Search NASA⌕ Search

SEARCH · Search NASA

Results for “Chemistry, Analytical”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 55 records · Page 3

Detection of dilute organic acids in water by inelastic tunneling spectroscopy

Study of inelastic electron tunneling spectroscopy (IETS) spectra obtained from junctions exposed to dilute solutions of organic molecules in both liquid and vapor phases. The results indicate that it is possible in principle to detect the presence and to measure the concentration of at least some organic molecules in dilute aqueous solution by means of the IETS technique. Some fine points pertaining to the application of this technique are discussed, and it is pointed out that through appropriate refinements IETS may become a valuable tool for analytical water chemistry.

Skarlatos, Y.↗

Experimental and Analytical Studies of Solar System Chemistry

The cosmochemistry research funded by this grant resulted in the publications given in the attached Publication List. The research focused in three areas: (1) Experimental studies of trace element partitioning. (2) Studies of the minor element chemistry and O isotopic compositions of MgAlO4 spinels from Ca-Al-Rich Inclusions in carbonaceous chondrite meteorites, and (3) The abundances and chemical fractionations of Th and U in chondritic meteorites.

Burnett, Donald S.↗

Mass spectrometry

Review of the present status of mass spectrometry in the light of pertinent recent publications spanning the period from December 1971 to January 1974. Following an initial survey of techniques, instruments, and computer applications, a sharp distinction is made between the chemistry of organic (radical-)ions and analytical applications in biorganic chemistry and medicine. The emphasis is on the chemistry of organic (radical-)ions at the expense of inorganic, organometallic, and surface ion chemistry. Biochemistry and medicine are chosen because of their contemporary importance and because of the stupendous contributions of mass spectroscopy to these fields in the past two years. In the review of gas-phase organic ion chemistry, special attention is given to studies making significant contributions to the understanding of ion chemistry.

Burlingame, A. L.↗

Development of static system procedures to study aquatic biofilms and their responses to disinfection and invading species

The microbial ecology facility in the Analytical and Physical Chemistry Branch at Marshall Space Flight Center is tasked with anticipation of potential microbial problems (and opportunities to exploit microorganisms) which may occur in partially closed systems such as space station/vehicles habitats and in water reclamation systems therein, with particular emphasis on the degradation of materials. Within this context, procedures for microbial biofilm research are being developed. Reported here is the development of static system procedures to study aquatic biofilms and their responses to disinfection and invading species. Preliminary investigations have been completed. As procedures are refined, it will be possible to focus more closely on the elucidation of biofilm phenomena.

Smithers, G. A.↗

Mars Hand Lens Imager (MAHLI) Efforts and Observations at the Rocknest Eolian Sand Shadow in Curiosity's Gale Crater Field Site

The Mars Science Laboratory (MSL) mission is focused on assessing the past or present habitability of Mars, through interrogation of environment and environmental records at the Curiosity rover field site in Gale crater. The MSL team has two methods available to collect, process and deliver samples to onboard analytical laboratories, the Chemistry and Mineralogy instrument (CheMin) and the Sample Analysis at Mars (SAM) instrument suite. One approach obtains samples by drilling into a rock, the other uses a scoop to collect loose regolith fines. Scooping was planned to be first method performed on Mars because materials could be readily scooped multiple times and used to remove any remaining, minute terrestrial contaminants from the sample processing system, the Collection and Handling for In-Situ Martian Rock Analysis (CHIMRA). Because of this cleaning effort, the ideal first material to be scooped would consist of fine to very fine sand, like the interior of the Serpent Dune studied by the Mars Exploration Rover (MER) Spirit team in 2004 [1]. The MSL team selected a linear eolian deposit in the lee of a group of cobbles they named Rocknest (Fig. 1) as likely to be similar to Serpent Dune. Following the definitions in Chapter 13 of Bagnold [2], the deposit is termed a sand shadow. The scooping campaign occurred over approximately 6 weeks in October and November 2012. To support these activities, the Mars Hand Lens Imager (MAHLI) acquired images for engineering support/assessment and scientific inquiry.

