Search NASA⌕ Search

SEARCH · Search NASA

Results for “Charge-Coupled Devices”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 55 records · Page 3

A Multichannel Silicon Package for Large-Scale Skipper-CCD Experiments

The next generation of experiments for light-dark-matter and neutrino searches based on skipper charge-coupled devices (skipper-CCDs) introduces new challenges for the sensor packaging and readout architecture. Scaling the active mass while simultaneously reducing the experimental backgrounds in orders of magnitude requires a novel high-density silicon-based package that must be massively produced and tested. In this work, we present a silicon multichip module design capable of hosting up to 16 skipper-CCDs, along with the fabrication process for the first prototypes. We thoroughly tested and characterized the assembled prototypes to build an empirical model for the video output signal of skipper-CCDs integrated into the silicon package. We then used this model in simulations to optimize the fabrication process and achieve the robust performance required for the full-scale array, which we validated through a new round of prototype fabrication. We outline the specifications selected for the ongoing production of 1500 silicon wafers that will ultimately add up to a 10-kg skipper-CCD array with 24000 readout channels.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Effect of Approach Speed and Electrode Geometry on Electrostatic Discharges Off Floating Dielectrics

With the damaging effects of electrostatic discharges (ESDs), it is important to study them within various parameter regimes relevant to real-world scenarios. One such scenario studied here is a floating dielectric with no nearby ground plane with a grounded object approaching at a high rate of speed. One may encounter this scenario when moving objects by hand. Discharge current and radiated fields are captured for discharges drawn from polytetrafluoroethylene (PTFE) and poly methyl methacrylate (PMMA) with approach speeds ranging from 20 to 100 mm/s. Previous studies have shown that at lower speeds in metal-to-metal or metal-to-ground backed dielectric geometries, the peak current and discharge distance decrease with increasing speed. However, in the speed range studied here, an increase in distance and current are observed for increasing speed. Namely, the highest speeds coincide with the highest peak currents and discharge distances of approximately 800 mA and up to 24 mm. Further, with no grounded backing, as opposed to setups in other ESD studies, the electric field between the dielectric and an approaching electrode has a more uniform distribution with highest fields at the electrode, which is elucidated to be the driving factor in the differences revealed in this study. Two spheres of differing diameters and a conical electrode are used to draw discharges off the dielectric surfaces. Captured radiated fields via B-dot sensor, plasma imagery via intesified charge-coupled device (ICCD), and mapping of surface potential reveal that a majority of the energy lost during a discharge goes to gas losses and radiated fields.

36 MATERIALS SCIENCE↗

Advanced Shuttle Strategies for Parallel QCCD Architectures

Trapped ions (TIs) are at the forefront of quantum computing implementation, offering unparalleled coherence, fidelity, and connectivity. However, the scalability of TI systems is hampered by the limited capacity of individual ion traps, necessitating intricate ion shuttling for advanced computational tasks. The quantum charge-coupled device (QCCD) framework has emerged as a promising solution, facilitating ion mobility for universal quantum computation. Current QCCD architectures predominantly feature a linear topology, which is increasingly recognized as inefficient for complex quantum operations. Anticipating the shift toward more efficacious designs, this article introduces an innovative quantum scheduling strategy optimized for parallel QCCD topologies. Our strategy proposes a probabilistic formula for ion movement, alongside ingenious methods for local layer generation and layer compression, yielding a significant reduction in ion shuttle times. Through simulations, we demonstrate that our strategy not only substantially outstrips the linear model but also exhibits better performance over other parallel strategies that employ greedy algorithms. This is achieved through our nuanced resolution of complexities, such as traffic blocks and trap capacity limitations. The consequent reduction in shuttle operations leads to lower energy consumption and an enhancement in the quantum computer's fidelity, ultimately accelerating program execution times.

43 PARTICLE ACCELERATORS↗

Cherenkov photon background for low-noise silicon detectors in space

Future space observatories dedicated to direct imaging and spectroscopy of extra-solar planets will require ultra-low-noise detectors that are sensitive over a broad range of wavelengths. Silicon charge-coupled devices (CCDs), such as EMCCDs, Skipper CCDs, and Multi-Amplifier Sensing CCDs, have demonstrated the ability to detect and measure single photons from ultra-violet to near-infrared wavelengths, making them candidate technologies for this application. In this context, we study a relatively unexplored source of low-energy background coming from Cherenkov radiation produced by energetic charged particles traversing a silicon detector. In the intense radiation environment of space, energetic cosmic rays produce high-energy tracks and more extended halos of low-energy Cherenkov photons, which are detectable with ultra-low-noise detectors. We present a model of this effect that is calibrated to laboratory data, and we use this model to characterize the residual background rate for ultra-low noise silicon detectors in space. We find that the rate of cosmic-ray-induced Cherenkov photon production is comparable to other detector and astrophysical backgrounds that have previously been considered.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

