Search NASA⌕ Search

SEARCH · Search NASA

Results for “Center”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 55 records · Page 3

District heating utilizing waste heat of a data center: High-temperature heat pumps

Data centers are energy-intensive facilities with substantial low-grade waste heat. High-temperature heat pumps can be critical in boosting the data center’s waste heat for district heating, improving the system-level energy efficiency of data centers, and reducing CO 2 emissions in district heating. This study built thermodynamic models to assess high-temperature heat pumps with six configurations using low global warming potential refrigerants to supply heat up to 120 °C. The heat pump configurations include single-stage or two-stage cycles with advanced components, such as internal heat exchanger, economizer, flash tank, or parallel compressor. The refrigerants include R1234ze(Z), R1233ed(E), R1224yd(Z), R600, and R600a, and R245fa is used as a reference. A case study was carried out to recover the waste heat from the Frontier high-performance computing data center and provide hot water for district heating at the US Department of Energy’s Oak Ridge National Laboratory campus. The optimized performance of high-temperature heat pumps is characterized with various effectiveness of internal heat exchangers, and the operating parameters of economizer or flash tank, as well as their combination. The results show that the configurations of two-stage cycles with internal heat exchanger + flash tank and internal heat exchanger + economizer/parallel-compressor provide the highest coefficient of performance under scenarios of the maximum allowable value and a fixed value (0.3) of the internal heat exchangers’ effectiveness, respectively. R1234ze(Z) and R600a are the most promising refrigerants, considering trade-offs between the coefficient of performance and the volumetric heating capacity. The single-stage cycle with internal heat exchanger + economizer/parallel-compressor using R1234ze(Z) is recommended for utilizing Fronter’s waste heat in district heating. A one mega-watt high-temperature heat pump will reduce 33,100–33,200 metric tons of CO2 emission annually, corresponding to 85.4 %–85.6 % of equivalent CO2 emissions from natural gas boilers. Here, this study provides good guidelines for designing and deploying high-temperature heat pumps to support sustainable data centers and decarbonize district heating in the US.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

High-efficiency, high-fidelity charge initialization of shallow nitrogen-vacancy centers in diamond

Nitrogen-vacancy (N-𝑉) centers in diamond exhibit long spin-coherence times, optical initialization, and optical-spin readout under ambient conditions, making them excellent quantum sensors. However, the conventional scheme for charge-state initialization based on off-resonant green excitation results in significant state-preparation errors, typically around 30%. One method for improving charge-state initialization fidelity is to use multicolor excitation, which has been demonstrated to achieve a near-unity preparation fidelity for bulk N-𝑉 centers by using a few milliseconds of near-infrared (NIR) (5-mW) and green (10-μ⁢W) excitation. The translation of such schemes to N-𝑉 centers near the diamond surface with higher-efficiency optical pumping would enable new applications in nanoscale sensing. Here, we demonstrate a protocol for efficient charge initialization of shallow N-𝑉 centers between 5 nm and 15 nm from the diamond surface. By carefully studying the charge dynamics of shallow N-𝑉 centers, we identify a region of parameter space that allows for near-unity (95%) charge initialization within 300 μ⁢s of NIR (905-nm, 1-mW) and green (520-nm, 10-μ⁢W) excitation. The time to 90% charge initialization can be as fast as 10 μ⁢s for 4 mW of NIR and 39 μ⁢W of green illumination. This fast, efficient charge initialization protocol will especially benefit nanoscale sensing applications in which state-preparation errors currently prohibit scaling, such as measuring higher-order multipoint correlators.

