Atmospheric Model Learned From Embedded Convection‐Permitting Simulations

Modern climate projections often suffer from inadequate spatial and temporal resolution due to computational limitations, resulting in inaccurate representations of sub-grid processes. A promising technique to address this is the multiscale modeling framework (MMF), which embeds a kilometer-resolution cloud-resolving model (CRM) within each atmospheric column of a host climate model to replace traditional convection and cloud parameterizations. Machine learning offers a unique opportunity to make MMF more accessible by emulating the embedded CRM and reducing its substantial computational cost. Although many studies have demonstrated proof-of-concept success of achieving stable hybrid simulations, it remains a challenge to achieve near operational-level success with real geography and comprehensive variable emulation that includes, for example, explicit cloud condensate coupling. In this study, we present a stable hybrid model capable of integrating for at least 5 years with near operational-level complexity, including coarse-grid geography, seasonality, explicit cloud condensate and wind predictions, and land coupling. Our model demonstrates skillful online performance, achieving a 5-year zonal mean tropospheric temperature bias within 2 K, water vapor bias within 1 g/kg, and a precipitation root mean square error of 0.96 mm/day. Key factors contributing to our online performance include an expressive U-Net architecture and physical thermodynamic constraints for microphysics. With microphysical constraints mitigating unrealistic cloud formation, our work is the first to demonstrate realistic multi-year cloud condensate climatology under the MMF framework. Despite these advances, online diagnostics reveal persistent biases in certain regions, highlighting the need for innovative strategies to further optimize online performance.

Hu, Zeyuan [NVIDIA Corporation, Santa Clara, CA (U↗

Momentum informed muon scattering tomography for monitoring spent nuclear fuels in dry storage cask

Development of an effective monitoring method for spent nuclear fuel (SNF) in a dry storage cask (DSC) is important to meet the increasing demand for dry storage investigations. The DSC investigation should provide information about the quantity of stored SNF, and quality assurance of materials should be possible without opening the cask. However, traditional nondestructive examination (NDE) methods such as x-rays are difficult to deploy for DSC investigation because a typical DSC is intentionally designed to shield against radiation. To address this challenge, cosmic ray muons (CRMs) are used as an alternative NDE radiation probe because they can easily penetrate an entire DSC system; however, a wide application of muons is often hindered due to the naturally low CRM flux (~10 4 muons/m 2 /min). This paper introduces a newly proposed imaging algorithm, momentum-informed muon scattering tomography (MMST) , and presents how a limitation of the current muon scattering tomography technique has been addressed by measuring muon momentum. To demonstrate its functionality, a commercial DSC with 24 pressurized light water reactor fuel assemblies (FAs) and the MMST system were designed in GEANT4. Three noticeable improvements were observed for MMST system as a DSC investigation tool: (1) a signal stabilization, (2) an enhanced capability to differentiate various materials, and (3) statistically increased precision to identify and locate missing FAs. The results show that MMST improves the investigation accuracy from 79 to 98% when one FA is missing and 51% to 88% when one-half FA is missing. The advancement of the NDE technique using CRM for DSC verification is expected to resolve long-standing problems in increasing demand for DSC inspections and nuclear security.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Direct analysis of cotton swipes for plutonium isotope determination by microextraction-ICP-MS

This study demonstrates a method for determining the isotopic composition of low-level (sub-pg) plutonium (Pu) directly from a cotton swipe. Environmental sample (ES) swipes are routinely employed as a tool for monitoring activities in nuclear facilities. Traditional ES swipe analysis, as employed in nuclear safeguards, utilizes laborious ashing, digestion, and chemical separation procedures prior to mass spectrometric (MS) analysis. Here, an innovative sample introduction technique employing a microextraction probe to extract Pu directly from the swipe surface is described. The microextraction probe lowers onto the swipe surface, seals on a small area (8 mm 2 ), and delivers solvent (2% HNO 3 ) to extract actinide material that may be present. The extracted analyte is subsequently directed into a sector field inductively coupled plasma (ICP)-MS for isotope ratio determination. This microextraction-ICP-MS method successfully determined the isotopic composition ( 240 Pu/ 239 Pu and 242 Pu/ 239 Pu) of three Pu certified reference materials (CRM 136, 137, and 138) that were deposited (1 pg) onto ES swipes. The percent relative difference from the certified value, uncorrected for instrumental fractionation, was <2% for the 240 Pu/ 239 Pu ratio on all three CRMs and <10% for the 242 Pu/ 239 Pu ratio on CRM 136 and 138. Here, the percent relative standard deviation, an estimate of the sample-to-sample isotopic precision, was <4% for the 240 Pu/ 239 Pu and <15% for the 242 Pu/ 239 Pu. Method limits of detection were determined, based on measurements of an enriched 244 Pu material, to be ~7 fg. Additionally, a mixed uranium (U) and Pu deposition was made to determine the method's ability to simultaneously extract U and Pu and determine the isotopic composition of both analytes.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Spatiotemporal measurements of striations in a glow discharge’s positive column using laser-collisional induced fluorescence