Edgett, K. S.↗

Mars Hand Lens Imager (MAHLI) efforts and observations at the “Rocknest” Eolian sand shadow in Curiosity’s Gale Crater field site

The Mars Science Laboratory (MSL) mission is focused on assessing the past or present habitability of Mars, through interrogation of environment and environmental records at the Curiosity rover field site in Gale crater. The MSL team has two methods available to collect, process and deliver samples to onboard analytical laboratories, the Chemistry and Mineralogy instrument (CheMin) and the Sample Analysis at Mars (SAM) instrument suite. One approach obtains samples by drilling into a rock, the other uses a scoop to collect loose regolith fines.

Edgett, K. S.↗

Self-Sealing Wet Chemistry Cell for Field Analysis

In most analytical investigations, there is a need to process complex field samples for the unique detection of analytes, especially when detecting low concentration organic molecules that may identify extraterrestrial life. Wet chemistry based instruments are the techniques of choice for most laboratory- based analysis of organic molecules due to several factors including less fragmentation of fragile biomarkers, and ability to concentrate target species resulting in much lower limits of detection. Development of an automated wet chemistry preparation system that can operate autonomously on Earth and is also designed to operate under Martian ambient conditions will demonstrate the technical feasibility of including wet chemistry on future missions. An Automated Sample Processing System (ASPS) has recently been developed that receives fines, extracts organics through solvent extraction, processes the extract by removing non-organic soluble species, and delivers sample to multiple instruments for analysis (including for non-organic soluble species). The key to this system is a sample cell that can autonomously function under field conditions. As a result, a self-sealing sample cell was developed that can autonomously hermetically seal fines and powder into a container, regardless of orientation of the apparatus. The cap is designed with a beveled edge, which allows the cap to be self-righted as the capping motor engages. Each cap consists of a C-clip lock ring below a crucible O-ring that is placed into a groove cut into the sample cap.

Beegle, Luther W.↗

Optimization of Turbine Engine Cycle Analysis with Analytic Derivatives

A new engine cycle analysis tool, called Pycycle, was recently built using the OpenMDAO framework. This tool uses equilibrium chemistry based thermodynamics, and provides analytic derivatives. This allows for stable and efficient use of gradient-based optimization and sensitivity analysis methods on engine cycle models, without requiring the use of finite difference derivative approximation methods. To demonstrate this, a gradient-based design optimization was performed on a multi-point turbofan engine model. Results demonstrate very favorable performance compared to an optimization of an identical model using finite-difference approximated derivatives.

Turbine engine↗

On-Chip Microfluidic Components for In Situ Analysis, Separation, and Detection of Amino Acids

The Astrobiology Analytical Laboratory at GSFC has identified amino acids in meteorites and returned cometary samples by using liquid chromatography-electrospray ionization time-of-flight mass spectrometry (LCMS). These organic species are key markers for life, having the property of chirality that can be used to distinguish biological from non-biological amino acids. One of the critical components in the benchtop instrument is liquid chromatography (LC) analytical column. The commercial LC analytical column is an over- 250-mm-long and 4.6-mm-diameter stainless steel tube filled with functionized microbeads as stationary phase to separate the molecular species based on their chemistry. Miniaturization of this technique for spaceflight is compelling for future payloads for landed missions targeting astrobiology objectives. A commercial liquid chromatography analytical column consists of an inert cylindrical tube filled with a stationary phase, i.e., microbeads, that has been functionalized with a targeted chemistry. When analyte is sent through the column by a pressurized carrier fluid (typically a methanol/ water mixture), compounds are separated in time due to differences in chemical interactions with the stationary phase. Different species of analyte molecules will interact more strongly with the column chemistry, and will therefore take longer to traverse the column. In this way, the column will separate molecular species based on their chemistry. A lab-on-chip liquid analysis tool was developed. The microfluidic analytical column is capable of chromatographically separating biologically relevant classes of molecules based on their chemistry. For this analytical column, fabrication, low leak rate, and stationary phase incorporation of a serpentine microchannel were demonstrated that mimic the dimensions of a commercial LC column within a 5 10 1 mm chip. The microchannel in the chip has a 75- micrometer-diameter oval-shaped cross section. The serpentine microchannel has four different lengths: 40, 60, 80, and 100 mm. Functionized microbeads were filled inside the microchannel to separate molecular species based on their chemistry.

