Search NASA⌕ Search

SEARCH · Search NASA

Results for “CT-GUIDED RADIOTHERAPY”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 55 records · Page 3

SU-F-T-289: MLC Fluence Sonogram Based Delivery Quality Assurance for Bilateral Breast Irradiation

Purpose: Performing DQA for Bilateral (B-L) breast tomotherapy is a challenging task due to the limitation of any commercially available detector array or film. Aim of this study is to perform DQA for B-L breast tomotherapy plan using MLC fluence sinogram. Methods: Treatment plan was generated on Tomotherapy system for B-L breast tumour. B-L breast targets were given 50.4 Gy prescribed over 28 fractions. Plan is generated with 6 MV photon beam & pitch was set to 0.3. As the width of the total target is 39 cm (left & right) length is 20 cm. DQA plan delivered without any phantom on the mega voltage computed tomography (MCVT) detector system. The pulses recorded by MVCT system were exported to the delivery analysis software (Tomotherapy Inc.) for reconstruction. The detector signals are reconstructed to a sonogram and converted to MLC fluence sonogram. The MLC fluence sinogram compared with the planned fluence sinogram. Also point dose measured with cheese phantom and ionization chamber to verify the absolute dose component Results: Planned fluence sinogram and reconstructed MLC fluence sinogram were compared using Gamma metric. MLC positional difference and intensity of the beamlet were used as parameters to evaluate gamma. 3 mm positional difference and 3% beamlet intensity difference were used set for gamma calculation. A total of 26784 non-zero beamlets were included in the analysis out of which 161 beamlets had gamma more than 1. The gamma passing rate found to be 99.4%. Point dose measurements were within 1.3% of the calculated dose. Conclusion: MLC fluence sinogram based delivery quality assurance performed for bilateral breast irradiation. This would be a suitable alternate for large volume targets like bilateral breast, Total body irradiation etc. However conventional method of DQA should be used to validate this method periodically.

60 APPLIED LIFE SCIENCES↗

SU-F-T-296: Modulated Therapy Down Under: A Survey of IMRT & VMAT Physics Practice in Australia and New Zealand

Purpose: A comprehensive survey of Australasian radiation oncology physics departments was undertaken to capture a snapshot of current usage, commissioning and QA practices for intensity-modulated therapies. Methods: An online survey was developed and advertised to Australian and New Zealand radiation oncology physicists through the local college (ACPSEM) in April 2015. The survey consisted of 147 questions in total, covering IMRT, VMAT and Tomotherapy, and details specific to different treatment planning systems. Questions captured detailed information on equipment, policies and procedures for the commissioning and QA of each treatment technique. Results: 41 partial or complete responses were collected, representing 59 departments out of the 78 departments operational. 137 and 84 linacs from these departments were using IMRT and VMAT respectively, from a total 150 linacs. 100% and 78% of respondents were treating with IMRT and VMAT respectively. There are at least 8 different treatment planning systems being used for IMRT or VMAT, and large variations in all aspects of QA policies and procedures. 29 responses indicated 72 methods routinely used for pre-treatment QA, when breaking down by device and analysis type. Similar numbers of departments use field-by-field analysis compared to composite analysis (56% to 44%) while a majority use true gantry angle delivery compared to fixed gantry at 0° (72% to 28%). 19 different implementations of gamma index analysis parameters were reported from 33 responses. A follow-up one-day workshop to highlight the results, discuss the role of QA and share equipment-specific knowledge across users was conducted in November 2015. Conclusion: While IMRT and VMAT are almost universally available in Australasia, large variations in practice indicate a need for national or consensus guidelines.

