Search NASA⌕ Search

SEARCH · Search NASA

Results for “Cf-252”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 55 records · Page 3

239 Pu(n,f) Neutron Multiplicity Evaluation with CGMF-Very First Release Candidate. [Slides]

239 Pu(n,f) nu-bar evaluated with CGMF from E inc = 0.1-20 MeV. Changes compared to VIII.0: Prior: CGMF model included via Kalman and sensitivities of CGMF model parameters to nu-bar. Evaluation technique: Kalman including correction for PPP. Experimental data: Nearly all data that Phil took into account (I rejected: Huanqiao, Johnstone, Leroy, Nesterov, Smirenkin); New UQ for all experimental data; Marini; No correlations between unc. of different exp., except for Cf-252(sf) nu-bar uncertainty cross-correlating all uncertainties.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Development of Laser-Induced Breakdown Spectroscopy for the Californium-252 Supply Program

Calibration-free–laser-induced breakdown spectroscopy (CF-LIBS) is suggested as an alternative to traditional LIBS because it does not rely on calibration curves and instead relies on previously reported parameters called transition probabilities. Transition probabilities are fundamental parameters that describe the probability a specific transition from an upper energy to a lower energy will occur. These values act as internal calibrations and allow concentrations to be calculated based on the plasma temperature and electron density, which can be determined from Saha-Boltzmann methods. CF-LIBS provides the ability to perform elemental concentration estimations on samples without the need for chemical dilutions and only nanograms of material are ablated into the plasma. These benefits can be applied remotely inside hot cells, glove boxes, and radiation hoods through optical fibers. This report summarizes recent efforts to develop CF-LIBS methods for future applications within Oak Ridge National Laboratory’s radioisotope production portfolio, such as the Cf-252 Supply Program. Summaries are provided for the developed Python scripts for data analysis and two studies employing these programs to determine unreported transition probabilities of relevant lanthanides. Additionally, a review of fiber-delivered LIBS and a discussion of a LIBS fiber probe design are provided.

07 ISOTOPE AND RADIATION SOURCES↗

Shielding Benchmark Comparison - MCNP6.2

This report documents the calculations performed for a shielding code comparison between various Department of Energy (DOE) sites. These shielding calculations were performed using an experiment drawn from the International Handbook of Evaluated Criticality Safety Benchmark Experiments, published by the Organisation for Economic Cooperation and Development/Nuclear Energy Agency (OECD/NEA). The benchmark selected for comparison is ALARM-CF-AIR-LAB-001 (“Neutron Fields in the Three-Section Concrete Labyrinth from Cf-252 Source, Benchmark ALARM CF AIR LAB-001”). The Y-12 submission for this code comparison was performed with Monte Carlo N Particle (MCNP) Transport Code System, Version 6.2 and Automated Variance Reduction Generator (ADVANTG).

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

MC-Lite: Development of a new lightweight multiplicity counter

This report details the development of a neutron multiplicity counter based on lithium doped plastic scintillators. This system has the capability to measure and discriminate fast neutrons, thermal neutrons, and gamma-rays allowing for multi-particle correlations in one device. The system was built and tested at Lawrence Livermore National Laboratory with Cf-252 in both bare configurations and surrounded by polyethylene and compared against the MC-15 multiplicity counter. Additionally, the detector was also placed outside of a subcritical assembly and demonstrated the ability to use correlated gamma-rays as a probe on the multiplication of the item.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

User’s Manual for RESRAD-RDD&IND Code Version 2: Vol. 2—User’s Guide for RESRAD-RDD&IND Code

