Search NASA⌕ Search

SEARCH · Search NASA

Results for “Concrete Curing”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 55 records · Page 3

Multiphysics and Multiscale Modeling of Coupled Transport of Chloride Ions in Concrete

Chloride ions (Cl−)-induced corrosion is one of the main degradation mechanisms in reinforced concrete (RC) structures. In most situations, the degradation initiates with the transport of Cl− from the surface of the concrete towards the reinforcing steel. The accumulation of Cl− at the steel-concrete interface could initiate reinforcement corrosion once a threshold Cl− concentration is achieved. An accurate numerical model of the Cl− transport in concrete is required to predict the corrosion initiation in RC structures. However, existing numerical models lack a representation of the heterogenous concrete microstructure resulting from the varying environmental conditions and the indirect effect of time dependent temperature and relative humidity (RH) on the water adsorption and Cl− binding isotherms. In this study, a numerical model is developed to study the coupled transport of Cl− with heat, RH and oxygen (O2) into the concrete. The modeling of the concrete microstructure is performed using the Virtual Cement and Concrete Testing Laboratory (VCCTL) code developed by the U.S. National Institute of Standards and Technology (NIST). The concept of equivalent maturation time is utilized to eliminate the limitation of simulating concrete microstructure using VCCTL in specific environmental conditions such as adiabatic. Thus, a time-dependent concrete microstructure, which depends on the hydration reactions coupled with the temperature and RH of the environment, is achieved to study the Cl− transport. Additionally, Cl− binding isotherms, which are a function of the pH of the concrete pore solution, Cl− concentration, and weight fraction of mono-sulfate aluminate (AFm) and calcium-silicate-hydrate (C-S-H), obtained from an experimental study by the same authors are utilized to account for the Cl− binding of cement hydration products. The temperature dependent RH diffusion was considered to account for the transport of Cl− with moisture transport. The temperature and RH diffusion in the concrete domain, composite theory, and Cl− binding and water adsorption isotherms are used in combination, to estimate the ensuing Cl− diffusion field within the concrete. The coupled transport process of heat, RH, Cl−, and O2 is implemented in the Multiphysics Object-Oriented Simulation Environment (MOOSE) developed by the U.S. Idaho National Laboratory (INL). The model was verified and validated using data from multiple experimental studies with different concrete mixture proportions, curing durations, and environmental conditions. Additionally, a sensitivity analysis was performed to identify that the water-to-cement (w/c) ratio, the exposure duration, the boundary conditions: temperature, RH, surface Cl− concentration, Cl− diffusion coefficient in the capillary water, and the critical RH are the important parameters that govern the Cl− transport in RC structures. In a case study, the capabilities of the developed numerical model are demonstrated by studying the complex 2D diffusion of Cl− in a RC beam located in two different climatic regions: warm and humid weather in Galveston, Texas, and cold and dry weather in North Minnesota, Minnesota, subjected to time varying temperature, RH, and surface Cl− concentrations.

composite theory↗

Microbial Curing of Cement for Energy Applications

Rutgers University, Lawrence Livermore National Laboratory, and the University of Arizona executed this program over 36 months with a 4-Task Program: (M1)-Microbial Engineering (M2)-Microstructure Modelling, (M3) Cement and Concrete Formulation, (M4)-Techno-economic analysis (TEA) and lifecycle assessment (LCA). This program developed a new carbonate cement concrete manufacturing process called microbial curing (MBC). MBC utilizes in-situ microbial production of CO 2 that dissolves into pore-bound water to carbonate a cementitious material creating a bonding matrix of CaCO 3 and SiO 2 that hardens and densifies the material. This is the first work of this type where calcium silicate was used in microbial studies. All other work reported in the literature always used a soluble form of calcium. This final report describes the work done in the final quarter, the best procedures and results, and the final techno-economic and lifecycle analyses. This quarter, we cast and cured twenty-five (4”x8”) cylinder samples. The compressive strength, split tensile, Young’s modulus, chloride permeability, and creep measurements were performed. These measurements demonstrated that MBC of calcium silicate concrete exhibits scaling problems due to the escape of ammonia gas, a product of the microbial reaction to generate CO 2 . As curing proceeds, the ability for the gas to escape from within the cylinder is restricted by the outer cylindrical portions densifying, making the outer portion highly impermeable to gas flow. In contrast, the small samples cured are uniformly cured, forming materials whose mechanical properties are 7x better than the large samples. This problem needs to be solved before this technology can be commercialized. The techno-economic and lifecycle analyses indicate that the technology developed in this program exhibits a significant opportunity to reduce the cost of cement and CO 2 emissions associated with concrete, provided the curing issue associated with larger samples can be addressed.

