Hexagonal uniformly redundant arrays for coded-aperture imaging

Uniformly redundant arrays are used in coded-aperture imaging, a technique for forming images without mirrors or lenses. This technique is especially important for the high energy X-ray and gamma-ray region above 20 kev. In this technique, a mask consisting of opaque (closed) and trasparent (open) areas is placed between the photon sources to be imaged and a position sensitive detector or a detector array. Each source casts a shadow pattern of the mask or aperture onto the detector. This shadow pattern may be viewed as an encoded signal for that source direction. If each possible source code is unique, the detected composite of overlapping shadow patterns may be decoded to produce an image of the source distribution.

Finger, M. H.↗

Gamma-ray observations of the Crab Region using a coded-aperture telescope

The region of the Galactic anticenter, including the Crab Nebula, was observed during a balloon flight of the University of New Hampshire Directional Gamma-Ray Telescope employing the coded-aperture imaging technique to image celestial gamma-radiation between 160 keV and 9.3 MeV. The background systematics are treated with a simple and relatively straightforward correction procedure. The results demonstrate that the coded-aperture procedure is a viable approach for imaging not only point sources of radiation, but also extended sources of emission. The results for the Crab's photon spectrum are consistent with a power-law spectrum. Upper limits on the flux levels of line emission at 405 keV and 1050 keV and on the flux from the X-ray binary source A0535 + 26 and diffuse Galactic emission from the anticenter region are derived.

Mcconnell, M. L.↗

Three-Dimensional Event Localization in Bulk Scintillator Crystals Using Optical Coded Apertures

Scintillator-based detectors are among the most commonly used methods for detecting ionizing radiation. Scintillators provide a reliable, cost-effective, and simple way to make large-volume detectors. Furthermore, localizing the position of the interactions in three dimensions within the crystals is useful to a wide array of fields. The most straightforward way of doing this is to pair the crystal with a position-sensitive phototransducer (PT). This allows for measurement of the shape of the light spot at the PT plane. Using this information, various methods exist to localize the gamma-ray interaction in the crystal; however, the position resolution worsens the farther the event occurs from the PT plane. To improve on the localization ability, this work uses an optical coded-aperture shadow mask between the crystal and the PT. In addition, the recorded detector response is used in reconstructing the event over the entire depth of the crystal, and the “sharpest” reconstructed image gives an event's depth. The lateral position is given from the standard coded-aperture image reconstruction. Lastly, experimental results obtained by emulating a 26-mm-thick crystal using a thin 1-mm-thick NaI(Tl) crystal and different amounts of light pipe between the crystal and the PT plane achieved ~ 1 to 2-mm resolution in all three dimensions throughout most of the 26-mm-thick crystal.

36 MATERIALS SCIENCE↗

Hexagonal uniformly redundant arrays for coded-aperture imaging

Uniformly redundant arrays are used in coded-aperture imaging, a technique for forming images without mirrors or lenses. The URAs constructed on hexagonal lattices, are outlined. Details are presented for the construction of a special class of URAs, the skew-Hadamard URAs, which have the following properties: (1) nearly half open and half closed (2) antisymmetric upon rotation by 180 deg except for the central cell and its repetitions. Some of the skew-Hadamard URAs constructed on a hexagonal lattice have additional symmetries. These special URAs that have a hexagonal unit pattern, and are antisymmetric upon rotation by 60 deg, called hexagonal uniformly redundant arrays (HURAs). The HURAs are particularly suited to gamma-ray imaging in high background situations. In a high background situation the best sensitivity is obtained with a half open and half closed mask. The hexagonal symmetry of an HURA is more appropriate for a round position-sensitive detector or a closed-packed array of detectors than a rectangular symmetry.

Finger, M. H.↗

Hexagonal Uniformly Redundant Arrays (HURAs) for scintillator based coded aperture neutron imaging

A series of Monte Carlo simulations have been conducted, making use of the EJ-426 neutron scintillator detector, to investigate the potential of using hexagonal uniformly redundant arrays (HURAs) for scintillator based coded aperture neutron imaging. This type of scintillator material has a low sensitivity to gamma rays, therefore, is of particular use in a system with a source that emits both neutrons and gamma rays. The simulations used an AmBe source, neutron images have been produced using different coded-aperture materials (boron- 10, cadmium-113 and gadolinium-157) and location error has also been estimated. In each case the neutron image clearly shows the location of the source with a relatively small location error. Neutron images with high resolution can be easily used to identify and locate nuclear materials precisely in nuclear security and nuclear decommissioning applications. (authors)