infrared techniques↗

Colorado State University Extension Industrial Assessment Center

Since its inception in 1984, the Colorado State University Industrial Assessment Center has performed industrial assessments at more than 720 manufacturing facilities in Colorado, Montana, Nebraska, Nevada, New Mexico, North Dakota, South Dakota, Utah, and Wyoming. From 2017 to 2019 there was a funding gap and the IAC shutdown. In 2020 through DOE extension funding the University relaunched the IAC as an extension center in order to provide assessments to underserved areas. Under this award, the CSU Industrial Assessment Center (IAC) was rebuilt with the help of student employees and the director. The CSU team experienced difficulty as the program was in the process of being restarted right as the 2020 pandemic hit. Nonetheless, the CSU IAC was instrumental in providing energy assessments to manufacturers in Colorado and Wyoming during the period of performance of 09/2019 – 12/2022. The Department of Energy's Industrial Assessment Centers (IACs) provide a valuable service to small and medium-sized manufacturers seeking to optimize their operations. These university-based centers offer no-cost, on-site assessments conducted by engineering faculty and students, analyzing energy consumption, production processes, and waste streams. They utilize advanced data acquisition systems to record operational data, and then use the data to create assessment recommendations. These recommendations form the foundation of the comprehensive energy report. The comprehensive report delivers actionable recommendations for enhancing energy efficiency, reducing waste, and reducing greenhouse gas emissions and improving productivity, often identifying significant cost savings. Furthermore, IACs facilitate access to implementation grants, enabling the businesses to readily adopt these improvements. This program not only strengthens individual businesses but also contributes to national goals of training the next generation of energy experts, as well as increasing industrial competitiveness and reduced environmental impact.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Electromagnetic Transient Modeling of Data Centers

This report serves as a user manual for the accompanying EMT model library developed by the National Laboratory of the Rockies (NLR) for various equipment in large data centers. The EMT model library enables detailed modeling of large data center loads for conducting grid stability studies. The EMT model library for data centers include detailed models of a 5.5 kW power supply unit (PSU), a 2.5 uninterruptible power supply (UPS), a 260 MW gas turbine-generator, a 500 kW motor load, and a 33 kW IT rack. These components represent all major equipment in data centers that need to be modeled for performing grid stability studies for data centers.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Atomic-scale imaging and charge state manipulation of NV centers by scanning tunneling microscopy

Nitrogen-vacancy (NV) centers in diamond are among the most promising solid-state qubit candidates, owing to their exceptionally long spin coherence times, efficient spin-photon coupling, room-temperature operation, and steadily advancing fabrication and integration techniques. Despite significant progress in the field, atomic-scale characterization and control of individual NV centers have remained elusive. In this work, we utilize a conductive graphene capping layer to enable direct imaging and manipulation of NV - defects via scanning tunneling microscopy (STM). By investigating over 40 individual NV - centers, we identify their spectroscopic signatures and spatial configurations. Our dI/dV conductance spectra reveal the ground state resonance approximately 300 meV below the Fermi level and density-of-states maps uncover a two-lobed wavefunction aligned along the [111] crystallographic direction. Remarkably, we demonstrate the ability to manipulate the charge state of the NV centers from NV - to NV 0 through STM tip-induced gating. This work represents a significant advance in the atomic-scale imaging, spectroscopic characterization, and charge-state manipulation of NV centers, potentially paving the way for future quantum device development.

Raghavan, Arjun [Univ. of Illinois at Urbana-Champ↗

Electric field sensitivity of molecular color centers

Molecular color centers with S=1 ground states are promising candidates for quantum sensing of electric fields. These molecules have an electronic structure similar to solid state color centers, but they allow for processing modalities that permit direct interfacing with an analyte. Currently, it is unknown how sensitive these molecules are to electric fields and what molecular properties affect their sensitivity. We perform density functional theory calculations to understand the impact of electric fields on the electronic structure of five nominally tetrahedral molecular color centers exhibiting variable transition metal chemistry and ligand densities. We then extract the Stark parameters from each of these molecules and compare them to molecular properties such as the dipole moment and inner shell stiffness and find that the dipole moment of the molecule largely governs sensitivity. We predict that polar heteroleptic molecules may have electric field sensitivities comparable to solid state color centers such as nitrogen-vacancy centers in diamond.