36 MATERIALS SCIENCE↗

Combined curing as a novel approach to improve resistance of ultra-high performance concrete to explosive spalling under high temperature and its mechanical properties

Highlights: • The combined curing can significantly enhance the resistance of UHPC to explosive spalling under high temperature. • The combined curing can improve the mechanical properties of UHPC remarkably. • Both further hydration of residual cement and pozzolanic reaction are activated under a high temperature steam condition. - Abstract: The influence of a combined curing composed of precuring in hot water and heating in dry air on mechanical properties and explosive spalling of ultra-high performance concrete (UHPC) subjected to high temperature was investigated in this experiment. Meanwhile, the microstructure of UHPC was determined by means of X-ray diffraction (XRD) with Rietveld method, thermogravimetric analysis (TGA), scanning electron microscope (SEM) and mercury intrusion porosimetry (MIP). The results indicate that the combined curing improves the mechanical properties of UHPC remarkably. More importantly, it is quite efficient to enhance the resistance of UHPC to explosive spalling under high temperature, which should be a novel approach to prohibit spalling occurrence, different from adding polypropylene fiber. During dry air heating in the combined curing, a high temperature steam environment is established in the dense structure framework of UHPC formed in the preceding hot water curing. Both further hydration of residual cement and pozzolanic reaction of mineral admixtures can be activated during the dry air heating, leading to not only the formation of a large amount of dense hydrates (such as C-S-H gels, katoite, tobermorite and xonotlite, etc.), which accumulate in the aforementioned existing framework, but also the consumption of most of internal free water. Therefore, both mechanical properties of UHPC and its resistance to explosive spalling under high temperature can be enhanced significantly.

36 MATERIALS SCIENCE↗

Effect of nano-SiO{sub 2} particles and curing time on development of fiber-matrix bond properties and microstructure of ultra-high strength concrete

Bond properties between fibers and cementitious matrix have significant effect on the mechanical behavior of composite materials. In this study, the development of steel fiber-matrix interfacial bond properties in ultra-high strength concrete (UHSC) proportioned with nano-SiO{sub 2} varying between 0 and 2%, by mass of cementitious materials, was investigated. A statistical model relating either bond strength or pullout energy to curing time and nano-SiO{sub 2} content was proposed by using the response surface methodology. Mercury intrusion porosimetry (MIP) and backscatter scanning electron microscopy (BSEM) were used to characterize the microstructure of the matrix and the fiber-matrix interface, respectively. Micro-hardness around the embedded fiber and hydration products of the matrix were evaluated as well. Test results indicated that the optimal nano-SiO{sub 2} dosage was 1% in terms of the bond properties and the microstructure. The proposed quadratic model efficiently predicted the bond strength and pullout energy with consideration of curing time and nano-SiO{sub 2} content. The improvement in bond properties associated with nano-silica was correlated with denser matrix and/or interface and stronger bond and greater strength of hydration products based on microstructural analysis.

36 MATERIALS SCIENCE↗

Predicting Saturated Hydraulic Conductivity over Time for Degrading Saltstone Vault Concrete - 20376