42 ENGINEERING↗

Measurements with Pinhole and Coded Aperture Gamma-Ray Imaging Systems

From a safeguards perspective, gamma-ray imaging has the potential to reduce manpower and cost for effectively locating and monitoring special nuclear material. The purpose of this project was to investigate the performance of pinhole and coded aperture gamma-ray imaging systems at Oak Ridge National Laboratory (ORNL). With the aid of the European Commission Joint Research Centre (JRC), radiometric data will be combined with scans from a three-dimensional design information verification (3D-DIV) system. Measurements were performed at the ORNL Safeguards Laboratory using sources that model holdup in radiological facilities. They showed that for situations with moderate amounts of solid or dense U sources, the coded aperture was able to predict source location and geometry within ~7% of actual values while the pinhole gave a broad representation of source distributions

Raffo-Caiado, Ana Claudia↗

Fast-neutron coded-aperture imaging of special nuclear material configurations

In the past year, a prototype fast-neutron coded-aperture imager has been developed that has sufficient efficiency and resolution to make the counting of warheads for possible future treaty confirmation scenarios via their fission-neutron emissions practical. The imager is constructed from custom-built pixelated liquid scintillator detectors. The liquid scintillator detectors enable neutron-gamma discrimination via pulse shape, and the pixelated construction enables a sufficient number of pixels for imaging in a compact detector with a manageable number of channels of readout electronics. The imager has been used to image neutron sources at ORNL, special nuclear material (SNM) sources at the Idaho National Laboratory (INL) Zero Power Physics Reactor (ZPPR) facility, and neutron source and shielding configurations at Sandia National Laboratories. This paper reports on the design and construction of the imager, characterization measurements with neutron sources at ORNL, and measurements with SNM at the INL ZPPR facility.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

SU-F-I-53: Coded Aperture Coherent Scatter Spectral Imaging of the Breast: A Monte Carlo Evaluation of Absorbed Dose

Purpose: Coherent scatter based imaging has shown improved contrast and molecular specificity over conventional digital mammography however the biological risks have not been quantified due to a lack of accurate information on absorbed dose. This study intends to characterize the dose distribution and average glandular dose from coded aperture coherent scatter spectral imaging of the breast. The dose deposited in the breast from this new diagnostic imaging modality has not yet been quantitatively evaluated. Here, various digitized anthropomorphic phantoms are tested in a Monte Carlo simulation to evaluate the absorbed dose distribution and average glandular dose using clinically feasible scan protocols. Methods: Geant4 Monte Carlo radiation transport simulation software is used to replicate the coded aperture coherent scatter spectral imaging system. Energy sensitive, photon counting detectors are used to characterize the x-ray beam spectra for various imaging protocols. This input spectra is cross-validated with the results from XSPECT, a commercially available application that yields x-ray tube specific spectra for the operating parameters employed. XSPECT is also used to determine the appropriate number of photons emitted per mAs of tube current at a given kVp tube potential. With the implementation of the XCAT digital anthropomorphic breast phantom library, a variety of breast sizes with differing anatomical structure are evaluated. Simulations were performed with and without compression of the breast for dose comparison. Results: Through the Monte Carlo evaluation of a diverse population of breast types imaged under real-world scan conditions, a clinically relevant average glandular dose for this new imaging modality is extrapolated. Conclusion: With access to the physical coherent scatter imaging system used in the simulation, the results of this Monte Carlo study may be used to directly influence the future development of the modality to keep breast dose to a minimum while still maintaining clinically viable image quality.

60 APPLIED LIFE SCIENCES↗

Phase Contrast Imaging with Coded Apertures Using Laboratory-Based X-ray Sources

X-ray phase contrast imaging is a powerful technique that allows detection of changes in the phase of x-ray wavefronts as they pass through a sample. As a result, details not visible in conventional x-ray absorption imaging can be detected. Until recently the majority of applications of phase contrast imaging were at synchrotron facilities due to the availability of their high flux and coherence; however, a number of techniques have appeared recently that allow phase contrast imaging to be performed using laboratory sources. Here we describe a phase contrast imaging technique, developed at University College London, that uses two coded apertures. The x-ray beam is shaped by the pre-sample aperture, and small deviations in the x-ray propagation direction are detected with the help of the detector aperture. In contrast with other methods, it has a much more relaxed requirement for the source size (it works with source sizes up to 100 {mu}m). A working prototype coded-aperture system has been built. An x-ray detector with directly deposited columnar CsI has been used to minimize signal spill-over into neighboring pixels. Phase contrast images obtained with the system have demonstrated its effectiveness for imaging low-absorption materials.

07 ISOTOPE AND RADIATION SOURCES↗

Coded aperture imaging of X-ray and gamma-ray sources

Coded aperture telescopes employing arrays of a small number of discrete detector elements for hard X-rays or gamma-rays are discussed. Aperture patterns are described that permit a unique reconstruction of the image with high contrast, and that exhibit a specific rotational antisymmetry to suppress systematic distortions. It is shown that high flux sensitivity can be achieved in this fashion as well as good angular resolution.