Here we have observed the behavior of striations caused by ionization waves propagating in low-pressure helium DC discharges using the non-invasive laser-collision induced fluorescence (LCIF) diagnostic. To achieve this, we developed an analytic fit of collisional radiative model (CRM) predictions to interpret the LCIF data and recover quantitative two-dimensional spatial maps of the electron density, n e , and the ratios of LCIF emission states that can be correlated with T e with the use of accurate distribution functions at localized positions within striated helium discharges at 500 mTorr, 750 mTorr, and 1 Torr. To our knowledge, these are the first spatiotemporal, laser-based, experimental measurements of n e in DC striations. The n e and 447:588 ratio distributions align closely with striation theory. Constriction of the positive column appears to occur with decreased gas pressure, as shown by the radial n e distribution. We identify a transition from a slow ionization wave to a fast ionization wave between 750 mTorr and 1 Torr. These experiments validate our analytic fit of n e , allowing the implementation of an LCIF diagnostic in helium without the need to develop a CRM.

42 ENGINEERING↗

Observation of D 2 molecule line emission after massive D 2 injection into runaway electron plateaus in DIII-D

Molecular deuterium line emission is observed in both the visible and ultraviolet (UV) wavelength ranges after massive (> 100 Torr-L) injection of D 2 gas into post-disruption runaway electron (RE) dominated plasmas in the DIII-D tokamak. D 2 UV line emission is found to be the dominant source of radiated power, surpassing D Lyα. Interpretive modeling with a collisional-radiative model (CRM) indicates that D 2 radiation surpasses D radiation because Lyα is strongly trapped, while D 2 UV lines are mostly untrapped. The CRM also indicates that the D 2 line emission is completely dominated by RE impact (rather than thermal electron impact), so the D 2 line emission can serve as a good diagnostic for the spatial localization of REs. Analysis of D 2 visible lines indicates that the D 2 molecules in the plasma are thermally equilibrated with the background plasma, with vibrational, rotational, and kinetic temperatures all near 0.3 eV. D 2 spectroscopy therefore serves as a convenient diagnostic of background plasma temperature. As a result, measurement of D 2 radiated power also appears to serve as a useful diagnostic for constraining neutral transport modeling.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Chemically recyclable thermoplastics from reversible-deactivation polymerization of cyclic acetals

Identifying plastics capable of chemical recycling to monomer (CRM) is the foremost challenge in creating a sustainable circular plastic economy. Polyacetals are promising candidates for CRM but lack useful tensile strengths owing to the low molecular weights produced using current uncontrolled cationic ring-opening polymerization (CROP) methods. Here, we present reversible-deactivation CROP of cyclic acetals using a commercial halomethyl ether initiator and an indium(III) bromide catalyst. Using this method, we synthesize poly(1,3-dioxolane) (PDXL), which demonstrates tensile strength comparable to some commodity polyolefins. Depolymerization of PDXL using strong acid catalysts returns monomer in near-quantitative yield and even proceeds from a commodity plastic waste mixture. Our efficient polymerization method affords a tough thermoplastic that can undergo selective depolymerization to monomer.