At the Savannah River Site (SRS), low-level liquid tank waste is mixed with cementitious materials to produce a solid, monolithic waste form referred to as saltstone. The liquid saltstone mixture is pumped into massive concrete structures referred to as saltstone disposal units (SDUs) for curing and long-term storage. SDUs are vaults made of high performance concrete forming a barrier between saltstone and the surrounding environment. Predicting the long-term performance of SDU vault concrete, as well as the saltstone material itself, is critical to understanding the potential releases of radionuclides to the surrounding environment as described in the Saltstone Disposal Facility (SDF) performance assessment (PA). The hydraulic conductivity profile for SDU vault concrete was conservatively assumed to degrade linearly from the initial saturated hydraulic conductivity of the intact concrete over a long period of time. The initial hydraulic properties of saturated SDU vault concrete have been measured, and the final hydraulic properties of degraded vault concrete are assumed to be the same as the porous backfill material that will surround the vault after closure. The assumed final condition of the vault concrete is also conservative in that it provides a greater estimate of water penetration through the vault than would generally be expected. Therefore, insights that provide more realistic but conservative estimates as to how degradation processes may change the hydraulic properties of the SDU vault concrete, the time dependent relationship of the vault concrete hydraulic properties to degradation (and thus time), and the final hydraulic properties of the vault concrete provides useful additions to the SDF PA. This paper focuses on the assumption that the saltstone vault concrete saturated hydraulic conductivity would decrease linearly as a function of degradation time; this assumption resulted from a worst-case, weighted (by relative layer thickness), arithmetic average of intact and backfill material hydraulic conductivities representing flow parallel to a layered system. This research indicates that the effective saturated hydraulic conductivity of the degraded SDU vault concrete should be based on the relative thickness-weighted geometric mean of the intact and degraded layers hydraulic conductivities. This alternative, which is supported extensively in the relevant literature and evaluated in this paper, leads to a more realistic and defensible estimate of the effective saturated hydraulic conductivity in degraded vault concrete while remaining conservative. The impact of using the more realistic estimate of the effective saturated hydraulic conductivity for the degraded concrete decreases the effective saturated hydraulic conductivity by up to several orders of magnitude for early times (i.e., when the SDU vault concrete is assumed degraded via sulfate attack and carbonation). This revised estimate of the effective saturated hydraulic conductivity has been implemented in the recently revised SDF PA. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Sustainable construction: Composite use of tyres and ash in concrete

An investigation was carried out to establish the physical, mechanical and chemical characteristics of a non-standard (unprocessed) pulverised fuel ash (PFA) and waste tyres from a former landfill site at the Power Station Hill near Church Village, South Wales, United Kingdom. Investigations are on-going to establish the suitability of the fly ash and/or tyres in road construction (embankment and pavement) and also in concrete to be used in the construction of the proposed highway. This paper reports on concrete-based construction where concrete blends (using various levels of PFA as partial replacement for Portland cement (PC), and shredded waste tyres (chips 15-20 mm) as aggregate replacement) were subjected to unconfined compressive strength tests to establish performance, hence, optimising mix designs. Strength development up to 180 days for the concrete made with PC-PFA blends as binders (PC-PFA concrete), with and without aggregate replacement with tyre chips, is reported. The binary PC-PFA concrete does not have good early strength but tends to improve at longer curing periods. The low early strength observed means that PC-PFA concrete cannot be used for structures, hence, only as low to medium strength applications such as blinding, low-strength foundations, crash barriers, noise reduction barriers, cycle paths, footpaths and material for pipe bedding.

01 COAL, LIGNITE, AND PEAT↗

Application of Nonlinear Elastic Resonance Spectroscopy For Damage Detection In Concrete: An Interesting Story

Nonlinear resonance ultrasound spectroscopy experiments conducted on concrete cores, one chemically and mechanically damaged by alkali-silica reactivity, and one undamaged, show that this material displays highly nonlinear wave behavior, similar to many other damaged materials. They find that the damaged sample responds more nonlinearly, manifested by a larger resonant peak and modulus shift as a function of strain amplitude. The nonlinear response indicates that there is a hysteretic influence in the stress-strain equation of state. Further, as in some other materials, slow dynamics are present. The nonlinear response they observe in concrete is an extremely sensitive indicator of damage. Ultimately, nonlinear wave methods applied to concrete may be used to guide mixing, curing, or other production techniques, in order to develop materials with particular desired qualities such as enhanced strength or chemical resistance, and to be used for damage inspection.

