Search NASA⌕ Search

SEARCH · Search NASA

Results for “Commercialization”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 55 records · Page 3

Enabling reliability assessments of pre-commercial perovskite photovoltaics with lessons learned from industrial standards [Enabling reliability of pre-commercial perovskite photovoltaics with lessons learned from industrial standards]

Here, photovoltaic modules are expected to operate in the field for more than 25 years, so reliability assessment is critical for the commercialization of new photovoltaic technologies. In early development stages, understanding and addressing the device degradation mechanisms are the priorities. However, any technology targeting large-scale deployment must eventually pass industry-standard qualification tests and undergo reliability testing to validate the module lifetime. In this Perspective, we review the methodologies used to assess the reliability of established photovoltaics technologies and to develop standardized qualification tests. We present the stress factors and stress levels for degradation mechanisms currently identified in pre-commercial perovskite devices, along with engineering concepts for mitigation of those degradation modes. Recommendations for complete and transparent reporting of stability tests are given, to facilitate future inter-laboratory comparisons and to further the understanding of field-relevant degradation mechanisms, which will benefit the development of accelerated stress tests.

14 SOLAR ENERGY↗

High-performing commercial Fe–N–C cathode electrocatalyst for anion-exchange membrane fuel cells

Here, to reduce the cost of fuel cell stacks and systems, it is important to create commercial catalysts that are free of platinum group metals (PGMs). To do this, such catalysts must have very high activity, but also have the correct microstructure to facilitate the transport of reactants and products. Here, we show a high-performing commercial oxygen reduction catalyst that was specifically developed for operation in alkaline media and is demonstrated in the cathode of operating anion-exchange membrane fuel cells (AEMFCs). With H 2 /O 2 reacting gases, AEMFCs made with Fe–N–C cathodes achieved a peak power density exceeding 2 W cm –2 (>1 W cm –2 with H 2 /air) and operated with very good voltage durability for more than 150 h. These AEMFCs also realized an iR-corrected current density at 0.9 V of 100 mA cm –2 . Finally, in a second configuration, Fe–N–C cathodes paired with low-loading PtRu/C anodes (0.125 mg PtRu per cm 2 , 0.08 mg Pt per cm 2 ) demonstrated a specific power of 10.4 W per mg PGM (16.25 W per mg Pt).

25 ENERGY STORAGE↗

Comparative Study of DC and AC Microgrids in Commercial Buildings Across Different Climates and Operating Profiles

Bosch has developed and demonstrated a novel direct current (DC) microgrid system that maximizes the efficiency of locally generated photovoltaic energy while offering high reliability, safety, redundancy, and reduced cost compared to equivalent alternating current (AC) systems. Several demonstration projects validating the system feasibility and expected efficiency gains have been completed and additional ones are in progress. This paper gives an overview of the Bosch DC microgrid system and presents key results from a large simulation study done to estimate the energy savings of the Bosch DC microgrid over conventional AC systems. The study examined the system performance in locations across the United States for several commercial building types and operating profiles. It found that the Bosch DC microgrid uses generated PV energy 6%-8% more efficiently than traditional AC systems.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Polarization Type Potential Induced Degradation under Positive Bias in a Commercial PERC Module: Preprint

Potential induced degradation of the polarization type (PID-p) can reduce module performance in a relatively short period of time. PID-p can occur at both voltage polarities, but most studies are focused on degradation under a negative bias. This paper uses commercial bifacial passivated emitter and rear contact (PERC) cells within a monofacial glass-backsheet module construction to evaluate the impact of PID-p under a positive bias on the front side. Using the aluminum-foil (Al-foil) method, the module was stressed for PID in an environmental chamber. After the stress, the maximum power (Pmax) showed a decline of 3.1% at 1000 W/m2 and 6.2% at 200 W/m2. Recovery under light was also investigated. Complete recovery was observed at high irradiance, while a partial recovery was seen at lower irradiance. The outcomes of this study can help in understanding PID-p degradation under a positive bias and its recovery under the light.