Abel, Brooks A.↗

Total metals, carbon, nitrogen & anion concentration data; Slate River & East River floodplains, Crested Butte, CO; May 2022-October 2022

This data package includes processed and undiluted measurements for metal, total carbon, total nitrogen, and anion concentrations from pore water (groundwater) and surface water samples from the Slate River and East River floodplains of Crested Butte, CO, focus field sites for the SLAC Floodplain Hydro-Biogeochemistry SFA. The data was generated as part of the work targeting the overarching research question for the SLAC SFA: How do ubiquitous subsurface interfaces mediate molecular-scale biogeochemical processes and groundwater quality in floodplains and watersheds? Samples were collected between May and October of 2022. These measurements were all recorded at the Arizona Laboratory for Emerging Contaminants (ALEC) at the University of Arizona located in Tucson, AZ. Groundwater samples were extracted from a network of installed rhizon (Rhizosphere Research Products, part no. 19.60.21F, 0.6 micrometer mesh size) and piezometer wells within the river floodplain. All water samples were shaded from sun exposure during extraction from the subsurface and preserved at 4C until measured at ALEC.Analysis by ICP-MS (metals):Measurements for total metals were made on the Agilent 7700x ICP-MS (for total metals) – Agilent Technologies, Santa Clara, CA. The analytical QA/QC protocol was adapted from US EPA Method 200.8 for analysis by ICP-MS. Calibration standards were prepared from multi-element stock solutions (SPEX Certiprep, Metuchen, NJ). Calibration curves include at least 7 points with correlation coefficients > 0.995. The QC protocol includes a continuing calibration blank (CCB), a continuing calibration verification (CCV) solution and at least one quality control sample (QCS) to be analyzed just after calibration and again after every 12 samples and at the completion of the run. The QCS solutions are from an independent source, such as NIST SRM 1643e - Trace elements in water, or QCS solutions from High Purity Standards (Charleston, SC). Acceptable QC responses must be between 90 and 110% of the certified value. Lastly, a suitable internal standard (usually Rh, In, Ga or Ge) is added using on-line addition into the sample line and mixing tee.Analysis by Shimadzu TOC-L (TOC/TN):The TOC-L system is a combustion technique where liquid samples are injected and combusted into CO2 for carbon detection by non-dispersive infrared (NDIR) and NO for detection by chemiluminescence. A calibration curve using five standard solutions between 0.1 and 7 ppm for carbon and 0.05 and 3.5 ppm for nitrogen is made for each type of measurement with a linearity >0.99. All samples, standards, and QC’s are prepared in 24mL scintillation vials that have been baked for 4hrs at 475 Cº and made using RO water (18.2mΩ). QC’s include a calibration blank check (CCB), continuing calibration check (CCC), and a certified reference material check (CRM). All QC’s are within ±10% error and are run before and after each batch of samples. Samples are diluted and rerun if any measurement concentrations are above the highest standard.Analysis by Ion Chromatography (Anions):The instrument used is the Thermo Scientific Dionex ICS-6000 using AS+AG22 column set for anion analysis with sodium carbonate eluent. A calibration curve using five standard solutions between 5 and 250 umol/L is made with a linearity >0.99. Standards and QC’s are prepared in 15mL polypropylene conical tubes, pipetted along with the samples into 1.5mL polypropylene vials. Dilutions are made using RO water (18.2mΩ). QC’s include a calibration blank check (CCB), continuing calibration check (CCC), and a certified reference material check (CRM). All QC’s are within ±10% error and are run before and after each batch of samples. Samples are diluted and rerun if any measurement concentrations are above the highest standard.All files are in csv format.

54 ENVIRONMENTAL SCIENCES↗

REDC Process Instrumentation Modernization Project

Critical electronics used for isotopes production have become outdated and difficult to manufacture. In particular the alpha-particle and neutron detection electronics (commonly referred to as Q2809A-9 and -11) which are used to monitor effluent activity in ORNL Building 7920 were designed and deployed in 1966-67. These electronics are still used but some parts are no longer available for purchase. In addition, the printed circuit boards used in the Count Rate Monitor (CRM) module have no fabrication files or quality assurance documentation. In light of this, a project to modernize the modules for ability to manufacture with modern parts was undertaken. Both the preamplifier and CRM were modernized with new printed circuit boards and parts which are current catalog parts. In addition, QA documentation was generated which allows the manufacturer to assure proper operation prior to delivery.

