Analytical modeling of satellites in geosynchronous environment

Experiences with surface charging of geosynchronous satellites are reviewed and mechanisms leading to discharges on satellite surfaces are considered. It was found that the large differential voltages between the surface and the substrate required to produce massive laboratory discharges do not occur on satellites in space. Analytical modeling predictions supported by dielectric charging data from P78-2, SCATHA (Spacecraft Charging at High Altitudes) flight results are discussed. Ungrounded insulator areas, buried charge layers (due to mid-energy range particles), and positive differential voltages (where structure voltages are less negative than surrounding dielectric surface voltages) are considered as possible mechanisms producing satellite charge up.

Stevens, N. J.↗

Analysis of Electric Vehicle Charging Impact on the Electric Power Grid

In order to evaluate the impact of electric vehicles (EVs) on the distribution grid and assess their potential benefits to the future smart grid, it is crucial to study the EV charging patterns and the usage charging station. Though EVs are not yet widely adopted nationwide, a valuable methodology to conduct such studies is the statistical analysis of real-world charging data. This paper presents actual EV charging behavior of 64 EVs (5 brands, 8 models) from EV users and charging stations at Los Angeles Department of Water and Power for more than one year. Twenty-four-hour EV charging load curves have been generated and studied for various load periods: daily, monthly, seasonally and yearly. Finally, the effect and impact of EV load on the California distribution network are evaluated at different EV penetration rates.

33 ADVANCED PROPULSION SYSTEMS↗

Pilot Heavy-Duty Electric Vehicle Deployment for Anchorage, Alaska, Municipal Solid Waste Collection

Through a grant awarded by the U.S. Department of Energy, the Municipality of Anchorage initiated a pilot program in their Solid Waste Services (SWS) department to add heavy-duty electric trucks to its vehicle fleet. The project involves the purchase and deployment of a Peterbilt 220EV electric box truck and two Peterbilt 520EV heavy-duty electric refuse trucks. The Alaska Center for Energy and Power at the University of Alaska Fairbanks performed data analysis. Data collected include telemetry data from both types of electric trucks, charging data from the 520EV telemetry data and a Level 2 charger, and facility-level electric use data.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Pilot Heavy-Duty Electric Vehicle Deployment for Anchorage, Alaska, Municipal Solid Waste Collection

Through a grant awarded by the U.S. Department of Energy, the Municipality of Anchorage initiated a pilot program in their Solid Waste Services (SWS) department to add heavy-duty electric trucks to its vehicle fleet. The project involves the purchase and deployment of a Peterbilt 220EV electric box truck and two Peterbilt 520EV heavy-duty electric refuse trucks. The Alaska Center for Energy and Power at the University of Alaska Fairbanks performed data analysis. Data collected include telemetry data from both types of electric trucks, charging data from the 520EV telemetry data and a Level 2 charger, and facility-level electric use data.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Use and Siting of Electric Vehicle Charging Stations in Juneau, Alaska

This report details a study of electric vehicle (EV) Level 2 charging stations in Juneau, Alaska. Utilization analyses of six public over five years and 250 residential chargers over two years are included, and a composite score is introduced to identify optimal locations for future charging stations that target residents of manufactured and multifamily housing (MMFH) in Juneau. We find that public charging station usage is very location-dependent, with three chargers in use more than 60% of days during the peak hour of the day (which ranges from 10 a.m. to 7 p.m.), including a charger near residential housing, illuminating potential needs for additional public chargers in those areas. Residential charging utilization typically occurs overnight - opposite to most public charging stations analyzed - and spikes after 10 p.m. This suggests that Alaska Electric Light & Power Company's time-of-use charging program, which lowers electricity rates at 10 p.m. to incentivize overnight charging, is very effective. Residential charging data also show that households tend to charge 15 hours per week, or 9% of the time, meaning that multiple households could likely share one charger if one were provided near MMFH locations. This is supported by residential charging session analysis, which shows that the median household has around two night charging sessions per week. The EV siting analysis identifies areas of high housing density, low access to public chargers, and unconstrained feeders. A cluster of MMFH parcels in Douglas demonstrated the highest composite scores considering all factors, being the only area to have a perfect score of 2.25.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Advancing Grid Resilience through Smart Charge Management: Findings from Maryland’s Pilot

