Dual Readout in Homogenous Inorganic Scintillators for Precision Calorimeters

Homogeneous inorganic scintillator-based calorimeters are the gold standard for electromagnetic energy resolution, but often degrade the hadronic energy resolution achievable at colliders. By incorporating the dual readout technique, we seek to improve the hadronic energy resolution of these calorimeters through the measurement and separation of the scintillation and Cherenkov light in hadronic showers. In April 2024, CalVision performed single-crystal tests using the electron test beam at DESY. Using a single delay line technique for waveform analysis, sufficient cerenkov light can be extracted to fully capitalize on the dual readout technique. This talk will present the results of PWO, BGO, BSO, PbF2, and two novel scintillating glasses.

Anderson, Thomas [Virginia U.]↗

Detector architecture and data flow of the CMS HGCAL Phase-2 Endcap Calorimeter Upgrade

The CMS High Granularity Calorimeter (HGCAL) is the Phase-2 endcap calorimeter upgrade for the High-Luminosity Large Hadron Collider, designed to provide precise spatial, energy, and timing measurements in a high-radiation, high-pileup environment. This work presents an overview of the HGCAL assembly process, detector architecture, and end-to-end data flow. The data flow goes from signal generation in silicon sensors and scintillator tiles through front-end electronics, optical transmission, and back-end data acquisition. The study highlights how the integrated detector, electronics, and readout systems enable efficient event reconstruction and support the physics objectives of the HL-LHC.

Osei Boakye, Prince [Grambling State U.]↗

Assembly and Testing of Scintillator Tile Modules for the CMS High-Granularity Calorimeter Upgrade

The High-Granularity Calorimeter (HGCAL), part of the upgrade to the Compact Muon Solenoid (CMS) experiment, employs silicon and scintillator tile modules in the endcaps to maintain detector performance during the High-Luminosity Large Hadron Collider (HL-LHC) era, scheduled to operate from 2030 to 2040. The upgraded calorimeter will provide highly segmented three-dimensional imaging, energy measurements, and precise timing for particle shower reconstruction. Approximately half of the HGCal plastic scintillator tile modules (1,834 total) will be assembled at Fermilab using an automated pick-and-place (PnP) machine. Following assembly, each tile module undergoes quality control (QC) procedures such as electrical validation, thermal testing, and physics validation using cosmic rays. This poster/talk presents the QC procedures and results from the tile module production in 2026, demonstrating the performance and quality of the assembled tile modules.

Bazimya, Jean Luc [Grambling State U.]↗

The Mu2e Calorimeter

The EM CsI crystals and SiPM readout calorimeter of the Mu2e experiment is fully assembled, with all components completed and tested; the mechanical structure is fully built, with a complete integration and test of all the analog sensors and electronics. The digital electronics is being produced and installed. We summarise the Calorimeter characteristics and the assembly status, as well as the move, installation and commissioning plans of the final disks in the Mu2e hall.

Borrel, L. [Caltech]↗

Performance of the AstroPix Prototype Module for the Barrel Imaging Calorimeter at the ePIC Detector and in Space-Based Payloads

AstroPix is a high-voltage CMOS (HV-CMOS) monolithic active pixel sensor originally developed to enable precision gamma-ray imaging and spectroscopy in the medium-energy regime (~100 keV–100 MeV) based on the groundwork laid by ATLASpix and MuPix. It features a 500 μm pixel pitch, in-pixel amplification and digitization, and low power consumption (~3-4 mW/cm2), making it scalable for large-area, multilayer telescope detector planes. The detectors have a designed dynamic range of 25 keV to 700 keV. With these features, AstroPix meets the requirements of future space-based high-energy telescopes and the imaging layers of the Barrel Imaging Calorimeter (BIC) in the Electron-Proton/Ion Collider (ePIC) detector at the future Electron-Ion Collider (EIC). For the space-based payload, AstroPix is being integrated into sounding rocket and balloon payloads to demonstrate the technical readiness of the devices. For BIC, AstroPix-based imaging layers interleaved within the lead/scintillating-fiber (Pb/SciFi) sampling calorimeter provide granular shower imaging, enabling key performance features such as electron/pion or gamma/neutral pion separation. As part of the ongoing detector R&D efforts, we have been testing various AstroPix_v3 configurations: the single chip, a quad-chip assembly, a three-layer stack of quad chips, and a 9-chip module that represents the smallest prototype unit of the BIC imaging layer. This presentation will highlight recent performance test results from these AstroPix detector configurations.