42 ENGINEERING↗

Enhancing Convection Parameterization for Next Generation E3SM (Final Technical Report)

This technical report summarizes the achievements during the project period. The general goal of the project is to enhance the representation of atmospheric deep convection in the DOE global climate model E3SM. By implementing a stochastic convection scheme into E3SM, we improved the simulation of precipitation intensity and frequency. As a result, it has a profound impact on the simulation of other fields in the model, including aerosol scavenging by precipitation and aerosol radiative effects. We also implemented a convective cloud microphysics scheme into E3SMv2 to represent more accurately the interaction between convection and grid-scale clouds. An extensive analysis of model simulations as part of the Next Generation Development (NGD) convection scheme assessment project found that including the convective microphysics scheme improved the simulation of Madden-Julian oscillations (MJO) in the model. To make convective parameterization schemes more scale-aware as the GCM resolution increases, we analyzed the output from cloud-resolving model (CRM) simulations of both organized and unorganized convection by coarse-graining the CRM data to different GCM resolutions. Using a novel approach to modify the convective closure, we demonstrated that the convection scheme used in E3SM (ZM scheme) can be made scale-aware.

54 ENVIRONMENTAL SCIENCES↗

HLPW-4/GMGW-3: High-Order Discretization Technology Focus Group Workshop Summary

This paper summarizes the High-Order Technical Focus Group (HO-TFG) submissions for the joint 4th AIAA High Lift Prediction (HLPW-4) and 3rd Geometry and Mesh Generation Workshop (GMGW-3). The goal of the workshop was to assess the state-of-the-art in mesh generation and computational fluid dynamics software. The Common Research Model High-Lift (CRM-HL) variant served as the primary focus of the workshop, and a two-dimensional airfoil section from the CRM-HL was used as a verification test case. Here, the HO-TFG was tasked with generating high-order curved meshes for both geometries, and computing high-order solutions using both Reynolds-averaged Navier–Stokes and scale-resolving formulations. While limited by computational resources, the final results demonstrate the potential of higher-order methods to increase solution accuracy with a lower degree-of-freedom count relative to second-order discretizations.

42 ENGINEERING↗

High-Order Wall-Modeled Large-Eddy Simulation of High-Lift Configuration

This paper presents the assessment of several recent enhancements for a high-order wall-modeled large-eddy simulation (WMLES) approach and demonstrates order independence with a fixed data exchange location in the wall model. The two enhancements include the use of isotropic tetrahedral elements to improve accuracy and an explicit subgrid-scale model, the Vreman model, to improve accuracy and robustness. The [Formula: see text] study focused on the high-lift Common Research Model (HL-CRM) at the angle of attack of 19.57 deg, a benchmark problem from the 4th AIAA High-Lift Prediction Workshop. Solution polynomial orders of [Formula: see text], and 5 were used in the study. The study demonstrated [Formula: see text] independence in integrated forces, pitch moment, velocity profile in the wall-normal direction, and surface flow topology. It also showed that a [Formula: see text] order of at least 3 ([Formula: see text]) was needed to correctly predict the external inviscid flow and the surface flow topology. Thereafter, [Formula: see text] simulations over several other angles of attack demonstrated that the high-order WMLES approach can correctly predict the maximum lift and flow separation regions for HL-CRM with about 40 million degrees of freedom (DOF) compared to at least 250 million DOF required by second-order methods.

Engineering↗

HLPW-4/GMGW-3: High Order Discretization Technology Focus Group Workshop Summary

This paper summarizes the High-Order Technical Focus Group (HO-TFG) submissions for the joint 4th AIAA High Lift Prediction and 3rd Geometry and Mesh Generation Workshop. The goal of the workshop was to assess the state-of-the-art in mesh generation and computational fluid dynamics software. The Common Research Model High-Lift (CRM-HL) variant served as the primary focus of the workshop, and a 2D airfoil section from the CRM-HL was used as a verification test case. The HO-TFG was tasked with generating high-order curved meshes for both geometries, and computing high-order solutions using both Reynolds Averaged Navier-Stokes and scale resolving formulations. While limited by computational resources, the final results demonstrate the potential of higher-order methods to increase solution accuracy with a lower degree of freedom count relative to second-order discretizations.