PERC↗

Prospects for in vivo estimation of photon linear attenuation coefficients using postprocessing dual-energy CT imaging on a commercial scanner: Comparison of analytic and polyenergetic statistical reconstruction algorithms

Purpose: Accurate patient-specific photon cross-section information is needed to support more accurate model-based dose calculation for low energy photon-emitting modalities in medicine such as brachytherapy and kilovoltage x-ray imaging procedures. A postprocessing dual-energy CT (pDECT) technique for noninvasivein vivo estimation of photon linear attenuation coefficients has been experimentally implemented on a commercial CT scanner and its accuracy assessed in idealized phantom geometries. Methods: Eight test materials of known composition and density were used to compare pDECT-estimated linear attenuation coefficients to NIST reference values over an energy range from 10 keV to 1 MeV. As statistical image reconstruction (SIR) has been shown to reconstruct images with less random and systematic error than conventional filtered backprojection (FBP), the pDECT technique was implemented with both an in-house polyenergetic SIR algorithm, alternating minimization (AM), as well as a conventional FBP reconstruction algorithm. Improvement from increased spectral separation was also investigated by filtering the high-energy beam with an additional 0.5 mm of tin. The law of propagated uncertainty was employed to assess the sensitivity of the pDECT process to errors in reconstructed images. Results: Mean pDECT-estimated linear attenuation coefficients for the eight test materials agreed within 1% of NIST reference values for energies from 1 MeV down to 30 keV, with mean errors rising to between 3% and 6% at 10 keV, indicating that the method is unbiased when measurement and calibration phantom geometries are matched. Reconstruction with FBP and AM algorithms conferred similar mean pDECT accuracy. However, single-voxel pDECT estimates reconstructed on a 1 × 1 × 3 mm{sup 3} grid are shown to be highly sensitive to reconstructed image uncertainty; in some cases pDECT attenuation coefficient estimates exhibited standard deviations on the order of 20% around the mean. Reconstruction with the statistical AM algorithm led to standard deviations roughly 40% to 60% less than FBP reconstruction. Additional tin filtration of the high energy beam exhibits similar pDECT estimation accuracy as the unfiltered beam, even when scanning with only 25% of the dose. Using the law of propagated uncertainty, low Z materials are found to be more sensitive to image reconstruction errors than high Z materials. Furthermore, it is estimated that reconstructed CT image uncertainty must be limited to less than 0.25% to achieve a target linear-attenuation coefficient estimation uncertainty of 3% at 28 keV. Conclusions: That pDECT supports mean linear attenuation coefficient measurement accuracies of 1% of reference values for energies greater than 30 keV is encouraging. However, the sensitivity of the pDECT measurements to noise and systematic errors in reconstructed CT images warrants further investigation in more complex phantom geometries. The investigated statistical reconstruction algorithm, AM, reduced random measurement uncertainty relative to FBP owing to improved noise performance. These early results also support efforts to increase DE spectral separation, which can further reduce the pDECT sensitivity to measurement uncertainty.

61 RADIATION PROTECTION AND DOSIMETRY↗

The impact of low-Z and high-Z metal implants in IMRT: A Monte Carlo study of dose inaccuracies in commercial dose algorithms