Kim, Bobae (ORCID:0000000295396815)↗

ADRIANO2 Calorimeter performance from 2022 Prototypes

A novel high-granularity dual-readout calorimetric technique was developed as part of the T1604 collaboration research program. The building block of ADRIANO2 Calorimeter consists of a pair of optically isolated, small sized tiles made of scintillating plastic and lead glass. The two components of the dual-readout energy compensation technique. Furthermore,Cˇerenkovlightfromtheleadglassareexploitedtoforhighresolutiontimingmeasurements,whilehigh granularity from scintillating plastic can be used to probe the spatial component of the particle shower. This setup works for excellent energy resolution and particle identification for REDTOP as it is crucial for a calorimeter to detect and identify the decay products of eta/eta-prime mesons. Measurements were collected on several ADRIANO2 prototypes between February to December 2022 to evaluate the detector performance. The key metrics extracted from the analyses are presented in this paper are the efficiencies and light-yi eld for various tile configurations. The measured values will be used as input parameters for improved REDTOP Montecarlo simulation.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Enhancing ICARUS and REDTOP Software and Hardware: Event Generator Interface Development and Calorimeter Tile Prototype

ICARUS (Imaging Cosmic And Rare Underground Signals) is a liquid argon time projection chamber (LArTPC) detector that pursues the sterile neutrino, which relies on accurate simulations of neutrino-argon interactions. REDTOP (Rare Eta Decays To Observe new Physics) is a proposed low-energy, high-intensity meson factory designed to explore rare $\eta$/$\eta'$ meson decays and probe physics beyond the Standard Model. As a next-generation experiment, this requires both accurate simulations and innovative detector technologies. This project contributes to both ICARUS, from a simulation perspective, and REDTOP, from both a simulation and detection perspective, through the event generation of lepton-nucleon interactions and the physical enhancement of the calorimeter technology within the REDTOP detector. We developed an interface between ACHILLES (A CHIcago Land Lepton Event Simulator), a theory-driven lepton-level event generator, and GENIE, a robust event generator framework used for neutrino physics. By incorporating the precise theoretical cross-section calculations of ACHILLES into the experimental realism of GENIE, the interface allows for improved accuracy of neutrino-nucleon simulations, which can be adapted for the proton beam specifications of the REDTOP meson factory as well as for the ICARUS experiment. In parallel, we developed an improved prototype for the ADRIANO2 (A Dual Readout Integrally Active Non-segmented Option) dual-readout calorimeter tiles for the REDTOP detector. To improve the efficiency of the lead-glass tiles trapping Cherenkov light for energy reconstruction and particle identification, we optimized the application of a highly reflective coating. Through viscosity and thickness control, masking, and a custom spray technique, we refined the coating process to reduce surface defects and improve light yield. Together, these efforts strengthen the ICARUS neutrino program and REDTOP's capability of detecting rare decay events.

Visser, Erin [Michigan State U.] (ORCID:0009000184↗

CaloTrilogy: Toward a Breakthrough in One-Step, End-to-End, Physics-Guided Shower Generation for Modern Calorimeters

High-precision calorimeter simulation at current and future colliders imposes rapidly growing computational demands, motivating the development of machine-learning surrogates for traditional Monte Carlo tools such as Geant4. Flow matching and diffusion-based generative models have become leading approaches for high-dimensional fast simulation because of their sample quality, but typically require ${\cal O}(100)$ function evaluations at inference and often rely on auxiliary networks to constrain global observables, compromising streamlined end-to-end generation. We introduce a unified framework that improves the balance between speed, shower quality, and physics fidelity. The method combines: (i) an average velocity field integrator that enables sampling in one or a few evaluations; (ii) a learned generative prior in shower space, constructed from data rather than random noise; and (iii) physics-guided loss terms that impose inductive biases on key observables during training. These elements are training time regularizers, preserving end-to-end inference with no additional cost. With only one or a few evaluation steps, the model achieves shower quality competitive with state-of-the-art flow and diffusion approaches, tested on several public high granularity calorimeter datasets. The results demonstrate inter-layer shower structure consistent with the underlying physics, providing a strong candidate for future fast simulation workflows.

