Search NASA⌕ Search

SEARCH · Search NASA

Results for “Concentration of measure”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 55 records · Page 3

Dual-Pump CARS Thermometry and Species Concentration Measurements in a Supersonic Combustor

The dual-pump coherent anti-Stokes Raman spectroscopy (CARS) method was used to measure temperature and the absolute mole fractions of N2, O2 and H2 in a supersonic combustor. Experiments were conducted in NASA Langley Research Center's Direct Connect Supersonic Combustion Test Facility. In this facility, hydrogen and air bum to increase the enthalpy of the test gas; O2 is then added to simulate air. This gas is expanded through a Mach 2 nozzle and into a combustor model consisting of a short constant-area section followed by a small rearward facing step and another constant area section. At the end of this straight section H2 fuel is then injected at Mach 2 and at 30 deg. angle with respect to the freestream. One wall of the duct then expands at a 3 deg. angle for over 1 meter. The ensuing combustion is monitored optically through ports in the side of the combustor. CARS measurements were performed at the nozzle exit and at four different planes downstream fuel injection. Maps were obtained of the mean temperature, as well as quantitative N2 and O2 and qualitative H2 mean mole fraction fields. Correlations between fluctuations of the different measured parameters are presented for one of the planes of data.

OByrne, Sean↗

CARS Temperature and Species Concentration Measurements in a Supersonic Combustor with Normal Injection

The dual-pump coherent anti-Stokes Raman spectroscopy (CARS) method was used to measure temperature and the absolute mole fractions of N2, O2 and H2 in a supersonic combustor. Experiments were conducted in the NASA Langley Direct-Connect Supersonic Combustion Test Facility. CARS measurements were performed at the facility nozzle exit and at three planes downstream of fuel injection. Processing the CARS measurements produced maps of the mean temperature, as well as quantitative N2 and O2 and qualitative H2 mean mole fraction fields at each plane. The CARS measurements were also used to compute correlations between fluctuations of the different simultaneously measured parameters. Comparisons were made between this 90 degree angle fuel injection case and a 30 degree fuel injection case previously presented at the 2004 Reno AIAA Meeting.

Tedder, S. A.↗

Dual-Pump CARS Temperature and Species Concentration Measurements in a Supersonic Combustor

The dual-pump coherent anti-Stokes Raman scattering (CARS) method was used to measure temperature and the mole fractions of N2 and O2 in a supersonic combustor. Experiments were conducted in NASA Langley Research Center s Direct Connect Supersonic Combustion Test Facility. In this facility, H2 and oxygen-enriched air burn to increase the enthalpy of the simulated air test gas. This gas is expanded through a Mach 2 nozzle and into a combustor model consisting of a short constant-area section followed by a small rearward-facing step and another constant-area section. At the end of this straight section, H2 fuel is injected at Mach 2 and at a 30 angle with respect to the freestream. One wall of the duct then expands at a 3 angle for over 1 meter. The ensuing combustion is probed optically through ports in the side of the combustor. Dual-pump CARS measurements were performed at the facility nozzle exit and at four planes downstream of fuel injection. Maps are presented of the mean temperature, as well as N2 and O2 mean mole fraction fields. Correlations between fluctuations of the different measured parameters are also presented.

O'Byrne, S.↗

Direct measurement of surface carbon concentrations

Measurements of surface concentrations of carbon in lunar soils and soil breccias provide information on the origin of carbon in the regolith. The reaction C-12 (d, p sub zero) is used to measure 'surface' and 'volume' concentrations in lunar samples. This method has a depth resolution of 1 micron, which permits only a 'surface' and a 'volume' component to be measured. Three of four Apollo 16 double drive tube samples show a surface carbon concentration of about 8 by 10 to the 14th power/sq cm, whereas the fourth sample gave 4 by 10 to the 14th power/sq cm. It can be convincingly shown that the measured concentration does not originate from fluorocarbon or hydrocarbon contaminants. Surface adsorbed layers of CO or CO2 are removed by a sputter cleaning procedure using a 2-MeV F beam. It is shown that the residual C concentration of 8 by 10 to the 14th power/sq cm cannot be further reduced by increased F fluence, and it is therefore concluded that it is truly lunar. If one assumes that the measured surface C concentration is a steady-state concentration determined only by a balance between solar-wind implantation and sputtering, a sputter erosion rate of 0.1 A/yr is obtained. However, it would be more profitable to use an independently derived sputter erosion rate to test the hypothesis of a solar-wind origin of the surface carbon.

