At least 55 records · Page 3

Gender and Decompression Sickness: A Critical Review and Analysis

The author addressed the following questions: are women at greater risk of decompression sickness and venous gas emboli at certain times in their reproductive cycle, is risk modified by the use of birth control pills (BCP), and is there a difference in overall risk between men and women under the same decompression dose? The summary considers information from the few abstracts and reports that were available. Except for the observation of more Type II DCS in women, particularly in women who fly after diving, there was no compelling evidence of a difference in DCS risk between men and women SCUBA divers. Many women that presented with DCS symptoms seemed to be in or near menses, with statistically fewer cases reported as time increased from menses. There was no compelling evidence that the use of BCP in SCUBA divers increases the risk of DCS. There were insufficient data about VGE from SCUBA diving to make any conclusion about the incidence of VGE and gender. In contrast, there were ample data about VGE from research in altitude chambers. Women produced less VGE and less Grade IV VGE compared to men under the same decompression dose, certainly when resting oxygen prebreathe (PB) was performed prior to ascent to altitude. Dual-cycle ergometry exercise during PB tends to reduce the differences in VGE between men and women. There was no compelling evidence that the risk of altitude DCS was different between men and women. However, a large number of DCS cases were associated with menses, and the use of BCP did seem to put women at a slightly greater risk than those that did not use BCP. There were substantial observations that women comprised a larger number of difficult cases that required complicated medical management.

Source record↗

Systematic benchmarking demonstrates large language models have not reached the diagnostic accuracy of traditional rare-disease decision support tools

Large language models (LLMs) show promise in supporting differential diagnosis, but their performance is challenging to evaluate due to the unstructured nature of their responses, and their accuracy compared to existing diagnostic tools is not well characterized. To assess the current capabilities of LLMs to diagnose genetic diseases, we benchmarked these models on 5213 previously published case reports using the Phenopacket Schema, the Human Phenotype Ontology and Mondo disease ontology. Prompts generated from each phenopacket were sent to seven LLMs, including four generalist models and three LLMs specialized for medical applications. The same phenopackets were used as input to a widely used diagnostic tool, Exomiser, in phenotype-only mode. The best LLM ranked the correct diagnosis first in 23.6% of cases, whereas Exomiser did so in 35.5% of cases. While the performance of LLMs for supporting differential diagnosis has been improving, it has not reached the level of commonly used traditional bioinformatics tools. Future research is needed to determine the best approach to incorporate LLMs into diagnostic pipelines.

Reese, Justin T. [Lawrence Berkeley National Labor↗

An Analytical Study of Dilution Jet Mixing in a Cylindrical Duct

The mixing performance in a mixing section of a rich burn/quick mix/lean burn (RQL) combustor was calculated using a 3-D numerical model in a non-reacting environment. The numerically calculated results were compared with the measured data reported by Hatch, Sowa, Samuelsen, and Holdeman, 1992. The numerical 3-D temperature fields qualitatively agree with the experimental data. Also, the development of the mixing flow and temperature non-uniformity trends throughout the mixing section for the numerically calculated results quantitatively agree with the measured data. The numerical model predicts less mixing and enhances the temperature gradients as compared to the measured data for the cases reported by Hatch et al. (1992) which include circular and slot orifice shapes (with different slant angles and aspect ratios). The predicted and measured results generally agree in the selection of the slanted slot orifice configuration yielding the best overall mixing performance (based on temperature uniformity) of all the configurations analyzed.

Oechsle, V. L.↗

An analytical study of dilution jet mixing in a cylindrical duct

The mixing performance in a mixing section of a rich burn/quick mix/lean burn (RQL) combustor was calculated using a 3-D numerical model in a non-reacting environment. The numerically calculated results were compared with the measured data reported by Hatch, Sowa, Samuelsen, and Holdeman, 1992. The numerical 3-D temperature fields qualitatively agree with the experimental data. Also, the development of the mixing flow and temperature non-uniformity trends throughout the mixing section for the numerically calculated results quantitatively agree with the measured data. The numerical model predicts less mixing and enhances the temperature gradients as compared to the measured data for the cases reported by Hatch et al. (1992) which include circular and slot orifice shapes (with different slant angles and aspect ratios). The predicted and measured results generally agree in the selection of the slanted slot orifice configuration yielding the best overall mixing performance (based on temperature uniformity) of all the configurations analyzed.