Purpose: The aim of the study was to evaluate the dosimetric impact of low-Z and high-Z metallic implants on IMRT plans. Methods: Computed tomography (CT) scans of three patients were analyzed to study effects due to the presence of Titanium (low-Z), Platinum and Gold (high-Z) inserts. To eliminate artifacts in CT images, a sinogram-based metal artifact reduction algorithm was applied. IMRT dose calculations were performed on both the uncorrected and corrected images using a commercial planning system (convolution/superposition algorithm) and an in-house Monte Carlo platform. Dose differences between uncorrected and corrected datasets were computed and analyzed using gamma index (Pγ{sub <1}) and setting 2 mm and 2% as distance to agreement and dose difference criteria, respectively. Beam specific depth dose profiles across the metal were also examined. Results: Dose discrepancies between corrected and uncorrected datasets were not significant for low-Z material. High-Z materials caused under-dosage of 20%–25% in the region surrounding the metal and over dosage of 10%–15% downstream of the hardware. Gamma index test yielded Pγ{sub <1}>99% for all low-Z cases; while for high-Z cases it returned 91% < Pγ{sub <1}< 99%. Analysis of the depth dose curve of a single beam for low-Z cases revealed that, although the dose attenuation is altered inside the metal, it does not differ downstream of the insert. However, for high-Z metal implants the dose is increased up to 10%–12% around the insert. In addition, Monte Carlo method was more sensitive to the presence of metal inserts than superposition/convolution algorithm. Conclusions: The reduction in terms of dose of metal artifacts in CT images is relevant for high-Z implants. In this case, dose distribution should be calculated using Monte Carlo algorithms, given their superior accuracy in dose modeling in and around the metal. In addition, the knowledge of the composition of metal inserts improves the accuracy of the Monte Carlo dose calculation significantly.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Commercial cyclotrons. Part I: Commercial cyclotrons in the energy range 10–30 MeV for isotope production

A survey of commercial cyclotrons for production of medical and industrial isotopes is presented. Compact isochronous cyclotrons which accelerate negative hydrogen ions in the energy range 10–30 MeV have been widely used over the last 25 years for production of medical isotopes and other applications. Different cyclotron models for the energy range 10–12 MeV with moderate beam intensity are used for production of {sup 11}C, {sup 13}N, {sup 15}O, and {sup 18}F isotopes widely applied in positron emission tomography. Commercial cyclotrons with high beam intensity are available on the market for production of most medical and industrial isotopes. In this work, the physical and technical parameters of different models are compared. Possibilities of improving performance and increasing intensity of H{sup −} beams up to 2–3 mA are discussed.

43 PARTICLE ACCELERATORS↗

Data for Optimization of Pre-Commercial Enzymes Dosage for a Potential Lignocellulosic Biorefinery

Lignocellulolytic enzymes remain one of the primary cost constraints in second-generation (2G) ethanol biorefineries. Achieving efficient hydrolysis of structural carbohydrates with minimal enzyme dosage, maintaining slurry fermentability for industrially relevant ethanol titers, and maximizing ethanol yield per ton of biomass are among the major challenges in 2G processes. In this study, we optimized the dosages of pre-commercial cellulase (NS22257) and hemicellulase (NS22244) on pilot-scale, hydrothermally pretreated lignocellulosic substrates. Enzyme dosages were evaluated at three levels: 20 mg of cellulase with 7.25 mg of hemicellulase (ED-1), 40 mg with 14.5 mg (ED-2), and 60 mg with 21.75 mg (ED-3). As expected, the highest sugar yields were obtained with ED-3; however, for sweet sorghum, oilcane, and miscanthus, sugar yields from ED-2 and ED-3 were not significantly different (p < 0.05). For example, sweet sorghum produced 123.78 ± 1.54 g L−1 and 125.76 ± 0.46 g L−1 of total sugars (glucose and xylose) with ED-2 and ED-3, respectively. Although energycane exhibited a statistically significant difference between ED-2 and ED-3, the incremental gain with ED-3 was modest, increasing sugar release by only 9.02 g L−1 relative to ED-2. Importantly, ED-1 resulted in sugar yields of 88.88 ± 3.64 to 106.86 ± 1.21 g L−1, sufficient to achieve ethanol titers ≥40 g L−1, the threshold required for industrial relevance. A semi-integrated bioprocess validated this outcome, producing 42.09 ± 2.38 g L−1 ethanol and an estimated yield of 213.38 L of ethanol per dry ton of pretreated biomass, requiring only 20.83 L of cellulase and 6.25 L of hemicellulase per ton. Remarkably, these enzyme dosages were approximately tenfold lower than those reported in prior studies.