60 APPLIED LIFE SCIENCES↗

SU-F-T-389: Validation in 4D Dosimetry Using Dynamic Phantom

Purpose: Tumor motion due to respiration causes the uncertainties during the radiotherapy. This study aims to find the differences between planning dose by treatment planning and the received dose using dynamic phantom. Methods: Respiratory motion was simulated by the DYNAMIC THORAX PHANTOM (Model 008A). 4D-CT scans and maximum intensity projection (MIP) images for GTV were acquired for analysis. The amplitude of craniocaudal tumor motion including 2mm, 5mm, 10mm and 20mm with 3cm2 tumor size were performed in this study. The respiratory cycles of 4-seconds and 6-seconds were included as the different breathing modes. IMRT, VAMT, and Tomotherapy were utilized for treatment planning. Ion chamber and EBT3 were used to measure the point dose and planar dose. Dose distributions with different amplitudes, respiratory cycles, and planning techniques were all measured and compared to calculations. Results: The variations between the does measurements and calculation dose by treatment planning system were found in both point dose and dose distribution. The 0.83% and 5.46 % differences in dose average were shown on phantom with motions using 2mm amplitude in 4 second respiratory cycle, and 20mm amplitude in 4 second respiratory cycle, respectively. The most point dose overestimation as compared of the calculations was shown the plan generated by Tomotherapy. The underestimations of planar dose as compared of calculations was found in the 100% coverage doses for GTV. Conclusion: The loss of complete (100%) GTV coverage was the predominant effect of respiratory motion observed in this study. Motion amplitude and treatment planning system were the major factors leading the dose measurement variation as compared of planning calculations.

60 APPLIED LIFE SCIENCES↗

SU-F-T-435: Helical Tomotherapy for Craniospinal Irradiation: What We Have Learned from a Multi-Institutional Study

Purpose: To report cranio-spinal irradiation (CSI) planning experience, compare dosimetric quality and delivery efficiency with Tomotherapy from different institutions, and to investigate effect of planning parameters on plan quality and treatment time. Methods: Clinical helical tomotherapy IMRT plans for thirty-nine CSI cases from three academic institutions were retrospectively evaluated. The planning parameters: field width (FW), pitch, modulation factor (MF), and achieved dosimetric endpoints were cross-compared. A fraction-dose-delivery-timing index (FDTI), defined as treatment time per fraction dose per PTV length, was utilized to evaluate plan delivery efficiency. A lower FDTI indicates higher delivery efficiency. We studied the correlation between planning quality, treatment time and planning parameters by grouping the plans under specific planning parameters. Additionally, we created new plans using 5cm jaw for a subset of plans that used 2.5cm jaw to exam if treatment efficiency can be improved without sacrificing plan quality. Results: There were significant dosimetric differences for organ at risks (OARs) among different institutions (A,B,C). Using the lowest average MF (1.9±0.4) and 5cm field width, C had the highest lung, heart, kidney, liver mean doses and maximum doses for lens. Using the same field width of 5cm, but higher MF (2.6±0.6), B had lower doses to the OARs in the thorax and abdomen area. Most of A’s plans were planned with 2.5cm jaw, the plans yielded better PTV coverage, higher OAR doses and slightly shorter FDTI compared to institution B. The replanned 5cm jaw plans achieved comparable PTV coverage and OARs sparing, while saving up to 44.7% treatment time. Conclusion: Plan quality and delivery efficiency could vary significantly in CSI planning on Tomotheapy due to choice of different planning parameters. CSI plans using a 5cm jaw, with proper selection of pitch and MF, can achieve comparable/ better plan quality with shorter delivery time compared to 2.5cm jaw plans.

60 APPLIED LIFE SCIENCES↗

SU-F-T-445: Effect of Triaxial Cables and Microdetectors in Small Field Dosimetry

Purpose: Advances in radiation treatment especially with smaller fields used in SRS, Gamma knife, Tomotherapy, Cyberknife, and IMRT, require a high degree of precision especially with microdetectors for small field dosimetry (Das et al, Med Ph, 35, 206, 2008; Alfonso et al, Med Phys, 35, 5179, 2008). Due to small signal, the triaxial cable becomes critical in terms of signal to noise ratio (SNR) which is studied with microdetectors. Methods: Six high quality triaxial cables, 9.1 meters long from different manufacturers without any defects were acquired along with 5 most popular microdetectors (microdiamond, plastic scintillators, SRS-diode, edge-diode and pinpoint). A dedicated electrometer was used for each combination except W1 which has its own supermax electrometer. A 6MV photon beam from Varian True beam with 100 MU at a 600 MU/min was used. Measurements were made at a depth of 5 cm in water phantom. Field sizes were varied from 0.5 cm to 10 cm square fields. Readings were taken with combination of cables and microdetectors. Results: Signal is dependent on the quality of the connectors, cables and types of microdetector. The readings varied from nC to pC depending on the type of microdetector. The net signal, S, (Sc-Sn), where Sc is signal with chamber and Sn is without chamber is a linear function of sensitive volume, v; (S = α+β•V), where α and β are constants. The standard deviation (SD) in 3 sets of reading with each combination of cable-detector was extremely low <0.02%. As expected the SD is higher in small fields (<3cm). Maximum estimated error was only ±0.2% in cables-detector combinations. Conclusion: The choice of cables has relatively small effect (±0.2%) with microdosimeter and should be accounted in overall error estimation in k value that is needed to convert ratio of reading to dose in small field dosimetry.

