Search NASA⌕ Search

SEARCH · Search NASA

Results for “Compliance Study”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 55 records · Page 3

The relationship of compliance changes during fatigue loading to the fracture of composite materials

The study outlined here is based on measurements of the change in engineering stiffness values induced by the development of damage in composite laminates during quasi-static or cyclic (fatigue) loading. These changes are found to be related to the individual details of the damage events in the laminates, as well as to the residual strength and life of the laminates. It is believed that the stiffness changes can also be used to relate composite material behavior under cyclic loading to its behavior under quasi-static loading. Results are presented for both notched and unnotched laminates. Compliance changes are found to be caused by damage events that bring about both global and local redistributions of stress. It is also found that the redistributions of stress determine the residual strength of the laminate. The quantitative link between compliance changes and fracture strength is the mechanics of the internal stress redistributions.

Reifsnider, K. L.↗

Analysis and test of a space truss foldable hinge

The Mini-Mast is a 20-meter long deployable, three-longeron, truss-beam being used to develop analytical and experimental methods for predicting the physical behavior of large space structures. With 57 corner-body hinges and 54 mid-body hinges, the Mini-Mast is highly joint-dominated, necessitating inclusion of the compliance of the joints in analytical models. This study demonstrates an approach for calculating the stiffness properties of a complicated hinge called the mid-body hinge. The process includes detailed modeling with solid-body modeling software and the use of finite element analysis. Load-deflection tests were conducted to determine the axial stiffness of the mid-body hinge. This is compared to the axial stiffness value determined from a finite element analysis.

Nimmo, N. A.↗

Experimental study of trajectory planning and control of a high precision robot manipulator

The kinematic and trajectory planning is presented for a 6 DOF end-effector whose design was based on the Stewart Platform mechanism. The end-effector was used as a testbed for studying robotic assembly of NASA hardware with passive compliance. Vector analysis was employed to derive a closed-form solution for the end-effector inverse kinematic transformation. A computationally efficient numerical solution was obtained for the end-effector forward kinematic transformation using Newton-Raphson method. Three trajectory planning schemes, two for fine motion and one for gross motion, were developed for the end-effector. Experiments conducted to evaluate the performance of the trajectory planning schemes showed excellent tracking quality with minimal errors. Current activities focus on implementing the developed trajectory planning schemes on mating and demating space-rated connectors and using the compliant platform to acquire forces/torques applied on the end-effector during the assembly task.

Nguyen, Charles C.↗

Cardiovascular Deconditioning and Venous Air Embolism in Simulated Microgravity in the Rat

Astronauts conducting extravehicular activities undergo decompression to a lower ambient pressure, potentially resulting in gas bubble formation within the tissues and venous circulation. Additionally, exposure to microgravity produces fluid shifts within the body leading to cardiovascular deconditioning. A lower incidence of decompression illness in actual spaceflight compared with that in ground-based altitude chamber flights suggests that there is a possible interaction between microgravity exposure and decompression illness. The purpose of this study was to evaluate the cardiovascular and pulmonary effects of simulated hypobaric decompression stress using a tail suspension (head-down tilt) model of microgravity to produce the fluid shifts associated with weightlessness in conscious, chronically instrumented rats. Venous bubble formation resulting from altitude decompression illness was simulated by a 3-h intravenous air infusion. Cardiovascular deconditioning was simulated by 96 h of head-down tilt. Heart rate, mean arterial blood pressure, central venous pressure, left ventricular wall thickening and cardiac output were continuously recorded. Lung studies were performed to evaluate edema formation and compliance measurement. Blood and pleural fluid were examined for changes in white cell counts and protein concentration. Our data demonstrated that in tail-suspended rats subjected to venous air infusions, there was a reduction in pulmonary edema formation and less of a decrease in cardiac output than occurred following venous air infusion alone. Mean arterial blood pressure and myocardial wall thickening fractions were unchanged with either tail-suspension or venous air infusion. Heart rate decreased in both conditions while systemic vascular resistance increased. These differences may be due in part to a change or redistribution of pulmonary blood flow or to a diminished cellular response to the microvascular insult of the venous air embolization.