Version 2.0 of the RESRAD-RDD&IND computer code is designed to support the implementation of protective action guides (PAGs) after a nuclear emergency incident including a radiological dispersal device (RDD) and/or an improvised nuclear device (IND) incident (EPA 2017). Eight different group types, addressing various decisions, are available for selection. The RESRAD-RDD&IND code calculates radiological doses, stay times, etc., for the selected group that the user wishes to focus on. (That is, the results for all the groups are not calculated simultaneously, and the input for those other groups do not matter, although some parameter values are shared between groups.) Version 2.0 has a user-friendly interface so that the RESRAD-RDD&IND code can be used with minimal training. For example, the user can select the major characteristics of the problem-event type, source term, and decision type from the left side of the interface and then calculate the results with the default assumptions for the exposure scenarios. More in-depth analysis would include specifying site-specific exposure scenario characteristics in the right side of the interface. The procedures for data entry and results viewing are self-explanatory. This is because common window maneuvering features and text instructions were incorporated in the interface design. General and context-specific help are available to aid users entering parameter values, as well. The RESRAD-RDD&IND computer code gives the user the option to select either an RDD or IND incident for analysis. For an RDD event analysis, 11 radionuclides (Am-241, Cf-252, Cm-244, Co-60, Cs-137, Ir-192, Po-210, Pu-238, Pu-239, Ra-226, and Sr-90) are included. These 11 radionuclides are the radionuclides most likely used for an RDD. More than 90 radionuclides can be selected for an IND event analysis. Initial default concentrations are provided for 44 radionuclides for a uranium-fueled IND event. These 44 radionuclides are those that would contribute significantly to the radiation dose associated with a uranium-fueled bomb detonation. The radionuclides generated from ingrowth of these 44 initial radionuclides are also automatically included in the analysis. Pu-239, Cs-134m, Ru-105, and Rb-89 and their progeny can be selected for analysis if they are detected and their concentrations are determined. This user’s guide, which is Volume 2 of the User’s Manual for RESRAD-RDD&IND Code Version 2, provides instructions to users on how to install the RESRAD-RDD&IND code, navigate the interface, and use the various features, including those discussed above, to set up an analysis and view/print the results in text outputs. Volume 1 of the User’s Manual for RESRAD-RDD&IND Code Version 2 (Yu et al. 2026), which contains descriptions of the methodology and theoretical basis for dose modeling and the mathematical equations implemented in the code, can be accessed and viewed through the Help menu in the code or can be downloaded from the RESRAD website (https://resrad.evs.anl.gov).

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Bldg. 7930 Cell G Neutron Detector New Electronics Testing

The Cell G neutron assay system within 7930 provides an important function in the production of Californium-252 in the quantitative determination of the amount of Cf-252 present in a sample. The assay system consists of a Uranium-238 fission chamber coupled to the necessary counting electronics including preamplifier, amplifier, discriminator and counter/timer. The original electronics date back to the 1970s but were replaced back in 2011 with little documentation detailing the testing and replacement efforts. This work focused on procuring a new spare set of electronics, their subsequent testing as a backup in case any of the currently in use electronics were to fail and documentation of the existing and new setups.

Taylor, Neil [Oak Ridge National Laboratory (ORNL)↗

Deuterated Xylene-Based Neutron Spectrometry

Deuterated scintillators, such as deuterated xylene (C8D10) have been theorized to offer better pulse shape discrimination (PSD) and neutron spectrometry performance than traditional protiated scintillators due to the anisotropy of neutron scattering on deuterium. However, the light output responses of said deuterated scintillators to monoenergetic has not been characterized in its entirety at both high and low energies. Several time-of-flight experiments were conducted at the Idaho national Laboratory to characterize a pair of EJ-301D deuterated xylene detectors. The low energy detector response to quasi-monoenergetic neutrons was measured using a Cf-252 source, and the high energy detector response was measured using a D-T source and angles of 20, 45, and 60 deg, corresponding to theoretical neutron energies of 13.2, 10.4, and 8.2 MeV. During post-processing, the neutron and gamma bands were clearly able to be separated, even at low light outputs, solidifying the superior PSD capability of deuterated xylene. An exponential of fit of LO=0.63E-2.22*(1-exp(-0.25E)), which has good agreement with previously measured data, was found as the light output response from deuteron recoils. Additionally, measurements of AmBe, D-T, and D-D sources were unfolded using the light output response curve, which resulted in favorable agreement with theoretical values. Further testing of the response matrix by unfolding more sources (such as PuBe) needs to be done, but the unfolding accuracy for currently available sources suggests that deuterated xylene can be used to measure and unfold both fission, monoenergetic, and continuous spectra.