In vitro and in vivo NIR fluorescence lifetime imaging with a time-gated SPAD camera

Near-infrared (NIR) fluorescence lifetime imaging (FLI) provides a unique contrast mechanism to monitor biological parameters and molecular events in vivo . Single-photon avalanche diode (SPAD) cameras have been recently demonstrated in FLI microscopy (FLIM) applications, but their suitability for in vivo macroscopic FLI (MFLI) in deep tissues remains to be demonstrated. Herein, we report in vivo NIR MFLI measurement with SwissSPAD2, a large time-gated SPAD camera. We first benchmark its performance in well-controlled in vitro experiments, ranging from monitoring environmental effects on fluorescence lifetime, to quantifying Förster resonant energy transfer (FRET) between dyes. Next, we use it for in vivo studies of target-drug engagement in live and intact tumor xenografts using FRET. Information obtained with SwissSPAD2 was successfully compared to that obtained with a gated intensified charge-coupled device (ICCD) camera, using two different approaches. Our results demonstrate that SPAD cameras offer a powerful technology for in vivo preclinical applications in the NIR window.

47 OTHER INSTRUMENTATION↗

Even lighter particle dark matter

We report on recent progress in the search for dark matter particles with masses from 1 Mev c ^{-2} − 2 to 1 Gev c ^{-2} − 2 . Several dark matter candidates in this mass range are expected to generate measurable electronic-recoil signals in direct-detection experiments. We focus on dark matter particles scattering with electrons in semiconductor detectors since they have fundamentally the highest sensitivity due to their low ionization threshold. Charge-coupled device (CCD) silicon detectors are the leading technology, with significant progress expected in the coming years. We present the status of the CCD program and briefly report on other efforts.

Chavarria, Alvaro E.↗

Exploring transport-enabled gates with integrated optical addressing to demonstrate high fidelity control of trapped ion qubits in a scalable quantum computer

In recent years, experiments involving micofabricated surface ion traps have grown in complexity, and as this complexity grows, a common design has emerged in the form of quantum charge-coupled device architecture. This architecture, already utilized on multiple systems, supports multiple zones on a device for areas such as memory or computation. The shutting process between these zones is a process often seen to be minimized. An additional component to scalable surface trapped-ion experiments includes some form of integrated photonics, as free space lasers have difficulty scaling to many ions. Here, we discuss recent results in utilizing the shuttling process with integrated photonics to perform a specific type of gate, as well as demonstrating state preparation. Furthermore, we show that these gates can be utilized as a type of optical modulator as the Doppler shift that occurs during shuttling will make the light seen by shuttled ions different than that seen by stationary ions. Furthermore, we show that the shuttling operation can be utilized as an optical modulator, where the Doppler shift changes the frequency from that of a stationary ion.

42 ENGINEERING↗

Ultrafast CMOS image sensors and data-enabled super-resolution for multimodal radiographic imaging and tomography

We summarize recent progress in ultrafast Complementary Metal Oxide Semiconductor (CMOS) image sensor development and the application of neural networks for post-processing of CMOS and charge-coupled device (CCD) image data to achieve sub-pixel resolution (thus ‘super-resolution’). The combination of novel CMOS pixel designs and data-enabled image post-processing provides a promising path towards ultrafast high-resolution multi-modal radiographic imaging and tomography applications.

47 OTHER INSTRUMENTATION↗

Plasma Emission, Wave Speeds, and Temperatures of Laser-Supported Plasmas in Air

A study of the generation and subsequent expansion of plasmas using a single beam (532 nm) from the second harmonic generator of a Q-switched Nd:YAG laser is described. The plasmas in air are studied using an intensified charge-coupled device camera over periods of 1000 ns following the laser pulses. The plasma experimental results are interpreted in terms of wave speeds and plasma temperatures. Energy balance equations are considered to estimate the plasma temperatures and the laser-supported radiation (LSR) and the laser-supported detonation (LSD) wave speeds. Within 1000 ns observation time, the circular spectral images turn elliptical because of plasma expansion toward the laser beam. The plasma expansion increases with increasing laser irradiance. A laser irradiance range of [Formula: see text] yields LSR wave speeds between 45 and 170 km/s and LSD wave speeds of 90–130 km/s. The measured wave speeds are compared with the LSR and the LSR wave speed models. The plasma temperatures are between 90,000 and 120,000 K at 15 ns after the laser pulse based on measured emission spectra and are between 640,000 and 760,000 K at 3 ns based on the LSR model.