Oechsle, V. L.↗

Parameter Estimation for Compact Binary Coalescence Signals with the First Generation Gravitational-Wave Detector Network

Compact binary systems with neutron stars or black holes are one of the most promising sources for ground-based gravitational-wave detectors. Gravitational radiation encodes rich information about source physics; thus parameter estimation and model selection are crucial analysis steps for any detection candidate events. Detailed models of the anticipated waveforms enable inference on several parameters, such as component masses, spins, sky location and distance, that are essential for new astrophysical studies of these sources. However, accurate measurements of these parameters and discrimination of models describing the underlying physics are complicated by artifacts in the data, uncertainties in the waveform models and in the calibration of the detectors. Here we report such measurements on a selection of simulated signals added either in hardware or software to the data collected by the two LIGO instruments and the Virgo detector during their most recent joint science run, including a blind injection where the signal was not initially revealed to the collaboration. We exemplify the ability to extract information about the source physics on signals that cover the neutron-star and black-hole binary parameter space over the component mass range 1M25M and the full range of spin parameters. The cases reported in this study provide a snapshot of the status of parameter estimation in preparation for the operation of advanced detectors.

Aasi, J.↗

Review of the Natural History of Renal Stones in U.S. Astronauts

BACKGROUND: The formation of renal stones in astronauts may pose a considerable threat to crew health and to the completion of mission objectives. Although a history of prior renal stones is an exclusion criterion for initial selection, there have been reported cases of renal stones that have developed after selection. This led to the establishment, nine years ago, of a standardized protocol to screen for the development of renal stones pre-and post-spaceflight in all active astronauts. OVERVIEW: Literature regarding stone makeup, size, location, time to passage, and outcomes were reviewed, as well as incidence of renal stones in astronaut analog populations such as military pilots and the general population. The Lifetime Surveillance of Astronaut Health (LSAH) database was queried and as of 2015 there have been 22 crew members who have reported 36 renal stone events from a population of 357 astronauts, with an incidence of 0.32 events per year. This compares favorably to the incidence of 0.37 to 0.46events per year in commercial pilots. DISCUSSION: The physiologic changes associated with spaceflight have been thought to present an increased risk for the development of stones, including hypercalciuria, decreased urine pH, and reduced urine volume. NASA’s screening program, based on a rigorous ultrasound method, has now provided nine years of clinical data used to reduce the risk of flying an astronaut with a renal stone that could threaten health and mission objectives. This work and data from the ultrasound screening program was used to update the clinical practice guideline for renal stone surveillance and treatment, and other NASA documents and programs that track this risk.

C McNerlin↗

Challenges of COVID-19 Case Forecasting in the US, 2020–2021

During the COVID-19 pandemic, forecasting COVID-19 trends to support planning and response was a priority for scientists and decision makers alike. In the United States, COVID-19 forecasting was coordinated by a large group of universities, companies, and government entities led by the Centers for Disease Control and Prevention and the US COVID-19 Forecast Hub ( https://covid19forecasthub.org ). We evaluated approximately 9.7 million forecasts of weekly state-level COVID-19 cases for predictions 1–4 weeks into the future submitted by 24 teams from August 2020 to December 2021. We assessed coverage of central prediction intervals and weighted interval scores (WIS), adjusting for missing forecasts relative to a baseline forecast, and used a Gaussian generalized estimating equation (GEE) model to evaluate differences in skill across epidemic phases that were defined by the effective reproduction number. Overall, we found high variation in skill across individual models, with ensemble-based forecasts outperforming other approaches. Forecast skill relative to the baseline was generally higher for larger jurisdictions (e.g., states compared to counties). Over time, forecasts generally performed worst in periods of rapid changes in reported cases (either in increasing or decreasing epidemic phases) with 95% prediction interval coverage dropping below 50% during the growth phases of the winter 2020, Delta, and Omicron waves. Ideally, case forecasts could serve as a leading indicator of changes in transmission dynamics. However, while most COVID-19 case forecasts outperformed a naïve baseline model, even the most accurate case forecasts were unreliable in key phases. Further research could improve forecasts of leading indicators, like COVID-19 cases, by leveraging additional real-time data, addressing performance across phases, improving the characterization of forecast confidence, and ensuring that forecasts were coherent across spatial scales. In the meantime, it is critical for forecast users to appreciate current limitations and use a broad set of indicators to inform pandemic-related decision making.