scintillator↗

A Simple Model of the Energy Threshold for Snowball Chambers

Cloud and bubble chambers have historically been used for particle detection, capitalizing on supersaturation and superheating, respectively. Here, we present new results from a prototype snowball chamber, in which an incoming particle triggers the crystallization of a purified, supercooled liquid. We demonstrate, for the first time, simulation agreement with our first results from 5 years ago: the higher temperature of the freezing of water and significantly shorter time spent supercooled compared to the control in the presence of a Cf-252 fission neutron source. This is accomplished by combining Geant4 modeling of neutron interactions with the Seitz nucleation model used in superheated bubble chambers, including those seeking dark matter. We explore the possible implications of using this new technology for GeV-scale WIMP searches, especially in terms of spin-dependent proton coupling, and report the first supercooling of WbLS (water-based liquid scintillator).

47 OTHER INSTRUMENTATION↗

Fast-timing Measurements in $^{100}$Zr Using LaBr$_{3}$(Ce) Detectors Coupled with Gammasphere

In order to investigate the evolution of nuclear deformation in the region of the chart of nuclides around mass numbers A similar or equal to 110 and A similar or equal to 150, an experiment was performed at the Argonne National Laboratory where the gamma-decay radiation emitted from the fission fragments of Cf-252 was measured using 51 Gammasphere detectors coupled with 25 LaBr3 (Ce) detectors. In this work, a short description of the experimental setup is presented together with some preliminary results from the fast-timing analysis of the 4(+) state of the nucleus Zr-100. A lifetime value of tau = 50(28) ps was obtained using the Generalized Centroid Shift Method. This result agrees with the literature value of tau = 53(4) ps within one standard deviation.

Gamba, E. R.↗

Future of the MUSiC Experiment Data

The Measurements of Uranium Subcritical and Critical (MUSiC) experiment was a highly enriched uranium (HEU) experiment performed at the National Criticality Experiments Research Center (NCERC) executed between December 2020 and April 2021. The experiment intended to measure criticality and reactor kinetics parameters in a bare HEU system. The experiment concurrently measured radiation signatures from the system while utilizing different neutron source types. This was an attempt to benchmark both detectors and analysis techniques against one another for identical measurements. The experiment consisted of the Rocky Flats HEU hemi-shells constructed into ten configurations spanning between deeply subcritical (about 14 kgs) to supercritical (about 60 kgs). Two of the ten configurations were supercritical and the other eight were subcritical. The two supercritical configurations, often referred to as the critical configurations, were documented into an International Criticality Safety Benchmark Evaluation Project (ICSBEP) benchmark evaluation and submitted to the technical review group (TRG). The subcritical configurations of the MUSiC experiment were examined using three different detection systems. The systems include: the NoMAD He-3 neutron detector which consists of 15 He-3 tubes surrounded by a polyethylene matrix, a liquid scintillator system called the Rossi-α Measurement Rapid Organic Discriminating Detector (RAM-RODD), and a trans-stilbene organic scintillator array (OSCAR) provided by the University of Michigan. The NoMAD and RAM-RODD data are planned to be evaluated in two separate ICSBEP evaluations utilizing neutron noise methods such as Feynman Variance-to-Mean, Rossi-α and the pulsed neutron source method. Each of the subcritical configurations were examined using three different source types including: a Cf-252 source in the center, with only the intrinsic neutron source in the HEU, and with an external D-T neutron generator.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Neutron Calibration Studies for the SuperCDMS SNOLAB Experiment

