Search NASA⌕ Search

SEARCH · Search NASA

Results for “Cold Test”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 55 records · Page 3

INFN LASA in-kind contribution to PIP-II

This paper reports the status and recent progress of INFN LASA’s in-kind contribution to the PIP-II project at Fermilab, with updates on key activities and major procurements. Production efforts for the 38 INFN LASA-designed, 5-cell cavities (β=0.61) for the LB650 section of the linac are underway and two pre-series prototypes are being realized as a first step to validate the manufacturing and treatment sequence. Concurrently, preliminary testing on existing prototypes is progressing to gain a deeper understanding of the surface preparation and qualification procedures, including cross-validation at different infrastructures. Series LB650 cavities will be industrially produced and surface-treated to achieve the stringent performance targets, qualified via vertical cold tests at DESY AMTF, and delivered installation-ready for string assembly.

Paparella, Rocco [INFN, Pisa; LASA, Segrate]↗

Flow Measurements in Pressurized Helium Gas Cooling Channels

Production of metastable Technetium-99 (Tc-99m) is vital to the medical imaging community. It is a radioactive tracer that emits gamma rays as it decays and it is these gamma rays that are then detected through imaging. Tc-99m is extracted from the decay of Molybdenum-99 (Mo-99) which has a half-life of about 2-3 days. One method of generating Mo-99 is using accelerator based technology, through the irradiation of Mo-100 using an electron beam. This is part of the NNSA’s mission to produce Mo-99 commercially, within the US, without the use of highly enriched uranium (HEU) in support of nonproliferation and global security. Los Alamos National Laboratory (LANL) is working with NorthStar medical Radioisotopes (NMR) on their efforts to produce Mo-99 from the irradiation of Mo-100 targets. The NMR target consists of an Inconel window that allows the electron beam to penetrate and irradiate a stack of Mo-100 discs. The irradiation process generates large amounts of heat and requires extensive cooling of the Mo-100 targets and target housing using pressurized helium gas. Before beam on target, the design of the target stack and target housing is tested at LANL using laser based diagnostics experiments. We quantify the velocity field of the helium gas around the target housing to estimate whether the cooling provided is sufficient for the design and to validate computational fluid dynamics (CFD) models. Fiber optic imaging is also developed for use during cold testing (without beam on target) as well as during irradiation, to obtain real time information on disc performance.

07 ISOTOPE AND RADIATION SOURCES↗

Silicon wafer fracture stress for tracking sensors in particle physics experiments

For the construction of the ATLAS Inner Tracker strip detector, silicon strip sensor modules are glued directly onto carbon fibre support structures using a soft silicone gel. During tests at temperatures below -35°C, several of the sensors were found to crack due to a mismatch in coefficients of thermal expansion between polyimide circuit boards with copper metal layers (glued onto the sensor) and the silicon sensor itself. While module assembly procedures were developed to minimise variations between modules, cold tests showed a wide range of temperatures at which supposedly comparable modules failed. The observed variance (fracture temperatures between -35°C and -70°C) for supposedly comparable modules suggests an undetected variation between modules suspected to be intrinsic to the silicon wafer itself. Therefore, a test programme was developed to investigate the fracture stress of representative sensor wafer cutoffs. This paper presents results for the fracture stress of silicon sensors used in detector modules.

Detector design and construction technologies and ↗

Results of High Order Modes Spectra Measurements in 1.3 GHz Cavities for LCLS-II

Fermilab recently completed production and testing of 1.3 GHz cryomodules for the LCLS-II project. Each cryomodule consists of eight TESLA-shaped superconducting elliptical cavities equipped with two High Order Mode (HOM) coupler ports. Measurement of the HOM spectrum is part of the incoming quality control of cavities at room temperature and the final qualification cold test of cryomodules at the Cryomodule Test Facility (CMTF). In this paper we describe the procedure for measuring the HOM spectrum along with further data processing. Finally, we present accumulated statistics of individual HOM frequencies and quality factors related to various cavity vendors and discuss the possible contribution of HOMs to heat loads and beam dynamics.