59 BASIC BIOLOGICAL SCIENCES↗

A comparison of linear acoustic theory with experimental noise data for a small-scale hovering rotor

Linear acoustic calculations based on full aerodynamic data as input are presented and compared with measured cases reported by Boxwell et al. (1978). The full aerodynamic data are obtained using three programs giving radial loading, chordwise loading, and chordwise position of transition. It is shown that in the theoretical results the most significant noise source mechanism is due to blade thickness. Thus the conclusions of Boxwell et al. as to the importance of nonlinearities around the blades are upheld. These conclusions concern the width, shape and the level of the acoustic pressure calculated from linear acoustic theory. Some of the approximations involved in the application of acoustic analogy using quadrupole sources are discussed. It is necessary that the near- and far-field problems of rotating blades be treated together as shown for the case of an oscillating sphere.

Farassat, F.↗

Statistical Analysis of CFD Solutions from 2nd Drag Prediction Workshop

In June 2001, the first AIAA Drag Prediction Workshop was held to evaluate results obtained from extensive N-Version testing of a series of RANS CFD codes. The geometry used for the computations was the DLR-F4 wing-body combination which resembles a medium-range subsonic transport. The cases reported include the design cruise point, drag polars at eight Mach numbers, and drag rise at three values of lift. Although comparisons of the code-to-code medians with available experimental data were similar to those obtained in previous studies, the code-to-code scatter was more than an order-of-magnitude larger than expected and far larger than desired for design and for experimental validation. The second Drag Prediction Workshop was held in June 2003 with emphasis on the determination of installed pylon-nacelle drag increments and on grid refinement studies. The geometry used was the DLR-F6 wing-body-pylon-nacelle combination for which the design cruise point and the cases run were similar to the first workshop except for additional runs on coarse and fine grids to complement the runs on medium grids. The code-to-code scatter was significantly reduced for the wing-body configuration compared to the first workshop, although still much larger than desired. However, the grid refinement studies showed no sign$cant improvement in code-to-code scatter with increasing grid refinement.

Hemsch, M. J.↗

Enhancing the Range and Reliability of the Spacer Layer Imaging Method

The spacer layer imaging method (SLIM) is widely used to measure the thickness of additive and lubricant films, in lubricant development and evaluation, and for fundamental research into elastohydrodynamic lubrication and tribofilm formation mechanisms. The film thickness measurement, as implemented on several popular tribometers, provides powerful, non-destructive in-situ mapping of film topography with nanometre-scale height sensitivity. However, the results can be highly sensitive to experimental procedure, machine condition, and image analysis, in some cases reporting unphysical film thickness trends. The prevailing image analysis techniques make it challenging to interrogate these errors, often hiding their multivariate nonlinear behaviour from the user by spatial averaging. Herein, several common ‘silent errors’ in the SLIM measurement, including colour matching to incorrect fringe orders, and colour drift due to the optical properties of the system or film itself, are discussed, with examples. A robust suite of novel a priori and a posteriori methods to address these issues, and to improve the accuracy and reliability of the measurement, are also presented, including a novel, computationally inexpensive circle-finding algorithm for automated image processing. In combination, these methods allow reliable mapping of films up to at least 800 nm in thickness, representing a significant milestone for the utility of SLIM applied to elastohydrodynamic contact.