54 ENVIRONMENTAL SCIENCES↗

OECD MCCI Project: Category 4 Integral Test to Validate Severe Accident Codes: Core-Concrete Interaction Test Six (CCI-6) Test Plan (Rev. 6)

Ex-vessel debris coolability is an important light water reactor (LWR) safety issue. For existing plants, resolution of this issue will confirm the technical basis for severe accident management guidelines (SAMGs). For new reactors, understanding this issue will help confirm the effectiveness of the design and implementation of new accident mitigation features and severe accident management design alternatives (SAMDAs). The first OECD-MCCI program conducted reactor material experiments focused on achieving the following technical objectives: i) provide confirmatory evidence and data for various cooling mechanisms through separate effect tests for severe accident model development, and ii) provide long-term 2-D core-concrete interaction data for code assessment and improvement. The PRG recommends that the OA design a 70 cm x 70 cm test, with two concrete side walls, using CEA siliceous concrete, 6 wt% concrete composition, early top flooding initiated when ablation is established and melt temperature has stabilized. The melt depth shall be 30 cm. The test will be designed for two specific phases. The first phase will provide for 30 cm for radial ablation and 25 cm for vertical ablation. In the event that the melt is not cooled down by top flooding during the first phase, a second and separate test phase will begin involving bottom flooding. This second phase will be initiated when axial ablation depth reaches 25 cm. The design should be mindful of the curing time of the concrete. The instrumentation should be refined to provide data on the water injection characteristics and melt temperature near the lateral walls. In response to this recommendation, the objective of this document is to provide a summary test plan for this sixth Core-Concrete Interaction (CCI-6) experiment for PRG review. Test specifications that were developed as part of the design work are provided.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Internal curing with lightweight aggregate produced from biomass-derived waste

Shrinkage of concrete may lead to cracking and ultimately to a reduction of the service life of concrete structures. Among known methods for shrinkage mitigation, internal curing with porous aggregates was successfully utilized in the last couple of decades for decreasing autogenous and drying shrinkage. In this paper, the internal curing performance of pre-saturated lightweight aggregates produced from biomass-derived waste (bio-LWA) was studied. In the first part of this paper, the microstructure of the bio-LWA is investigated, with special focus on their pore structure and on their water absorption and desorption behavior. The bio-LWA has large porosity and coarse pore structure, which allows them to release the entrained water at early age and counteract self-desiccation and autogenous shrinkage. In the second part, the efficiency of internal curing in mortars incorporating the bio-LWA is examined by neutron tomography, internal relative humidity and autogenous deformation measurements.

36 MATERIALS SCIENCE↗

Enhancement of Structural Health Monitoring Framework by Optimizing Vibro-Acoustic Modulation Technique to Localize Alkali-Silica Reaction Degradation in Medium-Sized Concrete Samples

Assessment and management of aging concrete structures in nuclear power plants require a more systematic approach than simple reliance on existing code margins of safety. Health monitoring of concrete structures is performed to understand the current condition of a structure based on heterogeneous measurements and then produce high confidence actionable information regarding structural integrity. This information can then be used to support operational and maintenance decisions. The objectives of this ongoing research project focus on health monitoring and data analytics of concrete slabs containing reactive aggregates and thus subjected to degradation due to alkali-silica reaction (ASR). A controlled concrete slab with four pockets of reactive aggregates (pure silica, wells, placitas, and spratt) was cast at Vanderbilt University and cured in representative conditions to accelerate degradation due to ASR. A set of four concrete samples were also cast and cured at the University of Alabama for ASR testing. Of these four samples, two slabs contained reactive aggregates while the other two had the non-reactive aggregate counterparts mixed throughout the samples. Vibro-acoustic methods were used on these slabs to locate large pockets of ASR within the reactive samples and determine the effects of rebar using the non-reactive slabs. Vibro-acoustic modulation (VAM) is a vibration-based NDE method that utilizes signatures of nonlinear dynamic interactions on contact surfaces of crack or delamination damage to detect and localize the damage. VAM analysis was conducted on both Vanderbilt and Alabama’s samples using multiple variables for damage detection and localization. The results from the data analysis of the NDE vibro-acoustic techniques on concrete slabs cured at Vanderbilt University and the University of Alabama are discussed in detail in this report. The major outcome of the analysis suggests that the VAM method can be used to detect damage within the concrete samples by comparing the results found in different sections of the samples. Results for damage localization are dependent on multiple variables used in the vibro-acoustic modulation experiments. Digital image correlation (DIC) is a three-dimensional, full-field, optical NDE technique to measure contour, deformation, vibration, and strain. The application of the digital image correlation technique to study ASR-related degradation on a large concrete sample at the University of Tennessee Knoxville is discussed and observations are presented in this report.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Uncertainty Quantification in Vibro-Acoustics Diagnosis of Alkali-Silica Reaction Degradation in Medium-Sized Concrete Samples

