Search NASA⌕ Search

SEARCH · Search NASA

Results for “CST”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 55 records · Page 3

EM and beam dynamics modeling of CCL with CST Studio

The 800-MeV proton linac at LANSCE consists of a drift-tube linac, which brings the beam to 100 MeV, followed by a coupled-cavity linac (CCL). Each of 44 CCL modules contain multiple tanks, and it is fed by a single 805-MHz klystron. CCL tanks are multi-cell blocks of identical re-entrant sidecoupled cavities, which are followed by drifts with magnetic quadrupole doublets. Bridge couplers – special cavities displaced from the beam axis – electromagnetically couple CCL tanks over such drifts. We have developed 3D CST models of CCL tanks of the LANSCE linac. Their electromagnetic analysis is performed using MicroWave Studio. Beam dynamics is modeled with Particle Studio for bunch trains with realistic beam distributions using the CST calculated RF fields and quadrupole magnetic fields to determine the output beam parameters.

42 ENGINEERING↗

Tank Closure Cesium Removal Ion Exchange Column CST Characterization: SRNL-STI-2024-00072 (Rev.0) pdf

Savannah River Mission Completion (SRMC) recently suspended operation of the Tank Closure Cesium Removal (TCCR) system which utilized an ion exchange (IX) process to remove radioactive cesium from waste supernate. During the demonstration phase, a total of three batches of Tank 10H dissolved salt waste were processed through the original TCCR columns. Subsequently, dissolved salt waste from Tank 9H was processed through TCCR in a phase referred to as TCCR 1A with four new IX columns. All eight columns have now been moved to Interim Safe Storage (ISS). For each batch processed through the TCCR IX columns, SRNL performed a number of analyses on surface and variable depth samples as well as batch equilibrium contact tests (BECT) to determine equilibrium loadings of Cs on the crystalline silicotitanate (CST) IX media. The BECTs were performed by lowering “teabags” containing ~0.1 g of CST each into the tank for a period of at least 10 days. The teabags were then retrieved and sent to SRNL for digestion and analysis.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Three-Dimensional Simulation of Traveling-Wave Tube Cold-Test Characteristics Using CST MICROWAVE STUDIO

The electromagnetic field simulation software package CST MICROWAVE STUDIO (MWS) was used to compute the cold-test parameters - frequency-phase dispersion, on-axis impedance, and attenuation - for a traveling-wave tube (TWT) slow-wave circuit. The results were compared to experimental data, as well as to results from MAFIA, another three-dimensional simulation code from CST currently used at the NASA Glenn Research Center (GRC). The strong agreement between cold-test parameters simulated with MWS and those measured experimentally demonstrates the potential of this code to reduce the time and cost of TWT development.

Chevalier, Christine T.↗

Update on multipactoring in coaxial waveguides using CST Particle Studio

CST Particle Studio combines electromagnetic field simulation, multi-particle tracking, adequate post-processing and advanced probabilistic emission model, which is the most important new capability in multipactor simulation. The emission model includes in simulation the stochastic properties of emission and adds primary electron elastic and inelastic reflection from the surfaces. The simulation of multipactor in coaxial waveguides have been performed to study the effects of the innovations on the multipactor threshold and the range over which multipactor can occur. The results compared with available previous experiments and simulations as well as the technique of MP simulation with CST PS are presented and discussed.

43 PARTICLE ACCELERATORS↗

Beam Dynamics Simulations in Project X RFQ with CST Studio Suite

Typically the RFQs are designed using the Parmteq, DesRFQ and other similar specialized codes, which produces the files containing the field and geometrical parameters for every cell. The beam dynamic simulations with these analytical fields a re, of course, ideal realizations of the designed RFQs. The new advanced computing capabilities made it possible to simulate beam and even dark current in the realistic 3D electromagnetic fields in the RFQs that may reflect cavity tuning, presence of tune rs and couplers, RFQ segmentation etc. The paper describes the utilization of full 3D field distribution obtained with CST Studio Suite for beam dynamic simulations using both PIC solver of CST Particle Studio and the beam dynamic code TRACK.

43 PARTICLE ACCELERATORS↗

AmeriFlux BR-CST Caatinga Serra Talhada

This is the AmeriFlux version of the carbon flux data for the site BR-CST Caatinga Serra Talhada. Site Description - This tower is located in a seasonal tropical dry forest (caatinga) in the semi-arid region of Brazil. There is no wood extraction for at least 50 years, and because it is an open area, there is cattle grazing during the wet season.