43 PARTICLE ACCELERATORS↗

HOM Spectra Measurements in 1.3 GHz Cavities for LCLS-II

Fermilab recently completed production and testing of 1.3 GHz cryomodules for the LCLS-II project. Each cryomodule consists of eight TESLA-shaped super-conducting elliptical cavities equipped with two High Order Mode (HOM) coupler ports. Measurement of the HOM spectrum is part of the incoming quality control of cavities at room temperature and the final qualification cold test of cryomodules at the Cryomodule Test Facility (CMTF). In this paper we describe the procedure for measuring the HOM spectrum along with further data processing. Finally, we present accumulated statistics of individual HOM frequencies and quality factors related to various cavity vendors and dis-cuss the possible contribution of HOMs to heat loads and beam dynamics.

Lunin, A.↗

Fabrication and Testing of a Prototype RF-Dipole Crabbing Cavity

Crabbing cavities are essential in particle colliders to compensate the luminosity degradation due to beam collision at a crossing angle. The 952.6 MHz 2-cell rf-dipole crabbing cavity system was proposed for the Jef-ferson Lab Electron-Ion Collider to restore the head-on collisions of electron and proton bunches at the interac-tion point. A prototype cavity was designed and devel-oped to demonstrate the performance of multi-cell rf-dipole structures. This paper presents the fabrication pro-cess and cold test results of the first 2-cell rf-dipole proto-type cavity.

43 PARTICLE ACCELERATORS↗

Design and Analysis of the Staggered Double Grating Slow Wave Circuit for 263 GHz Sheet Beam TWT

The complete design process of a high-frequency circuit for a 263 GHz staggered double grating, sheet beam traveling wave tube is presented in this article. Here, this device, for use in a pulsed electron paramagnetic resonance spectrometer instrument, requires >30 dB gain and a 20 GHz bandwidth centered at 263 GHz. In addition to the standard Pierce gain analysis and point by point particle in cell (PIC) simulation, a novel fast pulse response analysis technique was utilized to determine the accurate synchronization voltage and test the ``hot” feature of the high-frequency circuit. Since this new method can evaluate the entire bandwidth in a single simulation, it can significantly reduce the computational resources normally required for the conventional PIC analysis while also illustrating the potential instabilities near the band edge. Good agreement between the fast pulse response and PIC simulation results validate the accuracy of this novel method. According to the analysis results and given the manufacturing limits of nano/micro-computer numerical control (CNC) machining, an appropriate SWS, coupler, and sever designs were chosen to complement the simulated design. Finally, a prototype circuit was manufactured and cold tested to verify the design and inspect the machining tolerances.

42 ENGINEERING↗

Development and First Test of the 15 T Nb$_3$Sn Dipole Demonstrator MDPCT1

Fermilab in the framework of the U.S. Magnet Devel-opment Program (MDP) has developed a Nb$_3$Sn dipole demonstrator for a post-LHC hadron collider. The magnet uses 60-mm aperture 4-layer shell-type graded coils. The cable in the two inner-most layers has 28 strands 1.0 mm in diameter and the cable in the two outermost layers has 40 strands 0.7 mm in diameter. An inno-vative mechanical structure based on aluminum I-clamps and a thick stainless steel skin is used to preload Nb$_3$Sn coils and support large Lorentz forces. The maximum field for this magnet is limited by 15 T due to mechanical considerations. The first magnet assembly was done with lower coil pre-load to achieve 14 T and minimize the risk of coil damage during assembly. This paper describes the magnet design and the details of its assembly procedure, and re-ports the results of its cold tests.

