Search NASA⌕ Search

SEARCH · Search NASA

Results for “Coefficient of variation”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 55 records · Page 3

Precision of Four Acoustic Bone Measurement Devices

Though many studies have quantified the precision of various acoustic bone measurement devices, it is difficult to directly compare the results among the studies, because they used disparate subject pools, did not specify the estimation methodology, or did not use consistent definitions for various precision characteristics. In this study, we used a repeated measures design protocol to directly determine the precision characteristics of four acoustic bone measurement devices: the Mechanical Response Tissue Analyzer (MRTA), the UBA-575+, the SoundScan 2000 (S2000), and the Sahara Ultrasound Done Analyzer. Ten men and ten women were scanned on all four devices by two different operators at five discrete time points: Week 1, Week 2, Week 3, Month 3 and Month 6. The percent coefficient of variation (%CV) and standardized coefficient of variation were computed for the following precision characteristics: interoperator effect, operator-subject interaction, short-term error variance, and long-term drift, The MRTA had high interoperator errors for its ulnar and tibial stiffness measures and a large long-term drift in its tibial stiffness measurement. The UBA-575+ exhibited large short-term error variances and long-term drift for all three of its measurements. The S2000's tibial speed of sound measurement showed a high short-term error variance and a significant operator-subject interaction but very good values ( < 1%) for the other precision characteristics. The Sahara seemed to have the best overall performance, but was hampered by a large %CV for short-term error variance in its broadband ultrasound attenuation measure.

Miller, Christopher↗

Precision of Four Acoustic Bone Measurement Devices

Though many studies have quantified the precision of various acoustic bone measurement devices, it is difficult to directly compare the results among the studies, because they used disparate subject pools, did not specify the estimation methodology, or did not use consistent definitions for various precision characteristics. In this study, we used a repeated measures design protocol to directly determine the precision characteristics of four acoustic bone measurement devices: the Mechanical Response Tissue Analyzer (MRTA), the UBA-575+, the SoundScan 2000 (S2000), and the Sahara Ultrasound Bone Analyzer. Ten men and ten women were scanned on all four devices by two different operators at five discrete time points: Week 1, Week 2, Week 3, Month 3 and Month 6. The percent coefficient of variation (%CV) and standardized coefficient of variation were computed for the following precision characteristics: interoperator effect, operator-subject interaction, short-term error variance, and long-term drift. The MRTA had high interoperator errors for its ulnar and tibial stiffness measures and a large long-term drift in its tibial stiffness measurement. The UBA-575+ exhibited large short-term error variances and long-term drift for all three of its measurements. The S2000's tibial speed of sound measurement showed a high short-term error variance and a significant operator-subject interaction but very good values (less than 1%) for the other precision characteristics. The Sahara seemed to have the best overall performance, but was hampered by a large %CV for short-term error variance in its broadband ultrasound attenuation measure.

Miller, Christopher↗

The near-Earth magnetic field at 1980 determined from MAGSAT data

Data from the MAGSAT spacecraft for November 1979 through April 1980 and from 91 magnetic observatories for 1978 through 1982 are used to derive a spherical harmonic model of the Earth's main magnetic field and its secular variation. Constant coefficients are determined through degree and order 13 and secular variation coefficients through degree and order 10. The first degree external terms and corresponding induced internal terms are given as a function of Dst. Preliminary modeling using separate data sets at dawn and dusk local time showed that the dusk data contains a substantial field contribution from the equatorial electrojet current. The final data set is selected first from dawn data and then augmented by dusk data to achieve a good geographic data distribution for each of three time periods: (1) November/December, 1979; (2) January/February; 1980; (3) March/April, 1980. A correction for the effects of the equatorial electrojet is applied to the dusk data utilized. The solution included calculation of fixed biases, or anomalies, for the observation data.