EHL film geometry↗

Orbital selective band re-normalization induced Lifshitz transition in TiSe 2

A Lifshitz transition is a sudden change in Fermi surface topology, often linked to quantum phenomena, with major impact on transport and sometimes superconductivity. Here we demonstrate a Lifshitz transition in TiSe 2 using micro–angle-resolved photoemission spectroscopy. At low temperatures an electron pocket appears at the Brillouin-zone center, whereas at higher temperatures spectral weight from a hole-like valence band dominates the Fermi level. Unlike previously reported cases typically driven by rigid band shifts, in TiSe 2 an orbital-selective strong band renormalization induces the crossover near 160 K. This mechanism naturally explains the longstanding resistivity anomaly of TiSe 2 , which peaks around 160 K. Our results clarify its puzzling transport behavior and open avenues to investigate how periodic lattice distortions interact with strong electronic correlations.

36 MATERIALS SCIENCE↗

Rapid, antibiotic incubation-free determination of tuberculosis drug resistance using machine learning and Raman spectroscopy

Tuberculosis (TB) is the world’s deadliest infectious disease, with over 1.5 million deaths and 10 million new cases reported anually. The causative organism Mycobacterium tuberculosis (Mtb) can take nearly 40 d to culture, a required step to determine the pathogen’s antibiotic susceptibility. Both rapid identification and rapid antibiotic susceptibility testing of Mtb are essential for effective patient treatment and combating antimicrobial resistance. Here, we demonstrate a rapid, culture-free, and antibiotic incubation-free drug susceptibility test for TB using Raman spectroscopy and machine learning. We collect few-to-single-cell Raman spectra from over 25,000 cells of the Mtb complex strain Bacillus Calmette-Guérin (BCG) resistant to one of the four mainstay anti-TB drugs, isoniazid, rifampicin, moxifloxacin, and amikacin, as well as a pan-susceptible wildtype strain. By training a neural network on this data, we classify the antibiotic resistance profile of each strain, both on dried samples and on patient sputum samples. On dried samples, we achieve >98% resistant versus susceptible classification accuracy across all five BCG strains. In patient sputum samples, we achieve ~79% average classification accuracy. We develop a feature recognition algorithm in order to verify that our machine learning model is using biologically relevant spectral features to assess the resistance profiles of our mycobacterial strains. Finally, we demonstrate how this approach can be deployed in resource-limited settings by developing a low-cost, portable Raman microscope that costs <$5,000. We show how this instrument and our machine learning model enable combined microscopy and spectroscopy for accurate few-to-single-cell drug susceptibility testing of BCG.

60 APPLIED LIFE SCIENCES↗

Thermal Modeling and Limitations for Power Electronics Embedded in Medium-Voltage Cables

As next-generation energy technologies gain traction and power demand increases, the existing electrical infrastructure faces significant stress, prompting innovative solutions to enhance the grid's capacity and lifespan. This work explores the possibility of embedding medium-voltage (MV) power electronics directly inline with the cable, and the resulting thermal challenges. Since the majority of power distribution cables installed in the U.S. are passively cooled, the work focuses primarily on passive cooling, with an emphasis on the limitations of axial heat spreading within the cable. To date, literature on axial spreading of high incident heat loads on cables and cable environments is limited, typically reporting cases with <10 W of incident heat load. This work will explore the considerations, limits, and tradeoffs of cable-embedded heat loads significantly larger than the cable losses. Both external and internal effects are modeled analytically in nondimensional terms via a Biot number analysis, allowing fundamental limits and tradeoffs to be derived. The work culminates in the design and experimental validation of a cable-embedded thermal system capable of passively dissipating 300 W of heat from a coaxial SiC mosfet switch module over a length of 20 cm, thus validating the possibility of MV cable-embedded power electronics from a thermal standpoint.