Zheng, Yun↗

Olivine in Martian Meteorite Allan Hills 84001: Evidence for a High-Temperature Origin and Implications for Signs of Life

Olivine from Martian meteorite Allan Hills (ALH) 84001 occurs as clusters within orthopyroxene adjacent to fractures containing disrupted carbonate globules and feldspathic shock glass. The inclusions are irregular in shape and range in size from approx. 40 microns to submicrometer. Some of the inclusions are elongate and boudinage-like. The olivine grains are in sharp contact with the enclosing orthopyroxene and often contain small inclusions of chromite The olivine exhibits a very limited range of composition from Fo(sub 65) to Fo(sub 66) (n = 25). The delta(sup 18)O values of the olivine and orthopyroxene analyzed by ion microprobe range from +4.3 to +5.3% and are indistinguishable from each other within analytical uncertainty. The mineral chemistries, O-isotopic data, and textural relationships indicate that the olivine inclusions were produced at a temperature greater than 800 C. It is unlikely that the olivines formed during the same event that gave rise to the carbonates in ALH 84001, which have more elevated and variable delta(sup 18)O values, and were probably formed from fluids that were not in isotopic equilibrium with the orthopyroxene or olivine The reactions most likely instrumental in the formation of olivine could be either the dehydration of hydrous silicates that formed during carbonate precipitation or the reduction of orthopyroxene and spinel If the olivine was formed by either reaction during a postcarbonate beating event, the implications are profound with regards to the interpretations of McKay et al. Due to the low diffusion rates in carbonates, this rapid, high-temperature event would have resulted in the preservation of the fine-scale carbonate zoning' while partially devolatilizing select carbonate compositions on a submicrometer scale. This may have resulted in the formation of the minute magnetite grains that McKay et al attributed to biogenic activity.

Shearer, C. K.↗

Study of in-situ degradation of thermal control surfaces

Experimental technique used in study of damage mechanism to semiconductor pigments exposed to ultraviolet radiation can be adapted for investigations of surface chemistry and may be used analytically to determine contamination.

Gilligan, J. E.↗

Noble gas component organization in Apollo 14 breccia 14318 I-129 and Pu-244 regolith chronology

Drozd et al. (1972) have first detected the presence of Xe-129 in lunar material. Bernatowicz et al. (1979, 1980) established that this xenon component resides exclusively on grain surfaces and confirmed previous observations that it is less tightly bound than other surface components. The present investigation extends many of the observations made on the basis of a study of the 14301 to 14318, which is the only other lunar regolith breccia for which the isotopic structure of 'parentless xenon' has been accurately resolved. Actually this isotope has two parents, including Pu-244 and I-129, which are both now extinct. Attention is given to the analyzed samples, the employed analytical methods, the petrology and chemistry of the grain size separates, and stepwise heating experiments. On the basis of the obtained results, it is concluded that the I-Pu-Xe system can be used as a chronometer.

Swindle, T. D.↗

Polyatomic molecular Dirac-Hartree-Fock calculations with Gaussian basis sets

Numerical methods have been used successfully in atomic Dirac-Hartree-Fock (DHF) calculations for many years. Some DHF calculations using numerical methods have been done on diatomic molecules, but while these serve a useful purpose for calibration, the computational effort in extending this approach to polyatomic molecules is prohibitive. An alternative more in line with traditional quantum chemistry is to use an analytical basis set expansion of the wave function. This approach fell into disrepute in the early 1980's due to problems with variational collapse and intruder states, but has recently been put on firm theoretical foundations. In particular, the problems of variational collapse are well understood, and prescriptions for avoiding the most serious failures have been developed. Consequently, it is now possible to develop reliable molecular programs using basis set methods. This paper describes such a program and reports results of test calculations to demonstrate the convergence and stability of the method.