The objectives of this ongoing research project focus on health monitoring and data analytics of concrete slabs containing reactive aggregates and thus subjected to degradation due to alkali-silica reaction (ASR). A controlled concrete slab with four pockets of reactive aggregates (pure silica, wells, placitas, and spratt) was cast at Vanderbilt University and cured in representative conditions to accelerate degradation due to ASR. A set of four concrete samples were also cast and cured at the University of Alabama for ASR testing. Of these four samples, two slabs contained reactive aggregates while the other two had the non-reactive aggregate counterparts mixed throughout the samples. Vibro-acoustic testing was used on these slabs to locate ASR damage within the reactive samples. Vibro-acoustic modulation (VAM) is a vibration-based NDE method that utilizes signatures of nonlinear dynamic interactions on contact surfaces of crack or delamination damage to detect and localize the damage. VAM analysis was conducted on both the Vanderbilt and Alabama samples using multiple variables for damage detection and localization. The results from the data analysis of the vibro-acoustic testing on concrete slabs cured at Vanderbilt University and the University of Alabama are discussed in detail in this report. Results for damage localization are dependent on multiple variables used in the vibro-acoustic modulation experiments. A major focus of this report is to quantify the uncertainty in the diagnosis due to multiple factors and uncertainty sources. The uncertainty quantification methodology presented in this report was applied to VAM-based diagnosis and prognosis. However, the methodology is general, and is capable of being applied to multiple technique that collect spatially distributed data. Future work needs to investigate the incorporation of uncertainty quantification in developing a robust Prognostics and Health Management framework. Digital image correlation is a three-dimensional, full-field, optical NDE technique to measure contour, deformation, vibration, and strain. The application of the digital image correlation technique to study ASR-related degradation on a large concrete specimen at the University of Tennessee is discussed and observations are presented in this report.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Ettringite-Related Dimensional Stability of CO 2 -Cured Portland Cement Mortars

Carbonation curing, where cement is cured in a CO 2 -rich environment, is an emerging technology in the precast industry that promotes CO 2 sequestration in construction materials. It demonstrates good promise for enhancing material strength development, chemical resistance and manufacturing sustainability. A critically important but little studied aspect of carbonation curing is the dimensional stability of the cured materials, which poses a significant impact on longevity of cement-based materials and structures. In this study, we propose to use carbonation curing to substitute the conventional energy-intensive steam curing and time-consuming moisture curing, and examine the dimensional stability of Portland cement mortars manufactured by different curing approaches. The common pathology in precast concrete that potentially creates undesirable expansions, known as Delayed Ettringite Formation (DEF), is particularly investigated. Four curing approaches were examined including moist, steam (maximum temperature at 85°C to purposefully induce DEF), combined steam-carbonation, and carbonation curing in which steam curing was used to verify favorable cement chemistry for DEF and to indicate DEF onset timing. It was found that, among the four curing approaches designed in this study, the carbonation-cured mortars demonstrated the lowest expansion (~0%) whereas the steam-cured mortars showed the highest (>0.6%) after 500 days of storage in saturated limewater. Mortar expansion after the combined steam-carbonation curing (~0.1%) was lower than that of steam curing, but remained higher with respect to the moisture-cured reference. Here, the mineral ettringite was detected at 500 days after all curing approaches. However, larger ettringite crystal size (5-10 μm) with greater dispersion was observed via scanning electron microscopy after steam curing in reference to carbonation curing (< 5 μm). Additionally, the calcium carbonate precipitated by CO 2 carbonation was found to participate in the post-carbonation hydration to promote formation of monocarboaluminate and hemicarboaluminate, which stabilize ettringite and potentially lead to a secondary densification of the mortar microstructure.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Graphene Oxide Nanoribbons for High Early-Strength Cement Concrete