Physics↗

Laser-Induced Spectral Diffusion of T Centers in Silicon Nanophotonic Devices

Color centers in silicon are emerging as spin-photon interfaces operating at telecommunication wavelengths. The nanophotonic device integration of silicon color centers via ion implantation leads to significant optical-linewidth broadening, which makes indistinguishable photon generation challenging. Here, we study the optical spectral diffusion of T centers in a silicon photonic crystal cavity. We investigate the linewidth-broadening timescales and origins by measuring the temporal correlations of the resonance frequency under different conditions. Spectral hole-burning measurements reveal no spectral broadening at short timescales from 102 ns to 725 ns. We probe broadening at longer timescales using a check pulse to herald the T-center frequency and a probe pulse to measure the frequency after a wait time. The optical resonance frequency is stable up to 3 ms in the dark. Laser pulses below the silicon band gap applied during the wait time lead to linewidth broadening. Our observations establish laser-induced processes as the dominant spectral-diffusion mechanism for T centers in devices and inform materials and feedback strategies for indistinguishable photon generation.

Zhang, Xueyue↗

Multiplexed color centers in a silicon photonic cavity array

Entanglement distribution is central to the modular scaling of quantum processors and establishing quantum networks. Color centers with telecom-band transitions and long spin coherence times are suitable candidates for long-distance entanglement distribution. However, high-bandwidth memory-enhanced quantum communication is limited by high-yield, scalable creation of efficient spin-photon interfaces. Here, we develop a silicon photonics platform consisting of arrays of bus-coupled cavities. The coupling to a common bus waveguide enables simultaneous access to individually addressable cavity-enhanced T center arrays. We demonstrate frequency-multiplexed operation of two T centers in separate photonic crystal cavities. In addition, we investigate the cavity enhancement of a T center through hybridized modes formed between physically distant cavities. Our results show that bus-coupled arrays of cavity-enhanced color centers could enable efficient on-chip and long-distance entanglement distribution.

Komza, Lukasz↗

Community Input on the Need, Scope, and Development Roadmap of a Proposed National Virtual Biosecurity for Bioenergy Crops Center (NVBBCC)

Brookhaven National Laboratory (BNL) was awarded a pilot project in FY22 under the U.S. Department of Energy (DOE) Office of Science Biopreparedness Research Virtual Environment (BRaVE) initiative, to define research priorities, needs, and requirements for a national virtual center devoted to the biosecurity of bioenergy crops. The mission of the proposed center, referred to as the National Virtual Biosecurity for Bioenergy Crop Center (NVBBCC), would be to provide the scientific basis and tools to detect, characterize, model, and mitigate biothreats to bioenergy crops. This function will be essential to ensure the projected increased US reliance over the next few decades on key plant-based energy products, such as biojet fuel. The NVBBCC is envisioned as a distributed, virtual center with multiple national laboratories at its core to maximize the use of existing unique facilities and expertise across the DOE complex. A major goal of the pilot project was to develop a roadmap for establishing NVBBCC through a series of meetings to gather community input. A total of about 150 individuals, drawn from DOE laboratories, the USDA, academia, NIH, DHS and the private sector participated in six planning meetings held in FY23. Four of the meetings were focused on specific research topics (disease detection, dispersion and disease propagation, biomolecular characterization of plant-pathogen interaction, and mitigation strategies). These four meetings were followed by a meeting that focused on computational needs to support collaborative, data-intensive research within a distributed center as well as workforce development. A final meeting focused on establishing and maintaining preparedness within NVBBCC to respond to an emerging disease within bioenergy crops and how it would collaborate and coordinate with USDA and DHS.