Dyall, Kenneth G.↗

International Space Station Potable Water Characterization for 2013

In this post-construction, operational phase of International Space Station (ISS) with an ever-increasing emphasis on its use as a test-bed for future exploration missions, the ISS crews continue to rely on water reclamation systems for the majority of their water needs. The onboard water supplies include U.S. Segment potable water from humidity condensate and urine, Russian Segment potable water from condensate, and ground-supplied potable water, as reserve. In 2013, the cargo returned on the Soyuz 32-35 flights included archival potable water samples collected from Expeditions 34-37. The former Water and Food Analytical Laboratory (now Toxicology and Evironmental Chemistry Laboratory) at the NASA Johnson Space Center continued its long-standing role of performing chemical analyses on ISS return water samples to verify compliance with potable water quality specifications. This paper presents and discusses the analytical results for potable water samples returned from Expeditions 34-37, including a comparison to ISS quality standards. During the summer of 2013, the U.S. Segment potable water experienced a third temporary rise and fall in total organic carbon (TOC) content, as the result of organic contamination breaking through the water system's treatment process. Analytical results for the Expedition 36 archival samples returned on Soyuz 34 confirmed that dimethylsilanediol was once again the responsible contaminant, just as it was for the previous comparable TOC rises in 2010 and 2012. Discussion herein includes the use of the in-flight total organic carbon analyzer (TOCA) as a key monitoring tool for tracking these TOC rises and scheduling appropriate remediation.

Straub, John E., II↗

Summary of Research

In protostellar cores where the dust temperature has been raised above 100K and subsequently allowed to fall below the condensation temperature of methanol, recondensation on to cooling grains removes methanol molecules from the gas at rates.faster (about 1000 times) than those of chemical reactions. Molecular recondensation can have a profound effect on the chemical composition of hot cores. The methanol chemistry of hot cores is solved analytically and the trend in molecule binding energies required is compared with theoretical and experimental values. It is demonstrated, through a model calculation incorporating recondensation, that it yields a consistent explanation of the similarity of the CH3OH , CH3OCH3 and HCOOCH3 abundances measured in G34.3 and W3(H2O). These observations suggest that the latter molecules could not be derived from CH3OH through gas phase reactions. The manner in which molecular recondensation could affect the interpretation of hot core chemistry in general, particularly of organic molecules, is briefly discussed.

dePater, I.↗

Nonequilibrium chemistry boundary layer integral matrix procedure

The development of an analytic procedure for the calculation of nonequilibrium boundary layer flows over surfaces of arbitrary catalycities is described. An existing equilibrium boundary layer integral matrix code was extended to include nonequilibrium chemistry while retaining all of the general boundary condition features built into the original code. For particular application to the pitch-plane of shuttle type vehicles, an approximate procedure was developed to estimate the nonequilibrium and nonisentropic state at the edge of the boundary layer.

Tong, H.↗

Computation of iodine species concentrations in water

During an evaluation of the use of iodine as a water disinfectant and the development of methods for measuring various iodine species in water onboard Space Freedom, it became necessary to compute the concentration of the various species based on equilibrium principles alone. Of particular concern was the case when various amounts of iodine, iodide, strong acid, and strong base are added to water. Such solutions can be used to evaluate the performance of various monitoring methods being considered. The authors of this paper present an overview of aqueous iodine chemistry, a set of nonlinear equations which can be used to model the above case, and a computer program for solving this system of equations using the Newton-Raphson method. The program was validated by comparing results over a range of concentrations and pH values with those previously presented by Gottardi for a given pH. Use of this program indicated that there are multiple roots to many cases and selecting an appropriate initial guess is important. Comparison of program results with laboratory results for the case when only iodine is added to water indicates the program gives high pH values for the iodine concentrations normally used for water disinfection. Extending the model to include the effects of iodate formation results in the computer pH values being closer to those observed, but the model with iodate does not agree well for the case in which base is added in addition to iodine to raise the pH. Potential explanations include failure to obtain equilibrium conditions in the lab, inaccuracies in published values for the equilibrium constants, and inadequate model of iodine chemistry and/or the lack of adequate analytical methods for measuring the various iodine species in water.

Schultz, John R.↗