This report presents research findings from a four-year Smart Charge Management (SCM) pilot program conducted by Maryland’s largest electric utilities—Baltimore Gas and Electric (BGE), Potomac Electric Power Company (Pepco), and Delmarva Power & Light (DPL)—to evaluate strategies for optimizing electric vehicle (EV) charging loads and enhancing grid stability. Supported by the U.S. Department of Energy (DOE), Argonne National Laboratory collaborated with all project partners and examined the effectiveness of Time-of-Use (TOU) and Load Balancing (LB) strategies in managing peak demand, deferring costly infrastructure upgrades, and reducing grid constraints at the feeder level. Using charging data from over 4,600 EV drivers, the study analyzed SCM’s impact on the distribution systems of BGE and Pepco, which consists of over 2000 feeders. Unlike prior research that focused on system-wide trends or synthetic feeders, this analysis offers granular, feeder-level insights based on real-world operational data. It highlights how transformer density, load profiles, and infrastructure constraints influence smart charging performance. Results show feeder-level conditions play a crucial role in SCM effectiveness, with most feeders benefiting more from LB, while TOU-based SCM may be sufficient for others. By 2035, LB reduced peak charging loads by 27% on average, compared to 23% under TOU-based SCM, though some feeders saw reductions exceeding 35%, while others experienced minimal impact. Feeders with higher transformer utilization and limited capacity benefited more from LB, which more effectively distributed charging demand during off-peak hours. Beyond reducing grid constraints, SCM offers long-term operational and financial benefits. By shifting EV charging demand strategically, utilities can optimize asset utilization, delay infrastructure investments, and enhance grid performance. In terms of infrastructure upgrade deferrals, at the feeder level, LB consistently reduced peak charging loads and resulting infrastructure upgrade costs, particularly in high EV enrollment areas, decreasing the number of overloaded transformers by up to 35%, while TOU-based SCM achieved 20-30% reductions depending on feeder characteristics. At the system level, LB has the potential to defer total upgrade costs by $\$$186 million for BGE, compared to $\$$159 million under TOU-based SCM. For Pepco, TOU-based SCM performed slightly better, deferring upgrade costs by $\$$30 million, compared to $\$$29 million under LB. Section 4.5 reviews some of the system differences between BGE and Pepco. However, as EV adoption scales, TOU-based SCM will introduce secondary peak charging loads, reinforcing the need for more advanced, adaptive SCM approaches to prevent new grid challenges. As EV adoption continues to grow, feeder-level managed charging strategies will be essential for mitigating grid stress, improving infrastructure efficiency, and maintaining energy affordability for consumers. This report provides critical insights for utilities, Public Utility Commissions (PUCs), and state agencies on the role of feeder-specific smart charging in infrastructure planning, policy development, and grid modernization. The findings underscore the importance of tailored, data-driven SCM solutions that align with local grid conditions, ensuring a resilient, cost-effective transition to increasing EV adoption while safeguarding distribution system performance.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Public electric vehicle charging station utilization in the United States

The utilization of electric vehicle (EV) charging equipment is a key driver of charging station economics, but current trends and factors related to the utilization of public charging infrastructure in the United States are not well understood. This study analyzes EV charging data from 3,705 nationwide public Level 2 (L2) and direct current fast charging (DCFC) stations over 2.5 years (2019-2022), observing utilization patterns over time. Regression analysis is used to assess the relationships between station utilization and several contextual and environmental factors. We conclude that local EV adoption is a strong indicator of utilization; L2 station utilization decreases with the size of the local charging network, while DCFC stations are less affected; and increased charging power has a greater effect on utilization for DCFC stations than L2. This study fills a critical research gap by reporting updated public charging station utilization statistics and analysis for the U.S. market.

33 ADVANCED PROPULSION SYSTEMS↗

Controlled workplace charging of electric vehicles: The impact of rate schedules on transformer aging

To accelerate adoption of non-residential charging for electric vehicles, sites must maximize utilization of existing electrical infrastructure. In this study we model electric vehicle charging at a workplace using real charging data and evaluate the lifetime of the site’s transformer as the number of charging stations is incrementally increased. We implement and compare a range of control schemes for workplace charging including minimizing the peak load, capping the total load, minimizing bills under different rate structures with time-of-use energy costs and demand charges, and directly minimizing the transformer’s aging. These are compared by the number of vehicles they allow the transformer to support, the transformer’s health, and the operator’s electricity bill. We draw a connection between minimizing the peak load and improving the transformer’s health. We observe that minimizing the electricity bill is the best scheme by both criteria when the bill includes a demand charge; in our experiment it allowed the infrastructure to support over 67% more cars than under uncontrolled charging. To protect the transformer we recommend that demand charges or capacity management be applied to parking lots of charging electric vehicles with high infrastructure utilization, and operators schedule charging to minimize their electricity bills.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Workplace Charge Management with Aggregated Building Loads

This paper describes a workplace charge management system developed to control plug-in electric vehicle charging stations based on aggregated building loads. A system to collect information from drivers was also developed for better charge management performance since the present AC charging station standard does not provide battery state of charge information. First, simulations with uncontrolled charging data were conducted to investigate several scenarios and control methods, and then one method with the most power curtailment during peak load was selected for verification tests. This paper illustrates load reduction test results for 36 charging stations and real-time campus net load data.