24 POWER TRANSMISSION AND DISTRIBUTION↗

The polyuria of paroxysmal atrial tachycardia

Two patients with paroxysmal atrial fibrillation and an associated polyuria were studied to delineate the mechanism of the increase in urine flow. A striking saluresis was noted in both patients. The increased sodium excretion was probably due to decreased sodium reabsorption, perhaps at proximal tubular nephron sites. This inhibition of sodium reabsorption could explain both the saluresis and some part or all of the polyuria. Re-evaluation of earlier case reports reveals patterns of concomitant salt and water excretion consistent with this mechanism. The saluresis cannot be explained by the previously favored hypothesis of antidiuretic hormone inhibition.

Kinney, M. J.↗

Flight effects on exhaust noise for turbojet and turbofan engines - Comparison of experimental data with prediction

Recent experiments on the effects of flight on jet engine exhaust noise have produced apparently conflicting results. Some of these results do not agree with projections based on classical jet noise theories nor with experimental results from model jet simulated flight tests. It has been shown that in some of the cases reported, the proper corrections were not made to account for the distributed nature of the jet noise sources. It is shown herein that the remaining discrepancies can be reconciled by considering the combined effects of jet-mixing noise, internally-generated engine exhaust noise, and shock noise. This paper demonstrates that static and in-flight jet engine exhaust noise can be predicted with reasonable accuracy when the multiple-source nature of the problem is taken into account. Jet-mixing noise is predicted from an improved version of the NASA interim prediction method. Provisional methods of estimating internally-generated noise and shock noise flight effects are used, based partly on existing prediction methods and partly on recently reported engine data.

Stone, J. R.↗

The polarization of second harmonic plasma emission

It is shown that second-harmonic plasma emission is partially polarized in the sense of the ordinary mode of magnetoionic theory only when the Langmuir waves are confined to a small range of angles (less than 30 deg) to the magnetic-field lines. Consequently, Suzuki and Sheridan's (1977) observations of the polarization of harmonic Type III emission implies that (at least in the cases reported) the Langmuir waves must be nearly one-dimensional. For a nearly one-dimensional distribution, the degree of polarization and the frequency of observation should be related to the magnetic field. For the observed polarization of Type III bursts, the implied magnetic-field strengths are strong enough for induced scattering to cause the Langmuir waves to become nearly one-dimensional, which is consistent with the observed sense of polarization. In other applications of harmonic plasma emission where the Langmuir waves might be isotropic or in a loss-cone distribution, polarization in the sense of the extraordinary mode is predicted.

Melrose, D. B.↗

Removal of histological sections from glass for electron microscopy - Use of Quetol 651 resin and heat

A number of approaches have been used to separate stained conventional histological sections from glass slides in preparation for a study with the electron microscope. However, in each reported case some problems were encountered with respect to the separation process. The present investigation is concerned with the use of the epoxy resin Quetol 651 as an embedding medium for this procedure, taking into account the simple application of heat (62-64 C) for performing the separation step. After the tissue has been removed from the glass by the considered technique, it is thin sectioned, and stained with uranyl acetate-lead citrate.

Kraft, L. M.↗

Engineering correlations of variable-property effects on laminar forced convection mass transfer for dilute vapor species and small particles in air

A simple engineering correlation scheme is developed to predict the variable property effects on dilute species laminar forced convection mass transfer applicable to all vapor molecules or Brownian diffusing small particle, covering the surface to mainstream temperature ratio of 0.25 T sub W/T sub e 4. The accuracy of the correlation is checked against rigorous numerical forced convection laminar boundary layer calculations of flat plate and stagnation point flows of air containing trace species of Na, NaCl, NaOH, Na2SO4, K, KCl, KOH, or K2SO4 vapor species or their clusters. For the cases reported here the correlation had an average absolute error of only 1 percent (maximum 13 percent) as compared to an average absolute error of 18 percent (maximum 54 percent) one would have made by using the constant-property results.