60 APPLIED LIFE SCIENCES↗

SU-F-T-456: Tomotherapy MLC Synchronization and Leaf Open Time Measurements Using ArcCheck

Purpose: To develop a practical method for routine QA of the MLC of a Tomotherapy unit using ArcCheck. Methods: Two standard test plans were used in this study. One was a helical test, in which the central leaves No. 32 and 33 opened simultaneously for 277.8ms at projections centered at 0°, 120° and 240° gantry angles. The other test plan was a static test with the gantry angle set at 0°, 45°, 90° and 135° respectively and leaves No. 32 and 33 opened sequentially for total 20s which was further divided into eleven or ten segments at each beam angle. The ArcCheck was isocentrically set up and adjusted for couch sag. Movie files which took a snapshot exposure every 50ms were recorded. The start/stop time of leaf open was decided by the ramp-up/ramp-down of the detectors. Results: The percentage differences between measured and planned leaf open time were calculated to be within 0.5% in all the tests. In static test, if leaves are synchronized perfectly, the sum of the two detectors’ signals after normalization should equal one when the leaves are in transition. Our results showed mean values of 0.982, 0.983, 0.978 and 0.995 at static gantry angle 0°, 45°, 90° and 135° respectively. Conclusion: A method for estimating the Tomotherapy binary MLC leaf open time using ArcCheck is proposed and proved to be precise enough to verify the planned leaf open time as small as 277.8ms. This method also makes the observation and quantification of the synchronization of leaves possible.

60 APPLIED LIFE SCIENCES↗

SU-F-T-457: A Filmless Method for Measurement of Couch Translation Per Gantry Rotation and Couch Speed for Tomotherapy Using ArcCheck

Purpose: To develop a filmless methodology based on an ArcCheck for QA measurement of the couch translation per gantry rotation and couch speed of a Tomotherapy unit. Methods: Two test plans recommended by TG148 were chosen for this study. A helical plan with 1 cm field size opened the leaves for 180 degrees at the 2nd, 7th and 12th of total 13 rotations and was used to verify if the couch travelled the expected distance per gantry rotation. The other test plan was a static plan with the gantry at 0°, 1cm field width and constant couch movement speed of 0.5mm/s. It was used for couch speed measurement. The ArcCheck was isocentrically set up and recorded movie files which took a snapshot exposure every 50ms. Due to the spiral pattern of diodes distribution, when one of the diodes of the ArcCheck located at the beam center, the dose profile as measured by the row of diodes which surrounded the center diode should have a symmetrical pattern. We divided the profile into left half A and right half B. Then a shape parameter was defined as S=Σ|(A−B)|/Σ(A+B). By searching the local minimum of S parameter, the beam center at different time could be located. The machine trajectory log data were also collected and analyzed for comparison. Results: The mean value of measured couch translation and couch speed by ArcCheck had less than 0.05% deviation from the planned values. For couch speed measurement, our result showed a mean value of 0.5002 with an uncertainty ±0.0031, which agreed very well with both the plan setting of 0.5 mm/s and the machine log data of 0.5005 mm/s. Conclusion: Couch translation measured using ArcCheck is accurate and comparable to the film-based measurement. This filmless method also provides a convenient and independent way for measuring couch speed.