Antonino, Antonio↗

AmeriFlux US-Cst Crossett Experimental Forest

This is the AmeriFlux version of the carbon flux data for the site US-Cst Crossett Experimental Forest. Site Description - The study takes place in the Crossett Experimental Forest (CEF, 32°2′ N, 91°57′ W), which was established in 1934 with the objective of developing effective management protocols for loblolly and shortleaf pine forests in the Gulf Coastal Plain. Mean annual temperature and precipitation are 17.6 °C and 1,410 mm, respectively. Most of the soils on and near the CEF are silt loams (primarily Glossaquic Fragiudalfs). The tower is situated in the the old-growth pine management sector of the CEF, which emphasizes management for old-growth-like conditions, with the goal of emulating the structural and compositional attributes of historic forests from this region using a combination of timber harvesting, prescribed fire, and other tools. This includes periodic commercial logging of intermediate-sized loblolly pines to support further restoration treatments, such as prescribed fire, hardwood and exotic species competition control, and the increase of plant species more compatible with fire (e.g., shortleaf pine and understory grasses)

Novick, Kim↗

Evaluating the use of PAO (4 cSt polyalphaoelfin) oil instead of DOP (di-octyl phthalate) oil for measuring the aerosol capture of nuclear canister filters

This document details the distinction between using PAO (4 cSt polyalphaoelfin) oil instead of DOP (di-octyl phthalate) oil for measuring the aerosol capture of filters. This document is developed to justify the use of PAO rather than DOP for evaluating the performance of filters in the SAVY 4000 and Hagan containers. The design criteria (Anderson et al, 2012) for purchasing SAVY 4000 containers and the Safety Analysis Report for the SAVY 4000 Container Series specified that the filter must “capture greater than 99.97% of 0.45 μm mean diameter dioctyl phthalate (DOP) aerosol at the rated flow with a DOP concentration of 65±15 micrograms per liter.”This corresponds to a leakage percent of 0.03% (3.0x10 -2 ). The density of DOP oil is 985 kg/m 3 and the density of PAO oil is 819 kg/m 3 . ATI Test Inc measured the mass mean diameter of aerosol distributions produced by a single Laskin type III-A nozzle operating at a 20 psig air pressure as 0.563 μm for DOP oil and 0.549 μm for PAO oil. (See Appendix A.) For both types of oil in this document, the single fiber method calculated the leakage percent to be 4.4x10 -5 for DOP oil and 4.7x10 -5 for PAO oil. Although the percent error between these two quantities is 7.7%, these calculated leakage percent values are more than two orders of magnitude less than the criterion specified in the SAVY canister SAR. As a point of reference, the photometer used to measure the SAVY canister filter performance cannot resolve values for the leakage percent below 1.0x10 -5 . Additionally, over a range of particle sizes from 0.01 μm to 3.0 μm, there was less than 4.0x10 -5 error between the calculated filter efficiency for the two types of oil at any particular particle size diameter. In conclusion, the difference between using DOP and PAO for testing SAVY canister filters is of inconsequential concern.

61 RADIATION PROTECTION AND DOSIMETRY↗

Cold Crucible Vitrification of CST and Simulated Hanford Tank Waste

The Direct Feed Low-Activity Waste (DFLAW) flowsheet provides for the initial production of immobilized low-activity waste (ILAW) by feeding low-activity waste (LAW) from tank farms to the Hanford Waste Treatment and Immobilization Plant (WTP) LAW Facility for immobilization. Prior to the transfer of feed to the WTP LAW Vitrification Facility, tank supernatant waste will be pretreated by the Tank-Side Cesium Removal (TSCR) system to meet the WTP LAW waste acceptance criteria (<3.18× 10 -5 Ci 137 Cs/mole of Na). This pretreatment will remove cesium from the waste stream through ion exchange (IX). The selected media for IX is crystalline silicotitanate (CST).

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

PIP-II Beam Current Monitor Fault Case & Beam Position Monitor Linearity Studies in CST Studio

The use of non-invasive sensors & systems to measure particle beam characteristics is a crucial part of modern accelerator control systems. As such, simulations predicting the behavior of these sensors are essential for guiding beamline control system design. This poster details the results returned by two beam sensor models created using CST Studio software: the signal linearity of an elliptical beam position monitor (BPM), and the fault cases of an AC current transformer (ACCT) beam current monitor (BCM).

Rouzky, Adam↗

NASA CST aids U.S. industry

The effect of NASA's computational structures Technology (CST) research on aerospace vehicle design and operation is discussed. The application of this research to proposed version of a high-speed civil transport, to composite structures in aerospace, to the study of crack growth, and to resolving field problems is addressed.

Housner, Jerry M.↗

Development of CST(registered) for a Solventless Sprayable Coating, MCC-1

This paper discusses an innovative process called convergent spray technology (CST), as applied to the development and successful implementation of MCC-1 coating for the Shuttle/SRB as a primary Thermal Protection System (TPS). The session will illustrate the environmental and the process benefits of the MCC-1 technology, show the systematic steps taken for the development of the technology that included statistically conducted sensitivity studies of about 34 variables, and illustrate that the technology is "Field-proven" based on the process and post-flight successes on the Shuttle/SRB. The application of this technology to other aerospace and commercial programs will be introduced to illustrate the wide range of possibilities.