Filleux, C.↗

Accuracy of rocket measurements of lower ionosphere electron concentrations

Measurements of electron concentration taken at the same time and at the same place in the lower ionosphere by independent instrumentation mounted on the same rocket are described. The technique utilizes Faraday rotation and differential absorption of radio waves propagating from the ground to the rocket at two different frequencies. Agreement near 90 km within 7%, 6%, 8%, and 3% is demonstrated by the four available cases of coincidence in time and altitude. Maximum dispersion at other altitudes is calculated from known random errors. Stronger variation of electron collision frequency with altitude than with season is indicated by 34 measurements between 75 and 100 km. Insensitivity of electron concentration determinations at 72 km to errors in extrapolated collision frequency models is demonstrated.

Mechtly, E. A.↗

Measuring Hydrogen Concentrations in Metals

Commercial corrosion-measurement system adapted to electrochemical determination of hydrogen concentrations in metals. New technique based on diffusion of hydrogen through foil specimen of metal. In sample holder, hydrogen produced on one side of foil, either by corrosion reaction or by cathodic current. Hydrogen diffused through foil removed on other side by constant anode potential, which leads to oxidation of hydrogen to water. Anode current is measure of concentration of hydrogen diffusing through foil. System used to study hydrogen uptake, hydrogen elimination by baking, effect of heat treatment, and effect of electroplating on high-strength steels.

Danford, M. D.↗

Sensitivity of the predicted CO-OH-CH4 perturbation to tropospheric NOx concentrations

Measurements indicate that ambient NOx(NO + NO2) concentrations vary over at least an order of magnitude in the troposphere. Thus it is of interest to study atmospheric chemistry with NOx concentrations covering this range. In this paper we present steady state calculations which show that as NOx concentrations are increased from very low values, the hydroxyl radical concentration increases at first and then decreases. This change of behavior occurs at a concentration of NO2 of about 0.23 ppb in the model. Also, the response of the atmosphere to increased CO fluxes undergoes a qualitative change as a function of the concentration of NOx. At low levels of NOx concentration, an increase in CO fluxes into the atmosphere depletes the OH concentration and increases the concentrations of CH4 and H2, as reported in the literature. However, at high values of NOx concentration, increased CO fluxes give rise to an increase in the OH concentration and, consequently, a decrease in the concentrations of CH4 and H2.

Hameed, S.↗

Airborne, Direct-Detection, 2-μm Triple-Pulse IPDA Lidar for Simultaneous and Independent Atmospheric Water Vapor and Carbon Dioxide Active Remote Sensing

Atmospheric water vapor and carbon dioxide are important greenhouse gases that significantly contribute to the global radiation budget on Earth. A 2-micron triple-pulse, Integrated Path Differential Absorption (IPDA) lidar instrument for ground and airborne atmospheric carbon dioxide and water vapor concentration measurements using direct detection was developed at NASA Langley Research Center. This active remote sensing instrument provides an alternate approach with significant advantages for measuring atmospheric concentrations of the gases. A high energy pulsed laser transmitter approach coupled with sensitive receiver detection provides a high-precision measurement capability by having a high signal-to-noise ratio. This paper presents the concept, development, integration and testing of the 2-micron triple-pulse IPDA. The integration includes the various IPDA transmitter, receiver and data acquisition subsystems and components. Ground and airborne testing indicated successful operation of the IPDA lidar.

Refaat, Tamer F.↗

Ground Test Stand Development for One-step Electrochemical Production of High-Pressure Oxygen

NASA designed a test rig, High-Pressure Oxygen Generation Assembly (HPOGA) to test a novel method of electrolysis as an alternative technology to the state-of-the-art Oxygen Generation Assembly (OGA) currently on the International Space Station (ISS). This approach involves utilizing a specialized electrolysis cell stack designed to both generate and compress high-pressure oxygen up to 3600 PSIG. The design eliminates the need for an external compressor and hydrogen separator, streamlining the oxygen generation process. HPOGA tests the viability of an electrolysis cell stack for extended life usage. Within the system, there are several key subsystems: nitrogen, high/low pressure oxygen, hydrogen, water recirculation, and water injection. The water injection subsystem supplies deionized (DI) water to a centralized reservoir for consumption. Subsequently, a water recirculation loop transfers the DI water across the cathode side of the electrolysis cell stack with constant flow rate. The result is a supply of hydrogen in the water loop and oxygen accumulation on the anode side of the cell stack. Hydrogen is evaporated out as part of the hydrogen sub-system which also measures hydrogen/oxygen concentration for safety. The oxygen subsystem is responsible for managing high pressure oxygen, O2 exhaust, and conducting hydrogen/oxygen concentration measurements. The nitrogen subsystem serves dual functions, purging the hydrogen/oxygen subsystems, and regulating pressure in both high/low-pressure O2 sections via pneumatic back pressure regulators. Various sensors monitor pressure, temperature, humidity, gas concentration and flow rate in each subsystem. This paper presents the design and testing of a comprehensive test stand, which serves to operate and functionally verify the performance of the electrolysis cell while offering valuable lessons learned.