25 ENERGY STORAGE↗

220EV Box Truck Telemetry Dataset

This dataset contains telemetry data for the 520EV refuse trucks accessed through a Veracity data platform as provided by Peterbilt. The dataset contains driving data on both electric trucks used by SWS. Data were recorded at an hourly resolution and contain energy use data while driving and idling, distance driven (miles), and driving speed (miles per hour). This dataset also contains charging data on the fast charger in kilowatt-hours for each hour.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

520EV Refuse Truck Telemetry Dataset

This dataset contains telemetry data for the 520EV refuse trucks accessed through a Veracity data platform as provided by Peterbilt. The dataset contains driving data on both electric trucks used by SWS. Data were recorded at an hourly resolution and contain energy use data while driving and idling, distance driven (miles), and driving speed (miles per hour). This dataset also contains charging data on the fast charger in kilowatt-hours for each hour.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Understanding EV Charging Pain Points Through Deep Learning Analysis

Current and potential electric vehicle (EV) owners express concerns about the charging infrastructure, mentioning non-functional chargers, prolonged charging times, inconvenient charger locations, long wait times, and high costs as major barriers. Addressing these issues often requires analyzing actual vehicle charging data, which is typically proprietary and inconsistent due to diverse standards and protocols. To understand and improve the EV charging experience, customer reviews are typically used to identify common customer pain points (CPPs). However, there is not a comprehensive method to map customer reviews to a standardized set of CPPs. In collaboration with the National Charging Experience (ChargeX) Consortium, this study bridges these gaps by proposing a Systematic Categorization and Analysis of Large-scale EV-charging Reviews (SCALER) framework. SCALER is an integrated, deep learning framework that segments, actively labels, analyzes, and classifies EV charging customer reviews into six CPP categories. To test its effectiveness, we used SCALER to analyze over 72,000 reviews from customers charging various EV models on different networks across the United States. SCALER achieves a classification accuracy of 92.5%, with an F1 score exceeding 85.7%. By demonstrating real-world applications of SCALER, we enhance the industry’s ability to understand and address CPPs to improve the EV charging experience.

29 - ENERGY PLANNING, POLICY AND ECONOMY↗

Project Startup: Evaluating the Performance of Frito Lay's Electric Delivery Trucks (Fact Sheet)

The Fleet Test and Evaluation Team at the National Renewable Energy Laboratory (NREL) is evaluating the in-service performance of 10 medium-duty Smith Newton electric vehicles (EVs) and 10 comparable conventional diesel vehicles operated by Frito Lay North America in the Seattle, Washington, area. Launched in late 2013, the on-road portion of this 12-month evaluation focuses on collecting and analyzing vehicle performance data, such as fuel economy and maintenance costs, to better understand how to optimize the use of such vehicles in a large-scale commercial operation. In addition to the on-road portion of this evaluation, NREL is analyzing charging data to support total cost of ownership estimations and investigations into smart charging opportunities. NREL is also performing a battery life degradation analysis to quantify battery pack health, track battery performance over time, and determine how various drive cycles and battery charging protocols impact battery life.

25 ENERGY STORAGE↗

Charged fermions below 100 GeV

How light can a fermion be if it has unit electric charge? We revisit the lore that LEP robustly excludes charged fermions lighter than about 100 GeV. We review LEP chargino searches, and find them to exclude charged fermions lighter than 90 GeV, assuming a higgsino-like cross section. However, if the charged fermion couples to a new scalar, destructive interference among production channels can lower the LEP cross section by a factor of 3. In this case, we find that charged fermions as light as 75 GeV can evade LEP bounds, while remaining consistent with constraints from the LHC. As the LHC collects more data, charged fermions in the 75–100 GeV mass range serve as a target for future monojet and disappearing track searches.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Statistical Characterization of Medium-Duty Electric Vehicle Drive Cycles: Preprint