Kroeger, R.↗

Design criteria for small coded aperture masks in gamma-ray astronomy

Most theoretical work on coded aperture masks in X-ray and low-energy gamma-ray astronomy has concentrated on masks with large numbers of elements. For gamma-ray spectrometers in the MeV range, the detector plane usually has only a few discrete elements, so that masks with small numbers of elements are called for. For this case it is feasible to analyze by computer all the possible mask patterns of given dimension to find the ones that best satisfy the desired performance criteria. A particular set of performance criteria for comparing the flux sensitivities, source positioning accuracies and transparencies of different mask patterns is developed. The results of such a computer analysis for masks up to dimension 5 x 5 unit cell are presented and it is concluded that there is a great deal of flexibility in the choice of mask pattern for each dimension.

Sembay, S.↗

SU-C-201-03: Coded Aperture Gamma-Ray Imaging Using Pixelated Semiconductor Detectors

Purpose: Improved localization of gamma-ray emissions from radiotracers is essential to the progress of nuclear medicine. Polaris is a portable, room-temperature operated gamma-ray imaging spectrometer composed of two 3×3 arrays of thick CdZnTe (CZT) detectors, which detect gammas between 30keV and 3MeV with energy resolution of <1% FWHM at 662keV. Compton imaging is used to map out source distributions in 4-pi space; however, is only effective above 300keV where Compton scatter is dominant. This work extends imaging to photoelectric energies (<300keV) using coded aperture imaging (CAI), which is essential for localization of Tc-99m (140keV). Methods: CAI, similar to the pinhole camera, relies on an attenuating mask, with open/closed elements, placed between the source and position-sensitive detectors. Partial attenuation of the source results in a “shadow” or count distribution that closely matches a portion of the mask pattern. Ideally, each source direction corresponds to a unique count distribution. Using backprojection reconstruction, the source direction is determined within the field of view. The knowledge of 3D position of interaction results in improved image quality. Results: Using a single array of detectors, a coded aperture mask, and multiple Co-57 (122keV) point sources, image reconstruction is performed in real-time, on an event-by-event basis, resulting in images with an angular resolution of ∼6 degrees. Although material nonuniformities contribute to image degradation, the superposition of images from individual detectors results in improved SNR. CAI was integrated with Compton imaging for a seamless transition between energy regimes. Conclusion: For the first time, CAI has been applied to thick, 3D position sensitive CZT detectors. Real-time, combined CAI and Compton imaging is performed using two 3×3 detector arrays, resulting in a source distribution in space. This system has been commercialized by H3D, Inc. and is being acquired for various applications worldwide, including proton therapy imaging R&D.

60 APPLIED LIFE SCIENCES↗

Coded-aperture imaging of the Galactic center region at gamma-ray energies

The first coded-aperture images of the Galactic center region at energies above 30 keV have revealed two strong gamma-ray sources. One source has been identified with the X-ray source IE 1740.7 - 2942, located 0.8 deg away from the nucleus. If this source is at the distance of the Galactic center, it is one of the most luminous objects in the galaxy at energies from 35 to 200 keV. The second source is consistent in location with the X-ray source GX 354 + 0 (MXB 1728-34). In addition, gamma-ray flux from the location of GX 1 + 4 was marginally detected at a level consistent with other post-1980 measurements. No significant hard X-ray or gamma-ray flux was detected from the direction of the Galactic nucleus or from the direction of the recently discovered gamma-ray source GRS 1758-258.

Cook, Walter R.↗

Coded aperture imaging with uniformly redundant arrays

The paper discusses uniformly redundant arrays (URA) as applied to coded aperture imaging. The URA system offers the high-transmission characteristics of random arrays as well as a flat sidelobe advantage. The high-transmission yields the imaging of very low-intensity sources and the flat sidelobes provide the suppression of inherent noise which obscures low-contrast sources. Simulations have shown that the URA with shot and background noise produces a better reconstructed object than random arrays without shot or background noise. The URA also offers an arrangement which involves a mosaic of basic URA patterns forming a circular correlation of the object on the picture plane. Thus the information needed to reconstruct the object is contained in an area equal to that of the basic aperture pattern. This smaller required detector is important in applications including X-ray astronomy.

Fenimore, E. E.↗

Accelerator test of the coded aperture mask technique for gamma-ray astronomy

A prototype gamma-ray telescope employing the coded aperture mask technique has been constructed and its response to a point source of 20 MeV gamma-rays has been measured. The point spread function is approximately a Gaussian with a standard deviation of 12 arc minutes. This resolution is consistent with the cell size of the mask used and the spatial resolution of the detector. In the context of the present experiment, the error radius of the source position (90 percent confidence level) is 6.1 arc minutes.

Jenkins, T. L.↗

Dual-sided coded-aperture imager

In a vehicle, a single detector plane simultaneously measures radiation coming through two coded-aperture masks, one on either side of the detector. To determine which side of the vehicle a source is, the two shadow masks are inverses of each other, i.e., one is a mask and the other is the anti-mask. All of the data that is collected is processed through two versions of an image reconstruction algorithm. One treats the data as if it were obtained through the mask, the other as though the data is obtained through the anti-mask.