09 BIOMASS FUELS↗

Towards Marine Carbon Dioxide Removal (mCDR) Centers of Excellence

A diverse portfolio of carbon dioxide removal (CDR) technologies will be essential to meeting climate goals while supporting sustainable development. In particular, marine carbon dioxide removal (mCDR) methods can help diversify the existing portfolio, which currently relies heavily on engineered direct air capture systems for large-scale atmospheric removals. To fulfill their potential in the CDR ecosystem, these early-stage mCDR technologies require additional research and development. Here, we propose regional mCDR Technology Centers of Excellence that will provide inventors and developers with access to right-scale facilities and engineering expertise that will meet their needs wherever they are on the journey from bench- to pilot-scale development. To support innovation across the technological readiness level spectrum, these Centers will provide collaborative access to ocean-based mCDR testing sites; other opportunities for partnering with multidisciplinary experts in technology development and commercialization; provide meaningful pathways for integrated engagement with local industrial and regulatory systems; and help in developing tailored, impactful community benefit models. Ideal sites are co-located in areas with a favorable natural environment for testing mCDR, well studied baselines, accessible infrastructure for multidisciplinary marine research, and technology commercialization support. As a case study, we offer the Pacific Northwest as particularly suitable for a regional mCDR Technology Center of Excellence given existing and potential growth of all the characteristics of ideal sites listed above, and which could especially benefit from the region’s growing marine climate technology sector. Last, we offer a brief whole-of-government perspective for supporting and regulating these Centers of Excellence, including identification of mCDR Science Centers of Excellence to ensure that the development of mCDR technologies dovetails with much-needed advancements in oceanographic observation and simulation infrastructure.

54 ENVIRONMENTAL SCIENCES↗

Data Center High-Temperature Liquid Cooling and Heat Reuse Techno-Economic Study: Preprint

Data centers are energy-intensive facilities with growing demands for efficiency and cost-effective operations. Smaller, more distributed edge inference data centers are expected to proliferate as AI applications require low latency closer to the user of AI tools, which presents a growing opportunity to explore the systems implications of liquid cooling on water and energy use. This study analyzes the implementation of high-temperature liquid cooling systems in a prototypical inference 1-MW data center and explores the potential for heat reuse across varying climates with a goal to optimize energy efficiency, reduce capital and operational costs, and identify opportunities for high-performance cooling and water use reduction infrastructure. This analysis evaluated configurations utilizing a peak day hourly sizing and systems performance spreadsheet to evaluate design and operational conditions from which component sizes, installed cost, operational cost, and performance metrics were determined for the Base case and the Elevated case. The techno-economic analysis included heat reuse applications across a range of heat recovery temperatures and heat rejection options. The analysis shows that high-temperature liquid cooling allows for improved energy efficiency, lower water consumption, and lower capital costs compared to traditional cooling approaches. Transitioning to elevated water inlet/outlet temperatures (50 degrees C/60 degrees C) eliminates the need for chillers, cooling towers, and heat recovery equipment in many scenarios across three distinct climate zones. This results in up to 75% capital cost savings for the cooling and heat recovery equipment, and with significantly reduced water consumption, especially in non-heat reuse applications. Heat generated from data centers can also be repurposed for space heating, domestic hot water, and other applications, and is most cost-effective when data center outlet temperatures exceed 55-60 degrees C.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Accelerating nuclear-integrated data center pursuits in the USA: SWOT analysis, power-thermal management strategies and demonstration plan

Here, this study explores the increasing interest in leveraging nuclear power to meet the escalating energy demands of data centers in the United States (U.S.) by focusing on key factors that contribute to accelerated deployment. The study highlights the importance of N+1/N+2 power supplies (where N is the required number of units), outlines research and innovations in nuclear-integrated data center thermal management and demonstration plan. It also provides updates about status and costing of various reactor system designs. A summarized strengths, weaknesses, opportunities, and threats (SWOT) analysis shows the potential options for grid connectivity, reactors, and site selection. Suitable site discussions consider land and water availability, grid access, and optical fiber connectivity, and the study presents graded prospects for Department of Energy (DOE) sites with a specific example. Community engagement and partnerships are emphasized, particularly the roles of local government, federal agencies, utilities, and data center industry partners, which are crucial for accelerating deployment, business outreach, and approvals. The study provides actionable insights for stakeholders to accelerate the deployment of nuclear-powered data centers.