43 PARTICLE ACCELERATORS↗

Window Cooling Studies and Disk Vibration Testing on a Subset of Mo-100 Disks

Production of metastable Technetium-99 (Tc-99m), a radioactive tracer that emits gamma rays, is vital to the medical imaging community. Tc-99m is extracted from the decay of Molybdenum-99 (Mo-99) which has a half-life of about 2-3 days. The work presented in this report is part of the NNSA’s mission to produce Mo-99 commercially, within the US, without the use of highly enriched uranium (HEU) in support of nonproliferation and global security. Los Alamos National Laboratory (LANL) is working with NorthStar Medical Radioisotopes (NMR) on their efforts to produce Mo-99 through the irradiation of Mo-100 targets using an electron beam. The NMR target comprises a stack of approximately 60-70 Mo-100 disks with diameter 24 mm and thickness 0.74 mm held in stainless steel laminations, each separated using 0.25 mm thick stainless-steel spacers. The symmetric target stack is housed in an Inconel vessel with two Inconel windows on either side. Two electron accelerators are used to produce 40 MeV, 3.16 µA electron beams each that penetrate the Inconel windows and irradiate the Mo-100 disks. Approximately 90% of the total 250 kW beam power is deposited in the NMR target during the irradiation process, with a smaller percentage adding up to 2.2 kW of heat deposited on the Inconel window. During irradiation, pressurized helium gas flows through thin gaps between the disks cooling the beam window, target disks, disk laminations and spacers. Both NMR and LANL have found during cold testing of the target system (no heat deposition) that the Mo 100 disks undergo significant mass loss and disk breakage due to vibrations induced by the flowing helium gas. The mass loss is not only undesirable due to monetary loss from reduced final quantities of Mo-99, but also due to the hazards associated with radioactive material trapped in the cooling lines and particle filters. The effect of flow rate and target geometry on the flow induced vibrations need to be quantified, and recommendations provided to minimize this mass loss. LANL has previously also tested NMR’s Inconel beam window by heating the window, while flowing pressurized helium, using the average heat deposited on the window. However, the NMR beam is pulsed with a duty cycle of 12.5%, which introduces oscillation in temperature around the nominal 600 °C steady state value with each pulse. Available fatigue curves for Inconel are few, established for room temperature, and they are based on mechanical strain cycles not thermally induced strain as in the NMR target. The effect of pulsed beam heating on the Inconel window therefore needs to be quantified. This report details the experiments conducted to assess the factors that lead to mass loss in the NMR target disks as well as to understand the effect of a pulsed beam on NMR’s Inconel window. This work describes LANL’s experimental characterization of the flow induced vibrations and disk mass loss in a reduced scale set-up containing 5 to 10 Mo-100 disks. We use high speed imaging, displacement measurements and microphone measurements combined with signal processing to estimate the vibration frequency of each disk. The effect of disk thickness, target fit and duration of testing on the mass loss is described. We find that in the current configuration of NMR targets, the vibrations and mass loss on the first disk are minimized, while those in the adjacent disks are highest. The microphone and high-speed image data show that increased flow rates and increased duration of testing increases vibration frequency and mass loss. The mass loss is due to both disk rotation and back and forth motion. There are visible wear marks on the disks with the highest mass loss. We also note that the current NMR window gap reduces flow induced vibrations compared to the previous smaller gaps. Improved target holders significantly reduce disk mass loss to almost negligible quantities. This work finds that the larger window to first disk gap and improved target holder geometry should allow NMR to successfully conduct irradiations with minimal mass loss. The window tests were conducted to understand the effect of a pulsed beam on both the window longevity and to estimate the window temperature and displacement during pulsing. The experiments presented here were performed at significantly low power, due to the limitations of the induction heating system. The window temperature rose to approximately 73 °C with a significantly reduced power of 45 W without beam pulsing. With a 5 Hz pulse rate, 12.5% duty cycle, the window temperature remained constant at 26 °C. These experiments will be repeated with improved coil geometry and reported in upcoming journal papers.

42 ENGINEERING↗

Design of a finline antenna for current drive in TST-2

A novel “finline” antenna was designed to excite lower-hybrid waves (LHWs) for plasma current drive at 2.45 GHz in the TST-2 spherical tokamak. A periodic fin array acts as a transmission line for electromagnetic surface waves. Cold tests confirmed propagation of the electromagnetic surface wave on the fin array which was dominantly Transverse Magnetic (TM). Unlike the conventional waveguide array “grill” antenna, the finline antenna requires only two ports to feed all the elements, and calculations show that there is little reflection regardless of the plasma conditions in front of the antenna. Characteristics of the microwave transmission on the fin array were investigated using a three-dimensional full-wave simulation and the fin geometry was tuned to achieve the desired refractive index. Coupling to LHWs under typical TST-2 scrape-off layer conditions was confirmed by the simulation. Finally, to demonstrate LHW excitation, the finline antenna was energized in the presence of a plasma generated by another 200 MHz LH antenna. The x-ray radiation showed strong enhancement during the finline antenna pulse which indicated successful generation of fast electrons by LHWs.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Variational, stable, and self-consistent coupling of 3D electromagnetics to 1D transmission lines in the time domain