Jiang, Cheng [Edinburgh U.]↗

A few-degree calorimeter for the future electron-ion collider

In this study, measuring the region 0.1 < Q 2 < 1.0 GeV 2 is essential to support searches for gluon saturation at the future Electron-Ion Collider. Recent studies have revealed that covering this region at the highest beam energies is not feasible with current detector designs, resulting in the so-called Q 2 gap. In this work, we present a design for the Few-Degree Calorimeter (FDC), which addresses this issue. The FDC uses SiPM-on-tile technology with tungsten absorber and covers the range of -4.6 < η < -3.6. It offers fine transverse and longitudinal granularity, along with excellent time resolution, enabling standalone electron tagging. Our design represents the first concrete solution to bridge the Q 2 gap at the EIC.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Timing Performance of the CMS High Granularity Calorimeter Prototype

This paper describes the experience with the calibration,reconstruction and evaluation of the timing capabilities of the CMSHGCAL prototype in the beam tests in 2018. The calibrationprocedure includes multiple steps and corrections ranging from tensof nanoseconds to a few hundred picoseconds. The timing performanceis studied using signals from positron beam particles with energiesbetween 20 GeV and 300 GeV. The performance is studied as afunction of particle energy against an external timing reference aswell as standalone by comparing the two different halves of theprototype. The timing resolution is found to be 60 ps forsingle-channel measurements and better than 20 ps for full showersat the highest energies, setting excellent perspectives for theHGCAL calorimeter performance at the HL-LHC.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

The effect of radiation damage on the light yield and uniformity of candidate plastic scintillator tiles for the CMS hadron calorimeter upgrade

A study has been performed to understand the effects of radiation damage on various plastic scintillator tiles considered for a possible upgrade of the hadron calorimeter of the CMS detector. Measurements were made with unirradiated tiles and with tiles that had been irradiated in the CMS collision hall to a dose of 44 kGy. Results are presented for the tiles of different shapes in terms of the energy spectrum, efficiency as a function of the position at which each tile was hit, as well as light yield. All the tiles showed a light reduction of up to about 50%. The tiles with the shape currently used in the CMS detector did not see increased non-uniformity of light collection, while a significant disuniformity was observed for the tiles considered as alternatives.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

The MUSE beamline calorimeter

The MUon Scattering Experiment (MUSE) was motivated by the proton radius puzzle arising from the discrepancy between muonic hydrogen spectroscopy and electron–proton measurements. The MUSE physics goals also include testing lepton universality, precisely measuring two-photon exchange contribution, and testing radiative corrections. MUSE addresses these physics goals through simultaneous measurement of high precision cross sections for electron–proton and muon–proton scattering using a mixed-species beam. The experiment will run at both positive and negative beam polarities. Measuring precise cross sections requires understanding both the incident beam energy and the radiative corrections. For this purpose, a lead-glass calorimeter was installed at the end of the beam line in the MUSE detector system. Here, in this article, we discuss the detector specifications, calibration and performance. We demonstrate that the detector performance is well reproduced by simulation, and meets experimental requirements.

Calorimeter↗

Upgrades of the ATLAS zero degree calorimeter system for Run 3 at the Large Hadron Collider

Experimental studies of ultra-relativistic heavy ion collisions at the Large Hadron Collider (LHC) depend crucially on Zero Degree Calorimeters (ZDCs) that measure neutrons produced at near-beam rapidity in nucleus-nucleus collisions. In hadronic nuclear collisions these neutrons are mainly spectator neutrons, those that do not scatter from opposing nucleons during the collision. As a result, the ZDCs provide a vital probe of heavy ion collision geometry. The ZDCs are also essential in the study of ultra-peripheral collisions that are initiated by photons associated with the electric fields of one or both nuclei. Coherent photon emission typically leaves the photon emitter intact, making the observation of no ZDC signal, on one or both sides, a tag of such processes. The ATLAS ZDCs, built prior to Run 1, were substantially upgraded for LHC Run 3. The primary upgrades included replacement of the quartz Cherenkov radiator with H_2-doped fused silica rods; installation of fast air-core signal cables between the ZDC and the ATLAS USA15 cavern; a new LED-based calibration system; and new electronics implemented for readout and fully-digital triggering. The ZDCs were also augmented with new “Reaction Plane Detectors” (RPDs) designed to measure the transverse centroid of multi-neutron showers to allow event-by-event reconstruction of the directed-flow plane in nuclear collisions. The Run 3 ZDC detectors, including the RPDs, are described in detail with emphasis on aspects that are new for Run 3.