Engineering↗

Photometric Recalibration of the SDSS Stripe 82 to a Few Millimagnitude Precision with the Stellar Color Regression Method and Gaia EDR3

By combining spectroscopic data from the LAMOST DR7, Sloan Digital Sky Survey (SDSS) DR12, and corrected photometric data from the Gaia EDR3, we apply the stellar color regression (SCR) method to recalibrate the SDSS Stripe 82 standard stars catalog of Ivezic' et al. With a total number of about 30,000 spectroscopically targeted stars, we have mapped out the relatively large and strongly correlated photometric zero-point errors present in the catalog, ~2.5% in the u band and ~1% in the griz bands. Our study also confirms some small but significant magnitude dependence errors in the z band for some charge-coupled devices. Various tests show that we have achieved an internal precision of about 5 mmag in the u band and about 2 mmag in the griz bands, which is about five times better than previous results. We also apply the method to the latest version of the catalog (v4.2), and find modest systematic calibration errors of up to ~1% along the R.A. direction and smaller errors along the decl. direction. The results demonstrate the power of the SCR method when combining spectroscopic data and Gaia photometry in breaking the 1% precision barrier of ground-based photometric surveys. Our work paves the way for the recalibration of the whole SDSS photometric survey and has important implications for the calibration of future surveys. Future implementations and improvements of the SCR method under different situations are also discussed.

79 ASTRONOMY AND ASTROPHYSICS↗

Precision measurement of Compton scattering in silicon with a skipper CCD for dark matter detection

Experiments aiming to directly detect dark matter through particle recoils can achieve energy thresholds of $\mathcal{O}(1\,\mathrm{eV})$. In this regime, ionization signals from small-angle Compton scatters of environmental $\gamma$-rays constitute a significant background. Monte Carlo simulations used to build background models have not been experimentally validated at these low energies. We report a precision measurement of Compton scattering on silicon atomic shell electrons down to 23$\,$eV. A skipper charge-coupled device (CCD) with single-electron resolution, developed for the DAMIC-M experiment, was exposed to a $^{241}$Am $\gamma$-ray source over several months. Features associated with the silicon K, L$_{1}$, and L$_{2,3}$-shells are clearly identified, and scattering on valence electrons is detected for the first time below 100$\,$eV. We find that the relativistic impulse approximation for Compton scattering, which is implemented in Monte Carlo simulations commonly used by direct detection experiments, does not reproduce the measured spectrum below 0.5$\,$keV. The data are in better agreement with $ab$$initio$ calculations originally developed for X-ray absorption spectroscopy.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Ultrafast CMOS image sensors and data-enabled super-resolution for multimodal radiographic imaging and tomography

We summarize recent progress in ultrafast Complementary Metal Oxide Semiconductor (CMOS) image sensor development and the application of neural networks for post-processing of CMOS and charge-coupled device (CCD) image data to achieve sub-pixel resolution (thus $super$-$resolution$). The combination of novel CMOS pixel designs and data-enabled image post-processing provides a promising path towards ultrafast high-resolution multi-modal radiographic imaging and tomography applications.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Characterization of Non-Science Grade DESI CCDs and Creating Additional ICARUS Monitoring Metrics for Data Quality

DESI, otherwise known as the Dark Energy Spectroscopic Instrument, is an astronomical project measuring millions of optical spectra to characterize Dark Energy. The survey has been running for 3 years. My work delves into the data taking/analysis side of the DESI CCDs (Charge-Coupled Devices) which will help in swapping out broken CCDs on the instrument. Additionally, I worked on making new metrics for ICARUS, Imaging Cosmic and Rare Underground Signals for their monitoring of run data. This paper will talk about the types of characterizations done for DESI and additional metrics for data quality and tools used for ICARUS monitoring.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Charge Trap Analysis in a SENSEI Skipper-CCD: Understanding Low-Energy Backgrounds in Rare-Event Searches

Skipper Charge-Coupled Devices (Skipper-CCDs) are ultra-low-threshold detectors capable of detecting energy deposits in silicon at the eV scale. Increasingly used in rare-event searches, one of the major challenges in these experiments is mitigating low-energy backgrounds. In this work, we present results on trap characterization in a silicon Skipper-CCD produced in the same fabrication run as the SENSEI experiment at SNOLAB. Lattice defects contribute to backgrounds in rare-event searches through single-electron charge trapping. To investigate this, we employ the charge-pumping technique at different temperatures to identify dipoles produced by traps in the CCD channel. We fully characterize a fraction of these traps and use this information to extrapolate their contribution to the single-electron background in SENSEI. We find that this subpopulation of traps does not contribute significantly but more work is needed to assess the impact of the traps that can not be characterized.