This work presents a new multiscale method for coupling the 3D Maxwell's equations to the 1D telegrapher's equations. While Maxwell's equations are appropriate for modeling complex electromagnetics in arbitrary-geometry domains, simulation cost for many applications (e.g. pulsed power) can be dramatically reduced by representing less complex transmission line regions of the domain with a 1D model. By assuming a transverse electromagnetic (TEM) ansatz for the solution in a transmission line region, we reduce the Maxwell's equations to the telegrapher's equations. Here, we propose a self-consistent finite element formulation of the fully coupled system that uses boundary integrals to couple between the 3D and 1D domains and supports arbitrary unstructured 3D meshes. Additionally, by using a Lagrange multiplier to enforce continuity at the coupling interface, we allow for an absorbing boundary condition to also be applied to non-TEM modes on this boundary. We demonstrate that this feature reduces non-physical reflection and ringing of non-TEM modes off of the coupling boundary. By employing implicit time integration, we ensure a stable coupling, and we introduce an efficient method for solving the resulting linear systems. We demonstrate the accuracy of the new method on two verification problems, a transient O-wave in a rectilinear prism and a steady-state problem in a coaxial geometry, and show the efficiency and weak scalability of our implementation on a cold test of the Z-machine MITL and post-hole convolute.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Using strong lensing to detect subhaloes with steep inner density profiles

ABSTRACT The inner region of a subhalo’s density distribution is particularly sensitive to dark matter microphysics, with alternative dark matter models leading to both cored and steeply-rising inner density profiles. This work investigates how the lensing signature and detectability of dark matter subhaloes in mock HST-, Euclid-, and JWST-like strong lensing observations depend on the subhalo’s radial density profile, especially with regards to the inner power-law slope, $\beta$. We demonstrate that the minimum subhalo mass detectable along the Einstein ring of a system is strongly dependent on $\beta$. In particular, we show that subhaloes with $\beta = 2.2$ can be detected down to masses over an order-of-magnitude lower than their Navarro–Frenk–White (NFW) counterparts with $\beta = 1$. Importantly, we find that the detectability of subhaloes with steep inner profiles is minimally affected by increasing the complexity of the main lens galaxy’s mass model. This is a notable characteristic of these subhaloes, as those with NFW or shallower profiles become essentially undetectable when multipole perturbations are added to the lens model. The results of this work highlight how the underlying dark matter physics can significantly impact the expected number of subhalo detections from strong gravitational lensing observations. This is important for testing Cold Dark Matter against alternative models, such as Self-Interacting Dark Matter, that predict a diverse range of subhalo inner density profiles.

dark matter↗

First plasma processing trial of a quarter-wave resonator cryomodule at the Facility for Rare Isotope Beams

Studies of plasma processing for reduction of field emission in quarter-wave resonator (QWR) cryomodules are underway at the Facility for Rare Isotope Beams (FRIB), where a total of 104 QWRs are presently in operation. Driving the plasma with a higher-order mode allows for less mismatch at the fundamental power coupler and higher plasma density. The first plasma processing trial for FRIB QWRs in a cryomodule was conducted in January 2024. In-bunker cold tests of the cryomodule showed a significant reduction in field emission x-rays after plasma processing.

Glow & corona plasma discharges↗

Applied Metrology for the Assembly of the Nb 3 Sn MQXFA Quadrupole Magnets for the HL-LHC AUP

The US HL-LHC Accelerator Upgrade Project (AUP) is building Nb 3 Sn quadrupole magnets, called MQXFA, with plans to install 16 of them in the HL-LHC Interaction Regions. Variability in coil size must be dealt with at the assembly level, which requires timely and repeatable measurement of each coil. In this paper we will present the methodology used for coil measurements and the geometrical size data for the coils that have been measured thus far. We will also show the coil measurements of 8 coils before and after cold test. In conclusion, the Leica AT960-MR laser tracker with Spatial Analyzer software acquired to achieve these measurements has been used elsewhere in the project to great effect.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

The Challenges and Solutions of Meeting the Assembly Specifications for the 4.5 m Long MQXFA Magnets for the Hi-Luminosity LHC