electrolysis↗

NO and O3 measurements in the lower stratosphere from a U-2 aircraft

In situ measurements of nitric oxide and ozone were carried out at altitudes up to 21 km during two flights of a U-2 aircraft on Dec. 6 and 18, 1973, over the west coast of the United States. A chemiluminescent detector based on the luminescent reaction of nitric acid with excess ozone was used in nitric acid measurements. Ozone concentration measurements were based on the absorption of the Hg line at 2,537 A in the Hartley continuum. The results are compared with available data.

Loewenstein, M.↗

A measurement of the vibrational band strength for the upsilon sub 3 band of the HO2 radical

The HO2 radicals generated in a discharge-flow system were observed with tunable diode laser absorption in the P-branch of the nu(3) vibrationall band at 1080/cm. The observed line positions agree with those calculated from the molecular constants for the nu(3) bland obtained from a previous study using laser magnetic resonance spectroscopy. The band strength was determined by observing line center absoptions when HO2 is produced in the reaction F + H2O2 yields HO2 + HF (k1) with a measured concentration of atomic fluorine and excess hydrogen peroxide. F-atom concentrations are measured by diode laser absorption of the spin-orbit transition at 404/cm. The analysis accounts for HO2 losses due to the reactions of HO2 + HO2 yields H2O2 + O2 (k3) and F + HO2 yields HF + O2 (k4). The line strength for the 6(15) 7(16) F(1) transition is 2.9 x 10 to the 21st power sq cm/molecule/cm which corresponds to a nu(3) band strength of 34 +/- 9 sq/cm(STP atm). This value is a factor of 6 lower than previous ab initio calculations. These results will be useful in assessing the feasibility of atmospheric measurements of HO2 using infrared absorption techniques.

Zahniser, M. S.↗

Concentration distributions in cylindrical combustors

Experimental studies have been conducted with the aim to obtain a better understanding of the fluid dynamics of mixing in gas turbine combustors, and solid fuel ramjet combustors subject to spin. The present investigation represents a continuation of studies conducted by So et al. (1984). It is also concerned with the verification of some conclusions reported by Ahmed et al. (1984). Attention is given to the experimental facility and instrumentation, centerline concentration measurements, mean concentration profiles, and a comparison of concentration and axial velocity results in the case of swirling flow.

Ahmed, S. A.↗

Predicting the oxidative lifetime of beta NiAl-Zr alloys

Nickel aluminides containing 40 to 50 at. pct Al and 0.1 at. pct Zr were studied following cyclic oxidation at 1400 C. The selective oxidation of Al resulted in the formation of protective Al2O3 scales on each alloy composition. However, repeated cycling eventually resulted in the gradual formation of less-protective NiAl2O4, first appearing on the 40Al alloys followed at longer times on the 45Al alloys. The appearance of the NiAl2O4, signaling the end of the protective scale-forming capability of the alloy, was related to the presence of gamma-prime (Ni3Al) which formed as a result of the loss of Al from the sample. A diffusion model, based on finite-difference techniques, was developed to predict the protective life of beta Ni-Al alloys. This model predicts Ni and Al concentration profiles after various oxidation exposures. The model can predict the oxidative lifetime due to Al depletion when the Al concentration decreases to a critical concentration. Measured Al concentration profiles on two alloys after various oxidation exposures are compared to those predicted by the diffusion model. The time to the appearance of the NiAl2O4 and that predicted by the diffusion model are compared and discussed.

Nesbitt, J. A.↗

Using Laser-Induced Incandescence To Measure Soot in Exhaust

An instrumentation system exploits laser-induced incandescence (LII) to measure the concentration of soot particles in an exhaust stream from an engine, furnace, or industrial process that burns hydrocarbon fuel. In comparison with LII soot-concentration-measuring systems, this system is more complex and more capable.

Bachalo, William D.↗