Robinson, R. R.↗

A Review of the Proposed KIsi Offset-Secant Method for Size-Insensitive Linear-Elastic Fracture Toughness Evaluation

Recently proposed modifications to ASTM E399 would provide a new size-insensitive approach to analyzing the force-displacement test record. The proposed size-insensitive linear-elastic fracture toughness, KIsi, targets a consistent 0.5mm crack extension for all specimen sizes by using an offset secant that is a function of the specimen ligament length. The KIsi evaluation also removes the Pmax/PQ criterion and increases the allowable specimen deformation. These latter two changes allow more plasticity at the crack tip, prompting the review undertaken in this work to ensure the validity of this new interpretation of the force-displacement curve. This paper provides a brief review of the proposed KIsi methodology and summarizes a finite element study into the effects of increased crack tip plasticity on the method given the allowance for additional specimen deformation. The study has two primary points of investigation: the effect of crack tip plasticity on compliance change in the force-displacement record and the continued validity of linear-elastic fracture mechanics to describe the crack front conditions. The analytical study illustrates that linear-elastic fracture mechanics assumptions remain valid at the increased deformation limit; however, the influence of plasticity on the compliance change in the test record is problematic. A proposed revision to the validity criteria for the KIsi test method is briefly discussed.

James, Mark↗

A Review of the Proposed KIsi Offset-Secant Method for Size-Insensitive Linear-Elastic Fracture Toughness Evaluation

Recently proposed modifications to ASTM E399 would provide a new size-insensitive approach to analyzing the force-displacement test record. The proposed size-insensitive linear-elastic fracture toughness, KIsi, targets a consistent 0.5mm crack extension for all specimen sizes by using an offset secant that is a function of the specimen ligament length. The KIsi evaluation also removes the Pmax/PQ criterion and increases the allowable specimen deformation. These latter two changes allow more plasticity at the crack tip, prompting the review undertaken in this work to ensure the validity of this new interpretation of the force-displacement curve. This paper provides a brief review of the proposed KIsi methodology and summarizes a finite element study into the effects of increased crack tip plasticity on the method given the allowance for additional specimen deformation. The study has two primary points of investigation: the effect of crack tip plasticity on compliance change in the force-displacement record and the continued validity of linear-elastic fracture mechanics to describe the crack front conditions. The analytical study illustrates that linear-elastic fracture mechanics assumptions remain valid at the increased deformation limit; however, the influence of plasticity on the compliance change in the test record is problematic. A proposed revision to the validity criteria for the KIsi test method is briefly discussed.

James, Mark↗

Regulatory Compliance in Multi-Tier Supplier Networks

Over the years, avionics systems have increased in complexity to the point where 1st tier suppliers to an aircraft OEM find it financially beneficial to outsource designs of subsystems to 2nd tier and at times to 3rd tier suppliers. Combined with challenging schedule and budgetary pressures, the environment in which safety-critical systems are being developed introduces new hurdles for regulatory agencies and industry. This new environment of both complex systems and tiered development has raised concerns in the ability of the designers to ensure safety considerations are fully addressed throughout the tier levels. This has also raised questions about the sufficiency of current regulatory guidance to ensure: proper flow down of safety awareness, avionics application understanding at the lower tiers, OEM and 1st tier oversight practices, and capabilities of lower tier suppliers. Therefore, NASA established a research project to address Regulatory Compliance in a Multi-tier Supplier Network. This research was divided into three major study efforts: 1. Describe Modern Multi-tier Avionics Development 2. Identify Current Issues in Achieving Safety and Regulatory Compliance 3. Short-term/Long-term Recommendations Toward Higher Assurance Confidence This report presents our findings of the risks, weaknesses, and our recommendations. It also includes a collection of industry-identified risks, an assessment of guideline weaknesses related to multi-tier development of complex avionics systems, and a postulation of potential modifications to guidelines to close the identified risks and weaknesses.

Goossen, Emray R.↗

Terrestrial quarantine considerations for unmanned sample return missions

For the purpose of understanding some of the possible implications of a terrestrial quarantine constraint on a mission and for developing a basic approach which can be used to demonstrate compliance beyond that developed for Apollo, a terrestrial quarantine study was performed. It is shown that some of the basic tools developed and used by the planetary quarantine community have applicability to terrestrial quarantine analysis. By using these tools, it is concluded that: (1) the method of biasing the earth aiming point when returning from the planet is necessary but, by itself, may not satisfy terrestrial quarantine constraints; and (2) spacecraft and container design significantly influence contamination transfer.