Longitudinal oxidative unzipping of the outer walls of multiwalled carbon nanotubes (MWCNTs) yields graphene oxide nanoribbons (GONRs), which exhibit greater open surface area and functional edge content than MWCNTs. This paper presents a study of the nano-amendment of Portland cement concrete with GONRs in concentrations between 0.05% (in weight of cement, wt%) and 0.0005 wt%, thus up to two orders of magnitude lower than that reported as lower-bound in the archival literature. The dispersibility in aqueous solution as a function of GONR concentration and oxygen weight content (O%) was assessed through dynamic light scattering (DLS) and zeta potential analysis. The results indicated that less effective suspensions were obtained for 0.05 wt% of GONRs and 22.7 O%. Therefore, GONR water suspensions with 30-40% O% were used to manufacture 50 mm × 100 mm cylindrical concrete specimens. After 7 days of curing, results from uniaxial compression tests using four specimens per configuration (MWCNT concentration and O%) showed that the incorporation of GONRs resulted in an average increase in compressive strength up to 45%. Consistent with the DLS and compression test results, SEM micrographs showed well-dispersed GONRs together with accelerated and preferential formation of calcium silicate hydrates (C-S-H) for all GONR concentrations. The results indicate, for the first time, that the incorporation of very small concentrations (as low as 0.0005 wt%) of well-dispersed GONR amendments can significantly enhance the early-age concrete strength. However, such enhancement became insignificant after 28 days of curing.

cement↗

Influence of supplementary cementitious materials on microstructure and transport properties of spacer-concrete interface

Reinforcement spacers are a critical component of concrete structures. Their presence affects microstructure and transport properties of concrete cover though this is not widely appreciated. This paper presents the first study to determine whether the negative effects of spacers can be mitigated through the use of supplementary cementitious materials such as silica fume, fly ash and blast-furnace slag. Concrete samples (>200) with different spacers, binders, curing and drying regimes were prepared and tested for diffusion, permeation, absorption, electrical conductivity, carbonation and microstructure. It was found that spacers increase all transport properties, the extent depending on type of spacer, drying regime and transport mechanism. The spacer-concrete interface is weak, porous and micro-cracked, and this lowers the resistance of concrete to ingress of aggressive agents. The beneficial effects of SCMs (strength enhancement and densification) and prolonged curing (120-day) are insufficient to overcome the negative effects of spacers. Implications for durability are discussed.

36 MATERIALS SCIENCE↗

GROUT TEMPERATURE MEASUREMENTS IN 105-R DISASSEMBLY BASIN D AND E CANAL

The 105-R Reactor Disassembly Basin Grout Placement Strategy Report (SRNL-TR-2009-00157) identifies various portions of the facility that will undergo an in-situ decommissioning process. The estimated residual radioactive contamination in the 105-R facility is shown in Figure 1. Cementitious grout formulations developed by SRNL are being used to immobilize and isolate the radioactive contamination in existing below grade portions of the 105-R building as shown by the gray-hatched area in Figure 2. A Zero Bleed flowable fill was formulated for both dry placement and for underwater placement. The first major area in the 105-R Disassembly Basin to undergo the grouting process was the D&E Canal and an underlying void space known as the Chase. Grout temperature data was needed to ensure that the grout mix design was on the correct grout curing trajectory to meet the material compressive strength requirement of 50 pounds per square inch. Initial grout temperature measurements were needed to confirm and optimize grout mix design fresh property characteristics; i.e. material strength, and set time. Grout curing temperature is an integrating fresh property characteristic that is used to estimate cementitious material strength in accordance with the Standard Practice for Estimating Concrete Strength by the Maturity Method, ASTM C 1074. The Maturity Method is used in the construction industry to estimate in-place strength of concrete to allow the start of critical construction activities; e.g. formwork removal, removal of cold weather protection, opening of roadways to traffic, etc. Applying this methodology provides an expeditious means to estimate in-place grout strength based on compressive strength laboratory results. The Maturity Method results define the relationship between strength-time and age-time that may be utilized in the field for estimating strength after a given time of placement. Maturation curves were developed under the 105-R Reactor Disassembly Basin Cementitious Materials Laboratory Test Plan (SRNL-TR-2009-00175) to establish grout mix maturation indices for this relationship. Temperature data collected from the D&E grout placement will be evaluated against these maturation indices in a subsequent analysis. Grout temperature data outside the maturation indices highlight the opportunity to adjust the grout mix design for future placements. The pre-existing grout placement will not be removed since this material will comply with strength requirements under the normal curing duration. SRNL designed a standalone measurement system to collect grout mass placement temperature data in the D&E Canal. Four vertical poles instrumented with thermocouples were positioned in the canal prior to grout placement. The thermocouples were connected to stand-alone, battery-powered data recorders mounted nearby that were configured to take temperature recordings every 10 minutes for up to 100 days. Unfortunately, after just 2 weeks, data collection was terminated because the thermocouple wires connecting the data loggers to the thermocouple poles were severed during construction activities. This report will highlight the unique challenges in designing a data collection system for the D&E canal, describe the temperature measurement system and its installation, and present calculated as well as measured temperature values.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Mitigating CO 2 emissions of concrete manufacturing through CO 2 -enabled binder reduction