21 - SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLAN↗

Sub-2 Kelvin Characterization of Nitrogen-Vacancy Centers in Silicon Carbide Nanopillars

The development of efficient quantum communication technologies depends on the innovation in multiple layers of its implementation, a challenge we address from the fundamental properties of the physical system at the nanoscale to the instrumentation level at the macroscale. We select a promising near-infrared quantum emitter, the nitrogen-vacancy (NV) center in 4H-SiC, and integrate it, at an ensemble level, with nanopillar structures that enhance photon collection efficiency into an objective lens. Moreover, changes in collection efficiency in pillars compared to bulk can serve as indicators of color center orientation in the lattice. To characterize NV center properties at the unprecedented sub-2 K temperatures, we incorporate compatible superconducting nanowire single photon detectors inside the chamber of an optical cryostat and create the ICECAP, the Integrated Cryogenic system for Emission, Collection And Photon detection. ICECAP measurements show no significant line-width broadening of NV ensemble emission and up to 14-fold enhancement in collected emission. With additional filtering, we measure emitter lifetimes of NV centers in a basal ( hk ) and axial ( kk ) orientation, unveiling their cryogenic values of 2.2 and 2.8 ns.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Why the electron chooses one of two symmetry-related paths in the type II bacterial photosynthetic reaction centers

A series of electron and proton transfer reactions are carried out in photosynthetic reaction centers that convert the energy of light into high energy reduced products and add to the proton gradient. All photosynthetic reaction centers (photosystems I, II, and different bacterial reaction centers (bRCs)) have their charge separating cofactors arranged with two, c 2 -symmetric paths from a primary donor to a terminal acceptor. In Type II reaction centers (PSII and bRCs), electrons utilize only one active branch. In bRCs the electron transfer occurs in the A branch from the excited state of the bacteriochlorophyll (BChl) dimer P 860 through BChl A , bacteriopheophytin A (BPh A ), to ubiquinone Q A , and then to the B-branch Q B . B-branch BChl B and BPh B do not participate. A similar path is found in PSII. These proteins challenge our understanding of how proteins can turn on or turn off the activity of bound ligands. The shift of the electrochemical midpoint potential (E m ) of each cofactor by the protein environment is calculated using continuum electrostatics within the Multi-Conformation Continuum Electrostatic (MCCE) program. In bRCs from Rhodobacter sphaeroides, the electrostatic potentials favor reduction of the active branch cofactors. The residues that contribute to a more positive potential on the A branch are identified. These are often distant from the cofactors. The large difference of the potential at the competing BChls may direct the electron transfer to the A branch. Residues TyrM210 and PheL181 are at symmetrical positions on the A and B branches, near P 860 , between BChl A and BChl B . Mutated bRCs, that swap the Tyr and Phe (YF mutant), have been shown to support some electron transfer to the B-branch cofactors. Here, the calculated E m s with the YF swap show more positive B-branch potentials, which help explain why there is now electron transfer along the B branch.

Bacterial Reaction Center↗

Stroboscopic x-ray diffraction microscopy of dynamic strain in diamond thin-film bulk acoustic resonators for quantum control of nitrogen-vacancy centers

Bulk-mode acoustic waves in a crystalline material exert lattice strain through the thickness of the sample, which couples to the spin Hamiltonian of defect-based qubits such as the nitrogen-vacancy (N-V) center defect in diamond. This mechanism has previously been harnessed for unconventional quantum spin control, spin decoherence protection, and quantum sensing. Bulk-mode acoustic wave devices are also important in the microelectronics industry as microwave filters. A key challenge in both applications is a lack of appropriate operando microscopy tools for quantifying and visualizing gigahertz-frequency dynamic strain. Here, in this work, we directly image acoustic strain within N-V center-coupled diamond thin-film bulk acoustic wave resonators using stroboscopic scanning hard x-ray diffraction microscopy at the Advanced Photon Source. The far-field scattering patterns of the nanofocused x-ray diffraction encode strain information entirely through the illuminated thickness of the resonator. These patterns have a real-space spatial variation that is consistent with the bulk strain’s expected modal distribution and a momentum-space angular variation from which the strain amplitude can be quantitatively deduced. We also perform optical measurements of strain-driven Rabi precession of of the N-V center spin ensemble, providing an additional quantitative measurement of the strain amplitude. As a result, we directly measure one of the six N-V spin-stress coupling parameters, 𝑏 =2.73⁢(2) MHz/GPa, by correlating these measurements at the same spatial position and applied microwave power. Our results demonstrate a unique technique for directly imaging ac lattice strain in micromechanical structures and provide a direct measurement of a fundamental constant for the N-V center defect spin Hamiltonian.