43 PARTICLE ACCELERATORS↗

FCC feasibility studies: Impact of tracker- and calorimeter-detector performance on jet flavor identification and Higgs physics analyses

The ambitious physics program planned for the Future Circular Collider electron-positron phase imposes stringent constraints on detector performance. This study systematically investigates how different detector configurations impact jet flavor identification and their effects on high-profile physics analyses. Using Higgs boson coupling measurements and searches for invisible Higgs decays as benchmarks, we evaluate the sensitivity of these analyses to variations in tracker and calorimeter detector properties. We examine modifications to single-point resolution, material budget, silicon layer placement, and particle identification capabilities, quantifying their effects on flavor-tagging performance. Additionally, we present the first comprehensive study of Higgs-to-invisible decay detection using full detector simulation, providing insights for optimizing detector designs at lepton colliders.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Core line spread function calibration of the X-ray Imaging and Spectroscopy Mission Resolve X-ray calorimeter spectrometer

The Resolve X-ray imaging spectrometer onboard the X-ray Imaging and Spectroscopy Mission consists of a 36 pixel array of high-resolution X-ray calorimeters each with ∼ 5 eV full-width-at-half-maximum (FWHM) spectral resolution in the 0.3 to 12 keV band. The response to monochromatic X-rays (line spread function, LSF) is composed of a narrow Gaussian core and weak extended components caused by energy loss during thermalization. We report on the characterization of the Gaussian core LSF in an extensive ground calibration campaign. We also discuss the characterization of on-orbit resolution, which shows slightly higher FWHM than that obtained on the ground.

Astronomy and AstroPhysics↗

Precision calibration of calorimeter signals in the ATLAS experiment using an uncertainty-aware neural network

The ATLAS experiment at the Large Hadron Collider explores the use of modern neural networks for a multi-dimensional calibration of its calorimeter signal defined by clusters of topologically connected cells (topo-clusters). The Bayesian neural network (BNN) approach not only yields a continuous and smooth calibration function that improves performance relative to the standard calibration but also provides uncertainties on the calibrated energies for each topo-cluster. The results obtained by using a trained BNN are compared to the standard local hadronic calibration and to a calibration provided by training a deep neural network. The uncertainties predicted by the BNN are interpreted in the context of a fractional contribution to the systematic uncertainties of the trained calibration. They are also compared to uncertainty predictions obtained from an alternative estimator employing repulsive ensembles.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

A Review of the Multiple-Readout Concept and Its Application in an Integrally Active Calorimeter

A comprehensive multi-jet physics program is anticipated for experiments at future colliders. Key physics processes necessitate detectors that can distinguish signals from W and Z bosons and the Higgs boson. Typical examples include channels with or pairs and processes involving new physics in those cases where neutral particles must be disentangled from charged ones due to the presence of W or Z bosons in their final states. Such a physics program demands calorimetric energy resolution at or beyond the limits of traditional calorimetric techniques. Multiple-readout calorimetry, which aims to reduce fluctuations in energy measurements of hadronic showers, is a promising approach. The first part of this article reviews dual- and triple-readout calorimetry within a mathematical framework describing the underlying compensating mechanism. The second part proposes a potential implementation using an integrally active and total absorption detector. This model serves as the basis for several Monte Carlo studies, illustrating how the response of a multiple-readout calorimeter depends on construction parameters. Among the layouts considered, one configuration operating in triple-readout mode shows the potential to achieve an energy resolution approaching .

47 OTHER INSTRUMENTATION↗

Sensitivity of an early dark matter search using the electromagnetic calorimeter as a target for the Light Dark Matter eXperiment

The Light Dark Matter eXperiment (LDMX) is proposed to employ a thin tungsten target and a multi-GeV electron beam to carry out a missing momentum search for the production of dark matter candidate particles. We study the sensitivity for a complementary missing-energy-based search using the LDMX Electromagnetic Calorimeter as an active target with a focus on early running. In this context, we construct an event selection from a limited set of variables that projects sensitivity into previously-unexplored regions of light dark matter phase space — down to an effective dark photon interaction strength y of approximately 2 × 10 −13 (5 × 10 −12 ) for a 1 MeV (10 MeV) dark matter candidate mass.