Energycane↗

Use of Commercial Electrical, Electronic and Electromechanical (EEE) Parts in NASA's Commercial Crew Program (CCP)

NASA's Commercial Crew and Cargo Program (CCP) is stimulating efforts within the private sector to develop and demonstrate safe, reliable, and cost-effective space transportation capabilities. One initiative involves investigating the use of commercial electronic parts. NASA's CCP asked the NASA Engineering and Safety Center (NESC) to collect data to help frame the technical, cost, and schedule risk trades associated with electrical, electronic and electromechanical (EEE) parts selection and specifically expressed desire of some of the CCP partners to employ EEE parts of a lower grade than traditionally used in most NASA safety-critical applications. This document contains the outcome from the NESC's review and analyses.

Gonzalex, Oscar↗

ESO Commercial Microgravity Case Study 1: Novice Commercial Users (Medical) Vivo Biosciences Inc. - A Small Business Perspective

This case study was conducted in FY 2013 by the Emerging Space Office (ESO) to begin characterizing the kinds of opportunities and challenges encountered by small high-tech businesses who have never done RD in space and who serve terrestrial versus space markets, but who have legitimate business reasons for considering space research and development for generating novel or improved products. Vivo Biosciences Inc. (VBI) is an award winning company with a customer base that includes major pharmaceutical companies. However, despite a continuing series of successes, VBI believes that they are about at the limit of the performance their product can achieve on Earth and gravity is the problem. This Case Study documented VBI's experience as the novice company attempted its first steps in the process of conducting research and development in space. The report presents insights applicable to commercial suppliers of microgravity services as well as ISS support of new commercial users, especially small businesses interested in using space for product development.

Harper, Lynn D.↗

Evaluation of a commercially available passively Q-switched Nd:YAG laser with LiF:F-2(-) saturable absorber for laser-induced breakdown spectroscopy

Interest in passively Q-switched microchip lasers as a means for miniaturization of laser-induced breakdown spectroscopy (LIBS) apparatus has rapidly grown in the last years. To explore the possibility of using a comparatively UV-Vis transparent absorber, we herein present the first report on the evaluation of a commercially available flash lamp-pumped passively Q-switched Nd:YAG laser with LiF:F 2 - saturable absorber as an excitation source in LIBS. Quantitative measurements of barium, strontium, rubidium and lithium in granite, rhyolite, basalt and syenite whole-rock glass samples were performed. Ablation craters produced on a rock glass sample were characterized using a computerized X-ray tomography. Using a gated intensified benchtop spectrometer, limits of detection of 0.97, 23, 37, and 144 ppm were obtained for Li, Sr, Rb, and Ba, respectively. Finally, we discuss the advantages of using such a laser unit for LIBS applications in terms of ablation efficiency, analytical performances, output energy, and standoff capabilities.

36 MATERIALS SCIENCE↗

On filament structure and propagation within a commercial plasma globe

The filamentary discharge seen within commercial plasma globes is commonly enjoyed yet not well understood. Here, we investigate the discharge properties of a plasma globe using a variable high voltage amplifier. We find that increasing voltage magnitude increases the number of filaments while leaving their individual structure basically unchanged, a result typical of dielectric barrier discharges. The frequency of the voltage also affects filament population but more significantly changes filament structure, with more diffuse filaments seen at lower frequencies. Voltage polarity is observed to be important, especially at lower frequencies, where for negative-gradient voltages the discharge is more diffuse, not filamentary. At late stages of the discharge circular structures appear and expand on the glass boundaries. We find no trend of discharge speed with respect to voltage variables, though this may be due to manufacturer sample-to-sample variation. Each voltage cycle the discharge expands outward at ∼10–15 km/s, a speed significantly higher than the estimated electron drift yet considerably lower than that observed for most streamers. We discuss the physics of these observations and their relation to similar discharges that can be found within nature and industry.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