acoustic techniques↗

Vulcan Test Platform: Demonstrating the Data Center as a Flexible Grid Asset

Explosive data center demand is outpacing grid infrastructure development. AI workloads and hyperscale cloud growth are creating unprecedented power requirements, while traditional grid expansion faces multi-year development timelines, regulatory hurdles, and decarbonization challenges. Sidewalk Infrastructure Partners recognized this impending crisis years ago and founded Verrus to develop an innovative solution: data centers that function as grid assets rather than passive loads. The Verrus approach integrates proprietary grid-aware controls with battery energy storage systems (BESS) in a medium-voltage architecture that delivers three critical capabilities: Fast-responding demand flexibility that can service requests from the utility within 10 seconds, Uninterrupted transition to islanded operation during grid disturbances, Continuous uptime assurance while maintaining all customer service level commitments Through Verrus' strategic partnership with the National Renewable Energy Laboratory (NREL), we validated these capabilities on Vulcan, a 70 MW utility-scale test platform powered by NREL's ARIES Virtual Emulation Environment. This deployment-ready technology has successfully demonstrated that Verrus data centers can deliver meaningful grid services while maintaining mission-critical reliability. This technical report outlines the design, methodology, and results of this emulated deployment, demonstrating that data centers can play a pivotal role in enhancing grid flexibility and reliability, without sacrificing service level guarantees.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Bridging the Gap for Powering Data Centers

The rapid expansion of data centers, primarily driven by artificial intelligence, is outpacing the adaptability of the U.S. electric grid. This report, developed by Idaho National Laboratory (INL) , presents a gap analysis of some of the infrastructure challenges associated with large-scale data center deployment. Drawing from a national workshop hosted by INL in October of 2025, the report synthesizes stakeholder insights, survey data, and technical discussions to identify critical barriers and research needs. Key findings highlight the growing preference for behind-the-meter generation, the perceived inadequacy of legacy interconnection processes, and the urgent need for improved coordination between utilities, regulators, and data center developers. Environmental concerns such as water use and noise pollution, as well as economic constraints like equipment lead times and cost allocation, are also explored. The report outlines national lab capabilities in modeling, simulation, and technical assistance, and proposes targeted R&D priorities to support resilient, scalable, and efficient integration of data centers into the grid.

22 - GENERAL STUDIES OF NUCLEAR REACTORS↗

MegaWatt Mayhem: Grid Operator Challenges Center Loads

This report provides a summary of the challenges faced by United States electricity grid operators in accommodating and anticipating the rapid deployment of large loads, particularly data centers, based on academic literature and industry working groups. The report highlights the unique requirements and operational characteristics of data centers, which differ significantly from traditional industrial loads. Key issues addressed utility planning considerations, with emphasis on the implications for grid operators, impacts to normal operations for grid operators, reliability considerations during periods of grid stress, and resilience considerations for the changing operational paradigms based on data centers. Real-world examples are used to highlight these challenges and the changes that grid operators must address. The findings underscore the necessity for coordinated efforts and innovative solutions from both grid operators and regulatory bodies to ensure the stable integration of large loads into the grid. This report is the first in a series that will explore the challenges of data center deployments based on several key power system perspectives.

24 - POWER TRANSMISSION AND DISTRIBUTION↗