Langel, R. A.↗

The near-earth magnetic field at 1980 determined from Magsat data

Data from the Magsat spacecraft for November 1979 through April 1980 and from 91 magnetic observatories for 1978 through 1982 are used to derive a spherical harmonic model of the earth's main magnetic field and its secular variation. Constant coefficients are determined through degree and order 13 and secular variation coefficients through degree and order 10. The first degree external terms and corresponding induced internal terms are given as a function of Dst. Preliminary modeling using separate data sets at dawn and dusk local time showed that the dusk data contains a substantial field contribution from the equatorial electrojet current. The final data set is selected first from dawn data and then augmented by dusk data to achieve a good geographic data distribution for each of three time periods: (1) November/December, 1979; (2) January/February, 1980; (3) March/April, 1980. A correction for the effects of the equatorial electrojet is applied to the dusk data utilized. The solution included calculation of fixed biases, or anomalies, for the observation data.

Langel, R. A.↗

Variability of rainfall over small areas

A preliminary investigation was made to determine estimates of the number of raingauges needed in order to measure the variability of rainfall in time and space over small areas (approximately 40 sq miles). The literature on rainfall variability was examined and the types of empirical relationships used to relate rainfall variations to meteorological and catchment-area characteristics were considered. Relations between the coefficient of variation and areal-mean rainfall and area have been used by several investigators. These parameters seemed reasonable ones to use in any future study of rainfall variations. From a knowledge of an appropriate coefficient of variation (determined by the above-mentioned relations) the number rain gauges needed for the precise determination of areal-mean rainfall may be calculated by statistical estimation theory. The number gauges needed to measure the coefficient of variation over a 40 sq miles area, with varying degrees of error, was found to range from 264 (10% error, mean precipitation = 0.1 in) to about 2 (100% error, mean precipitation = 0.1 in).

Runnels, R. C.↗

On the solar cycle variation in the barometer coefficients of high latitude neutron monitors

Evaluation of barometer coefficients of neutron monitors located at high latitudes has been performed by using the results of the spherical harmonic analysis based on the records from around twenty stations for twelve years from January 1966 to December 1977. The average of data at eight stations, where continuous records are available for twelve years, show that the absolute value of barometer coefficient is in positive correlation with the cosmic ray neutron intensity. The variation rate of the barometer coefficient to the cosmic ray neutron intensity is influenced by the changes in the cutoff rigidity and in the primary spectrum.

Kusunose, M.↗

Uncertainty in vertically integrated liquid water content due to radar reflectivity observation error

Radar reflectivity is used to estimate meteorological quantities such as rainfall rate, liquid water content, and the related quantity, vertically integrated liquid (VIL) water content. The estimation of any of these quantities depends on several assumptions related to the characteristics of the physical processes controlling the occurrence and character of water in the atmosphere. Additionally, there are many sources of error associated with radar observations, such as those due to brighthand, hail, and drop size distribution approximations. This work addresses one error of interest, the radar reflectivity observation error; other error sources are assumed to be corrected or negligible. The result is a relationship between the uncertainty in VIL water content and radar reflectivity measurement error. An example application illustrates the estimation of VIL uncertainty from typical radar reflectivity observations and indicates that the coefficient of variation in VIL is much larger than the coefficient of variation in radar reflectivity.

French, Mark N.↗

Prediction of high speed propeller flow fields using a three-dimensional Euler analysis

To overcome the limitations of classical propeller theory, a computer program, NASPROP-E, was developed which solves for the flow field surrounding a multibladed propeller and axisymmetric nacelle combination using a finite difference method. The governing equations are the three dimensional unsteady Euler equations written in a cylindrical coordinate system. They are marched in time until a steady state solution is obtained. The Euler equations require no special treatment to model the blade work vorticity. The equations are solved using an implicit approximate factorization method. Numerical results are presented which have greatly increased the understanding of high speed propeller flow fields. Numerical results for swirl angle downstream of the propeller and propeller power coefficient are higher than experimental results. The radial variation of coefficient are higher than experimental results. The radial variation of swirl angle, however, is in reasonable agreement with the experimental results. The predicted variation of power coefficient with blade angle agrees very well with data.