Abstract Past studies on CO 2 utilization in the concrete industry have primarily focused on maximizing sequestered CO 2 , while focusing less on CO 2 avoidance possible by reducing binder use through the addition of CO 2 to concrete formulations. In this paper, we study the net CO 2 reduction and cost benefits achievable by reducing binder loading while adding CO 2 via three approaches: carbonation during curing, carbonation during mixing, or carbonation with recycled concrete aggregate. These techniques are evaluated for a cohort of concrete formulations representing the diverse mixture designs found in the US ready-mixed and precast industries. Each formulation is optimized for reduced binder loading where the use of CO 2 directly in the formulation recovers the lost compressive strength from reduced binder. We show that over an order of magnitude more CO 2 can be avoided when binder reduction is jointly implemented with CO 2 utilization compared to utilizing CO 2 alone. As a result, nearly 40% of the annual CO 2 emissions from the US concrete industry could, in principle, be eliminated without relying on novel supplemental materials, alternative binder, or carbon capture and sequestration. The recently amended 45Q tax credit will not incentivize this strategy, as it only considers carbon sequestration. However, we find that the saved material cost from reduced binder use on its own may provide a significant economic incentive to promote the joint strategy in practice. We conclude that the real value of CO 2 utilization in concrete hinges on exploiting CO 2 -induced property changes to yield additional emission reduction, not by maximizing absorbed CO 2 .

54 ENVIRONMENTAL SCIENCES↗

Vibration-Based Techniques for Concrete Structural Health Monitoring. Light Water Reactor Sustainability Program report

The objectives of this ongoing research project focus on health monitoring and data analytics of concrete slabs containing reactive aggregates and thus subjected to degradation due to alkali-silica reaction (ASR). A controlled concrete slab with four pockets of reactive aggregates (pure silica, and reactive aggregates from three different quarries) was cast at Vanderbilt University and cured in representative conditions to accelerate degradation due to ASR. A set of four concrete samples were also cast and cured at the University of Alabama for ASR testing. Of these four samples, two slabs contained reactive aggregates while the other two had the non-reactive aggregate counterparts mixed throughout the samples. Four additional slabs were cast and cured at the University of Nebraska- Lincoln. Of these four samples; one contained non-reactive aggregates and no reinforcement, one contained reactive aggregates and no reinforcement, one contained reactive aggregates and rebar reinforcement in one direction, and the last contained reactive aggregates and reinforcement in two directions. Single frequency and dual frequency tests were used on these slabs to locate ASR damage within the specimens containing reactive aggregates. The vibration tests were conducted with different sensor and actuator configurations to facilitate damage detection and localization. The results from the data analysis of the dynamic testing on concrete slabs are discussed in detail in this report. Results for damage localization are dependent on multiple parameters used in the tests. This report investigates different methods of data fusion including voting, raw averaging, damage index averaging, and Bayesian fusion.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Concrete mixture characterization. Cementitious barriers partnership

This report summarizes the characterization study performed on two concrete mixtures used for radioactive waste storage. Both mixtures were prepared with approximately 425 kg of binder. The testing protocol mostly focused on determining the transport properties of the mixtures; volume of permeable voids (porosity), diffusion coefficients, and water permeability were evaluated. Tests were performed after different curing durations. In order to obtain data on the statistical distribution of transport properties, the measurements after 2 years of curing were performed on 10+ samples. Overall, both mixtures exhibited very low tortuosities and permeabilities, a direct consequence of their low water-to-binder ratio and the use of supplementary cementitious materials. The data generated on 2-year old samples showed that porosity, tortuosity and permeability follow a normal distribution. Chloride ponding tests were also performed on test samples. They showed limited chloride ingress, in line with measured transport properties. These test results also showed that both materials react differently with chloride, a consequence of the differences in the binder chemical compositions.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