Hoffman, A. R.↗

Non-Invasive Measurement of Pulsatile Intracranial Pressures Using Ultrasound

Early detection of elevated intracranial pressure (ICP) will aid clinical decision-making for head trauma, brain tumor and other cerebrovascular diseases. Conventional methods, however, require surgical procedures which take time and are accompanied by increased risk of infection. Accordingly we have developed and refined a new ultrasound device to measure skull movements which are known to occur in conjunction with altered ICP. The principle of this device is based upon pulse phase locked loop (PPLL), which enables us to detect changes in distance on the order of microns between an ultrasound transducer on one side of the skull and the opposite inner surface of the cranium. The present study was designed to verify this measurement technique in cadavera. Transcranial distance was increased in steps of 10 mmHg from zero to 50 mmHg by saline infusion into the lateral ventricle of two cadavera. In separate experiments, pulsations of ICP with the amplitudes of zero to 2 mmHg were generated by rhythmic injections of saline using a syringe. When the ICP was stepwise increased from zero to 50 mmHg, transcranial distance increased in proportion with the ICP increase (y=12 x - 76, r=0.938), where y is changes in transcranial distance in microns and x is ICP in mmHg. In the data recorded while ICP pulsations were generated, fast Fourier transform analysis demonstrated that cranial pulsations were clearly associated with ICP pulsations. The results indicate that changes in transcranial distance is linearly correlated with those in ICP, and also that the PPLL device has sufficient sensitivity to detect transcranial pulsations which occur in association with the cardiac cycle. By analyzing the magnitude of cranial pulsations, we may be able to estimate the pressure-volume index in the cranium. As a result, estimates of intracranial compliance may be possible by using the PPLL device. Further studies are necessary in normal subjects and patients.

Ueno, Toshiaki↗

Use of a Prototype Airborne Separation Assurance System for Resolving Near-Term Conflicts During Autonomous Aircraft Operations

NASA is currently investigating a new concept of operations for the National Airspace System, designed to improve capacity while maintaining or improving current levels of safety. This concept, known as Distributed Air/Ground Traffic Management (DAGTM), allows appropriately equipped autonomous aircraft to maneuver freely for flight optimization while resolving conflicts with other traffic and staying out of special use airspace and hazardous weather. In order to perform these tasks, pilots use prototype conflict detection, prevention, and resolution tools, collectively known as an Airborne Separation Assurance System (ASAS). While ASAS would normally allow pilots to resolve conflicts before they become hazardous, evaluation of system performance in sudden, near-term conflicts is needed in order to determine concept feasibility. An experiment was conducted in NASA Langley's Air Traffic Operations Lab to evaluate the prototype ASAS for enabling pilots to resolve near-term conflicts and examine possible operational effects associated with the use of lower separation minimums. Sixteen commercial airline pilots flew a total of 32 traffic scenarios that required them to use prototype ASAS tools to resolve close range pop-up conflicts. Required separation standards were set at either 3 or 5 NM lateral spacing, with 1000 ft vertical separation being used for both cases. Reducing the lateral separation from 5 to 3 NM did not appear to increase operational risk, as indicated by the proximity to the intruder aircraft. Pilots performed better when they followed tactical guidance cues provided by ASAS than when they didn't follow the guidance. In an effort to improve compliance rate, ASAS design changes are currently under consideration. Further studies will of evaluate these design changes and consider integration issues between ASAS and existing Airborne Collision Avoidance Systems (ACAS).

Barhydt, Richard↗

LTF/Fluid and Cryogenic Systems Branch

Functions of the Branch: Cross-Cutting Fluids Engineering; Research and Technology Development of Cryogenic Fluid Management (CFM) Systems; Component and System level; Design, Development Test and Evaluation (DDT&E) for Fluid, CFM, Propellant and Gaseous Systems; Fluid Component Specification and Selection; Code Compliance of Pressurized Systems; Fluid/Cryogenic System Performance Analysis and Trade Studies; Hazards Analysis and Risk Assessment of Fluidic Systems; Fluids Modeling and Simulation Capabilities

Fluid↗

Cardiovascular Deconditioning in Humans: Human Studies Core

Major cardiovascular problems, secondary to cardiovascular deconditioning, may occur on extended space missions. While it is generally assumed that the microgravity state is the primary cause of cardiovascular deconditioning, sleep deprivation and disruption of diurnal rhythms may also play an important role. Factors that could be modified by either or both of these perturbations include: autonomic function and short-term cardiovascular reflexes, vasoreactivity, circadian rhythm of cardiovascular hormones (specifically the renin-angiotensin system) and renal sodium handling and hormonal influences on that process, venous compliance, cardiac mass, and cardiac conduction processes. The purpose of the Human Studies Core is to provide the infrastructure to conduct human experiments which will allow for the assessment of the likely role of such factors in the space travel associated cardiovascular deconditioning process and to develop appropriate countermeasures. The Core takes advantage of a newly-created Intensive Physiologic Monitoring (IPM) Unit at the Brigham and Women's Hospital, Boston, MA, to perform these studies. The Core includes two general experimental protocols. The first protocol involves a head down tilt bed-rest study to simulate microgravity. The second protocol includes the addition of a disruption of circadian rhythms to the simulated microgravity environment. Before and after each of these environmental manipulations, the subjects will undergo acute stressors simulating changes in volume and/or stress, which could occur in space and on return to Earth. The subjects are maintained in a rigidly controlled environment with fixed light/dark cycles, activity pattern, and dietary intake of nutrients, fluids, ions and calories.