My time at Fermilab has been dedicated to advancing the field of dark matter detection through my contributions to the SuperCDMS collaboration. The first project involved the development and testing of a delivery system for a Cf-252 neutron source to calibrate the SuperCDMS silicon and germanium detectors. Subsequently, I focused on parametrizing the detectors' instrumental response by optimizing a plastic scintillator backing array to measure the scattering angle of a collimated neutron beam. The Monte Carlo simulation I designed provided insights into the detection efficiency of the array, and the best-fit design I arrived at for the scattering counters will be implemented into the final array. Additionally, I assembled a muon detector with legacy hardware to enhance the ability of the calibration experiment to reduce dark current and false signals. As my work nears completion, I am confident that these contributions will significantly enhance the precision and reliability of the SuperCDMS experiment, pushing the boundaries of our understanding of dark matter and contributing to the broader scientific community's quest to unravel the mysteries of the universe.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Development of Type A Transport Packagings - 17073a

ORNL ships a wide variety of radioisotopes. Many of these are associated with the DOE Isotope Program and Office of Nuclear Materials Integration (ONMI) and can be shipped as DOT Type A quantities of material. The DOT Specification 6M Type B packaging previously used for many shipments at ORNL is no longer authorized. Most materials could be shipped in Type B packagings, but many of them can meet the requirements for shipping as Type A. As a result, ORNL is working with a packaging manufacturer to develop, test, and certify several Type A packagings. These include a 38 L (10 gal) Type A packaging primarily to be used for transport of Cf-252 sources, a 208 L (55 gal) Type A packaging primarily to be used for transport of americium/curium/lanthanide oxide materials recovered from high-burnup targets, and a Type A packaging for transport of irradiated actinium targets. These are being developed with consideration for both gamma and neutron shielding for contents reading up to 5000 R/h. (authors)

07 ISOTOPE AND RADIATION SOURCES↗

Disposition Options for Mk-42 Materials - 17072

In the late 1980s, the DOE Defense Programs identified a need to recover special isotopes of americium, curium, and plutonium (Am/Cm/Pu) from Mark-42 (Mk-42) targets that had been irradiated at the SRS. Eighty Mk-42 target segments were transferred from SRS to ORNL for recovery of these special isotopes. Approximately 65% of the target materials has been processed and converted to solids. The remaining Mk-42 materials are either targets stored in their irradiated forms or target material stored from various stages of processing. The Pu, Am-243 and Cm-244 in these targets are valuable materials; for example, the Am/Cm materials are potential feedstocks for production of heavy actinides (Cf-252, Bk-249, etc.). Although the isotopes in the Mk-42 materials have value, there is continual pressure to look at de-inventorying material in storage to only retain the most valuable materials needed to meet mission needs and to allow other materials to be added to the inventory as they become available. Evaluations are underway for potential disposition options for the Mk-42 materials. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

The Off-Site Source Recovery Program Capabilities in Recovering Transuranic Sealed Sources - 17599

Over the past 16 years, the mission of the Off-Site Source Recovery Program (OSRP) has been recovering disused radioactive sealed sources in the interest of national security, public health and safety. This program, which is sponsored by the National Nuclear Security Administration's Office of Global Material Security's Office of Radiological Security, is managed at Los Alamos National Laboratory and Idaho National Laboratory and has recovered sources worldwide. To date, OSRP has recovered more than 38,000 sources from over 1,300 locations worldwide. Since its inception, OSRP has grown from recovering only sealed sources containing one transuranic (TRU) isotope, Pu-239, in the early days of the program, to recovering sealed sources containing several other TRU and non-TRU isotopes. Primarily, OSRP's mission includes Pu-238, Pu-239, Am-241, Cf-252, Cm-244, Sr-90, Cs-137, Co-60, Ir-192 and Ra-226 sources that are US-origin, defense related and not commercially disposable. Over the lifetime of this program the types of recoveries performed have expanded from a single site to multi-site round-up recoveries. An additional approach, referred to as self-ship recoveries, is also used in cases where only a few sources may be present at a licensee's site. In these situations, the licensee ships their source(s) to an OSRP staging facility for ultimate consolidation and disposal. OSRP recovers sources from many types of licensees, with the majority of sources being removed from industry, universities and hospitals. These include sealed sources used in industrial radiological devices like moisture-density gauges and thickness gauges, medical devices such as blood irradiators and radiotherapy devices and sealed sources from nuclear power plants, among others. The recovery and management of sealed sources is a complex process covering multidisciplinary areas, including source construction, characteristics of the radioactive material, source packaging and transportation per DOT regulations, safe and secure storage, and final disposition per waste acceptance criteria of repository sites. (authors)