In an effort to help commercialize technologies for electric vehicles (EVs) through deployment and demonstration projects, the U.S. Department of Energy’s (DOE's) American Recovery and Reinvestment Act (ARRA) provided funding to participating U.S. companies to cover part of the cost of purchasing new EVs. Within the medium- and heavy-duty commercial vehicle segment, both Smith Electric Newton and and Navistar eStar vehicles qualified for such funding opportunities. In an effort to evaluate the performance characteristics of the new technologies deployed in these vehicles operating under real world conditions, data from Smith Electric and Navistar medium-duty EVs were collected, compiled, and analyzed by the National Renewable Energy Laboratory's (NREL) Fleet Test and Evaluation team over a period of 3 years. More than 430 Smith Newton EVs have provided data representing more than 150,000 days of operation. Similarly, data have been collected from more than 100 Navistar eStar EVs, resulting in a comparative total of more than 16,000 operating days. Combined, NREL has analyzed more than 6 million kilometers of driving and 4 million hours of charging data collected from commercially operating medium-duty electric vehicles in various configurations. In this paper, extensive duty-cycle statistical analyses are performed to examine and characterize common vehicle dynamics trends and relationships based on in-use field data. The results of these analyses statistically define the vehicle dynamic and kinematic requirements for each vehicle, aiding in the selection of representative chassis dynamometer test cycles and the development of custom drive cycles that emulate daily operation. In this paper, the methodology and accompanying results of the duty-cycle statistical analysis are presented and discussed. Results are presented in both graphical and tabular formats illustrating a number of key relationships between parameters observed within the data set that relate to medium duty EVs.

33 ADVANCED PROPULSION SYSTEMS↗

Statistical Characterization of Medium-Duty Electric Vehicle Drive Cycles

In an effort to help commercialize technologies for electric vehicles (EVs) through deployment and demonstration projects, the U.S. Department of Energy's (DOE's) American Recovery and Reinvestment Act (ARRA) provided funding to participating U.S. companies to cover part of the cost of purchasing new EVs. Within the medium- and heavy-duty commercial vehicle segment, both Smith Electric Newton and and Navistar eStar vehicles qualified for such funding opportunities. In an effort to evaluate the performance characteristics of the new technologies deployed in these vehicles operating under real world conditions, data from Smith Electric and Navistar medium-duty EVs were collected, compiled, and analyzed by the National Renewable Energy Laboratory's (NREL) Fleet Test and Evaluation team over a period of 3 years. More than 430 Smith Newton EVs have provided data representing more than 150,000 days of operation. Similarly, data have been collected from more than 100 Navistar eStar EVs, resulting in a comparative total of more than 16,000 operating days. Combined, NREL has analyzed more than 6 million kilometers of driving and 4 million hours of charging data collected from commercially operating medium-duty electric vehicles in various configurations. In this paper, extensive duty-cycle statistical analyses are performed to examine and characterize common vehicle dynamics trends and relationships based on in-use field data. The results of these analyses statistically define the vehicle dynamic and kinematic requirements for each vehicle, aiding in the selection of representative chassis dynamometer test cycles and the development of custom drive cycles that emulate daily operation. In this paper, the methodology and accompanying results of the duty-cycle statistical analysis are presented and discussed. Results are presented in both graphical and tabular formats illustrating a number of key relationships between parameters observed within the data set that relate to medium duty EVs.

33 ADVANCED PROPULSION SYSTEMS↗

High-Fidelity Analysis of EV Integration on Real Utility Feeders in Colorado

Residential electric vehicle (EV) charging has the potential to alter long-held assumptions on load characteristics impacting distribution grid planning, operations, and design standards. This study identifies analysis and control methods to increase the affordability of residential EV charging both for Xcel Energy and their customers. The project also provides solutions for more reliable grid interconnection that can support a reliable utility business model prepared for increasing EV charging load in the coming years. For this project, we referenced Level 2 alternating current (AC) onboard charging profiles for various vehicle models and high-fidelity charging data collected at the experimental setup established at the EV Research Infrastructure Laboratory at the National Renewable Energy Laboratory (NREL). Next, we developed EV adoption models for 2030 and 2040 for the Boulder and Aurora regions in Colorado. Moreover, we evaluated different smart charging control algorithms and compared their performance. We developed time-of-use (TOU)-based and grid-aware active EV charging control methods and integrated them within the study region to understand field impacts. Diving deeper, we selected 10 feeders in Boulder and Aurora for high-fidelity grid modeling down to the house level. We executed detailed grid analysis comparing the smart charge management (SCM) algorithms we developed. Finally, we created a novel tool, Electric Vehicle Infrastructure--Distribution System Integration Tool (EVI-DiST), to integrate all the approaches in a single software environment to provide easy integration, fast simulation, and detailed evaluation capability for utility engineers and other stakeholders.