61 RADIATION PROTECTION AND DOSIMETRY↗

SU-F-T-468: Efficient Scanning Data Analysis for TomoTherapy

Purpose: The standard TomoTherapy 2D scanning system requires manual analysis using spreadsheets or similar software. Manual analysis is time consuming and does not allow efficient use of the medical physicist or timely results that may indicate issues during the acquisition of data. The purpose of this study is to determine if an in-house solution can provide timely analysis of TomoTherapy scan data. Methods: A custom MATLAB program utilizing a streamlined graphical interface was developed to interpret the native scanning data acquired by the TomoTherapy Electrometer Measurement System (TEMS). The gold beam data provided by the manufacturer was used as a baseline for the acquired data. Two separate sets of scan data were used including longitudinal, transverse, and percent depth dose (PDD). The scan data were compared visually in an overlay and analytically for each beam width using the full width half max (FWHM) for longitudinal profiles and difference inside the field core for the transverse profiles as recommended by TG-148. A plot of the PDD percent error at each point along the curve was generated to show agreement. The time to analysis was measured on a laptop running an Intel i5 processor with 8GB of RAM. Results: The software program required on average less than 5 seconds to load and analyze the results. No conversion or reformatting of the data was required. This allowed real-time visualization of the comparison to the gold beam data as well as the parameters recommended by TG-148. The average percent difference was 0.3% for the longitudinal profiles and 0.1% for the transverse profiles. All PDD data was less than 1% different beyond dmax. Conclusion: We have developed a tool to analyze TomoTherapy scan data in real-time. This allows an efficient method to perform beam commissioning, annual QA, and adjust the beam parameters if necessary.

61 RADIATION PROTECTION AND DOSIMETRY↗

SU-F-T-485: Independent Remote Audits for TG51 NonCompliant Photon Beams Performed by the IROC Houston QA Center

Purpose: IROC-H conducts external audits for output check verification of photon and electron beams. Many of these beams can meet the geometric requirements of the TG 51 calibration protocol. For those photon beams that are non TG 51 compliant like Elekta GammaKnife, Accuray CyberKnife and TomoTherapy, IROC-H has specific audit tools to monitor the reference calibration. Methods: IROC-H used its TLD and OSLD remote monitoring systems to verify the output of machines with TG 51 non compliant beams. Acrylic OSLD miniphantoms are used for the CyberKnife. Special TLD phantoms are used for TomoTherapy and GammaKnife machines to accommodate the specific geometry of each machine. These remote audit tools are sent to institutions to be irradiated and returned to IROC-H for analysis. Results: The average IROC-H/institution ratios for 480 GammaKnife, 660 CyberKnife and 907 rotational TomoTherapy beams are 1.000±0.021, 1.008±0.019, 0.974±0.023, respectively. In the particular case of TomoTherapy, the overall ratio is 0.977±0.022 for HD units. The standard deviations of all results are consistent with values determined for TG 51 compliant photon beams. These ratios have shown some changes compared to values presented in 2008. The GammaKnife results were corrected by an experimentally determined scatter factor of 1.025 in 2013. The TomoTherapy helical beam results are now from a rotational beam whereas in 2008 the results were from a static beam. The decision to change modality was based on recommendations from the users. Conclusion: External audits of beam outputs is a valuable tool to confirm the calibrations of photon beams regardless of whether the machine is TG 51 or TG 51 non compliant. The difference found for TomoTherapy units is under investigation. This investigation was supported by IROC grant CA180803 awarded by the NCI.

60 APPLIED LIFE SCIENCES↗

SU-F-T-489: 4-Years Experience of QA in TomoTherapy MVCT: What Do We Look Out For?

Purpose: To evaluate the QA results of TomoTherapy MVCT from March 2012 to February 2016, and to identify issues that may affect consistency in HU numbers and reconstructed treatment dose in MVCT. Methods: Monthly QA was performed on our TomoHD system. Phantom with rod inserts of various mass densities was imaged in MVCT and compared to baseline to evaluate HU number consistency. To evaluate treatment dose reconstructed by delivered sinogram and MVCT, a treatment plan was designed on a humanoid skull phantom. The phantom was imaged with MVCT and treatment plan was delivered to obtain the sinogram. The dose reconstructed with the Planned Adaptive software was compared to the dose in the original plan. The QA tolerance for HU numbers was ±30 HU, and ±2% for discrepancy between original plan dose and reconstructed dose. Tolerances were referenced to AAPM TG148. Results: Several technical modifications or maintenance activities to the system have been identified which affected QA Results: 1) Upgrade in console system software which added a weekly HU calibration procedure; 2) Linac or MLC replacement leading to change in Accelerator Output Machine (AOM) parameters; 3) Upgrade in planning system algorithm affecting MVCT dose reconstruction. These events caused abrupt changes in QA results especially for the reconstructed dose. In the past 9 months, when no such modifications were done to the system, reconstructed dose was consistent with maximum deviation from baseline less than 0.6%. The HU number deviated less than 5HU. Conclusion: Routine QA is essential for MVCT, especially if the MVCT is used for daily dose reconstruction to monitor delivered dose to patients. Several technical events which may affect consistency of this are software changes, linac or MLC replacement. QA results reflected changes which justify re-calibration or system adjustment. In normal circumstances, the system should be relatively stable and quarterly QA may be sufficient.