The U.S. High-Luminosity LHC Accelerator Upgrade Project (HL-LHC AUP) has, in the recent years, developed assembly specifications for the 4.5 m long MQXFA magnets, which are 150 mm aperture high-field Nb 3 Sn low-β quadrupole magnets that are being built for the CERN Hi-Luminosity LHC (HL-LHC) upgrade. While the specifications were based on lessons learned from the LHC Accelerator Research Program (LARP) effort and the MQXFS and MQXFA prototype magnets, the experience gained from having both MQXFA07 and MQXFA08 magnets not meeting performance specifications during cold testing actually catalyzed a better understanding of the impact of the target assembly specifications and a subsequent refinement of the same. This paper summarizes a body of assembly data from the Pre-Series (MQXFA03-MQXFA07) and Series magnets (MQXFA08-MQXFA11) that have been built to date, and discusses the processes employed to successfully face the challenge of ensuring that the assembly specifications are met for the duration of the project.

43 PARTICLE ACCELERATORS↗

Fabrication of a Nb-Ti Superconducting Closed-Loop Coil for the Next-Generation 45 GHz ECR Ion Source MARS-D

Electron Cyclotron Resonance Ion Sources (ECRISs) that utilize Nb-Ti superconducting coils for 28 GHz frequencies have been operating effectively for over twenty years. However, transitioning to higher frequencies demands stronger magnetic fields, and the conventional racetrack-and-solenoid ECRIS structures have reached their maximum capability with Nb-Ti. To address this, a Mixed Axial and Radial field System Demonstrator (MARS-D) is being developed at Lawrence Berkeley National Laboratory (LBNL). This system features an innovative Closed-Loop Coil (CLC) design that optimizes the use of the conductor fields, enabling the application of Nb-Ti in the next-generation 45 GHz ECRISs. The fabrication of the hexagonal CLC is particularly challenging due to its complex winding path and shape, the stiffness of the Nb-Ti superconducting wire, and the small bending radius. Here, to address these challenges, a series of unique fixtures and tools, as well as a pre-over-bending method, were developed for winding the CLC. To validate the winding fixtures, tools, procedures, and materials used in the coil assembly, a 4-layer practice CLC was wound, epoxy-impregnated, and then cold-tested using liquid nitrogen. The full-size MARS-D CLC is in the process of winding. This paper presents the structure of the MARS-D CLC, the winding fixtures and tools, the winding procedures, the quality control, the impregnation, the test results, and the potential future improvements.

ECR ion sources↗

Novel High-Power Microwave Circulator Employing Circularly Polarized Waves

A novel four-port circulator is presented which uses an inline ferromagnetic element to allow for transmission or reflection depending on the sense of the incident circularly polarized wave. This configuration has been shown to reduce the dependency on ferrite anisotropy and support higher power, low rf loss, operation. An analytic analysis of this device is presented here alongside corroborating cold test data of the first prototype. High-power operation was performed at 2.856 GHz, with input power levels up to 8 MW for 3.5 μs in a pressurized nitrogen environment. The results from this research not only demonstrate ability to eliminate the use of greenhouse insulators, such as SF6, but also provide conceptual groundwork for a new class of ultrahigh power (50 MW+) nonreciprocal networks including circulators, isolators, phase shifters, and rf switches.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Status of MQXFB Quadrupole Magnets for HL-LHC

The MQXFB magnets are superconducting quadrupoles with nominal peak field on the conductor of 11.3 T. With their magnetic length of 7.2 m, they stand as the longest Nb3Sn accelerator magnets designed and manufactured up to now. Together with the companion MQXFA 4.2 m long units, built by the US Accelerator Research Program, they are at the heart of HL-LHC, as they shall replace the inner triplet quadrupoles at either side of the ATLAS and CMS interaction regions of the LHC. This technology has benefited from many years of development, and this specific design was validated with successful short models (MQXFS, 1.2 m long). More recently, several MQXFA magnets were shown to satisfy HL-LHC requirements. In this paper, we report on the cold test results of four MQXFB magnets, focusing on performance, training, behavior after thermal and powering cycles, and field quality. We then provide an update of the overall status, including ongoing verifications of design changes at the level of the coil fabrication.

43 PARTICLE ACCELERATORS↗