Williams, Gordon↗

Governing Data Findability, Accessibility, Interoperability and Reusability (FAIR) Compliance

The most recent data strategy documents at both the federal and NASA levels stipulate that systems should strive for the data they manage to be Findable, Accessible, Interoperable, and Reusable (FAIR). The NASA Life Sciences Portal (NLSP) has already begun leading efforts in this area for HRP, initiating efforts to comply with the FAIR principles. The broad interpretation of the FAIR principles has led to a plethora of tools that use a splay of metrics specifically but variably developed to judge how compliant data and systems are with the principles. A recent review [3] identified and studied 1,180 metrics across 20 publicly available tools for checking FAIR compliance of data and systems. Because of their very recent development, many organizations and data systems managers and developers have not yet had adequate time or resources to understand these FAIR compliance tools and metrics, their variations in design, accuracy or ease of application to their specific data sets and systems. Thus, it would be best for larger organizations like NASA to approach formulating a strategy for governance of FAIR compliance that can be flexibly applied and is adaptable to an evolving awareness knowledge of FAIR compliance methods and tools. In September 2024, the NASA Science Mission Directorate(SMD) organized a workshop on NASA science data repositories, including the topics of implementing FAIR and governing FAIR compliance across SMD. The initial part of these FAIR discussions focused on developing consensus around required science metadata fields. This is challenging given the diverse nature of NASA’s scientific data portfolio, the variety of metadata models and vocabularies used, and variable level of resources available to curate these data. Later discussion focused on three possible approaches to governing FAIR compliance: distributed, in which various programs, projects or systems define their own methods for assessing FAIR compliance, reporting results up appropriate management lines; centralized, in which higher-level organization(s) specify compliance tools or methods for the various data systems; and multi-level, in which a group comprised of individuals with expertise from multiple levels with organizations is formed to provide guidance and/or specifications for governing FAIR compliance. We report on the recommendations this session yielded, and how these might be shaped specifically to help implement and govern the compliance with FAIR of Human Research Program data and systems.

governance↗

Analyzing The Effect of Skin Postbuckling on General Stresses, Strains and Stability of Composite Structures

The present paper is a final technical report within the NCCW-1-233 research program (dated June 1, 1997) accomplished as a part of co-operation between United States' NASA and Russia's Goskomoboronprom in aeronautics, and continues similar NCCW-73 and NCC-1-233 programs accomplished in 1996 and 1997, respectively. The report concludes studies in two domains, "Analyzing the effect of skin postbuckling on general stresses and strains in a composite structure" and "Evaluating the effect of skin postbuckling behavior on general stability of a composite structure"; the work was fulfilled in compliance with NCC-1-233 requirements (as of June 1, 1997). Also, the present studies may be regarded as a partial generalization of efforts in [1, 2] conducted within the above programs in what concerns postbuckling behavior of composite structures.

Zamula, G. N.↗

Effects of 12 days exposure to simulated microgravity on central circulatory hemodynamics in the rhesus monkey

Central circulatory hemodynamic responses were measured before and during the initial 9 days of a 12-day 10 degrees head-down tilt (HDT) in 4 flight-sized juvenile rhesus monkeys who were surgically instrumented with a variety of intrathoracic catheters and blood flow sensors to assess the effects of simulated microgravity on central circulatory hemodynamics. Each subject underwent measurements of aortic and left ventricular pressures, and aortic flow before and during HDT as well as during a passive head-up postural test before and after HDT. Heart rate, stroke volume, cardiac output, and left ventricular end-diastolic pressure were measured, and dP/dt and left ventricular elastance was calculated from hemodynamic measurements. The postural test consisted of 5 min of supine baseline control followed by 5 minutes of 90 degrees upright tilt (HUT). Heart rate, stroke volume, cardiac output, and left ventricular end-diastolic pressure showed no consistent alterations during HDT. Left ventricular elastance was reduced in all animals throughout HDT, indicating that cardiac compliance was increased. HDT did not consistently alter left ventricular +dP/dt, indicating no change in cardiac contractility. Heart rate during the post-HDT HUT postural test was elevated compared to pre-HDT while post-HDT cardiac output was decreased by 52% as a result of a 54% reduction in stroke volume throughout HUT. Results from this study using an instrumented rhesus monkey suggest that exposure to microgravity may increase ventricular compliance without alternating cardiac contractility. Our project supported the notion that an invasively-instrumented animal model should be viable for use in spaceflight cardiovascular experiments to assess potential changes in myocardial function and cardiac compliance.