60 APPLIED LIFE SCIENCES↗

SU-F-T-529: Dosimetric Investigation of a Rotating Gamma Ray System for ImagedGuided Modulated Arc Radiotherapy

Purpose: Because of their effectiveness and efficiency, rotational arc radiotherapy (MAT) techniques have been developed on both specialty machines such as Tomotherapy and conventional linear accelerators. This work investigates a new rotating Gamma therapy system for image guided MAT and SBRT of intra/extracranial tumors. Methods: The CyberMAT system (Cyber Medical Corp., China) consists of a ring gantry with a gamma source (effective source size 1cm and 1.7cm respectively), a 120-leaf MLC, a kV CBCT and an EPID. The treatment couch provides 6-degrees-of-freedom motion compensation and the kV CBCT system has a spatial resolution of 0.4mm for target localization. The maximum dose rate is >4.0 Gy/min and the maximum field size is 40cm × 40cm. Monte Carlo simulations were used to compute dose distributions and compare with measurements. A retrospective study of 125 previously treated SBRT patients was performed to evaluate the dosimetric characteristics of CyberMAT in comparison with existing VMAT systems. Results: Monte Carlo results confirmed the CyberMAT design parameters including output factors and 3D dose distributions. Its beam penumbra is 5mm to 10mm for field sizes 1cm to 10cm, respectively and its isocenter accuracy is <0.5mm. Compared to the 6 MV photons of Tomotherapy and conventional linacs, Cobalt beams produce lower-energy secondary electrons that exhibit better dose properties in low-density lung tissues. Cobalt beams are ideal for peripheral lung tumors with half-arc arrangements to spare the opposite lung and other critical structures. Superior dose distributions have been obtained for brain, head and neck, breast, spine and lung tumors with half/full arc arrangements. Conclusion: Because of the unique dosimetric properties of Cobalt sources and its accurate stereotaxy/dose delivery CyberMAT is ideally suited for image guided MAT and SBRT. Full-arc arrangements are superior for brain and H&N treatments while half-arc arrangements produce best dose distributions for thoracic tumors.

60 APPLIED LIFE SCIENCES↗

SU-G-BRA-14: Dose in a Rigidly Moving Phantom with Jaw and MLC Compensation

Purpose: To validate dose calculation for a rigidly moving object with jaw motion and MLC shifts to compensate for the motion in a TomoTherapy™ treatment delivery. Methods: An off-line version of the TomoTherapy dose calculator was extended to perform dose calculations for rigidly moving objects. A variety of motion traces were added to treatment delivery plans, along with corresponding jaw compensation and MLC shift compensation profiles. Jaw compensation profiles were calculated by shifting the jaws such that the center of the treatment beam moved by an amount equal to the motion in the longitudinal direction. Similarly, MLC compensation profiles were calculated by shifting the MLC leaves by an amount that most closely matched the motion in the transverse direction. The same jaw and MLC compensation profiles were used during simulated treatment deliveries on a TomoTherapy system, and film measurements were obtained in a rigidly moving phantom. Results: The off-line TomoTherapy dose calculator accurately predicted dose profiles for a rigidly moving phantom along with jaw motion and MLC shifts to compensate for the motion. Calculations matched film measurements to within 2%/1 mm. Jaw and MLC compensation substantially reduced the discrepancy between the delivered dose distribution and the calculated dose with no motion. For axial motion, the compensated dose matched the no-motion dose within 2%/1mm. For transverse motion, the dose matched within 2%/3mm (approximately half the width of an MLC leaf). Conclusion: The off-line TomoTherapy dose calculator accurately computes dose delivered to a rigidly moving object, and accurately models the impact of moving the jaws and shifting the MLC leaf patterns to compensate for the motion. Jaw tracking and MLC leaf shifting can effectively compensate for the dosimetric impact of motion during a TomoTherapy treatment delivery.

