Search NASA⌕ Search

SEARCH · Search NASA

Results for “Collector angles”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 55 records · Page 3

Flat-Plate Solar-Collector Performance Evaluation with a Solar Simulator as a Basis for Collector Selection and Performance Prediction

The use of a solar simulator for performance determination permits collector testing under standard conditions of wind, ambient temperature, flow rate and sun. The performance results determined with the simulator have been found to be in good agreement with outdoor performance results. The measured thermal efficiency and evaluation of 23 collectors are reported which differ according to absorber material (copper, aluminum, steel), absorber coating (nonselective black paint, selective copper oxide, selective black nickel, selective black chrome), type of glazing material (glass, Tedlar, Lexan, antireflection glass), the use of honeycomb material and the use of vacuum to prevent thermal convection losses. The collectors were given performance rankings based on noon-hour solar conditions and all-day solar conditions. The determination with the simulator of an all-day collector performance was made possible by tests at different incident angles. The solar performance rankings were made based on whether the collector is to be used for pool heating, hot water, absorption air conditioning, heating, or for a solar Rankine machine.

Simon, F. F.↗

Flat-plate solar-collector performance evaluation with a solar simulator as a basis for collector selection and performance prediction

This paper reports the measured thermal efficiency and evaluation of 23 collectors which differ according to absorber material (copper, aluminum, steel), absorber coating (nonselective black paint, selective copper oxide, selective black nickel, selective black chrome), type of glazing material (glass, Tedlar, Lexan, anti-reflection glass), the use of honeycomb material and the use of vacuum to prevent thermal convection losses. The collectors are given performance rankings based on noon-hour solar conditions and all-day solar conditions. The determination with the simulator of an all-day collector performance is made possible by tests at different incident angles. The solar performance rankings are made based on whether the collector is to be used for pool heating, hot water, absorption air conditioning, heating, or for a solar Rankine machine.

Simon, F. F.↗

Heat Transfer Analysis of Solar Air Heating System for Different Tilt Angles

Solar Air Heater is a simple, cheap and most widely used for various applications such as textile industries, agricultural, desalination and space heating. Generally collectors are tilted so as to absorb maximum radiation, so it is necessary to calculate the optimum tilt angle to maximize the solar radiation falling on the collector area to gain maximum useful energy. The maximum solar radiation can be collected by using a tracking mechanism. Tracking systems are expensive and complicated in construction. The working operation of solar integrated tracking system is difficult. This paper presents the mechanism of evaluating the overall heat transfer coefficient of the solar air-heater at variable intensities and inlet velocities. The experimental setup is integrated with blower at inlet to the solar air heater in order to pump air at different velocities. The work focus on comparative study of solar air heating system for different tilt angles ranging from 250 to 600 and determines the overall heat transfer coefficient so as to find the optimum tilt angle of a solar flat plate collector.

14 SOLAR ENERGY↗

Bastnaesite flotation chemistry issues associated with alkyl phosphate collectors

The hydrophobicity, selectivity, and adsorption state in bastnaesite flotation using alkyl phosphates were examined by contact angle and zeta potential measurements, microflotation and microcalorimetry experiments, as well as density functional theory calculations and molecular dynamics simulations. Here the contact angle and microflotation results show that bastnaesite flotation with alkyl phosphates (lauryl phosphate and 2-ethylhexyl phosphate) is accomplished at a remarkably lower collector concentration. Selective flotation of bastnaesite from calcite with 2-ethylhexyl phosphate increased the bastnaesite grade from 52% to 95% without sacrificing recovery when compared to lauryl phosphate. As expected, the results from density functional theory calculations, together with the microcalorimetry and molecular dynamics simulation results, suggest that the hydrophobic surface state is due to a chemisorbed monolayer of the alkyl phosphate and that the lower reactivity of 2-ethylhexyl phosphate accounts for higher selectivity when compared to results for lauryl phosphate.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

The effect of grid transparency and finite collector size on determining ion temperature and density by the retarding potential analyzer

The analysis of ion data from retarding potential analyzers (RPA's) is generally done under the planar approximation, which assumes that the grid transparency is constant with angle of incidence and that all ions reaching the plane of the collectors are collected. These approximations are not valid for situations in which the ion thermal velocity is comparable to the vehicle velocity, causing ions to enter the RPA with high average transverse velocity. To investigate these effects, the current-voltage curves for H+ at 4000 K were calculated, taking into account the finite collector size and the variation of grid transparency with angle. These curves are then analyzed under the planar approximation. The results show that only small errors in temperature and density are introduced for an RPA with typical dimensions; and that even when the density error is substantial for non-typical dimensions, the temperature error remains minimal.