Brusco, Agustin [Buenos Aires U.]↗

MAS-CCD: New technique for measuring low-level charge content based on the multiple amplifier architecture

Low-noise detectors are a key technology for the next generation of astronomical instruments aimed at spectroscopy of faint objects and the search for exoplanets. In this context, the multiple-amplifier sensing charge-coupled device (MAS-CCD) emerges as a promising technology for future scientific instruments. A critical parameter affecting the performance of these devices is spurious charge, produced by the clocking of the gates. Its measurement is typically challenging with existing methods. In practice, the optimization of this parameter often relies on empirical procedures that require significant time and careful consideration of the trade-off with full-well capacity. In this work, we present a new technique to estimate spurious charge based on covariance analysis of the output amplifiers of the MAS-CCD, which measures the same charge packet in different amplifiers at different times. The method enables fast and precise measurements of spurious charge under operating conditions where conventional approaches are difficult to apply. We develop the theoretical framework of the method and validate the model through simulations. The results demonstrate the feasibility of this approach and suggest that it could serve as a basis for reliable large-scale characterization of sensor performance.

Gamero, Miqueas E. [Buenos Aires, CONICET; Fermila↗

Characterization of Spurious Charge in SENSEI Skipper-CCDs

Skipper Charge-Coupled Devices (Skipper-CCDs) are a leading technology in the search for sub-GeV dark matter and coherent elastic neutrino-nucleus scattering. A key background for rare-event searches with these detectors arises from "spurious charge" -- single-electron events generated when charges are transferred through the active region to the serial register, and across the serial register to the readout stage. We present a characterization of spurious charge in both the active region and the serial register of SENSEI Skipper-CCDs, and show that, in a well-shielded low-background environment, the dominant contribution originates in the serial register during Skipper readout, when horizontal clocks are held at constant voltage between pixel transfers. Motivated by this finding, we develop a "tri-level" clocking scheme in which the held-low phase is raised to an intermediate voltage during readout to suppress trap-mediated charge generation. Using the SENSEI detector near the MINOS cavern, we measure a serial-register single-electron density of $(2.9 \pm 0.1) \times 10^{-5}$ electrons/pixel/image under standard SENSEI readout conditions, reduced to $(4.0 \pm 0.4) \times 10^{-6}$ electrons/pixel/image with tri-level clocking -- a factor of $\sim$7 improvement. This technique offers a promising path to lower backgrounds in current and future Skipper-CCD experiments.

Wu, Yikai [YITP, Stony Brook; SUNY, Stony Brook]↗

In situ cryogenic characterization of proton damage in thick p-channel skipper CCDs

Skipper charge-coupled devices (CCDs) are an offshoot of standard silicon pixel detectors and are capable of performing repeated non-destructive charge measurements, enabling deeply sub-electron readout noise. This capability has opened the door to single-photon counting from the near-infrared ($\sim$1.1 $μ$m) to the soft X-ray (several keV), making these devices strong candidates for future astronomical instruments operating in the photon-starved limit. Furthermore, the p-channel architecture used to fabricate Skipper CCDs on n-type silicon has been demonstrated to have an increased hardness to the intense radiation environment of space. Building upon previous irradiation campaigns on room-temperature sensors, here we describe the first radiation-hardness tests of p-channel skipper CCDs at their cryogenic operating temperatures. We assess the performance of the floating-gate output stage and global CCD parameters (charge transfer inefficiency, dark current, hot pixels, and charge traps). We find that these devices maintain excellent performance after displacement damage doses equivalent to ${\sim}$10 years at the Earth/Sun L2 Lagrange point, demonstrating for the first time that these sensors remain radiation-hard in realistic deep-space thermal and radiation environments.

Roach, Brandon M. [Chicago U., KICP] (ORCID:000000↗

Characterization of Advanced Imaging Systems for High-Resolution and Event-Mode Detection

Post-irradiation examination (PIE) is a continually growing field critical to the development of improved nuclear fuels. To characterize these materials, neutron imaging systems are employed and outfitted with, typically, CMOS or CCD cameras - complementary metal oxide semiconductor sensors and charge-couple devices. Imaging systems are a team-effort between the camera, scintillating materials, and object of interest, as a result of neutrons' inherent need to be converted to a detectable signal. High resolution imaging, flash radiography imaging, and event-mode detection systems are three systems undergoing development, construction, and characterization for improved spatial resolution and time-of-flight detection for PIE efforts.

11 - NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