Bober, L. J.↗

SBASI: Actuated pyrotechnic time delay initiator

A precision pyrotechnic time delay initiator for missile staging was developed and tested. Incorporated in the assembly is a single bridgewire Apollo standard initiator (SBASI) for initiation, a through-bulkhead-initiator to provide isolation of the SBASI output from the delay, the pyrotechnic delay, and an output charge. An attempt was made to control both primary and secondary variables affecting functional performance of the delay initiator. Design and functional limit exploration was performed to establish tolerance levels on manufacturing and assembling operations. The test results demonstrate a 2% coefficient of variation at any one temperature and an overall 2.7% coefficient of variation throughout the temperature range of 30 to 120 F. Tests were conducted at simulated operational altitude from sea level to 200,000 feet.

Salter, S. J.↗

Variation of the drag coefficient and its dependence on sea state

Using a Gill propeller vane anemometer and resistance wave wires over a water column depth of 15 m, simultaneous measurements of the momentum flux and sea surface wave spectra were acquired from the Pisa mast, 28 km offshore in the German Bight during autumn and winter 1979. These data were analyzed to identify the relationship between wind stress and surface waves. It was found that wind stresses for wind speeds above 15 m/s were regularly higher than open ocean wind stresses as reported by Smith (1980) and by Large and Pond (1981) for the same mean wind speed. These results, when described in terms of the drag coefficient, compared closely with the results of Sheppard et al. (1972), who collected surface layer statistics over Lough Neagh, Northern Ireland. After modeling the surface waves of the North Sea as a function of wave saturation (or wave age), it became evident that variations in the magnitude of the drag coefficient could be explained by coincident variations in the surface wave energy spectrum. By applying the wave dependent roughness length model described by Kitaigorodskii (1973), the North Sea drag coefficient was predicted to be larger than drag coefficients reported from the open sea.

Geernaert, G. L.↗

Effects Of Suspension-Line Damping On LADT #3 And Supersonic BLDT Parachute Inflation Dynamics

A two-body computerized mathematical model is used to calculate planar dynamics of the LADT #3 and supersonic BLDT parachute inflations. Results indicate that the calculated loads and motions of the LADT #3 inflation are not affected appreciably by variation in the suspension-line damping coefficient. However, variation of the coefficient results in significant changes in the calculated loads and strain rates of the supersonic BLDT inflation.

Poole, Lamont R.↗

Acute hemodynamic response to weightlessness during parabolic flight

The effect of a short exposure to weightlessness on hemodynamic parameters of humans was investigated in seven subjects flown aboard the KC-135 aircraft. Particular attention is given to the relationships among various hemodynamic responses to hypergravic and hypogravic states, observed for four different postures: semisupine, supine, standing, and sitting. Results are presented on changes in the thoracic fluid index, heart rate, cardiac index, and the coefficient of variation of the R-R intervals. High values of the coefficient of variation were found at the onset of 0-G, suggesting that vagal cardiac neural activity increases in all positions except supine (where a small decrease was registered).

Mukai, Chiaki N.↗

Mean and inter-year variation of growing-season normalized difference vegetation index for the Sahel 1981-1989

Images are presented that show the mean and coefficient of variation of nine years (1981-1989) of NOAA AVHRR normalized difference vegetation index (NDVI) data for the growing season (July-October) in Africa, north of the equator. The variation in the growing season NDVI is represented by the coefficient of variation image that shows the large variation in the Sahelian growing season between years. It is concluded that these images illustrate some aspects of the perspective being brought to regional and continental scale processes by coarse resolution satellite sensors and the potential of these sensors to provide consistent, long-term datasets.