Troy, B. E., Jr.↗

Experimental analysis of thermal performance of flat plate and evacuated tube solar collectors in stationary standard and daily conditions

New comparative tests on two different types of solar collectors are presented in this paper. A standard glazed flat plate collector and an evacuated tube collector are installed in parallel and tested at the same working conditions; the evacuated collector is a direct flow through type with external compound parabolic concentrator (CPC) reflectors. Efficiency in steady-state and quasi-dynamic conditions is measured following the standard and it is compared with the input/output curves measured for the whole day. The first purpose of the present work is the comparison of results in steady-state and quasi-dynamic test methods both for flat plate and evacuated tube collectors. Besides this, the objective is to characterize and to compare the daily energy performance of these two types of collectors. An effective mean for describing and analyzing the daily performance is the so called input/output diagram, in which the collected solar energy is plotted against the daily incident solar radiation. Test runs have been performed in several conditions to reproduce different conventional uses (hot water, space heating, solar cooling). Results are also presented in terms of daily efficiency versus daily average reduced temperature difference: this allows to represent the comparative characteristics of the two collectors when operating under variable conditions, especially with wide range of incidence angles. (author)

14 SOLAR ENERGY↗

Comparison of indoor-outdoor thermal performance for the Sunpak evacuated tube liquid collector

Performance data for current Sunpak production collectors is presented. The effects of an improved manifold are seen from the test results. The test results show excellent correlation between the solar simulator derived test results and outdoor test results. Also, because of different incident angle modifiers, the all-day efficiency of this collector with a diffuse reflector is comparable to the performance with the standard shaped specular reflector.

Source record↗

Aerodynamic Analysis of Wind Loading on Parabolic Trough Collectors Using High-Fidelity CFD Modeling

Wind loading on parabolic solar collector support structures is the key driver for material costs. As identified by NREL's CSP Best Practices project [1], ability to predict wind-loading in deep-arrays and the impact of edge effects has potential to decrease levelized cost of electricity (LCoE) by 15%. In this study, we present a high-fidelity computational model that can model the flow around deep arrays of parabolic troughs under varying turbulent inflow conditions. Ability to accurately reproduce atmospheric boundary layer (ABL) profiles is first demonstrated through Large Eddy Simulation (LES) simulations and compared against wind tunnel measurements. Thereafter, unsteady turbulent flow past single row and six row configurations is computed using hybrid RANS/LES simulations. Investigations of wind loading, through parametric tilt angle variations of single row and on waked collectors in six-row configuration, are used to highlight design considerations for parabolic troughs only possible through high-fidelity unsteady calculations.

aerodynamics↗

Summer performance results obtained from simultaneously testing ten solar collectors outdoors

Ten solar collectors were simultaneously tested outdoors. Efficiency data were correlated using a method that separates solar variables (flux, incident angle) from the desired performance parameters (heat loss, absorbtance, transmittance) which are unique to a given collector design. Tests were conducted on both clear and moderately cloudy days. Correlating data in the above manner, a 2-glass, black paint collector exhibited a decrease in efficiency of 5 percentage points relative to the baseline data for an exposure time of 2 years, 4 months. Condensation on the collector glazing was thought to be a contributing factor in this efficiency change.

Miller, D. R.↗

Development of Operando Nuclear Magnetic Resonance Capabilities for Solid-State Battery Research

Mechanistic information regarding solid-solid interfaces in solid-state batteries remains elusive as its observation requires a non-destructive operando technique. Such a technique does not currently exist. Solid-state nuclear magnetic resonance (NMR) is uniquely suited to address this challenge as it is sensitive to chemistry, structure, and dynamics and can measure buried interfaces. However solid-state NMR requires high speed spinning of the sample at the ‘magic angle’ (MAS) to obtain adequate resolution. The metallic current collectors in a battery are detrimental to spinning in magnetic fields as they generate eddy currents which prevent spinning and dampen the NMR signal. Furthermore, the spinning nature of the MAS NMR experiment requires a wireless means of charging for operando capabilities. These challenges were addressed in this research and operando MAS NMR enabled by optical wireless charging was demonstrated. By limiting the size of the metallic components, we were able to spin a sample holder with electrical leads and a solid-state battery up to a few kilohertz, fast enough for high-resolution NMR. We achieved wireless charging by attaching a photovoltaic cell to the head of the NMR rotor and used a laser to transmit power to the photovoltaic cell. Demonstration of the optical wireless charging was performed by polarizing a liquid electrolyte during an operando MAS NMR measurement. This novel capability is a transformative technique for investigating the mechanistic electrochemical processes in solid-state samples.