Galbraith, Marshall C.↗

230Th/234U radiochronometry for uranium materials by alpha spectrometry for nuclear forensics analysis

We have developed an alpha spectrometry method for 230Th/234U radiochronometry to determine the model separation age for uranium materials. This method offers an alternative to the more commonly used, but significantly more resource intensive multi-collector inductively coupled plasma mass spectrometry (MC-ICP-MS) while providing similar accuracy and precision. The development included radiochemical separation of uranium and thorium, calibration of the 232U tracer and the alpha spectrometry measurement. The method was validated by analyzing a certified reference material, CRM 125-A, which is a uranium oxide pellet assay, isotopic, and radiochronometric standard. The results were compared to those obtained by our routine MC-ICP-MS 230Th/234U radiochronometry analysis method to assess the performance parameters for alpha spectrometry compared to the state-of-the-art technique.

Macsik, Zsuzsanna [Los Alamos National Laboratory ↗

Assessing the availability of two bamboo species for fermentable sugars by alkaline hydrogen peroxide pretreatment

We report this study comprehensively investigated two bamboo species (i.e. Neosinocalamus affinis and Phyllostachys edulis) in terms of their cell wall ultrastructure, chemical compositions, enzymatic saccharification, and lignin structure before and after alkaline hydrogen peroxide pretreatment (AHP). During AHP, Neosinocalamus affinis (NAB) had higher delignification than Phyllostachys edulis (PEB), and thus showed better enzymatic digestibility (93.05% vs 53.57% for glucan). The fundamental chemical behavior of the bamboo lignins was analyzed by fluorescence microscope (FM), confocal Raman microscope (CRM), molecular weight analysis, and 2D HSQC-NMR. Results indicated that the PEB has thicker cell wall and more concentrated lignin in its compound middle lamella and cell corner middle lamella than NAB. Moreover, PEB lignin contains more G units (S/G of 0.95), in evident contrast to that of NAB lignin (S/G of 1.30), which favor the formation of C–C linkages, thus impeding its degradation during the AHP.

59 BASIC BIOLOGICAL SCIENCES↗

Enhanced Pu emission with solution-loaded laser ablation modified sources (SLLAMS) for thermal ionization mass spectrometry

This study presents a new approach to filament modification by laser ablation for analysis of femtograms of plutonium (Pu) by thermal ionization mass spectrometry (TIMS). This method simplifies the often rigorous and labor-intensive sample loading necessary for low-level analyses by TIMS with solution-loaded laser ablation modified sources (SLLAMS). By applying a para-film coating to the surface of the filament and then ablating through the film to reveal metal beneath, a point source is created. A solution containing ppt-levels of Pu can then be applied over the ablated region, dried slowly into the crater, and then carburized. All analyses were made by multiple ion counting system of a Nu Instruments TIMS. Furthermore, we report errors of 10% 2σ for 240 Pu/ 239 Pu of CRM-137 samples totaling 5 – 7 femtograms (fg; 1E-15 g) with an average sample utilization efficiency of 1.3%. Results from SLLAMS demonstrate an improvement in precision, accuracy and ease of use over resin bead loads.

47 OTHER INSTRUMENTATION↗

High-precision measurement of U-Pu-Np-Am concentrations and isotope ratios in environmental reference materials by mass spectrometry

Herein, we report results of precise and sensitive mass spectrometric measurements of uranium, plutonium, neptunium, and americium concentrations and isotope ratios in a variety of environmental reference materials. Most of our work has been done on NIST SRM 4350b, River Sediment, but we also present results for NIST SRM 4354, Lake Sediment; NIST SRMs 4355 and 4355a, Peruvian Soil; NIST SRM 4357, Ocean Sediment; NIST SRM 1648a, Urban Particulate Material; NIST SRM 1649b, Urban Dust; IAEA CRM 385, Ocean Sediment; USGS BCR-2, Columbia River Basalt; and USGS BHVO-2, Hawaiian Volcanic Observatory Basalt. These materials reflect a wide range in long-lived actinide concentrations (e.g. 1E4 to 1E10 atoms 239 Pu/g) and isotope ratios. Measurements were performed in a clean laboratory by isotope dilution, multi-collector thermal ionization and multi-collector inductively coupled plasma mass spectrometry. In general, our results are in agreement with, but lower the uncertainty of, literature or certificate values for these reference materials. Our uranium results for the basalts also confirm previously reported high-precision mass spectrometric results from our laboratory. In many cases our measurements of U-Pu-Np-Am nuclides appear to be novel.

58 GEOSCIENCES↗