Tucker, C. J.↗

A Comparison of Groundwater Sampling Technologies, Including Passive Diffusion Sampling, for Radionuclide Contamination - 20205

Using traditional high-flow purge methods for long-term water quality monitoring of deep groundwater wells can be expensive, affect contaminant migration, and produce excessive volumes of discharge water that can be difficult to manage. The use of low-flow pumping methods and depth discrete bailers (DDBs) can reduce the cost of sampling deep groundwater wells. In general, using different pumping methods to obtain reproducible and representative groundwater can be challenging. Passive diffusion samplers (PDSs) have successfully been used in long-term monitoring for volatile organic compounds, major ions, and trace-elements, but application has been limited for stable and radioactive isotopes. Beginning in 2018, the United States Geological Survey (USGS) conducted three sampling events to test the ability of PDSs and DDBs to obtain reproducible and representative groundwater samples. The sampled well is completed in a regional, permeable carbonate aquifer and is one in a set of wells that have historically been used for tritium tracer testing. All samples were obtained at 180 m (590 ft) below land surface (bls) in a 13.97 cm (5.5 inch) uncased well that has a total depth of 202 m (662 ft) bls. The first sampling event deployed a regenerated cellulose dialysis membrane (RCDM) PDS for 14 days with deionized water as the blank. The second sampling event deployed a RCDM for 27 days also with deionized water as the blank. The third sampling event deployed a Dual Membrane (DM) PDS for 65 days using a blank of tritium-dead carbonate water. The DM PDS was used to assess the effect of longer term deployment on tritium concentrations and address whether or not the PDSs reached equilibrium with ambient groundwater. The day after each of the three passive samplers were retrieved a DDB was used to obtain discrete non-integrated groundwater samples. For each DDB sampling day, the bailer was lowered into the well 10 consecutive times to determine if the water chemistry changed from the first to the last bailed sample. Quality assurance samples including blanks and duplicates were obtained during all three sampling events. All blank waters had tritium concentrations less than 21±33 pCi/L. Major ion (e.g. calcium, chloride, sodium, and sulfate) results were compared between all samples obtained with RCDM and DDB. Major ion concentrations showed a coefficient of variation of less than 6% between all RCDM and DDB samples; however, the coefficient of variation between the different deployment times and the two different methods for trace-element concentrations was much larger, particularly for manganese (82%), lead (41%), and zinc (33%). Stable isotope values were compared between the RCDM and DDB samples. The DDB sample results all fell within analytical uncertainty and were considered representative of the formation groundwater. The stable isotope values from the RCDM samples indicated that a longer deployment time was necessary to gain equilibrium and to obtain representative groundwater samples. Tritium results from groundwater samples obtained from the RCDM, DM, and DDB indicate that groundwaters obtained with PDSs produced tritium concentrations 2 to 3 times higher (between 1,426 and 3,060±87 pCi/L) than groundwaters obtained with a DDB (479 to 1,219±51 pCi/L). The longer the passive diffusion samplers were deployed, the higher the tritium concentration, suggesting that equilibrium with tritium was not reached within a 27-day deployment. DDB samples showed tritium results declining from the first to the last bailed sample for all three sampling events. This research suggests that tritium results from groundwater samples obtained from PDSs are more reproducible than samples obtained from DDBs. Also, PDSs likely do not accumulate isotopes of water but rather equilibrate with the ambient groundwater. On the other hand, both PDSs and DDBs were able to provide representative groundwater samples for major ions and have the potential to produce representative groundwater samples for stable isotopes of water (δD and δ{sup 18}O). Utilizing the most effective method for sampling groundwater is important for long-term groundwater monitoring. Quantifying the ability of passive diffusion groundwater samplers to obtain representative radioactive chemistry samples will help determine if these methods can be a useful alternative to pumping and purging wells for long-term monitoring. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Chain Pooling modeling selection as developed for the statistical analysis of a rotor burst protection experiment

As many as three iterated statistical model deletion procedures were considered for an experiment. Population model coefficients were chosen to simulate a saturated 2 to the 4th power experiment having an unfavorable distribution of parameter values. Using random number studies, three model selection strategies were developed, namely, (1) a strategy to be used in anticipation of large coefficients of variation, approximately 65 percent, (2) a strategy to be sued in anticipation of small coefficients of variation, 4 percent or less, and (3) a security regret strategy to be used in the absence of such prior knowledge.

Holms, A. G.↗