60 APPLIED LIFE SCIENCES↗

SU-G-TeP2-12: IROCHouston and MDAPL SRS Anthropomorphic Phantom Results

Purpose: To report the results of SRS phantom irradiations Methods: Anthropomorphic SRS head phantoms were sent to institutions participating in NCI sponsored SRS clinical trials and institutions interested in verifying SRS treatment delivery. The phantom shell was purchased from Phantom Laboratory and altered to house dosimetry and imaging inserts. The imaging insert has 1.9 cm diameter spherical target. The dosimetry insert holds two TLD capsules and radiochromic film in the coronal and sagittal planes through the center of the target. Institutions were asked to image, plan and treat the phantom as they would an SRS patient. GammaKnife, CyberKnife and c-arm accelerator institutions were asked to cover the target with 15 Gy, 20 Gy and 25 Gy, respectively. Following these guidelines and typical planning protocols for these three types of machines gives roughly 30 Gy to the center of the target for all units. Submission of the DICOM digital data set was required for analysis. Criteria of 5% for TLD results and 85% of pixels passing 5%/3mm gamma analysis were applied beginning in 2013. Results: The phantom was analyzed 269 times between the beginning of 2013 to present. The pass rate is 81%. Nineteen of the irradiation results failed only the TLD criteria, 19 failed only the film criteria and 12 failed both. Irradiations included 32 CyberKnife 23 GammaKnife, 3 TomoTherapy and 211 c-arm units. Planning systems included Eclipse, Ergo, GammaPlan, Hi-Art, iPlan, Monaco, MultiPlan, Pinnacle, RayStation, XiO and XKnife. Irradiations that were not accompanied with DICOM data were not included in this analysis. Conclusion: The phantom is a valuable end-to-end test used to independently verify the accuracy of SRS treatment delivery. This investigation was supported by IROC grant CA180803 awarded by the NCI.

60 APPLIED LIFE SCIENCES↗

TU-E-TOUR-T-00: Exhibit Hall Guided Tours-Microdosimeters for Therapy (Tuesday)

Tour Leader: Indra Das, NYU Langone Medical Center, New York, NY Tour Guides: Hsui Ai, Indiana University School of Medicine, Indianapolis, IN Aaron Andersen, Indiana University School of Medicine, Indianapolis, IN Olga Volotoskova, NYU Langone Medical Center, New York, NY Participating Vendors: IBA PTW – New York RTI Electronics, Inc. Standard Imaging, Inc. Sun Nuclear Corporation Small fields are increasing used in specialized radiation treatments such as Gammaknife, Cyberknife, Tomotherapy, IMRT, VMAT, SRS and SBRT. Due to small field size electron transport creates lateral electronic disequilibrium and thus dosimetry could be very difficult. Microdetectors are used for small field dosimetry which will be discussed in preface of this tour as below: Understanding small field e.g. meaning and definition of small field IAEA definition and approach Characteristics of microdetectors in terms of perturbation, recombination, correction Suitability of microdetectors in small field dosimetry.

60 APPLIED LIFE SCIENCES↗

WE-DE-BRA-09: Fast Megavoltage CT Imaging with Rapid Scan Time and Low Imaging Dose in Helical Tomotherapy

Purpose: Megavoltage computed tomography (MVCT) imaging has been widely used for daily patient setup with helical tomotherapy (HT). One drawback of MVCT is its very long imaging time, owing to slow couch speed. The purpose of this study was to develop an MVCT imaging method allowing faster couch speeds, and to assess its accuracy for image guidance for HT. Methods: Three cadavers (mimicking closest physiological and physical system of patients) were scanned four times with couch speeds of 1, 2, 3, and 4 mm/s. The resulting MVCT images were reconstructed using an iterative reconstruction (IR) algorithm. The MVCT images were registered with kilovoltage CT images, and the registration errors were compared with the errors with conventional filtered back projection (FBP) algorithm. Moreover, the fast MVCT imaging was tested in three cases of total marrow irradiation as a clinical trial. Results: Three-dimensional registration errors of the MVCT images reconstructed with the IR algorithm were significantly smaller (p < 0.05) than the errors of images reconstructed with the FBP algorithm at fast couch speeds (3, 4 mm/s). The scan time and imaging dose at a speed of 4 mm/s were reduced to 30% of those from a conventional coarse mode scan. For the patient imaging, a limited number of conventional MVCT (1.2 mm/s) and fast MVCT (3 mm/s) reveals acceptable reduced imaging time and dose able to use for anatomical registration. Conclusion: Fast MVCT with IR algorithm maybe clinically feasible alternative for rapid 3D patient localization. This technique may also be useful for calculating daily dose distributions or organ motion analyses in HT treatment over a wide area.