25 ENERGY STORAGE↗

Experimental studies on solar flat plate collector with internally grooved tubes using aqueous ethylene glycol

In order to cope up with the increase in energy demand and decline in fossil fuels, it has become imperative to use renewable resources efficiently. Among these renewable resources, solar thermal energy is abundant in nature. Solar water heating systems are one of the most important applications of solar thermal energy. Providing internal fins to absorber tube is the technique to improve heat transfer augmentation. Hence in the present study, experiments were performed on solar flat plate collector with different cross section of absorber tubes (plain tube and internally grooved tubes with different helix angles) and by varying the mass flow rates of the working fluids. This study reports the experimental results of flat plate collector, where the working fluid is water and aqueous ethylene glycol (50 : 50). Temperature profile of grooved absorber tube will be compared with plain tube. Since conversion efficiency of solar devices is low, the present study mainly focuses on improving the efficiency of solar flat plate collector.

14 SOLAR ENERGY↗

Beam impingement angle effects on secondary electron emission characteristics of textured pyrolytic graphite

Experimentally determined values of true secondary electron emission and relative values of reflected primary electron yield for untreated and ion-textured pyrolytic graphite over a range of primary electron energy levels and electron beam impingement angles are presented. Information required to develop high efficiency multistage depressed collectors (MDC's) for microwave amplifier traveling-wave tubes for space communication and aircraft applications is provided. To attain the highest possible MDC efficiencies, the electrode surfaces must have low secondary electron emission characteristics. Pyrolytic graphite, a chemically vapor-deposited material, is a particularly promising candidate for this application. The pyrolytic graphite surfaces studied were tested over a range of primary electron beam energies and beam impingement angles from 200 to 2000 eV and direct (0 deg) to near-grazing angles (85 deg), respectively. Surfaces both parallel to and normal to the planes of material deposition were examined. The true secondary electron emission and reflected primary electron yield characteristics of the pyrolytic graphite surfaces are compared to those of sooted control surfaces.

Curren, A. N.↗

Concentrating solar collector-performance tests

Report summarizes test results from evaluation of concentrating solar collector thermal performance, from transient behavior, and incident-of-angle behavior. Tests were conducted using National Bureau of Standards recommedations and specifications.

Source record↗

The Effect on Airplane Performance of the Factors That Must Be Considered in Applying Low-Drag Cowling to Radial Engines

This report presents the results of flight tests with three different airplanes using several types of low-drag cowling for radial air-cooled engines. The greater part of the tests were made with a Curtiss XF7Cc-1 (Sea Hawk) with a 410 horsepower. Wasp engine, using three fuselage nose shapes and six types of outer cowling. The six cowlings were: a narrow ring, a wide ring, a wide cowling similar in the original NACA cowling, a thick ring incorporating an exhaust collector, a single-surface cowling shaped like the outer surface of the exhaust-collector cowling, and polygon-ring cowling, of which the angle of the straight sections with the thrust line could be varied over a wide range.

Mcavoy, William H↗

Performance of Compressor of XJ-41-V Turbojet Engine: Performance Analysis Over Range of Compressor Speeds from 5000 to 10,000 RPM - 4

An investigation of the XJ-41-V turbojet-engine compressor was conducted to determine the performance of the compressor and to obtain fundamental information on the aerodynamic problems associated with large centrifugal-type compressors. The results of the research conducted on the original compressor indicated the compressor would not meet the desired engine-design air-flow requirements because of an air-flow restriction in the vaned collector. The compressor air-flow choking point occurred near the entrance to the vaned-collector passage and was instigated by a poor mass-flow distribution at the vane entrance and from relatively large negative angles of attack of the air stream along the entrance edges of the vanes at the outer passage wall and large positive angles of attack at the inner passage wall. As a result of the analysis, a design change of the vaned collector entrance is recommended for improving the maximum flow capacity of the compressor.

John W R Creagh↗

New adaptive method to optimize the secondary reflector of linear Fresnel collectors

Performance of linear Fresnel collectors may largely depend on the secondary-reflector profile design when small-aperture absorbers are used. Optimization of the secondary-reflector profile is an extremely challenging task because there is no established theory to ensure superior performance of derived profiles. In this work, an innovative optimization method is proposed to optimize the secondary-reflector profile of a generic linear Fresnel configuration. The method correctly and accurately captures impacts of both geometric and optical aspects of a linear Fresnel collector to secondary-reflector design. The proposed method is an adaptive approach that does not assume a secondary shape of any particular form, but rather, starts at a single edge point and adaptively constructs the next surface point to maximize the reflected power to be reflected to absorber(s). As a test case, the proposed optimization method is applied to an industrial linear Fresnel configuration, and the results show that the derived optimal secondary reflector is able to redirect more than 90% of the power to the absorber in a wide range of incidence angles. Here, the proposed method can be naturally extended to other types of solar collectors as well, and it will be a valuable tool for solar-collector designs with a secondary reflector.

14 SOLAR ENERGY↗