07 ISOTOPE AND RADIATION SOURCES↗

Evaluation of Options for Disposition of Mk-42 Materials - 18034

In the late 1980's, the DOE defense programs identified a need to recover special isotopes of americium, curium, and plutonium from Mark-42 (Mk-42) targets that had been irradiated at the SRS. Eighty Mk-42 target segments were transferred from SRS to ORNL for recovery of these special isotopes. Approximately 65% of the target material has been processed, and the recovered material converted to solids. The remaining Mk-42 materials are stored either as targets in their irradiated forms or as target material from various stages of processing. The Pu, Am-243 and Cm-244 in these targets are valuable materials; for example, the Am/Cm materials are potential feedstocks for production of heavy actinides (Cf-252, Bk-249, etc.). In addition, rare long-lived fission product (LLFP) isotopes present in the targets in much smaller quantities, such as Zr-93, also have value to the research community. Although the isotopes in the Mk-42 materials have value, there is continual pressure to de-inventory the material in storage and only retain the most valuable materials needed to meet mission needs and provide inventory space for other materials to be added as they become available. Evaluations are underway for potential disposition options for the Mk-42 materials. Previous studies have included identification and evaluation of disposition options for the various Mk-42 materials in storage at ORNL [1]. Evaluations have included options for recovering the major isotopes and evaluating the waste that would be sent to disposal facilities. This paper summarizes the next steps in the evaluation process to develop an optimum path forward for the disposition of the Mk-42 materials. It includes an evaluation of the future programmatic need for the materials, the impact of storage on facility operations, and additional evaluations of options for dispositioning the materials. In addition to recovery of the major isotopes previously evaluated, it also looks at the potential to recover rare LLFP isotopes present in the targets in small quantities. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

A New Safeguards Technique for Spent Fuel Verification in Dry Storage by Using He-4 Detectors - 18262

It is demanded to find key issues and critical paths for verifying and monitoring a spent nuclear fuel cask or storage with a purpose of non-proliferation of nuclear weapon. However, unfortunately there are no reliable methods to verify the containment in a spent nuclear fuel cask or storage. Therefore, research and development (R and D) has been continuously required to develop new and alternative technologies for searching and verifying undeclared nuclear materials, activities, and facilities. Therefore, the present authors have developed a new safeguards technique of passively scanning a spent fuel cask or storage using pressurized He-4 scintillation neutron detectors. A new approach is to quickly verify content in a spent nuclear fuel cask or presence of all special nuclear materials in unknown packages by comparing experimental and computational results. For that, the present authors have developed a new algorithm and user-interface coupled ORIGEN-ARP and MCNP codes, and the prototype safeguards apparatus employing the array of He-4 fast neutron detectors has been designed, built, and tested. The feasibility test of this new apparatus has been performed with Cf-252 neutron sources and the laboratory scale model cask, minimized by a factor of ten compared to the actual dimension of a KN-21 cask. This technique has several advantages over current methods based on neutron and gamma detection; (1) incident neutron energy information is preserved, (2) disturbance of gamma-ray is excellently rejected (discriminated), and (3) much higher neutron counts and operational cost and space-effectiveness are expected since no moderator is required for fast neutrons. The final goal of this study will (1) conduct a prototype instrument and employ it to monitor a nuclear spent fuel cask or storage at a commercial nuclear power reactor facilities, (2) use spectral-specific measurement data to show proof of concept for measurable data successfully converted to quantifiable signatures, such as diversion/removal of fuel, and maintenance of fuel and cask integrity of fuel, and (3) develop a cask imaging capability. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