60 APPLIED LIFE SCIENCES↗

WE-C-TOUR-T-00: Exhibit Hall Guided Tours-Microdosimeters for Therapy (Wednesday) WE-C-TOUR-T-01

Tour Leader: Indra Das, NYU Langone Medical Center, New York, NY Tour Guides: Hsui Ai, Indiana University School of Medicine, Indianapolis, IN Paulina Galvis, NYU Langone Medical Center, New York, NY Olga Volotoskova, NYU Langone Medical Center, New York, NY Participating Vendors: IBA PTW – New York RTI Electronics, Inc. Standard Imaging, Inc. Sun Nuclear Corporation Small fields are increasing used in specialized radiation treatments such as Gammaknife, Cyberknife, Tomotherapy, IMRT, VMAT, SRS and SBRT. Due to small field size electron transport creates lateral electronic disequilibrium and thus dosimetry could be very difficult. Microdetectors are used for small field dosimetry which will be discussed in preface of this tour as below: Understanding small field e.g. meaning and definition of small field IAEA definition and approach Characteristics of microdetectors in terms of perturbation, recombination, correction Suitability of microdetectors in small field dosimetry.

60 APPLIED LIFE SCIENCES↗

WE-C-TOUR-T-01: Microdosimeters for Therapy

Tour Leader: Indra Das, NYU Langone Medical Center, New York, NY Tour Guides: Hsui Ai, Indiana University School of Medicine, Indianapolis, IN Paulina Galvis, NYU Langone Medical Center, New York, NY Olga Volotoskova, NYU Langone Medical Center, New York, NY Participating Vendors: IBA PTW – New York RTI Electronics, Inc. Standard Imaging, Inc. Sun Nuclear Corporation Small fields are increasing used in specialized radiation treatments such as Gammaknife, Cyberknife, Tomotherapy, IMRT, VMAT, SRS and SBRT. Due to small field size electron transport creates lateral electronic disequilibrium and thus dosimetry could be very difficult. Microdetectors are used for small field dosimetry which will be discussed in preface of this tour as below: Understanding small field e.g. meaning and definition of small field IAEA definition and approach Characteristics of microdetectors in terms of perturbation, recombination, correction Suitability of microdetectors in small field dosimetry.

60 APPLIED LIFE SCIENCES↗

WE-AB-207A-07: A Planning CT-Guided Scatter Artifact Correction Method for CBCT Images

Purpose: Cone beam computed tomography (CBCT) imaging is on increasing demand for high-performance image-guided radiotherapy such as online tumor delineation and dose calculation. However, the current CBCT imaging has severe scatter artifacts and its current clinical application is therefore limited to patient setup based mainly on the bony structures. This study’s purpose is to develop a CBCT artifact correction method. Methods: The proposed scatter correction method utilizes the planning CT to improve CBCT image quality. First, an image registration is used to match the planning CT with the CBCT to reduce the geometry difference between the two images. Then, the planning CT-based prior information is entered into the Bayesian deconvolution framework to iteratively perform a scatter artifact correction for the CBCT mages. This technique was evaluated using Catphan phantoms with multiple inserts. Contrast-to-noise ratios (CNR) and signal-to-noise ratios (SNR), and the image spatial nonuniformity (ISN) in selected volume of interests (VOIs) were calculated to assess the proposed correction method. Results: Post scatter correction, the CNR increased by a factor of 1.96, 3.22, 3.20, 3.46, 3.44, 1.97 and 1.65, and the SNR increased by a factor 1.05, 2.09, 1.71, 3.95, 2.52, 1.54 and 1.84 for the Air, PMP, LDPE, Polystryrene, Acrylic, Delrin and Teflon inserts, respectively. The ISN decreased from 21.1% to 4.7% in the corrected images. All values of CNR, SNR and ISN in the corrected CBCT image were much closer to those in the planning CT images. The results demonstrated that the proposed method reduces the relevant artifacts and recovers CT numbers. Conclusion: We have developed a novel CBCT artifact correction method based on CT image, and demonstrated that the proposed CT-guided correction method could significantly reduce scatter artifacts and improve the image quality. This method has great potential to correct CBCT images allowing its use in adaptive radiotherapy.

60 APPLIED LIFE SCIENCES↗