Patel, A. K.↗

A Comparison of Three-Dimensional Simulations of Traveling-Wave Tube Cold-Test Characteristics Using CST MICROWAVE STUDIO and MAFIA

Previously, it was shown that MAFIA (solutions of Maxwell's equations by the Finite Integration Algorithm), a three-dimensional simulation code, can be used to produce accurate cold-test characteristics including frequency-phase dispersion, interaction impedance, and attenuation for traveling-wave tube (TWT) slow-wave structures. In an effort to improve user-friendliness and simulation time, a model was developed to compute the cold-test parameters using the electromagnetic field simulation software package CST MICROWAVE STUDIO (MWS). Cold-test parameters were calculated for several slow-wave circuits including a ferruled coupled-cavity, a folded waveguide, and a novel finned-ladder circuit using both MWS and MAFIA. Comparisons indicate that MWS provides more accurate cold-test data with significantly reduced simulation times. Both MAFIA and MWS are based on the finite integration (FI) method; however, MWS has several advantages over MAFIA. First, it has a Windows based interface for PC operation, making it very user-friendly, whereas MAFIA is UNIX based. MWS uses a new Perfect Boundary Approximation (PBA), which increases the accuracy of the simulations by avoiding stair step approximations associated with MAFIA's representation of structures. Finally, MWS includes a Visual Basic for Applications (VBA) compatible macro language that enables the simulation process to be automated and allows for the optimization of user-defined goal functions, such as interaction impedance.

Chevalier, C. T.↗

Traveling-Wave Tube Cold-Test Circuit Optimization Using CST MICROWAVE STUDIO

The internal optimizer of CST MICROWAVE STUDIO (MWS) was used along with an application-specific Visual Basic for Applications (VBA) script to develop a method to optimize traveling-wave tube (TWT) cold-test circuit performance. The optimization procedure allows simultaneous optimization of circuit specifications including on-axis interaction impedance, bandwidth or geometric limitations. The application of Microwave Studio to TWT cold-test circuit optimization is described.

Chevalier, Christine T.↗

Initial PIP-II Beam Current Monitor Fault Case Analyses & Beam Position Monitor Linearity Studies in CST Studio Suite

The use of non-invasive sensors & systems to measure particle beam characteristics is a crucial part of modern accelerator control systems due to their ability to return real time beam data while minimizing negative effects on beam quality. To ensure that one can be reasonably confident these sensors will behave as desired upon be-ing implemented within the beamline, simulations pre-dicting the performance of these sensors under beamline conditions can be used as a valuable tool for checking sensor functionality without a physical test bench. This paper details the design, testing, and results of two sensor models developed using CST Studio Suite soft-ware designed to mimic two sensors to be implemented within the PIP-III beamline: an elliptical, large-aperture beam position monitor (BPM) for which vertical & hori-zontal position signal linearity was analyzed, and an AC current transformer (ACCT) beam current monitor (BCM) used to search for potential fault cases within the BCM and beam pipe flange gaps. Special focus is given to the discovery of linearity variations within the BPM and the use of frequency domain techniques in the BCM fault case analyses.

Rouzky, A. R.↗

Enhanced prediction of Cs removal by CST from Hanford tank waste with K accountability

Abstract The treatment of Hanford tank waste is one of the most challenging environmental cleanup activities to date. To expedite the processing of liquid waste stored in underground tanks in Washington State it is necessary to remove the significant dose contributor, 137 Cs. Crystalline silicotitanate ion exchanger is currently used to remove 137 Cs from the aqueous phase of Hanford tank wastes in preparation for vitrification at the Waste Treatment and Immobilization Plant (WTP). Improving the understanding of potassium impacts on ion exchange behavior of Cs will help in the operation of a critical component of one of the most complex treatment processes in the world today. Optimization of this process can result in significant cost savings and less waste production. Toward this effort, a series of batch contact tests varied in potassium concentration were conducted to look at the impact of potassium concentration on Cs distribution. Experimental distribution ratios ( K d ) were compared to the distribution ratios predicted using the ZAM model. A significant underprediction of Cs capacity in the presence of potassium was seen with the existing model. A revision of the equilibrium constants was determined and provided a statistically better fit for determining the Cs K d values in tank waste matrices.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Evaluation of Navy 9 cst Oil in Bell Helicopter M412 HP Gearboxes

Tests were conducted with 5 and 9 centistoke lubricants in three different helicopter gearboxes, a main transmission, a 42' gearbox and a tailrotor gearbox. The objective of the tests was to observe and measure the difference in the performance of the lubrication systems due to the viscosity difference between the two test lubricants. The 9 centistoke oil has been developed to provide higher component film thickness, increased load carrying capacity and improved corrosion resistance which will provide increased life for drive system gears and bearings.

TRANSMISSION FLUIDS↗