An Experimental Feasibility Study on Applying Neutron Tomography to Encapsulated Spent Nuclear Fuel - 20050

Visual inspection makes easier to ensure the integrity and safety of spent nuclear fuel (SNF) than any classical techniques. Various classical techniques have been applied but there are no reliable methods to qualitatively and quantitatively verify spent fuel in dry storage. Thus, the present authors have developed the prototype safeguards apparatus for dry storage employing the array of He-4 gas scintillation detectors (S670E, Arktis Radiation Detectors Ltd., Switzerland), newly designed to simultaneously measure thermal and fast neutrons without any moderators. The S670E detector has a cylindrical shape with a diameter of 52 mm and active length of 600 mm (total length: 875 mm). The detector is filled by He-4 gas with an approximate pressure of 180 bar for fast neutron detection, and its inner wall is coated by Li-6 for thermal neutron detection. The scintillation lights generated via Li-6 nuclear reaction and elastic scattering are collected by 24 SiPMs linearly paired at the center of the detector. The detector delivers a TTL (Transistor-Transistor Logic) output for pulse readout and UART (Universal Asynchronous Receiver Transmitter) for device control. In order to assess feasibility of the apparatus, an experimental system has been designed, built, and optimized via computational studies. Cf-252 neutron sources and linearly arrayed detectors, working as a single detector, were occupied for this study due to the difficulties in working with SNF. The laboratory scale cask (diameter: 0.67 m, height: 1.5 m), minimized by a factor of 10 compared to the actual thickness of a commercial TN-32 cask, was also manufactured. The detector array was designed to rotate the lab-scale cask and obtain 36 image profiles at every 10 degrees. All profiles were aligned in single frame image called a sinogram, and the cross-sectional image was then fabricated by the inverse radon transform algorithm. These experiments have been repeated with different configurations and numbers of sources. Some gamma-ray sources were also measured with neutron sources in order to distinguish between neutron and gamma-ray pulses. Basically, a He-4 detector is designed to run on Linux OS so it is difficult to directly apply to Windows-based equipment widely used in S. Korea. Therefore, a new data acquisition board working on Windows OS was designed and built. The board mainly consists of FPGA (Field Programmable Gate Array) and SoC (System on Chip) for TTL pulse readout, sorting measured data, and transferring data to a user interface. In conclusion, the tomographic system at lab-scale has shown considerable potential to detect a partial or gross defect of encapsulated assemblies in dry storage. Next steps of this study will be to 1) repeatedly carry out experiments to demonstrate scientific reliability and validity, and 2) numerically integrate signals with weight factors to enhance the image quality since the suggested system based on passive interrogation method requires longer measurement time. Finally, the system will apply to a commercial dry storage phased out soon in S. Korea. (authors)

07 ISOTOPE AND RADIATION SOURCES↗

Development and testing of a fission-like neutron field for dosimetry and instrument calibrations based on deuterium-tritium generator

For nearly five decades 252 Cf sources have been used for testing and calibration over a wide range of neutron detection devices used for nuclear safety and radiation protection. However, the vastly increased cost of 252 Cf sources, its short half-life, and concerns about future shortage have prompted nuclear facilities and radiological calibration laboratories that rely on high-intensity neutron sources to seek alternatives. There appear to be no other radionuclide neutron sources that would match “like-to-like” 252 Cf performance characteristics. Alternatives of producing a fission-like neutron spectrum based on commercially available deuterium-tritium (D-T) generators, and without any fissionable materials or beryllium, have been explored. This paper describes efforts of designing the spectrum shaping assembly, its construction and installation. The produced neutron field was evaluated both from the perspective of the neutron fluence spectrum and the resulting dosimetric outcome. Finally, it was tested for practical application by examining response of various health physics instruments and personal monitoring devices in comparison to the response of those devices when exposed to 252 Cf. In conclusion, the response of survey-type instruments tested within the prototype, surrogate fission, reference field are acceptably close to their response in the targeted 252 Cf field.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