NASA Discipline Cardiopulmonary↗

Construction of a Piezoresistive Neural Sensor Array

The construction of a piezoresistive - piezoelectric sensor (or actuator) array is proposed using 'neural' connectivity for signal recognition and possible actuation functions. A closer integration of the sensor and decision functions is necessary in order to achieve intrinsic identification within the sensor. A neural sensor is the next logical step in development of truly 'intelligent' arrays. This proposal will integrate 1-3 polymer piezoresistors and MLC electroceramic devices for applications involving acoustic identification. The 'intelligent' piezoresistor -piezoelectric system incorporates printed resistors, composite resistors, and a feedback for the resetting of resistances. A model of a design is proposed in order to simulate electromechanical resistor interactions. The goal of optimizing a sensor geometry for improving device reliability, training, & signal identification capabilities is the goal of this work. At present, studies predict performance of a 'smart' device with a significant control of 'effective' compliance over a narrow pressure range due to a piezoresistor percolation threshold. An interesting possibility may be to use an array of control elements to shift the threshold function in order to change the level of resistance in a neural sensor array for identification, or, actuation applications. The proposed design employs elements of: (1) conductor loaded polymers for a 'fast' RC time constant response; and (2) multilayer ceramics for actuation or sensing and shifting of resistance in the polymer. Other material possibilities also exist using magnetoresistive layered systems for shifting the resistance. It is proposed to use a neural net configuration to test and to help study the possible changes required in the materials design of these devices. Numerical design models utilize electromechanical elements, in conjunction with structural elements in order to simulate piezoresistively controlled actuators and changes in resistance of sensors. The construction of these devices may show significant improvement in ability to interrogate signals and in the control of effective compliance. This work focuses on the development a variety of series/parallel interconnected piezoresistive control elements for the neural sensing function.

Carlson, W. B.↗

Contamination control of the space shuttle Orbiter crew compartment

Effective contamination control as applied to manned space flight environments is a discipline characterized and controlled by many parameters. An introduction is given to issues involving Orbiter crew compartment contamination control. An effective ground processing contamination control program is an essential building block to a successful shuttle mission. Personnel are required to don cleanroom-grade clothing ensembles before entering the crew compartment and follow cleanroom rules and regulations. Prior to crew compartment entry, materials and equipment must be checked by an orbiter integrity clerk stationed outside the white-room entrance for compliance to program requirements. Analysis and source identification of crew compartment debris studies have been going on for two years. The objective of these studies is to determine and identify particulate generating materials and activities in the crew compartment. Results show a wide spectrum of many different types of materials. When source identification is made, corrective action is implemented to minimize or curtail further contaminate generation.

Bartelson, Donald W.↗

Postural Effects on Intracranial Pressure as Assessed Noninvasively

This study was designed to investigate effects of whole body tilting on intracranial compliance and pressure in six healthy volunteers by using a noninvasive ultrasonic device. Subjects were randomly tilted up or down sequentially at 60 degree, 30 degree head-up, supine, and 15 degree head-down position for one minute at each angle. We measured arterial blood pressure with a finger pressure cuff and changes in intracranial distance with an ultrasonic device. The device measures skull movement on the order of micro-meter. Our ultrasound technique demonstrates that skull movement is highly correlated (r$(circumflex){2}$=0.77) with intracranial pressure variations due to cerebral arterial pulsation. The amplitudes of arterial pressure (r$(circumflex){2}$=0.99 and those of intracranial distance changes (r$(circumflex){2}$=0.87) associated with one cardiac cycle were inversely correlated with the angle of tilt. The ratio of pulsation amplitudes for intracranial distance over arterial pressure also showed a significant increase as the angle of tilt was lowered (p=0.003). Thus, postural changes alter intracranial compliance in healthy volunteers and intracranial volume-buffering capacity is reduced in head-down position.

Ueno, Toshiaki↗